kSIST FprEN 196-10:2026
(Main)Methods of testing cement - Part 10: Determination of the water-soluble chromium (VI) content of cement
- Abstract
This document specifies the method for the determination of the water-soluble chromium (VI) content of cement.
A reference method is described consisting of two stages, an extraction procedure and an analysis of the filtered extract. Guidance on other extraction procedures, suitable for screening tests, for factory production control or other purposes, is given but in case of dispute or failure to comply with a regulatory limit only the reference method is used. The reference method has alternatives whereby the filtered extract can be subjected to an oxidation step or not. The criteria by which the appropriate procedure is selected are set down. Other instrumental procedures can be used for the analysis of the filtered extract provided they are calibrated against the analysis of the filtered extract using the reference procedure. In the case of a dispute, only the reference method is used.
This document specifies, for the determination of water-soluble chromium (VI) in the filtered extract, the reference methods (colorimetric determination by diphenylcarbazide in acidic conditions) and another method for the determination of total water-soluble chromium (VI) (by inductively coupled plasma optical emission spectroscopy, ICP-OES).
The ICP-OES determines the total chromium content independently of the chemical species, i.e. whether it is present as chromium (III) or chromium (VI), for example. Experience has demonstrated that soluble chromium (VI) is predominantly present during the processing phase, such that, in most cases, the determination of total water-soluble chromium (VI) effectively reflects the chromium (VI) content. The water-soluble chromium (VI) content of cement can therefore be assessed conservatively using the method based on ICP-OES described in this document.
In the case of a dispute, only the reference methods are used. This document specifies a method that applies to cements.
NOTE 1 Annex A provides guidance on the possible application of this document to the determination of the water-soluble chromium (VI) content of cement-containing preparations.
NOTE 2 Annexes B and C provide information on other test procedures based on paste extraction and thus depart from the performance of cement in its normal conditions of use. They can be carried out with or without the oxidation process. It is important that users are aware that results using these methods can be significantly different to those obtained by the reference method. In the case of dispute or failure to comply with the regulatory limit, only the reference method is used.
NOTE 3 Annex D provides guidance on a method for determination of the excess reducing agent content of cement as used in the factory internal control system of some countries. It is important that manufacturers using such an internal control method ensure themselves of the relevance of results in comparison with testing by the reference method.
- Status
- Not Published
- Public Enquiry End Date
- 18-Dec-2025
- Technical Committee
- CAA - Mineral binders and masonry
- Current Stage
- 5020 - Formal vote (FV) (Adopted Project)
- Start Date
- 02-Sep-2026
- Due Date
- 21-Oct-2026
kSIST FprEN 196-10:2026 is a CEN standard for determining the water-soluble chromium (VI) content of cement. It specifies a reference method based on mortar extraction and colorimetric analysis of the filtered extract, and it also gives an ICP-OES route for determining total water-soluble chromium in the extract. The standard is used for cement testing, factory production control, and compliance work where chromium (VI) limits matter.
What does kSIST FprEN 196-10:2026 specify?
kSIST FprEN 196-10:2026 specifies a test method for cements, with the main reference route built from two stages: extraction and analysis of the filtered extract. In practice, that means the cement is first brought into a mortar under defined conditions, then the extract is measured for water-soluble chromium (VI).
The document also gives guidance on screening tests and other extraction procedures for factory production control or other purposes, but the reference method is the one used for disputes and for checking compliance with a regulatory limit. The standard also includes an alternative analytical route using inductively coupled plasma optical emission spectroscopy (ICP-OES) for total water-soluble chromium in the filtrate.
| Annex | What it covers |
|---|---|
| Annex A | Possible application to cement-containing preparations |
| Annex B | Screening test method using paste extraction, based on DS 1020:1984 |
| Annex C | Screening test method using paste extraction, based on TRGS 613 |
| Annex D | Photometric determination of chromium reduction capacity in cements |
| Annex E | Preparation of standard calibration solution |
What are the key requirements of kSIST FprEN 196-10:2026?
kSIST FprEN 196-10:2026 sets out a defined laboratory sequence: prepare a homogeneous cement sample, extract chromium into a mortar or other specified extract, then measure the filtered extract by the chosen analytical route. The practical point is that timing, filtration, calibration, and blank correction all affect the result, so the procedure has to be followed closely.
