oSIST prEN 1129:2026
(Main)Furniture - Foldaway beds - Safety requirements and test methods
- Abstract
This document specifies safety requirements and test methods for foldaway beds for domestic and non-domestic use.
The requirements are only applicable to the foldaway function of the bed.
The safety, strength and durability of the bed itself, including high beds and bunk beds, as well as other functions e.g. seating, tables or storage, are covered by other European Standards.
Safety that is dependent upon the structure of the building is not included.
It does not include requirements for electrical safety.
It does not include requirements for the resistance to ageing, degradation and flammability.
The requirements are applicable without regard to materials, design, construction or manufacturing process.
This document does not apply to folding beds, camping beds and convertible bed/chairs or settees which are covered by other European safety standards.
- Status
- Not Published
- Public Enquiry End Date
- 19-Dec-2026
- Technical Committee
- POH - Furniture
oSIST prEN 1129:2026 is a SIST draft standard for furniture foldaway beds. It specifies safety requirements and test methods for foldaway beds for domestic and non-domestic use, with the requirements limited to the foldaway function. It is written for manufacturers, test laboratories, installers, quality managers, and buyers who need to check safety, stability, mounting, operating forces, and product information.
What does oSIST prEN 1129:2026 specify?
oSIST prEN 1129:2026 covers safety requirements and test methods for foldaway beds, and only for the foldaway function. It applies regardless of materials, design, construction, or manufacturing process, but it leaves the rest of the bed and other product functions to other European standards.
The scope excludes safety that depends on the building structure, electrical safety, resistance to ageing, degradation, and flammability. It also excludes folding beds, camping beds, and convertible bed/chairs or settees that are covered elsewhere.
The document is organized into Clauses 1 to 11, followed by two informative annexes.
| Annex | What it covers |
|---|---|
| Annex A | Rationale for the requirements and tests |
| Annex B | Explanation of how to determine the number of fixings required per anchor device |
What are the key requirements of oSIST prEN 1129:2026?
oSIST prEN 1129:2026 is built around a set of practical checks for safe movement, stability, mounting, durability, and product information. In practice, it tells a test lab how to prepare the bed, what loads to apply, what counts as unacceptable movement, and what must be stated in instructions, marking, and point-of-sale information.
Test conditions and equipment
Clauses 4 and 5 require the bed to be tested as delivered, assembled and configured according to the supplied instructions, and set up in the most adverse configuration unless stated otherwise. The standard fixes how forces are applied, how long they are held, the tolerances for force, speed, dimensions, and angles, and it defines the loading pad and test floor.
That matters because results must be comparable between products and test houses. If the bed cannot be tested exactly as described, the lab has to use the closest practical method and record the deviation in the test report.
General safety and pinch-point control
Clause 6.1 requires manufacturer-made assembly and pilot holes, tool-only dismantling, and safe edges and corners on parts accessible during opening and closing. It also requires attention to the minimum and maximum mattress weight recommended by the manufacturer during testing.
Clause 6.2 addresses shearing and compression points. If handles or handgrips are used, their clearances must stay within the stated safe distances; if there are no handles, the moving and fixed parts must not create pinch points in the defined user zone. This is a direct design control on the places where fingers can be trapped during operation.
Stability and mounting to the building
Clause 6.3 covers the stability of free-standing foldaway beds in forward and rearward directions. The bed must not overturn in the forward stability test, and for the rearward test it must not tip beyond the stated angle, while the start-of-tilt force must exceed the stated minimum. The method uses the recommended heaviest and lightest mattresses, and the test is repeated for beds with multiple sleeping surfaces.
Clause 6.4 applies to beds fixed to a building structure. The bed needs at least two anchor devices, at least two holes in each, spacing between mounting holes greater than 50 mm, and fixings that cannot be released without a tool. The document also sets a minimum restraining force per anchor device and requires that value to be permanently attached to the rear of the bed and included in the installation instructions.
This matters because wall attachment is part of the safety case. The standard links the product marking, the instructions, and the mounting design so the installer knows what the wall and fixings must carry.
Opening, closing, unintended movement, and durability
Clauses 6.5 and 6.6 define how hard the bed may be to open and close. The opening force is limited, with two alternative opening behaviors allowed depending on whether the bed has an equilibrium zone, and the closing force must stay below the stated limit throughout the movement. The same clauses also set requirements for automatic movement after release of a lock and for how far the bed may move unintentionally.
