SIST EN 300 019-2-7 V3.0.1:2006
(Main)Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-7: Specification of environmental tests; Portable and non-stationary use
- Abstract
The present document specifies test methods and severities for the verification of the required resistibility of telecommunication equipment according to the relevant environmental class. The tests defined in the present document apply to portable and non-stationary use of equipment, covering the environments stated in EN 300 019-1-7 [1].
- Status
- Published
- Publication Date
- 31-Jan-2006
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Feb-2006
- Due Date
- 01-Feb-2006
- Completion Date
- 01-Feb-2006
SIST EN 300 019-2-7 V3.0.1:2006 is the Slovenian adoption of ETSI EN 300 019-2-7 V3.0.1. It specifies environmental test methods and severities for telecommunications equipment used in portable and non-stationary applications, so a reader can check whether equipment is built to withstand the conditions expected in its declared environmental class.
What does SIST EN 300 019-2-7 V3.0.1:2006 specify?
SIST EN 300 019-2-7 V3.0.1:2006 specifies the environmental tests used to verify the required resistibility of telecommunication equipment for portable and non-stationary use. The scope is tied to the environmental classes defined in EN 300 019-1-7 [1], and the document is organized around four test specifications plus notes to the tables.
The main structure is:
- Clause 1 - Scope
- Clause 2 - References
- Clause 3 - Environmental test specifications
- 3.1 T 7.1: Temperature-controlled locations
- 3.2 T 7.2: Partly temperature-controlled locations
- 3.3 T 7.3: Partly weatherprotected and non-weatherprotected locations
- 3.4 T 7.3E: Partly weatherprotected and non-weatherprotected locations - extended
- Clause 4 - Notes to tables
- Annex A - Informative bibliography
What are the key requirements of SIST EN 300 019-2-7 V3.0.1:2006?
SIST EN 300 019-2-7 V3.0.1:2006 requires the equipment under test to be treated as operational throughout the stated test conditions unless the product specification says otherwise. In practice, that means the test plan has to define the required performance before, during and after testing, and it has to choose input and load conditions that fully exercise the equipment. Heat dissipation is normally maximized, except in the steady-state low-temperature test, where it is minimized.
The document separates portable use into four environmental classes
- T 7.1 covers temperature-controlled enclosed locations where humidity is usually not controlled.
- T 7.2 covers enclosed locations with no temperature or humidity control, but with possible heating.
- T 7.3 covers partly weatherprotected and non-weatherprotected locations, with non-weatherprotected use limited in cold seasons.
- T 7.3E extends that coverage to locations of any construction except Extremely Cold and Cold Climates where extremely low temperatures are avoided.
This matters because the declared location determines which climatic and mechanical tests apply.
Climatic tests are selected by location type
The climatic tables in clauses 3.1 to 3.4 cover cold, dry heat, temperature change, high relative humidity, condensation, solar radiation, water exposure and other environmental factors. T 7.1 mainly addresses indoor-like conditions, while T 7.2 adds more severe humidity, icing and biological exposure. T 7.3 and T 7.3E add outdoor exposure, including rain and impacting water, and T 7.3E uses the broadest low-temperature severity.
Some conditions are handled by design guidance rather than by a test
The notes state that no test is recommended for some parameters, such as low and high air pressure, chemically active substances, and mechanically active substances. For these cases, the document expects the designer to consider the severities when choosing materials and components. That matters in practice because the environmental category still affects design decisions even when it is not represented by a separate test.
Mechanical tests apply across all portable classes
Tables 5 and 6 define the mechanical tests for all classes from 7.1 to 7.3E. They include vibration, shock, bump, free fall, and drop and topple tests, with different severities for IEC 721 class 7M2 and 7M3. The notes also explain why random vibration is preferred over sinusoidal vibration, and why free fall and drop/topple are both used for portable equipment.
The notes explain how to run the tests
The notes clarify details such as cold start-up timing, the effect of solar heating at high temperature, the use of temperature-change testing to check design tolerancing, and the choice of rain and bump methods. In practice, these notes help a test lab set up a repeatable programme and help a buyer or manufacturer understand what the chosen severity is intended to represent.
What terms does SIST EN 300 019-2-7 V3.0.1:2006 define?
- Portable and non-stationary use - equipment installed permanently or temporarily and moved between locations, so it must tolerate changing environmental exposure.