Sampling, test count, and blank correction
Clause 7 requires a homogeneous test sample from the laboratory sample, prepared quickly and kept exposed to air for the shortest possible time. Clause 4 requires duplicate testing when the result is not part of a statistically controlled series, while a dispute requires two tests. Clause 4.4 also requires a blank determination using the same reagents and procedure but without a sample, so the analytical result can be corrected.
Extraction by mortar and filtration
Clause 8 uses a mortar made from cement, sand and water in defined proportions, mixed in a prescribed sequence. This matters because the method is designed to approximate normal cement use rather than an artificial chemical extraction. The filtrate is obtained under vacuum through a suitable filter medium, and the standard allows alternative filtration only when needed for turbidity, provided the alternative is reported.
Colorimetric reference method
Clause 9 gives the reference analysis using s-diphenylcarbazide in acidic conditions and measurement at 540 nm. The method has two paths - with oxidation and without oxidation - because some cements contain reducing species that interfere with the colorimetric reaction. The standard requires an initial comparison of the two paths; if the results behave as the same population, later testing can use the no-oxidation route, and if not, the route giving the higher result is used.
ICP-OES route
Clause 13 describes an alternative method for total water-soluble chromium by ICP-OES. This route does not depend on chromium species, so it measures chromium in the filtrate regardless of whether it is present as chromium (III) or chromium (VI). In practice, this gives a conservative assessment of chromium (VI) where soluble chromium (VI) is the relevant concern, but the reference method remains the one used in disputes.
Calculation, reporting, and precision
Clause 10 gives the calculation of water-soluble chromium (VI) content from the measured concentration, dilution factors, and sample mass. Clause 11 requires reporting to four decimal places in percent by mass of cement as received, and Clause 12 gives repeatability and reproducibility data for a defined concentration range. For the ICP-OES route, Clauses 16 to 18 give the same style of result expression, reporting, and precision statements.
What terms does kSIST FprEN 196-10:2026 define?
kSIST FprEN 196-10:2026 defines the key laboratory terms used to prepare calibration solutions and judge precision. These definitions matter because they control how instruments are calibrated and how results are compared between laboratories.
- Analyte - the element to be determined.
- Calibration solution - a solution used to calibrate the instrument, prepared from stock solutions and adjusted as needed with acids, buffer, reference element and salts.
- Stock solution - a solution with accurately known analyte concentration, prepared from pure chemicals; certified commercial standard solutions can also be used.
- Blank test solution - a solution prepared like the test sample solution but without the test portion.
- Calibration check solution - a separate solution of known concentration used to verify the calibration.
- Calibration blank solution - a solution prepared like the calibration standards but without the analyte.
- Repeatability - precision under the same method, same laboratory, same operator and same equipment over a short time.
- Reproducibility - precision under the same method on the same material in different laboratories with different operators and equipment.
Who uses kSIST FprEN 196-10:2026?
kSIST FprEN 196-10:2026 is used by cement producers, testing laboratories, and conformity assessment bodies that need to measure water-soluble chromium (VI) in cement. It is also used in factory production control, where quick screening or internal checks may be compared with the reference method.
Quality managers and buyers use this standard when they need a defensible test result for regulatory or contractual purposes. Annex A also makes it relevant to users working with cement-containing preparations, while Annex D is aimed at manufacturers using internal control of chromium reduction capacity.
What changed in kSIST FprEN 196-10:2026 from the previous edition?
kSIST FprEN 196-10:2026 supersedes EN 196-10:2016. The stated significant technical change is the introduction of ICP-OES for determining water-soluble chromium in the filtrate, which allows analysis without an oxidation step.
Which standards are used with kSIST FprEN 196-10:2026?
kSIST FprEN 196-10:2026 cites EN 196-1 for the mortar mixer and the sand used in the extraction stage, and EN 196-7 for taking and preparing the cement sample. Those two standards support the sample preparation and extraction conditions that the chromium test depends on.