Clause 6.7 checks durability. Non-electrically operated foldaway mechanisms are cycled 10,000 times, and electrically operated mechanisms are also cycled 10,000 times with a defined duty cycle. After these tests, the bed must still open and close as intended and still meet the opening and closing force requirements where applicable.
Clause 6.8 checks unintended closing, and Clause 6.9 checks unintended opening, including special cases for beds with a seat function or an additional table function. Clause 6.10 sets requirements for locking mechanisms, including residual force, two-action designs, or the need to raise the bed base, and it adds a 1,000-cycle durability test. For a buyer or engineer, these clauses are the core safety checks against accidental movement during use.
Test sequence, instructions, marking, and reporting
Clause 7 fixes the order of tests, which matters because some checks are repeated before and after durability testing. Clauses 8 to 11 then control what the user receives: installation instructions, permanent product marking, point-of-sale information, and the minimum contents of the test report.
That means the standard is not only about the product body. It also controls how the bed is identified, installed, and described to the user, which is important when the product is assembled on site or sold through retail channels.
What terms does oSIST prEN 1129:2026 define?
- Foldaway bed - a bed with an opening/closing mechanism that rotates about at least one horizontal axis so it can be stored against a wall or in a cabinet.
- Open position - the sleeping position of the bed.
- Closed position - the stored position of the bed.
- Parts accessible during opening and closing - parts that can be reached only while the bed is being opened or closed, with the recommended minimum mattress in place.
- Resisting force - the force needed to start the foldaway movement, whether opening or closing.
- Equilibrium zone - the angle range where the bed is in a balanced state between open and closed.
- Anchor device - the component used to fix the bed structure to a building structure.
- Locking mechanism - the assembly of locking device(s) and operating device(s) that keeps the product in position.
Who uses oSIST prEN 1129:2026?
oSIST prEN 1129:2026 is used by furniture manufacturers, product designers, and compliance teams developing foldaway beds for domestic and non-domestic use. Test laboratories and certification bodies use it to run safety, stability, durability, and movement tests.
Installers and building contractors use it when the bed is fixed to a wall or other building structure. Buyers, retailers, and quality managers use it to check whether the product information, marking, and installation instructions are complete and suitable for procurement or sale.
What changed in oSIST prEN 1129:2026 from the previous edition?
oSIST prEN 1129:2026 will supersede EN 1129-1:1995 and EN 1129-2:1995. The draft standard states these main changes compared with those earlier editions:
- requirements and test methods are combined in one document;
- test methods are updated or modified so they support the requirements properly;
- requirements for free-standing foldaway beds are added;
- a durability test for electrically operated foldaway bed mechanisms is added;
- requirements for beds with extra functions such as seating and tables are added;
- the structure is revised and aligned with other furniture standards;
- the unintended closing and opening requirements are changed to reflect actual risks;
- locking mechanism requirements and durability are added;
- instructions for use are updated;
- point-of-sale information is added;
- the former test scheme from Annex A is brought into the main text;
- a new informative Annex A gives the rationale;
- a new informative Annex B explains how to determine the number of fixings required per anchor device.
Which standards are used with oSIST prEN 1129:2026?
- EN 1728:2012 - provides seating test methods for strength and durability, and Clause 6.9.2 uses its seat loading point definition when a foldaway bed includes a seat function.
What does the oSIST prEN 1129:2026 document contain?
The document contains the scope, normative references, terms and definitions, general test conditions, test equipment requirements, and the detailed safety requirements for foldaway beds. It also includes the fixed test sequence, installation instruction content, marking, purchase information, and the minimum test report content.
Clause 6 is the main technical body and includes stability tests, mounting requirements, opening and closing behavior, durability cycling, unintended movement tests, and locking mechanism checks. The document also includes figures for the loading pad and for the key test set-ups, plus a formula-based method for mounting force assessment.
Annex A gives the reasoning behind the requirements, which helps users understand why each test exists and what risk it addresses. Annex B gives examples and calculation guidance for anchor-device fixings, including how wall type and fixing choice affect installation practice.