- Environmental class - the standardized set of conditions from EN 300 019-1-7 that defines the expected environment.
- T 7.1 - the test specification for temperature-controlled locations.
- T 7.2 - the test specification for partly temperature-controlled locations.
- T 7.3E - the extended test specification for partly weatherprotected and non-weatherprotected locations.
- Acceleration Spectral Density (ASD) - the way random vibration severity is expressed in the mechanical test tables.
- IEC 721 class 7M2 / 7M3 - the mechanical severity classes used for vibration, shock, bump and fall testing.
Who uses SIST EN 300 019-2-7 V3.0.1:2006?
Telecommunications equipment designers use SIST EN 300 019-2-7 V3.0.1:2006 to choose materials, housings, mounts and internal construction for portable equipment. Test laboratories use it to set up climate, vibration, shock, bump and fall programmes. Quality managers and product specifiers use it to define the environmental class and the pass/fail criteria in product specifications. Buyers and procurement teams use it when they need portable or movable telecom equipment that matches a stated operating environment.
What changed in SIST EN 300 019-2-7 V3.0.1:2006 from the previous edition?
The history lists earlier publications of ETS 300 019-2-7, including V2.1.2 and V3.0.0, before V3.0.1. This edition is the later publication in that sequence.
Which standards are used with SIST EN 300 019-2-7 V3.0.1:2006?
- EN 300 019-1-7 [1] - defines the environmental classes and conditions for portable and non-stationary use.
- IEC 60068-2 (all parts) [2] - provides the test methods used throughout the climatic and mechanical tables.
- EN 300 019-2-0 [3] - gives the general overview of part 2.
- ISO 4180-2 [4] - supports the selection of free-fall test heights by mass.
- ETR 035 [5] - provides guidance and terminology for environmental engineering.
What does the SIST EN 300 019-2-7 V3.0.1:2006 document contain?
SIST EN 300 019-2-7 V3.0.1:2006 contains four climatic test tables, two mechanical test tables, and a detailed note section that explains the intent behind the selected severities. It also identifies the IEC test methods used for cold, dry heat, damp heat, temperature change, vibration, shock, bump, free fall and drop/topple. Annex A gives an informative bibliography, and the foreword places the document within the wider EN 300 019 series of environmental conditions and environmental tests for telecommunications equipment.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.
IMP NDT d.o.o.
Non-destructive testing services. Radiography, ultrasonic, magnetic particle, penetrant, visual inspection.
Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Sponsored listings
Frequently Asked Questions
SIST EN 300 019-2-7 V3.0.1:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-7: Specification of environmental tests; Portable and non-stationary use". This standard covers: The present document specifies test methods and severities for the verification of the required resistibility of telecommunication equipment according to the relevant environmental class. The tests defined in the present document apply to portable and non-stationary use of equipment, covering the environments stated in EN 300 019-1-7 [1].
The present document specifies test methods and severities for the verification of the required resistibility of telecommunication equipment according to the relevant environmental class. The tests defined in the present document apply to portable and non-stationary use of equipment, covering the environments stated in EN 300 019-1-7 [1].
SIST EN 300 019-2-7 V3.0.1:2006 is classified under the following ICS (International Classification for Standards) categories: 19.040 - Environmental testing; 33.050.01 - Telecommunication terminal equipment in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 019-2-7 V3.0.1:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-2006
Okoljski inženiring (EE) – Okoljski pogoji in preskusi vplivov okolja na
telekomunikacijsko opremo – 2-7. del: Specifikacija preskusov vplivov okolja –
Prenosna in nefiksna uporaba
Environmental Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 2-7: Specification of environmental tests; Portable
and non-stationary use
Ta slovenski standard je istoveten z: EN 300 019-2-7 Version 3.0.1
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
European Standard (Telecommunications series)
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2-7: Specification of environmental tests;
Portable and non-stationary use
2 ETSI EN 300 019-2-7 V3.0.1 (2003-04)
Reference
REN/EE-01034-2-7[2]
Keywords
environment, mobile, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, send your comment to:
editor@etsi.org
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2003.
All rights reserved.
TM TM TM
DECT , PLUGTESTS and UMTS are Trade Marks of ETSI registered for the benefit of its Members.
