Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps)

This part of the IEC 61347 series specifies particular safety requirements for electromagnetic controlgear for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductivetype electromagnetic controlgear for use on a.c. supplies up to 1000 V at 50 Hz or 60 Hz, associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in IEC 60188, IEC 60192 and IEC 60662. This standard applies to complete electromagnetic controlgear and to their component parts such as reactors, transformers and capacitors. Particular requirements for thermally protected electromagnetic controlgear are given in Annex B. For certain types of discharge lamps, an ignitor is required.

Geräte für Lampen - Teil 2-9: Besondere Anforderungen an elektromagnetische Betriebsgeräte für Entladungslampen (ausgenommen Leuchtstofflampen)

Appareillages de lampes - Partie 2-9: Exigences particulières pour les appareillages électromagnétiques pour lampes à décharge (à l'exclusion des lampes fluorescentes)

La CEI 61347-2-9:2012 donne les exigences particulières de sécurité pour les appareillages électromagnétiques pour lampes à décharge telles que lampes à vapeur de mercure à haute pression, lampes à vapeur de sodium à basse pression, lampes à vapeur de sodium à haute pression et lampes aux halogénures métalliques. La présente norme traite des appareillages électromagnétiques inductifs, pour utilisation en courant alternatif jusqu'à 1 000 V à 50 Hz ou 60 Hz, associés à des lampes à décharge dont les puissances assignées, les dimensions et les caractéristiques sont indiquées dans la CEI 60188, la CEI 60192 et la CEI 60662. Cette deuxième édition annule et remplace la première édition parue en 2000, l'Amendement 1:2003 et l'Amendement 2:2006. Cette édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente:  a) l'ajout d'un nouvel Article 14;  b) le terme 'ballast' est modifié en 'appareillage électromagnétique'.   Cette publication doit être lue conjointement avec la CEI 61347-1:2007.

Krmilne stikalne naprave za sijalke - 2-9. del: Posebne zahteve za krmilne elektromagnetne stikalne naprave za sijalke (razen fluorescenčnih sijalk)

Ta del serije IEC 61347 določa posebne varnostne zahteve za krmilne elektromagnetne stikalne naprave za sijalke, kot so visokotlačne sijalke iz živega srebra, nizkotlačne in visokotlačne natrijeve sijalke ter železne halidne sijalke. Ta standard zajema elektromagnetne stikalne naprave indukcijskega tipa, ki uporabljajo napajalnike izmenične napetosti do 1000 V pri 50 Hz ali 60 Hz, se povezujejo s sijalkami, imajo nazivne moči, dimenzije in značilnosti, ki so navedene v standardnih IEC 60188, IEC 60192 in IEC 60662. Ta standard velja za vse elektromagnetne stikalne naprave in njihove sestavne dele, kot so reaktorji, transformatorji in kondenzatorji. Posebne zahteve za elektromagnetne stikalne naprave, ki so zaščitene pred toploto, so podane v dodatku B. Določene vrste sijalk potrebujejo sprožilec.

General Information

Status
Published
Publication Date
04-Feb-2013
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
30-Jan-2013
Due Date
06-Apr-2013
Completion Date
05-Feb-2013

Relations

Buy Standard

Standard
EN 61347-2-9:2013
English language
34 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61347-2-9:2013
01-marec-2013
1DGRPHãþD
SIST EN 61347-2-9:2002
SIST EN 61347-2-9:2002/A1:2004
SIST EN 61347-2-9:2002/A2:2007
.UPLOQHVWLNDOQHQDSUDYH]DVLMDONHGHO3RVHEQH]DKWHYH]DNUPLOQH
HOHNWURPDJQHWQHVWLNDOQHQDSUDYH]DVLMDONH UD]HQIOXRUHVFHQþQLKVLMDON
Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for
discharge lamps (excluding fluorescent lamps)
Geräte für Lampen - Teil 2-9: Besondere Anforderungen an elektromagnetische
Betriebsgeräte für Entladungslampen (ausgenommen Leuchtstofflampen)
Appareillages de lampes - Partie 2-9: Exigences particulières pour les appareillages
électromagnétiques pour lampes à décharge (à l'exclusion des lampes fluorescentes)
Ta slovenski standard je istoveten z: EN 61347-2-9:2013
ICS:
29.130.01 Stikalne in krmilne naprave Switchgear and controlgear
na splošno in general
29.140.99 Drugi standardi v zvezi z Other standards related to
žarnicami lamps
SIST EN 61347-2-9:2013 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61347-2-9:2013

