SIST EN 15102:2019
(Main)Decorative wallcoverings - Roll form
Decorative wallcoverings - Roll form
This European Standard applies to all forms of wallcovering products in roll form supplied for hanging onto internal walls, partitions or ceilings, by means of an adhesive, whose primary purpose is decorative. However, certain wallcovering products may confer minor sound absorption and thermal resistance properties.
It also provides for the evaluation of conformity and the assessment and verification of constancy of performance (AVCP) of products to the requirements of this standard.
It does not apply to wallcoverings whose primary purpose is structural or protective (e.g. vapour or moisture).
Dekorative Wandbekleidungen - Rollen
Diese Europäische Norm gilt für alle Formen von Wandbekleidungsprodukten in Rollen, die vorrangig zu dekorativen Zwecken an Innenwände, Trennwände oder Decken angeklebt werden. Bestimmte Wandbekleidungsprodukte können jedoch auch geringfügig zur Schallabsorption und zum Wärmedurchlasswiderstand beitragen.
Darüber hinaus wird die Bewertung der Konformität und die Bewertung und Überprüfung der Leistungsbeständigkeit (AVCP) der Produkte mit den Anforderungen dieser Norm festgelegt.
Die Norm gilt nicht für Wandbekleidungen, die vorwiegend einen baulichen oder einen Schutzzweck erfüllen (z. B. Dampf oder Feuchtigkeit).
Revêtements muraux décoratifs - Rouleaux
La présente Norme européenne s'applique à tous les types de produits de revêtement mural sous forme de rouleaux destinés à être posés sur les murs intérieurs, les cloisons ou les plafonds au moyen d'une colle et dont la vocation est principalement décorative. Toutefois, certains produits de revêtement mural peuvent conférer des propriétés mineures d'absorption acoustique et de résistance thermique.
La présente norme prévoit également l’évaluation de la conformité des produits, ainsi que l'évaluation et la vérification de la constance de leurs performances, conformément aux exigences de la présente norme.
Elle ne s'applique pas aux revêtements muraux dont la principale fonction est structurale ou protectrice (par exemple, écrans pare-vapeur ou pare-humidité).
Dekorativne stenske obloge - Zvitki
Ta evropski standard se uporablja za vse stenske obloge v obliki zvitkov, namenjene za obešanje na notranje stene, predelne stene ali strope z lepilom, katerih prvotni namen je dekorativen. Kljub temu pa lahko določene stenske obloge zagotavljajo manjšo absorbcijo zvoka in slabše lastnosti toplotne upornosti.
Podaja tudi vrednotenje skladnosti ter ocenjevanje in preverjanje stalnosti delovanja (AVCP) izdelkov z zahtevami tega standarda.
Ne uporablja se za stenske obloge, katerih prvotni namen je konstrukcijski ali zaščitni (npr. pred paro ali vlago).
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 15102:2019
01-september-2019
Nadomešča:
SIST EN 15102:2008+A1:2011
Dekorativne stenske obloge - Zvitki
Decorative wallcoverings - Roll form
Dekorative Wandbekleidungen - Rollen
Revêtements muraux décoratifs - Rouleaux
Ta slovenski standard je istoveten z: EN 15102:2019
ICS:
91.180 Notranja zaključna dela Interior finishing
SIST EN 15102:2019 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 15102:2019
---------------------- Page: 2 ----------------------
SIST EN 15102:2019
EN 15102
EUROPEAN STANDARD
NORME EUROPÉENNE
June 2019
EUROPÄISCHE NORM
ICS 91.180 Supersedes EN 15102:2007+A1:2011
English Version
Decorative wallcoverings - Roll form
Revêtements muraux décoratifs - Rouleaux Dekorative Wandbekleidungen - Rollen
This European Standard was approved by CEN on 7 October 2018.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 15102:2019 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN 15102:2019
EN 15102:2019 (E)
Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 6
4 Product's characteristics . 7
4.1 Reaction to fire . 7
4.1.1 General . 7
4.1.2 Classification without testing . 7
4.1.3 Classification based on test results . 8