TM
TIPHON and the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
ETSI
3 ETSI EN 300 019-2-7 V3.0.1 (2003-04)
Contents
Intellectual Property Rights.4
Foreword.4
1 Scope.5
2 References.5
3 Environmental test specifications.5
3.1 Specification T 7.1: Temperature-controlled locations .6
3.2 Specification T 7.2: Partly temperature-controlled locations .7
3.3 Specification T 7.3: Partly weatherprotected and non-weatherprotected locations.9
3.4 Specification T 7.3E: Partly weatherprotected and non-weatherprotected locations - extended.10
4 Notes to tables .14
4.1 General note.14
4.2 Notes to tables 1 to 6 .14
Annex A (informative): Bibliography.16
History .17
ETSI
4 ETSI EN 300 019-2-7 V3.0.1 (2003-04)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
All published ETSI deliverables shall include information which directs the reader to the above source of information.
Foreword
This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental
Engineering (EE).
The present document is part 2, sub-part 7 of a multi-part deliverable covering environmental conditions and
environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions";
Part 2: "Specification of environmental tests";
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".
Part 1 specifies different standardized environmental classes covering climatic and biological conditions, chemically
and mechanically active substances and mechanical conditions during storage, transportation and in use.
Part 2 specifies the recommended test severities and test methods for the different environmental classes.
Part 2-0 forms a general overview of part 2. The present document deals with portable and non-stationary use.
National transposition dates
Date of latest announcement of this EN (doa): 31 July 2003
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 January 2004
Date of withdrawal of any conflicting National Standard (dow): 31 January 2004
ETSI
5 ETSI EN 300 019-2-7 V3.0.1 (2003-04)
1 Scope
The present document specifies test methods and severities for the verification of the required resistibility of
telecommunication equipment according to the relevant environmental class.
The tests defined in the present document apply to portable and non-stationary use of equipment, covering the
environments stated in EN 300 019-1-7 [1].
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present
document.
• References are either specific (identified by date of publication and/or edition number or version number) or
non-specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
[1] ETSI EN 300 019-1-7: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-7: Classification of environmental
conditions; Portable and non-stationary use".
[2] IEC 60068-2 (all parts): "Environmental testing - Part 2: Tests".
[3] ETSI EN 300 019-2-0: "Equipment Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2-0: Specification of environmental
tests; Introduction".
[4] ISO 4180-2 (1980): "Complete, filled transport packages - General rules for the compilation of
performance test schedules - Part 2: Quantitive data".
[5] ETSI ETR 035: "Equipment Engineering (EE); Environmental engineering Guidance and
terminology".
3 Environmental test specifications
The detailed descriptions of the environmental conditions are given in clauses 4 and 5 of EN 300 019-1-7 [1].
EN 300 019-2-0 [3] forms a general overview of part 2 of the present document.
The equipment under test is assumed to be in its operational state throughout the test conditions described in this part
unless otherwise stated. The required performance before, during and after the test needs to be specified in the product
specification. Input and load conditions of the equipment shall be chosen to obtain full utilization of the equipment
under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where it shall be
minimized.
ETSI
6 ETSI EN 300 019-2-7 V3.0.1 (2003-04)
3.1 Specification T 7.1: Temperature-controlled locations
This specification applies to use at, and direct transfer between, permanently temperature-controlled enclosed locations where humidity is usually not controlled. See tables 1, 5
and 6.