---------------------- Page: 2 ----------------------

SIST EN 61347-2-9:2013

EUROPEAN STANDARD
EN 61347-2-9

NORME EUROPÉENNE
January 2013
EUROPÄISCHE NORM

ICS 29.140.99 Supersedes EN 61347-2-9:2001 + corr. Jul.2003 + corr. Dec.2010 + A1:2003 + A2:2006


English version


Lamp controlgear -
Part 2-9: Particular requirements for electromagnetic controlgear for
discharge lamps (excluding fluorescent lamps)
(IEC 61347-2-9:2012)


Appareillages de lampes -  Geräte für Lampen -
Partie 2-9: Exigences particulières pour Teil 2-9: Besondere Anforderungen an
les appareillages électromagnétiques pour elektromagnetische Betriebsgeräte für
lampes à décharge (à l'exclusion des Entladungslampen (ausgenommen
lampes fluorescentes) Leuchtstofflampen)
(CEI 61347-2-9:2012) (IEC 61347-2-9:2012)





This European Standard was approved by CENELEC on 2012-12-04. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61347-2-9:2013 E

---------------------- Page: 3 ----------------------

SIST EN 61347-2-9:2013
EN 61347-2-9:2013 - 2 -
Foreword
The text of document 34C/1022/FDIS, future edition 2 of IEC 61347-2-9, prepared by SC 34C, "Auxiliaries
for lamps", of IEC TC 34, "Lamps and related equipment" was submitted to the IEC-CENELEC parallel
vote and approved by CENELEC as EN 61347-2-9:2013.
The following dates are fixed:
(dop) 2013-09-04
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2015-12-04

standards conflicting with the
document have to be withdrawn

This document supersedes EN 61347-2-9:2001 + corr. Jul.2003 + corr. Dec.2010 + A1:2003 + A2:2006.
EN 61347-2-9:2013 includes the following significant technical changes with respect to EN 61347-2-
9:2001:
a) the addition of a new Clause 14;
b) the word "ballast" is changed to "electromagnetic controlgear".
This standard shall be used in conjunction with EN 61347-1.
This Part 2-9 supplements or modifies the corresponding clauses in EN 61347-1, so as to convert that
publication into the European Standard: Particular requirements for electromagnetic controlgear for
discharge lamps (excluding fluorescent lamps).
Where the requirements of any of the clauses of EN 61347-1 are referred to in this standard by the
phrase "The requirements of clause n of EN 61347-1 apply", this phrase is interpreted as meaning that all
requirements of the clause in question of Part 1 apply, except any which are clearly inapplicable to the
specific type of lamp controlgear covered by this particular part of EN 61347-2.
NOTE In this standard, the following print types are used:

– Requirements proper: in roman type.
– Test specifications: in italic type.
– Explanatory matter: in smaller roman type.

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.

This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed
for Use within Certain Voltage Limits (LVD - 2006/95/EC).

---------------------- Page: 4 ----------------------

SIST EN 61347-2-9:2013
- 3 - EN 61347-2-9:2013
Endorsement notice
The text of the International Standard IEC 61347-2-9:2012 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60923 NOTE  Harmonized as EN 60923.
IEC 61167 NOTE  Harmonized as EN 61167.
IEC 61347-2-8 NOTE  Harmonized as EN 61347-2-8.