4.2 Release and emission of formaldehyde . 8
4.2.1 General . 8
4.2.2 Assessment without testing . 8
4.2.3 Assessment based on test results . 9
4.3 Migration of heavy metals and specific elements . 9
4.3.1 General . 9
4.3.2 Assessment without testing . 9
4.3.3 Assessment based on test results . 9
4.4 Release of vinyl chloride monomer . 10
4.4.1 General . 10
4.4.2 Assessment without testing . 10
4.4.3 Assessment based on test results . 11
4.5 Content of specific dangerous substances. 11
4.5.1 General . 11
4.5.2 Assessment without testing . 11
4.5.3 Assessment based on test results . 11
4.6 Emission of other dangerous substances into indoor air . 12
4.6.1 General . 12
4.6.2 Assessment without testing . 12
4.6.3 Assessment based on test results . 12
4.7 Sound absorption . 12
4.8 Thermal resistance . 13
5 Assessment and verification of constancy of performance (AVCP) . 13
5.1 General . 13
5.2 Type testing . 13
5.2.1 General . 13
5.2.2 Test samples, testing and compliance criteria . 14
5.2.3 Test reports . 15
5.2.4 Shared other party results . 16
5.2.5 Cascading determination of the product type results . 16
5.3 Factory production control (FPC) . 17
5.3.1 General . 17
5.3.2 Requirements . 18
5.3.3 Product specific requirements . 20
5.3.4 Initial inspection of the manufacturing plant and of FPC . 21
5.3.5 Continuous surveillance, assessment and validation of FPC . 21
2
---------------------- Page: 4 ----------------------
SIST EN 15102:2019
EN 15102:2019 (E)
5.3.6 Procedure for modifications . 21
5.3.7 One-off products, pre-production products (e.g. prototypes) and products produced
in very low quantity . 22
6 Marking, labelling and packaging . 22
Annex A (normative) Extended application rules within a group of product for the reaction
to fire tests . 23
Annex B (informative) Information to be provided in the supplier's declaration on
dangerous substances in raw materials or constituent products . 25
Annex ZA (informative) Relationship of this European Standard with Regulation (EU)
No.305/2011 . 28
Bibliography . 33
3
---------------------- Page: 5 ----------------------
SIST EN 15102:2019
EN 15102:2019 (E)
European foreword
This document (EN 15102:2019) has been prepared by Technical Committee CEN/TC 99
“Wallcoverings”, the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by December 2019 and conflicting national standards shall
be withdrawn at the latest by December 2019.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 15102:2007+A1:2011.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association.
For relationship with Regulation No 305/2011, see informative Annex ZA, which is an integral part of this
document.
The significant technical changes between this European Standard and the previous edition are listed
below:
— changes of Annex ZA according to the new model;
— changes concerning the dangerous substances;
— suppression of the wallcoverings in panels form from the standard.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands,
Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
the United Kingdom.
4
---------------------- Page: 6 ----------------------
SIST EN 15102:2019
EN 15102:2019 (E)
1 Scope
This document applies to wallcoverings in roll form supplied for hanging onto internal walls, partitions
or ceilings, by means of an adhesive, whose primary purpose is decorative. However, certain
wallcoverings in roll form may confer minor sound absorption and thermal resistance properties.
The European Standards for wallcoverings in roll form to which this document relates, and which provide
additional product definitions and requirements, include the following:
— finished wallpapers, wall vinyls and plastics wallcoverings (EN 233);
— wallcoverings for subsequent decoration (EN 234);
— textile wallcoverings (EN 266);
— Cork rolls (EN 13085);
— heavy duty wallcoverings (EN 259-1).
This document also provides for the assessment and verification of constancy of performance (AVCP) of
characteristics and marking of these products.