Relations
- Effective Date
- 28-Jan-2026
- Effective Date
- 01-Dec-2026
- Effective Date
- 01-Dec-2026
Frequently Asked Questions
oSIST prEN 1129:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Furniture - Foldaway beds - Safety requirements and test methods". This standard covers: This document specifies safety requirements and test methods for foldaway beds for domestic and non-domestic use. The requirements are only applicable to the foldaway function of the bed. The safety, strength and durability of the bed itself, including high beds and bunk beds, as well as other functions e.g. seating, tables or storage, are covered by other European Standards. Safety that is dependent upon the structure of the building is not included. It does not include requirements for electrical safety. It does not include requirements for the resistance to ageing, degradation and flammability. The requirements are applicable without regard to materials, design, construction or manufacturing process. This document does not apply to folding beds, camping beds and convertible bed/chairs or settees which are covered by other European safety standards.
This document specifies safety requirements and test methods for foldaway beds for domestic and non-domestic use. The requirements are only applicable to the foldaway function of the bed. The safety, strength and durability of the bed itself, including high beds and bunk beds, as well as other functions e.g. seating, tables or storage, are covered by other European Standards. Safety that is dependent upon the structure of the building is not included. It does not include requirements for electrical safety. It does not include requirements for the resistance to ageing, degradation and flammability. The requirements are applicable without regard to materials, design, construction or manufacturing process. This document does not apply to folding beds, camping beds and convertible bed/chairs or settees which are covered by other European safety standards.
oSIST prEN 1129:2026 is classified under the following ICS (International Classification for Standards) categories: 97.140 - Furniture. The ICS classification helps identify the subject area and facilitates finding related standards.
oSIST prEN 1129:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 22435:2024, SIST EN 1129-1:1996, SIST EN 1129-2:1996. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
oSIST prEN 1129:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 foldaway bed
- 3.2 open position
- 3.3 closed position
- 3.4 parts accessible during opening and closing
- 3.5 sleeping surface
- 3.6 end pivoted bed
- 3.7 side pivoted bed
- 3.8 levelling device
- 3.9 locking mechanism
- 3.10 locking device
- 3.11 operating device
- 3.12 equilibrium
- 3.13 equilibrium zone
- 3.14 pilot hole
- 3.15 anchor device
- 3.16 duty cycle
- 4 General test conditions
- 4.1 Preliminary preparation
- 4.2 Application of forces
- 4.3 Tolerances
- 5 Test equipment
- 5.1 General
- 5.2 Loading pad
- 5.3 Test floor
- 5.4 Stops
- 6 Safety requirements
- 6.1 General safety requirements
- 6.2 Shearing and compression points
- 6.3 Stability of free-standing foldaway beds
- 6.4 Mounting of the bed to the building structure
- 6.5 Intended opening
- 6.6 Intended closing
- 6.7 Durability of foldaway mechanism
- 6.8 Unintended closing
- 6.9 Unintended opening
- 6.10 Locking mechanism
- 7 Test sequence
- 8 Installation and product information
- 9 Marking
- 10 Test report
- Annex A
- Annex B
- Annex C
1 Scope
This document specifies safety requirements and test methods for foldaway beds for domestic and nondomestic use. The requirements are only applicable to the foldaway function of the bed. The safety, strength and durability of the bed itself, including high beds and bunk beds, as well as other functions e.g. seating, tables or storage, are covered by other European Standards. Safety that is dependent upon the structure of the building is not included. It does not include requirements for electrical safety.
It does not include requirements for the resistance to ageing, degradation and flammability. The requirements are applicable without regard to materials, design, construction or manufacturing process.
This document does not apply to folding beds, camping beds and convertible bed/chairs or settees which are covered by other European safety standards.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1728:2012, Furniture - Seating - Test methods for the determination of strength and durability
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https://www.iso.org/obp
- IEC Electropedia: available at https://www.electropedia.org/
3.1 foldaway bed
bed equipped with an opening/closing mechanism, which is rotated about at least one horizontal axis, allowing the bed to be stored against a wall, or in a cabinet when not in use Note 1 to entry: The entire bed is either freestanding or fixed to the building structure.