---------------------- Page: 5 ----------------------

SIST EN 61347-2-9:2013
EN 61347-2-9:2013 - 4 -
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC 60188 - High-pressure mercury vapour lamps - EN 60188 -
Performance specifications


IEC 60192 - Low pressure sodium vapour lamps - EN 60192 -
Performance specifications


IEC 60598-1 - Luminaires - EN 60598-1 -
Part 1: General requirements and tests


IEC 60662 - High pressure sodium vapour lamps - EN 60662 -
Performance specifications


IEC 61347-1 (mod) 2007 Lamp controlgear - EN 61347-1 2008
+ A1 2010 Part 1: General and safety requirements + A1 2011


IEC 61347-2-1 - Lamp controlgear - EN 61347-2-1 -
Part 2-1: Particular requirements for starting
devices (other than glow starters)


IEC 62035 (mod) - Discharge lamps (excluding fluorescent EN 62035 -
lamps) - Safety specifications

---------------------- Page: 6 ----------------------

SIST EN 61347-2-9:2013



IEC 61347-2-9

®


Edition 2.0 2012-10




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE











Lamp controlgear –

Part 2-9: Particular requirements for electromagnetic controlgear for discharge

lamps (excluding fluorescent lamps)




Appareillages de lampes –

Partie 2-9: Exigences particulières pour les appareillages électromagnétiques


pour lampes à décharge (à l'exclusion des lampes fluorescentes)













INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE

PRICE CODE
INTERNATIONALE

CODE PRIX V


ICS 29.140.99 ISBN 978-2-83220-431-3



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 61347-2-9:2013
– 2 – 61347-2-9 © IEC:2012
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 7
4 General requirements . 8
4.1 General . 8
4.2 Capacitors and other components . 8
4.3 Thermally protected electromagnetic controlgear . 8
5 General notes on tests . 8
6 Classification . 9
7 Marking . 9
7.1 General . 9
7.2 Mandatory markings . 9
7.3 Information to be provided, if applicable . 9
7.4 Other information . 9
8 Protection against accidental contact with live parts . 10
9 Terminals . 10
10 Provisions for earthing . 10
11 Moisture resistance and insulation . 10
12 Electric strength . 10
13 Thermal endurance test for windings . 10
14 Electromagnetic controlgear heating . 10
14.1 General . 10
14.2 Test requirements . 10
14.3 Normal operating condition . 11
14.4 Abnormal operating condition . 11
15 High-voltage impulse testing . 14
15.1 General . 14
15.2 Test for electromagnetic controlgear operating with lamp with external
starting devices . 14
15.3 Test for electromagnetic controlgear operating with lamps with internal
starting devices . 14
16 Fault conditions . 16
17 Construction . 16
18 Creepage distances and clearances . 16
19 Screws, current-carrying parts and connections . 16
20 Resistance to heat, fire and tracking . 16
21 Resistance to corrosion . 16
22 No-load output voltage . 16
Annex A (normative) Test to establish whether a conductive part is a live part which
may cause an electric shock . 17
Annex B (normative) Particular requirements for thermally protected lamp
electromagnetic controlgear . 18

---------------------- Page: 8 ----------------------

SIST EN 61347-2-9:2013
61347-2-9 © IEC:2012 – 3 –
Annex C (normative) Particular requirements for electronic lamp controlgear with
means of protection against overheating . 19
Annex D (normative) Requirements for carrying out the heating tests of thermally
protected lamp electromagnetic controlgear . 20
Annex E (normative) Use of constant S other than 4 500 in t tests . 21
w
Annex F (normative) Draught-proof enclosure . 22
Annex G (normative) Explanation of the derivation of the values of pulse voltages . 23
Annex H (normative) Tests. 24
Annex I (normative) Method for selection of varistors . 25
Annex J (informative) Explanation of electromagnetic controlgear temperatures . 26
Annex K (normative) Additional requirements for built-in electromagnetic controlgear
with double or reinforced insulation . 29
Bibliography . 30

Figure 1 – Test circuit for electromagnetic controlgear for lamps with integral starting
devices . 15
Figure J.1 – Test hood for electromagnetic controlgear heating test . 28
Figure J.2 – Test corner for electromagnetic controlgear heating . 28