Table 1: Test specification T 7.1: Temperature-controlled locations - climatic tests
Environmental parameter Environmental Environmental test specification T7.1: Portable,
Class 7.1 Temperature - controlled location
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
low (°C) +5 +5 16 h Ab/Ad: Cold 1
IEC 60068-2-1 [2]
Air temperature high (°C) +40 +40 or +50 16 h Bb/Bd: Dry heat 2
IEC 60068-2-2 [2]
change (°C) +5/+25 +5/+25 3 cycles Na: Change of 3
IEC 60068-2-14 [2]
t = 3 h temperature
low (%) 5 none 4
relative high (%) 85 93 96 h Cb: Damp heat 5
IEC 60068-2-56 [2]
(°C) +30 +30 steady state
Humidity condensation (%) yes 90-100 2 cycles Db: Damp heat 6
IEC 60068-2-30 [2]
(°C) +30 Cyclic, variant 2
absolute 1 none 4
low (g/m )
25 none 7
high (g/m )
pressure low (kPa) 70 none 8
Air high (kPa) 106 none 8
speed (m/s) 5,0 none 4
intensity (mm/min) no
rain
Water low temperature (°C) no
other sources no
icing & frosting no
Radiation solar 700 none 11
(W/m )
heat 600 none 11
(W/m )
sulphur 0,3/1,0 none 12
SO (mg/m )
0,1/0,5 none 12
HS (mg/m )
Chemically salts Sea and road salt mist none 12
active
chlorine 0,1/0,3 none 12
Cl (mg/m )
substances
0,1/0,5 none 12
HCl (mg/m )
nitrogen 0,5/1,0 none 12
NO (mg/m )
x
1,0/3,0 none 12
NH (mg/m )
hydrogen fluoride 0,01/0,03 none 12
HF (mg/m )
ozone 0,05/0,1 none 12
O (mg/m )
ETSI
7 ETSI EN 300 019-2-7 V3.0.1 (2003-04)
Environmental parameter Environmental Environmental test specification T7.1: Portable,
Class 7.1 Temperature - controlled location
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
Mechanically
dust 1,5 none 13
sedimentation (mg/(m h))
active
0,2 none 13
suspension (mg/m )
substances
sand 30 none 13
(mg/m )
Flora and micro organisms no
Fauna
rodents, insects no
no: This condition does not occur in this class.
none: Verification is required only in special cases.
NOTES: Number of note, see clause 3.4.
3.2 Specification T 7.2: Partly temperature-controlled locations
This specification applies to use at and direct transfer between, enclosed locations having neither temperature nor humidity control but where heating may be used to avoid low
temperatures. Building construction avoids extremely high temperatures. See tables 2, 5 and 6.
Table 2: Test specification T 7.2: Partly temperature-controlled locations - climatic tests
Environmental parameter Environmental Environmental test specification T7.2: Portable,
Class 7.2 Partly temperature- controlled locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
low (°C) -5 -5 16 h Ab/Ad: Cold 1
IEC 60068-2-1 [2]
Air temperature high (°C) +45 +45 or +55 16 h Bb/Bd: Dry heat 2
IEC 60068-2-2 [2]
change (°C) -5/+25 -5/+25 3 cycles Na: Change of 3
IEC 60068-2-14 [2]
t = 3 h temperature
low (%) 5 none 4
relative high (%) 95 93 96 h Cb: Damp heat 5
IEC 60068-2-56 [2]
(°C) +30 steady state
Humidity condensation (%) yes 90-100 2 cycles Db: Damp heat 6
IEC 60068-2-30 [2]
(°C) +30 Cyclic, variant 2
absolute 1 none 4
low (g/m )
29 none 7
high (g/m )
pressure low (kPa) 70 none 8
Air high (kPa) 106 none 8
speed (m/s) 5,0 none 4
intensity (mm/min) no
rain
Water low temperature (°C) no
other sources dripping water none 10
icing & frosting yes none 4
ETSI
8 ETSI EN 300 019-2-7 V3.0.1 (2003-04)
Environmental parameter Environmental Environmental test specification T7.2: Portable,
Class 7.2 Partly temperature- controlled locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
Radiation solar 700 none 11
(W/m )
heat 600 none 11
(W/m )
sulphur 0,3/1,0 none 12
SO (mg/m )
0,1/0,5 none 12
HS (mg/m )
Chemically salts sea and road salt mist none 12
active
chlorine 0,1/0,3 none 12
Cl (mg/m )
substances
0,1/0,5 none 12
HCl (mg/m )
nitrogen 0,5/1,0 none 12
NO (mg/m )
x
1,0/3,0 none 12
NH (mg/m )
hydrogen fluoride 0,01/0,03 none 12
HF (mg/m )
ozone 0,05/0,1 none 12
O (mg/m )
Mechanically dust 20 none 13
sedimentation (mg/(m h))
active 3
5,0 none 13
suspension (mg/m )
substances
sand 300 none 13
(mg/m )
Flora and micro organisms moulds, fungus, etc. none 14
Fauna
rodents, insects rodents, etc. none 14
no: This condition does not occur in this class.
none: Verification is required only in special cases.
NOTES: Number of note, see clause 3.4.
ETSI
9 ETSI EN 300 019-2-7 V3.0.1 (2003-04)
3.3 Specification T 7.3: Partly weatherprotected and non-weatherprotected locations
This specification applies to use at totally or partly weatherprotected locations of such construction that ext
...