3.2 open position
configuration of the bed where the sleeping surface is positioned for sleeping
3.3 closed position
configuration of the bed where the sleeping surface is positioned for storing
3.4 parts accessible during opening and closing
parts to which access can only be gained when opening and closing the bed, when a mattress equivalent to the minimum size of mattress recommended by the manufacturer is on the sleeping surface
oSIST prEN 1129:2026 prEN 1129:2026 (E)
3.5 sleeping surface
part on which a mattress is placed
3.6 end pivoted bed
foldaway bed pivoting around one short side of the sleeping surface
3.7 side pivoted bed
foldaway bed pivoting around one long side of the sleeping surface
3.8 levelling device
adjustable device intended to keep the item of furniture perpendicular to the floor
3.9 locking mechanism
assembly consisting of one or more locking device(s) and one or more operating device(s) Note 1 to entry: A locking mechanism could be engaged automatically or manually. Note 2 to entry: Example for a locking mechanism: automatic latch lock.
3.10 locking device
component that maintains part(s) of the product in one of the end positions (open or closed position) EXAMPLE Latch, a hook, an over centre lock.
3.11 operating device
part of the locking mechanism(s) designed to be activated by the user by one or several action(s)
3.12 equilibrium
state in which opposing forces or influences are balanced
3.13 equilibrium zone
zone where the foldaway bed is between open position (configuration where the sleeping surface is positioned for sleeping) and closed position (configuration where the sleeping surface is positioned for storing), measured in degrees from the closed position, in which the state of equilibrium exists
3.14 pilot hole
small hole drilled as a guide for the insertion of a nail or screw, or for the drilling of a larger hole
3.15 anchor device
component to fix the foldaway bed structure to a building structure
oSIST prEN 1129:2026 prEN 1129:2026 (E)
3.16 duty cycle
length of time an electrically powered operating mechanism may be operated without impairing its useful life
4 General test conditions
4.1 Preliminary preparation
The bed shall be tested as delivered. The bed shall be assembled and/or configured according to the instructions supplied. Unless otherwise stated, the most adverse configuration shall be used for each test. If mounting or assembly instructions are not supplied, the mounting or assembly method shall be recorded in the test report. Fittings shall be tightened before testing and shall not be retightened unless specifically required in the manufacturer’s instructions. If the configuration needs to be changed in order to produce worst-case conditions, this shall be recorded in the test report. Levelling devices shall be set as near as possible to 5 mm from their fully open position, whilst ensuring the unit is horizontal to the floor.
For freestanding beds fitted with castors, the castors shall be set to the most adverse position and, for lockable castors, the castors shall be locked.
Freestanding foldaway beds shall be secured against unintentional rolling away or sliding during testing by blocking with stops (5.4).
In case the product was moved before any testing, open and close the bed 10 times before testing. Unless otherwise specified by the manufacturer, the sample for test shall be stored in indoor ambient conditions for at least 24 h immediately prior to testing.
The tests shall be carried out at indoor ambient conditions but if during a test the temperature is outside the range 15 °C to 27 °C the maximum and/or minimum temperature shall be recorded in the test report. If a test cannot be carried out as specified, e.g. because a loading pad cannot be used for the application of a force due to the design of a product, the test shall be carried out as closely as possible to that specified. Any modification to the test method shall be technically justified and recorded in the test report. Before beginning the testing, visually inspect the bed thoroughly. Record any defects so that they are not assumed to have been caused by the tests. Carry out measurements, if specified.
4.2 Application of forces
The test forces in the static load tests shall be applied sufficiently slowly to ensure that negligible dynamic load is applied. Unless otherwise specified, each specified force shall be maintained for not less than 10 s and not more than 15 s.
The forces may be replaced by masses. The relationship 10 N = 1 kg shall be used. The weight of the loading pad and any associated test equipment shall be considered when applying the test load.
4.3 Tolerances
Unless otherwise stated the following tolerances are applicable:
- forces: ± 5 % of the nominal force;
- velocities: ± 5 % of the nominal velocity;
- masses: ± 1 % of the nominal mass;
oSIST prEN 1129:2026 prEN 1129:2026 (E) - dimensions:
- all dimensions less than 200 mm shall have a tolerance of ± 1 mm of the nominal dimension;
- all other dimensions shall have a tolerance of ± 0,5 % of the nominal dimension;
- angles: ± 2° of the nominal angle.