It does not apply to wallcoverings whose primary purpose is structural or protective.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 1122:2001, Plastics — Determination of cadmium —Wet decomposition method
EN 12149:1997, Wallcoverings in roll form - Determination of migration of heavy metals and certain other
elements, of vinyl chloride monomer and of formaldehyde release
EN 12667:2001, Thermal performance of building materials and products — Determination of thermal
resistance by means of guarded hot plate and heat flow meter methods — Products of high and medium
thermal resistance
EN 13238:2010, Reaction to fire tests for building products — Conditioning procedures and general rules
for selection of substrates
EN 13501-1:2018, Fire classification of construction products and building elements — Part 1:
Classification using data from reaction to fire tests
EN 13823:2010+A1:2014, Reaction to fire tests for building products — Building products excluding
floorings exposed to the thermal attack by a single burning item
EN 16516:2017, Construction products: Assessment of release of dangerous substances — Determination of
emissions into indoor air
CEN/TS 15968:2010, Determination of extractable perfluorooctanesulphonate (PFOS) in coated and
impregnated solid articles, liquids and fire fighting foams — Method for sampling, extraction and analysis
by LC-qMS or LC-tandem/MS
EN ISO 354:2003, Acoustics — Measurement of sound absorption in a reverberation room (ISO 354:2003)
5
---------------------- Page: 7 ----------------------
SIST EN 15102:2019
EN 15102:2019 (E)
EN ISO 10456:2007, Building materials and products — Hygrothermal properties — Tabulated design
values and procedures for determining declared and design thermal values (ISO 10456:2007)
1)
EN ISO 11654:1997 , Acoustics — Sound absorbers for use in buildings — Rating of sound absorption (ISO
11654:1997)
EN ISO 11925-2:2010, Reaction to fire tests — Ignitability of products subjected to direct impingement of
flame — Part 2: Single-flame source test (ISO 11925-2:2010)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— IEC Electropedia: available at http://www.electropedia.org/
— ISO Online browsing platform: available at http://www.iso.org/obp
3.1
product group
range of products within defined limits of variability (defined by the manufacturer or a technical
specification) of the product parameters and, if relevant, end-use parameters, for which the reaction to
fire performance remains unchanged (does not get worse)
3.2
product parameter
aspect of a product which can vary and have an influence on the product's performance, for example,
reaction to fire
Note 1 to entry: It covers aspects such as thickness, composition, density.
3.3
end use application
real application of a product, in relation to all aspects that influence the behaviour of that product under
different fire situations
Note 1 to entry: It covers aspects such as its quantity, its orientation, its position in relation to other adjacent
products and its method of fixing as given in the relevant standards, referred in EN 13501-1:2018.
3.4
use application parameter
aspect of the mounting and fixing arrangement of a product reflecting/simulating its end-use application
which can affect the fire performance
Note 1 to entry: It covers aspects such as type of substrate, fixing method, position and type of joints.
1) EN ISO 11654 is currently under revision.
6
---------------------- Page: 8 ----------------------
SIST EN 15102:2019
EN 15102:2019 (E)
4 Product's characteristics
4.1 Reaction to fire
4.1.1 General
The reaction to fire performance of the wallcoverings in roll form shall be classified in accordance with
the requirements of EN 13501-1:2018, either:
a) without the need for testing (Classification without testing – CWT), as specified in 4.1.2, when
meeting the requirements, specified therein, or otherwise
b) based on results of the test(s) of the wallcoverings in roll form, as specified in 4.1.3.
NOTE Applicable when the wallcoverings in roll form does not meet the requirements referred to in a) or
where a higher class than the one referred to therein is sought.
4.1.2 Classification without testing
The reaction to fire performance of a given type of wallcoverings in roll form may be expressed as class
2)
D-s3,d2, when meeting the corresponding requirements specified in Table 1
Table 1 — Classes of reaction to fire performance for decorative wallcoverings in roll form
a Maximu Maximu b
Product Class
m mass m
per unit thickness
area mm
2
g/m
Wallcoverings on cellulose fibre base 190 0,9
Wallcoverings on cellulose fibre base and polymer 470 0,7
coated or printed
Wallcoverings on a mixture of cellulose and polyester 160 0,3
fibre base
Wallcoverings on a mixture of cellulose and polyester 410 0,5
D-s3, d2
fibre base and polymer coated or printed
Wallcoverings on polymer coated fabric base 510 0,7
Wallcoverings of woven textile with a backing consisting 450 0,8
of cellulose fibre or cellulose and polyester fibre
Wallcoverings of foamed PVC with a backing consisting 310 1,8
of cellulose fibre or cellulose and polyester fibre
a
Products in accordance with European standard mounted on a substrate of at least class A2-s1,d0
3
with a minimum thickness 12 mm and with minimum density 800 kg/m using starch, or starch/PVA, or
2
cellulose/PVA adhesive applied at a maximum 200 g/m .
b
Class as provided for in Table 1 of the Annex to Commission Delegated Regulation (EU) 2016/364.
2) This table is the same as Table in the Annex of the Commission Decision 2010/82/EU of 2010-02-09 (see OJEU
L038 of 2010-02-11).
7
---------------------- Page: 9 ----------------------
SIST EN 15102:2019
EN 15102:2019 (E)
4.1.3 Classification based on test results
4.1.3.1 General
4.1.3.1.1 The reaction to fire performance of a given type of the wallcoverings in roll form shall be
determined on a base of results of the test(s), using standard(s), which is/are indicated for a specific
reaction to fire class in EN 13501-1:2018, with exception of the class F, for which test shall be performed
in accordance with EN ISO 11925-2:2010.