The introduction also refers to EN 197-10 as the scheme for assessing conformity with the regulatory limit for water-soluble hexavalent chromium. In practice, EN 196-10 provides the test result, while EN 197-10 provides the conformity framework.
What does the kSIST FprEN 196-10:2026 document contain?
kSIST FprEN 196-10:2026 contains the full laboratory procedure, from sample preparation through extraction, filtration, measurement, calculation and reporting. It includes calibration curves, blank determinations, precision statements, and a calculation formula for converting measured concentration into cement content.
The document also contains an ICP-OES analytical route, including sample dilution, calibration practice, measuring instructions, and quality checks during a run. Annex E gives example calibration-solution preparations, while Annex B and Annex C provide screening methods based on paste extraction for users who need alternative checks outside the reference method.
Annex A explains how the method may be applied to cement-containing preparations, including adaptations for water content, filtration, and reporting basis. Annex D gives a separate photometric method for chromium reduction capacity, which some factories use as an internal control tool.
Relations
- Effective Date
- 20-Nov-2024
Get Certified
Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)
German Institute for Building Technology.
DIN CERTCO
DIN Group product certification.

Aboma Certification B.V.
Specialized in construction, metal, and transport sectors.
Sponsored listings
Frequently Asked Questions
kSIST FprEN 196-10:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Methods of testing cement - Part 10: Determination of the water-soluble chromium (VI) content of cement". This standard covers: This document specifies the method for the determination of the water-soluble chromium (VI) content of cement. A reference method is described consisting of two stages, an extraction procedure and an analysis of the filtered extract. Guidance on other extraction procedures, suitable for screening tests, for factory production control or other purposes, is given but in case of dispute or failure to comply with a regulatory limit only the reference method is used. The reference method has alternatives whereby the filtered extract can be subjected to an oxidation step or not. The criteria by which the appropriate procedure is selected are set down. Other instrumental procedures can be used for the analysis of the filtered extract provided they are calibrated against the analysis of the filtered extract using the reference procedure. In the case of a dispute, only the reference method is used. This document specifies, for the determination of water-soluble chromium (VI) in the filtered extract, the reference methods (colorimetric determination by diphenylcarbazide in acidic conditions) and another method for the determination of total water-soluble chromium (VI) (by inductively coupled plasma optical emission spectroscopy, ICP-OES). The ICP-OES determines the total chromium content independently of the chemical species, i.e. whether it is present as chromium (III) or chromium (VI), for example. Experience has demonstrated that soluble chromium (VI) is predominantly present during the processing phase, such that, in most cases, the determination of total water-soluble chromium (VI) effectively reflects the chromium (VI) content. The water-soluble chromium (VI) content of cement can therefore be assessed conservatively using the method based on ICP-OES described in this document. In the case of a dispute, only the reference methods are used. This document specifies a method that applies to cements. NOTE 1 Annex A provides guidance on the possible application of this document to the determination of the water-soluble chromium (VI) content of cement-containing preparations. NOTE 2 Annexes B and C provide information on other test procedures based on paste extraction and thus depart from the performance of cement in its normal conditions of use. They can be carried out with or without the oxidation process. It is important that users are aware that results using these methods can be significantly different to those obtained by the reference method. In the case of dispute or failure to comply with the regulatory limit, only the reference method is used. NOTE 3 Annex D provides guidance on a method for determination of the excess reducing agent content of cement as used in the factory internal control system of some countries. It is important that manufacturers using such an internal control method ensure themselves of the relevance of results in comparison with testing by the reference method.