The accuracy for the positioning of loading pads shall be ± 5 mm. NOTE For the purposes of uncertainty measurement, test results are not considered to be adversely affected when the above tolerances are met.
5 Test equipment
5.1 General
Unless otherwise stated, the tests may be applied by any suitable device, because results are dependent only upon correctly applied forces and not on the apparatus.
The test equipment shall not inhibit deformation of the bed, i.e. it shall move so that it can follow the deformation of the bed during testing, so that the loads are always applied at the specified points and in the specified directions.
5.2 Loading pad
Rigid disc 200 mm in diameter, the face of which has a convex spherical curvature of (300 ± 5) mm radius, with a 12 mm edge radius (see Figure 1).
Dimensions in millimetres
Figure 1 — Loading pad
5.3 Test floor
A rigid, horizontal and flat surface.
oSIST prEN 1129:2026 prEN 1129:2026 (E)
5.4 Stops
Devices to prevent the article from sliding but not tilting, not higher than 12 mm, except in cases where the design of the unit necessitates the use of higher stops, in which case the lowest stop that will prevent the item from moving shall be used (EN 16122:2012, 5.3).
6 Safety requirements
6.1 General safety requirements
All assembly and pilot holes shall be made by the manufacturer. It shall not be possible to dismantle the bed or its components without the use of a tool. During operation of the foldaway function (i.e. moving the bed from the closed position to the open position and back):
a) Edges and corners of parts accessible during opening and closing shall be rounded or chamfered and free from burrs and sharp edges.
b) There shall be no open-ended tubes in parts accessible during opening and closing. The maximum and minimum weight of the mattress recommended by the manufacturer shall be taken into account during the test.
6.2 Shearing and compression points
If handles/handgrips are used to open/close the bed, they shall have safety distances in any position of movement of ≤ 8 mm or ≥ 18 mm, between the handles/handgrips and other components. If there are no handles/handgrips there shall be no shearing and compression points that can reach < 18 mm between rigid moving and/or rigid stationary parts when operating the bed. This applies to a zone measured from 1 000 mm up to and including 1 600 mm, measured vertically from the floor surface, and within that zone 60 mm from the edge’s users may use for closing the bed.
6.3 Stability of free-standing foldaway beds
6.3.1 Stability – Forward
6.3.1.1 Requirements
This requirement does not apply to beds, and their associated components (e.g. wardrobes into which the bed is mounted) that are intended to be fixed to the structure of the building. When tested in accordance with 6.3.1.2 the product shall not overturn.
6.3.1.2 Test method
6.3.1.2.1 General Place the product on the test floor (5.3). Place the heaviest mattress(es) recommended by the manufacturer on the sleeping surface(s) or apply an evenly distributed load to the sleeping surface(s) such that the total load and centre of gravity is equivalent to the maximum mattress weight and dimensions recommended by the manufacturer.
Castors shall be in the position most likely to cause overturning.
oSIST prEN 1129:2026 prEN 1129:2026 (E) 6.3.1.2.2 Foldaway beds with one sleeping surface Block the foldaway mechanism at a 70° angle in relation to vertical with a strap fixed from the foldaway bed structure to the foldaway bed sleeping surface, or by other suitable means, without preventing lifting and/or tipping of the bed (see Figure 2).
Apply a vertical downward force of 750 N to the mid point of the front edge of the foldaway bed sleeping surface (see Figure 2). The overturning force shall be maintained for (5 ± 2) seconds. Record if the product overturns.
Key 1 foldaway bed structure 2 foldaway bed sleeping surface 3 strap F force Figure 2 — Stability of a free-standing foldaway bed - principle 6.3.1.2.3 Foldaway beds with multiple sleeping surfaces in a structure that can be opened and closed separately Block the foldaway mechanism of the lower bed at a 70° angle in relation to vertical with a strap fixed from the foldaway bed structure to the foldaway bed sleeping surface, or by other suitable means, without preventing lifting and/or tipping of the bed. Apply a vertical downward force of 750 N to the opened upper bed on a point located 200 mm from the mid of the front edge of the foldaway bed sleeping surface. While maintaining the load on the upper bed apply to the lower bed a vertical overturning force of 750 N to the mid point of the outermost edge of the foldaway bed sleeping surface (see Figure 3). The overturning force shall be maintained for (5 ± 2) seconds.