Before certain of such test(s) is performed, the test pieces shall be conditioned according to 4.1.3.2 and
selected according to 4.1.3.3.
4.1.3.1.2 Based on the test results obtained, the reaction to fire performance of a given type of
wallcoverings in roll form shall be classified according to EN 13501-1:2018 and expressed as the class
achieved.
When the SBI test is to be performed in accordance with EN 13823:2010+A1:2014, also the name of the
3
product used in the test as substrate, together with its reaction to fire class and density (kg/m ), and
2
adhesive coating weight (g/m ), shall be added to the class expressed.
4.1.3.2 Specimen preparation and conditioning
The test pieces of wallcoverings in roll form shall be conditioned prior to the test in accordance with
EN 13238:2010.
4.1.3.3 Extended application rules
When defining a product family of a particular type of the wallcoverings in roll form with regard to its
reaction to fire performance, the product’s parameters, influencing such performance, as given in
Annex A, shall be taken into account.
4.2 Release and emission of formaldehyde
4.2.1 General
If formaldehyde is neither actively added in manufacturing process of the wallcoverings in roll form nor
found in any of their raw materials and it is not known to occur in any stage of their production process,
the performance of wallcoverings in roll form shall be assessed and expressed as:
a) release/emission of formaldehyde, without testing, as specified in 4.2.2, if this is proved to be the
case (i.e. by manufacturer's/ suppliers' declaration(s)), or otherwise
NOTE In Annex B, guidance is given on such supplier's declarations or manufacturer's declaration.
b) release of formaldehyde and/or emission of formaldehyde, both based on test results, as specified
separately in 4.2.3.
4.2.2 Assessment without testing
Such wallcoverings in roll form are deemed to satisfy the requirements and the performance of release /
emission of formaldehyde from them may be assessed without the need for testing (CWT) and expressed
as “compliant”.
8
---------------------- Page: 10 ----------------------
SIST EN 15102:2019
EN 15102:2019 (E)
4.2.3 Assessment based on test results
The performance of release of formaldehyde from wallcoverings in roll form shall be assessed and
expressed based on results on one of the following test options, as:
a) release of formaldehyde, in accordance with EN 12149:1997, Clause 6 (Test C), and if the value
is ≤ 120 mg/kg, expressed as indication “≤ 120 mg/kg”, or
3
b) emission of formaldehyde, in accordance with EN 16516:2017 and expressed as a value in µg/m .
4.3 Migration of heavy metals and specific elements
4.3.1 General
If none of the heavy metals and specific elements, listed in Table 2, is actively added in manufacturing
process of the wallcoverings in roll form or found in any of their raw materials and it is not known that it
may occur in any stage of their production process, the performance of migration of the heavy metals and
specific elements from wallcoverings in roll form shall be assessed and expressed, as specified:
a) in 4.3.2, if this is proved to be the case (i.e. by manufacturer's/ suppliers' declaration(s)), and/or
NOTE In Annex B, guidance is given on such supplier's declarations or manufacturer's declaration.
b) in 4.3.3, otherwise.
4.3.2 Assessment without testing
Such wallcoverings in roll form are deemed to satisfy the requirements and the performance of migration
of the heavy metals and specific elements from them, as listed in Table 2, may be assessed without the
need for testing (CWT) and expressed as “compliant”.
4.3.3 Assessment based on test results
4.3.3.1 For performance of migration of any of the heavy metals or specific elements from
wallcoverings in roll form, as listed in Table 2, the following values (both in mg/kg), shall be determined:
a) an analytical value, A, obtained in the test performed in accordance with EN 12149:1997, Clause 4
(Test A), and
b) a corrected value, C, calculated according the following Equation, where B is analytical correction
factor from Table 3 for the corresponding heavy metal or specific element:
C = A – (A × B)/100
EXAMPLE Analytical result for lead (A) is 120 and corresponding analytical correction factor in Table 3 (B) 30 %.
Corrected analytical value, C = 120 – (120 × 30)/100 = 120 – 36 = 84 mg/kg ≤ 90 mg/kg.
This is regarded as satisfying the respective maximum migration requirement, specified in Table 2.