This document specifies the method for the determination of the water-soluble chromium (VI) content of cement. A reference method is described consisting of two stages, an extraction procedure and an analysis of the filtered extract. Guidance on other extraction procedures, suitable for screening tests, for factory production control or other purposes, is given but in case of dispute or failure to comply with a regulatory limit only the reference method is used. The reference method has alternatives whereby the filtered extract can be subjected to an oxidation step or not. The criteria by which the appropriate procedure is selected are set down. Other instrumental procedures can be used for the analysis of the filtered extract provided they are calibrated against the analysis of the filtered extract using the reference procedure. In the case of a dispute, only the reference method is used. This document specifies, for the determination of water-soluble chromium (VI) in the filtered extract, the reference methods (colorimetric determination by diphenylcarbazide in acidic conditions) and another method for the determination of total water-soluble chromium (VI) (by inductively coupled plasma optical emission spectroscopy, ICP-OES). The ICP-OES determines the total chromium content independently of the chemical species, i.e. whether it is present as chromium (III) or chromium (VI), for example. Experience has demonstrated that soluble chromium (VI) is predominantly present during the processing phase, such that, in most cases, the determination of total water-soluble chromium (VI) effectively reflects the chromium (VI) content. The water-soluble chromium (VI) content of cement can therefore be assessed conservatively using the method based on ICP-OES described in this document. In the case of a dispute, only the reference methods are used. This document specifies a method that applies to cements. NOTE 1 Annex A provides guidance on the possible application of this document to the determination of the water-soluble chromium (VI) content of cement-containing preparations. NOTE 2 Annexes B and C provide information on other test procedures based on paste extraction and thus depart from the performance of cement in its normal conditions of use. They can be carried out with or without the oxidation process. It is important that users are aware that results using these methods can be significantly different to those obtained by the reference method. In the case of dispute or failure to comply with the regulatory limit, only the reference method is used. NOTE 3 Annex D provides guidance on a method for determination of the excess reducing agent content of cement as used in the factory internal control system of some countries. It is important that manufacturers using such an internal control method ensure themselves of the relevance of results in comparison with testing by the reference method.
kSIST FprEN 196-10:2026 is classified under the following ICS (International Classification for Standards) categories: 91.100.10 - Cement. Gypsum. Lime. Mortar. The ICS classification helps identify the subject area and facilitates finding related standards.
kSIST FprEN 196-10:2026 has the following relationships with other standards: It is inter standard links to SIST EN 196-10:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
kSIST FprEN 196-10:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 analyte
- 3.2 calibration solution
- 3.3 stock solution
- 3.4 blank test solution
- 3.5 calibration check solution
- 3.6 calibration blank solution
- 4 General requirements for testing
- 4.1 Number of tests
- 4.2 Repeatability and reproducibility
- 4.3 Expression of masses, volumes, factors and results
- 4.4 Blank determinations
- 5 Reagents
- 5.5 Indicator solution. Dissolve 0,125 g of s-diphenylcarbazide (C H NHNH)CO, (1,5-
- 5.6 Standard chromate solution
- 6 Apparatus
- 6.1 Balance(s)
- 7 Preparation of a test sample of cement
- 8 Extraction procedure
- 8.1 Principle
- 8.2 Preparation of mortar
- 8.3 Filtration
- 9 Determination of chromium (VI) by colorimetric determination by
- 9.1 General
- 9.2 Measurement of absorbance without oxidation
- 9.3 Measurement of absorbance with oxidation
- 10 Calculation and expression of results
- 10.1 Calculation
- 10.2 Expression of results
- 11 Reporting of results
- 12 Repeatability and reproducibility
- 13 Determination of total water-soluble chromium by inductively coupled plasma
- 13.1 Principle
- 13.2 Reagents and materials
- 13.3 Apparatus
- 13.4 Extraction procedure
- 13.5 Filtration
- 13.6 Sample preparation
- 13.7 Calibration
- 14 Measuring
- 15 Test procedure
- 16 Expression of results
- 17 Reporting of results
- 18 Repeatability and reproducibility
- Annex A
- Annex B
- Annex C
- Annex D
- Annex E
- Bibliography
Introduction
This document specifies the reference and an alternative method for the determination of water-soluble chromium (VI) content of cement that consists of two stages, an extraction procedure and an analysis of the filtered extract.