Record if the product overturns.
oSIST prEN 1129:2026 prEN 1129:2026 (E) Dimensions in millimetres
Key 1 foldaway bed structure 2 foldaway bed sleeping surface 3 mattress 4 strap Figure 3 — Stability of free-standing foldaway multiple beds – principle 6.3.1.2.4 For foldaway beds with multiple sleeping surfaces in a structure that can be opened and closed simultaneously Block the foldaway mechanism at a 70° angle in relation to vertical with one or more strap fixed from the foldaway bed structure to the foldaway bed sleeping surface(s), or by other suitable means, without preventing lifting and/or tipping of the bed (see Figure 4).
Apply a vertical downward force of 750 N to the mid point of the front edge of the foldaway bed sleeping surface of the lower bed, (see Figure 4). The overturning force shall be maintained for (5 ± 2) seconds. Record if the product overturns.
For specific designs, e.g. where the sleeping surfaces have different dimensions, the force shall be applied at the most adverse sleeping surface (e.g. the most protruding one).
oSIST prEN 1129:2026 prEN 1129:2026 (E)
Key 1 foldaway bed structure 2 foldaway bed sleeping surface 3 mattress 4 strap 5 synchronous mechanism (principle) Figure 4 — Stability of free-standing foldaway multiple beds – principle
6.3.2 Stability - Rearward
6.3.2.1 Requirements
This requirement does not apply to beds, and their associated components (e.g. wardrobes into which the bed is mounted) that are intended to be fixed to the structure of the building. When tested in accordance with 6.3.2.2 the product shall not tip over at an angle of less than 15 degrees.
6.3.2.2 Test method
Place the product on the test floor (5.3), without mattress(es) on the sleeping surface(s). The foldaway bed shall be in closed position.
Apply a horizontal force of maximum 500 N acting rearward, from the side where the bed is opened/ manoeuvred, acting at the mid point of the width of the bed and 50 mm from the top edge of the foldaway bed but with a maximum of 1 300 mm from the floor.
If the foldaway bed starts to tilt continue applying the force until it starts to tip over or until it has moved 15 degrees from the original position. Record the maximum tilting force applied and the reached angle of movement”(see Figure 5).
oSIST prEN 1129:2026 prEN 1129:2026 (E)
Key 1 foldaway bed structure 2 rear side of the product F force applied d distance from the top edge of the foldaway bed to the point of application of F, 50 mm h distance from the floor to the point of application of F, with a maximum of 1 300 mm Figure 5 — Stability of free-standing foldaway beds to the rear side
6.4 Mounting of the bed to the building structure
6.4.1 Requirement
This requirement does not apply to beds that are intended to be free standing. Beds with a construction that rest on the floor when closed and/or whose foldaway bed sleeping surface rest directly on the floor when open shall be constructed in such a way that their fastenings meet the following requirements:
a) there shall be at least two anchor devices, and; b) there shall be at least two holes for attachment to the building structure in each of the anchor devices, and; c) the distance between the centre of any two mounting holes shall be greater than 50 mm, and; d) the design of the anchor devices shall be such that no additional stress shall be transferred to the anchor devices caused by the sagging of the floor by up to 10 mm maximum; NOTE 1 Sagging of the floor can be caused by the use of carpets or rugs for example. An anchor device with a vertical oblong hole allowing a minimum adjustment of 10 mm represents an acceptable solution if the instructions for use are explicit on the assembly of the product in order to compensate for any sagging of the product after initial assembly.
e) it shall not be possible to release the fixing devices without the use of a tool;
oSIST prEN 1129:2026 prEN 1129:2026 (E) f) the anchor devices shall be present on the outside of the foldaway bed structure; g) the force F (see 6.4.2) shall be ≥ 400 N. For safety reasons, if the calculated F is < 400 N, consider c c F as 400 N. The information of the value shall be permanently attached on the rear side of the bed
and in the installation instruction to make clear what is the relevant tensile force acting at the level and where the anchor devices are positioned.
NOTE 2 Explanation of the determination of the number of fixing points per anchor device and the verification of the fixing system can be found in Annex B.
...