9
---------------------- Page: 11 ----------------------
SIST EN 15102:2019
EN 15102:2019 (E)
Table 2 — Maximum migration of heavy metals and specific elements of wallcoverings in roll
form
Heavy metal or Symbol Maximum migration
specific element
mg/kg
Antimony Sb -
Arsenic As 25
Barium Ba 500
Cadmium Cd 25
Chromium Cr 60
Lead Pb 90
Mercury Hg 20
Selenium Se 165
Table 3 — Analytical correction factor
Heavy metal or specific element Sb As Ba Cd Cr Pb Hg Se
Analytical correction factor, B, in % 60 60 30 30 30 30 50 60
4.3.3.2 The corrected analytical value of migration of any of the heavy metals and specific elements
from wallcoverings in roll form, as listed in Table 2, except of Antimony (Sb), shall not exceed the related
maximum migration value, specified in Table 2 and if so, the performance expressed as “compliant”.
4.3.3.3 For performance of migration of Antimony (Sb) from wallcoverings in roll form, its corrected
analytical value (in mg/kg) shall be expressed.
4.4 Release of vinyl chloride monomer
4.4.1 General
If either polyvinyl chloride or products containing vinyl chloride is not actively added in manufacturing
process of the wallcoverings in roll form or the raw materials used for them are proved to contain less
than 1 mg/kg of vinyl chloride monomer, the performance of release of vinyl chloride monomer from
wallcoverings in roll form shall be assessed and expressed, as specified:
a) in 4.4.2, if this is proved to be the case (i.e. by manufacturer's/ suppliers' declaration(s)), or
NOTE In Annex B, guidance is given on such supplier's declarations or manufacturer's declaration.
b) in 4.4.3, otherwise.
1 kg of PVC raw material should not have more than 1 mg of vinyl chloride monomer.
4.4.2 Assessment without testing
Such wallcoverings in roll form are deemed to satisfy the requirements and the performance of release
of vinyl chloride monomer from them may be assessed without the need for testing (CWT) and expressed
as “compliant”.
10
---------------------- Page: 12 ----------------------
SIST EN 15102:2019
EN 15102:2019 (E)
4.4.3 Assessment based on test results
The performance of release of vinyl chloride monomer from wallcoverings in roll form shall be assessed
by testing in accordance with EN 12149:1997, Clause 5 (Test B). If the value obtained does not exceed
0,2 mg/kg of wallcovering the performance shall be expressed as “compliant”.
4.5 Content of specific dangerous substances
4.5.1 General
If none of the specific dangerous substances, listed in Table 4, is/are actively added in manufacturing
process of the wallcoverings in roll form or found in any of their raw materials and it is not known that
they may occur in any stage of their production process, the performance of wallcoverings in roll form of
any of these specific dangerous substance shall be assessed and expressed, as specified:
a) in 4.5.2, if this is proved to be the case (i.e. by manufacturer's/ suppliers' declaration(s)), and/or
NOTE In Annex B, guidance is given on such supplier's declarations or manufacturer's declaration.
b) in 4.5.3, as relevant, otherwise.
4.5.2 Assessment without testing
Such wallcoverings in roll form are deemed to satisfy the requirements and the performance of content
of specific dangerous substances, listed in Table 4, may be assessed without the need for testing (CWT)
and expressed as “compliant”.
4.5.3 Assessment based on test results
The content of any of specific dangerous substances listed in Table 4, shall be determined using the
respective test method and the result obtained evaluated against the respective threshold limit value,
both also specified in Table 4, and if so, the performance expressed as “compliant”.
Table 4 — Specific dangerous substances content in wallcoverings in roll form
Substances CAS number Test methods Threshold limit
values
(in mg/kg)
Cadmium 7440–43–9 EN 1122:2001 ≤ 100
Lead 7439–92–1 EN 1122:2001 ≤ 1 000
Perfluorooctanoic acid (PFOA), salts and esters 335–67–1 CEN/TS 15968:2010 ≤ 1 000
of PFOA
Perfluorooctane sulfonic acid (PFOS) and its 1763–23–1 CEN/TS 15968:2010 ≤ 1 000
derivatives
11
---------------------- Page: 13 ----------------------
SIST EN 15102:2019
EN 15102:2019 (E)
4.6 Emission of other dangerous substances into indoor air
4.6.1 General
If none of the dangerous substances, listed in Table 5, is/are actively added in manufacturing process of
the wallcoverings in roll form or found in any of their raw materials and it is not known that they may
occur in any stage of their production process, the performance of wallcoverings in roll form of any of
these dangerous substance into indoor air shall be assessed and expressed, as spec
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.