Table 1 – Test voltages for electromagnetic controlgear generating pulse voltages . 10
Table 2 – Maximum temperatures . 12
Table 3 – Limiting temperatures of windings under abnormal operating conditions and
at 110 % of rated voltage for electromagnetic controlgear subjected to endurance test
duration of 30 days . 13
Table 4 – Limiting temperatures of windings under abnormal operating conditions and
at 110 % of rated voltage for electromagnetic controlgear marked D6 which are
subjected to an endurance test duration of 60 days . 13

---------------------- Page: 9 ----------------------

SIST EN 61347-2-9:2013
– 4 – 61347-2-9 © IEC:2012
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

LAMP CONTROLGEAR –

Part 2-9: Particular requirements for electromagnetic
controlgear for discharge lamps (excluding fluorescent lamps)

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61347-2-9 has been prepared by subcommittee 34C: Auxiliaries
for lamps, of IEC technical committee 34: Lamps and related equipment.
This second edition cancels and replaces the first edition published in 2000,
Amendment 1:2003 and Amendment 2:2006. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) the addition of a new Clause 14;
b) the word "ballast" is changed to "electromagnetic controlgear".

---------------------- Page: 10 ----------------------

SIST EN 61347-2-9:2013
61347-2-9 © IEC:2012 – 5 –
The text of this standard is based on the following documents:
FDIS Report on voting
34C/1022/FDIS 34C/1028/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
This standard shall be used in conjunction with IEC 61347-1.
This Part 2-9 supplements or modifies the corresponding clauses in IEC 61347-1, so as to
convert that publication into the IEC Standard: Particular requirements for electromagnetic
controlgear for discharge lamps (excluding fluorescent lamps).
Where the requirements of any of the clauses of IEC 61347-1 are referred to in this standard
by the phrase "The requirements of clause n of IEC 61347-1 apply", this phrase is interpreted
as meaning that all requirements of the clause in question of Part 1 apply, except any which
are clearly inapplicable to the specific type of lamp controlgear covered by this particular part
of IEC 61347-2.
NOTE In this standard, the following print types are used:
– Requirements proper: in roman type.
– Test specifications: in italic type.
– Explanatory matter: in smaller roman type.
A list of all parts of the IEC 61347 series, published under the general title Lamp controlgear,
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

---------------------- Page: 11 ----------------------

SIST EN 61347-2-9:2013
– 6 – 61347-2-9 © IEC:2012
INTRODUCTION
This second edition of IEC 61347-2-9 is published in conjunction with IEC 61347-1. The
formatting into separately published parts provides for ease of future amendments and
revisions. Additional requirements will be added as and when a need for them is recognized.
This standard, and the parts which make up IEC 61347-2, in referring to any of the clauses of
IEC 61347-1, specify the extent to which such a clause is applicable and the order in which
the tests are to be performed; they also include additional requirements, as necessary. All
parts which make up IEC 61347-2 are self-contained and, therefore, do not include references
to each other.

---------------------- Page: 12 ----------------------

SIST EN 61347-2-9:2013
61347-2-9 © IEC:2012 – 7 –
LAMP CONTROLGEAR –

Part 2-9: Particular requirements for electromagnetic
controlgear for discharge lamps (excluding fluorescent lamps)



1 Scope
This part of the IEC 61347 series specifies particular safety requirements for electromagnetic
controlgear for discharge lamps such as high-pressure mercury vapour, low-pressure sodium
vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductive-
type electromagnetic controlgear for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz,
associated with discharge lamps, having rated wattages, dimensions and characteristics as
specified in IEC 60188, IEC 60192 and IEC 60662.
This standard applies to complete electromagnetic controlgear and to their component parts
such as reactors, transformers and capacitors. Particular requirements for thermally protected
electromagnetic controlgear are given in Annex B.
For certain types of discharge lamps, an ignitor is required.
NOTE Electromagnetic controlgear for fluorescent lamps are covered by IEC 61347-2-8.
Performance requirements are the subject of IEC 60923.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60188, High-pressure mercury vapour lamps – Performance specifications
IEC 60192, Low-pressure sodium vapour lamps – Performance specifications
IEC 60598-1, Luminaires – Part 1: General requirements and tests
IEC 60662, High-pressure sodium vapour lamps – Performance specifications
IEC 61347-1:2007, Lamp controlgear – Part 1: General and safety requirements
Amendment 1:2010
IEC 61347-2-1, Lamp controlgear – Part 2-1: Particular requirements for starting devices
(other than glow starters)
IEC 62035, Discharge lamps (excluding fluorescent lamps) – Safety specifications
3 Terms and definitions
For the purpose of this document, the terms and definitions given in IEC 61347-1:2007,
together with the following apply:

---------------------- Page: 13 ----------------------

SIST EN 61347-2-9:2013
– 8 – 61347-2-9 © IEC:2012
3.1
rated temperature rise of an electromagnetic controlgear winding
∆t
temperature rise assigned by the manufacturer under the conditions specified in this standard
Note 1 to entry: The specifications for the supply and mounting conditions of the electromagnetic controlgear are
given in Annex H.
3.2
high-voltage impulse
intentionally applied periodic transient voltage which rises rapidly to a peak value and then
falls, usually less rapidly, to zero
Note 1 to entry: The term "impulse" is to be distinguished from the term "surge", which refers to transients
occurring in electrical equipment or networks in service.
Note 2 to entry: Such an impulse is, in general, well represented by the sum of two exponentials.
4 General requirements
4.1 General
The requirements of Clause 4 of IEC 61347-1:2007 apply, together with the following
additional requirements:
4.2 Capacitors and other components
Capacitors and other components incorporated in electromagnetic controlgear shall comply
with the requirements of the appropriate IEC standard.
4.3 Thermally protected electromagnetic controlgear
Thermally protected electromagnetic controlgear shall comply with the requirements of
Annex B.
5 General notes on tests
The requirements of Clause 5 of IEC 61347-1:2007 apply, together with the following
additional requirements:
The type test is carried out on one sample consisting of eight electromagnetic controlgear
submitted for the purpose of the type test. Seven electromagnetic controlgear are for the
endurance test and one for all other tests. For conditions of compliance for the endurance
test, see Clause 13.
In addition, six electromagnetic controlgear are required for the high-voltage impulse testing
according to Clause 15 below, for electromagnetic controlgear for metal halide and high-
pressure sodium lamps. There shall be no failure during the test.
The tests are made under the conditions specified in Annex H of IEC 61347-1:2007. In
general, all the tests are carried out on each type of electromagnetic controlgear or, where a
range of similar electromagnetic controlgear is involved, on each rated power in the range, or
on a representative selection from the range as agreed with the manufacturer. A reduction in
the number of samples for the endurance test according to Clause 13 and including the use of
constant S other than 4 500 as shown in Annex E, or even the omission of these tests, is
allowed when electromagnetic controlgear of the same construction but with different
characteristics are submitted together for approval, or when test reports from the
manufacturer or other authority are accepted by the testing station.

---------------------- Page: 14 ----------------------

SIST EN 61347-2-9:2013
61347-2-9 © IEC:2012 – 9 –
6 Classification
The requirements of Clause 6 of IEC 61347-1:2007 apply.
7 Marking
7.1 General
Electromagnetic controlgear which form an integral part of the luminaire need not be marked.
For electromagnetic controlgear intended to be mounted in the base compartment of a
column, all necessary markings according to 7.2 and 7.3 shall be on the electromagnetic
controlgear. The requirements of 7.2 of IEC 61347-1:2007 apply.
7.2 Mandatory markings
Electromagnetic controlgear, other than integral electromagnetic controlgear, shall be clearly
and durably marked with the following mandatory markings:
– items a), b), e), f), g) and r) of 7.1 of IEC 61347-1:2007, together with:
– in the case of electromagnetic controlgear intended to be used with ignitors
(IEC 61347-2-1), the terminals/terminations s
...