This document test method has adopted the principle that extraction is carried out under conditions approximating as closely as possible to those during the commercial use of cement. Consequently, extraction is by standard mortar and subsequent filtration. Other extraction procedures based on paste extraction have traditionally been used and are included in Annexes C and D for use as screening tests, in factory production control or laboratories not having access to equipment specified in EN 196-1 to produce mortar. The use of paste extraction is outside the normal conditions of use of cement. This document test method has adopted the principle of analysis by spectrophotometry as reference method for the determination of chromium (VI) in the filtrate. The procedure is set down generally permit the analysis to be carried out without the need for an oxidation step. On rare occasions, some cements can contain reducing species that interfere, in acid solution, with the analysis of Cr(VI) that cannot be determined correctly with the method without oxidation; in this case the analysis require an oxidation step. Another method using inductively coupled plasma optical emission spectroscopy (ICP-OES) is described for the determination of water-soluble chromium in the filtrate. This procedure permits the determination of total water-soluble chromium in the filtrate without the need for an oxidation step. NOTE ICP-OES, if no chromatography is used, is not selective on Cr(VI) and also considers Cr(III) if water soluble amounts would be present.
Inter-laboratory testing has demonstrated that it is necessary to include an ‘initial assessment test in order to observe the effects on the analysis. By comparing the results obtained from the method with and without the oxidation step, it can be determined whether, for that cement, the reference method should include the oxidation step.
Other instrumental procedures can be used for the analysis of the filtered extract provided they are calibrated against the analysis of the filtered extract using the reference procedure. This document’s test method has drawn heavily on the Danish Standard DS 1020:1984 and the extraction procedure developed by the French cement industry association ATILH. Careful consideration has been given to the details of the German TRGS 613 method developed by Germany’s Hazardous Materials Committee in support of Industrial Regulations for Hazardous Materials. Notice was also taken of the British Cement Association ‘inherent colour’ method; the draft method produced by CEN/TC 193/WG1, reference N680, for cement-based adhesives; EN ISO 21420 for protective gloves; and to the method, reference ID-215, developed by the Occupational Safety and Health Administration, Salt Lake, USA. The USA Portland Cement Association, Research and Development report Serial No. 2554 “Review and evaluation of analytical methods for the determination of hexavalent chromium in hydraulic cements and clinker” by Waldemar A. Klemm was found to be most helpful in resolving technical issues. CEN/TR 14589 confirmed that chromium species and solubilities are sensitive to pH and redox conditions and care has been taken to address these in this document by controlling sample exposure to air, by adding the indicator to the alkaline filtered extract and by precisely specifying the pH for the analytical procedure. This document test method was developed in order to provide a reference test method for use in the evaluation of compliance of cement with the requirements in the Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration, Evaluation, Authorization and Restriction of Chemicals (REACH), establishing a European Chemicals Agency, amending Directive 1999/45/EC and repealing Council Regulation (EEC) No 793/93 and Commission Regulation (EC) No 1488/94 as well as Council Directive 76/769/EEC and Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 2000/21/EC which contain prohibitions, among other requirements, against placing on the market or using
oSIST prEN 196-10:2025 prEN 196-10:2025 (E) cement, and cement-containing mixtures, if they contain, when hydrated, more than 2 mg/kg (0,00 02 %) soluble chromium VI of the total dry weight of the cement.
EN 197-10 specifies the scheme for the assessment of conformity with the regulatory limit for water-soluble hexavalent chromium.
Under preparation. Stage at the time of preparation: prEN 197-10:2025
oSIST prEN 196-10:2025 prEN 196-10:2025 (E)
1 Scope
This document specifies the method for the determination of the water-soluble chromium (VI) content of cement.
A reference method is described consisting of two stages, an extraction procedure and an analysis of the filtered extract. Guidance on other extraction procedures, suitable for screening tests, for factory production control or other purposes, is given but in case of dispute or failure to comply with a regulatory limit only the reference method is used. The reference method has alternatives whereby the filtered extract can be subjected to an oxidation step or not. The criteria by which the appropriate procedure is selected are set down. Other instrumental procedures can be used for the analysis of the filtered extract provided they are calibrated against the analysis of the filtered extract using the reference procedure. In the case of a dispute, only the reference method is used.
This document specifies, for the determination of water-soluble chromium (VI) in the filtered extract, the reference methods (colorimetric determination by diphenylcarbazide in acidic conditions) and another method for the determination of total water-soluble chromium (by inductively coupled plasma optical emission spectroscopy, ICP-OES).
The ICP-OES determines the total chromium content independently of the chemical species, i.e. whether it is present as chromium (III) or chromium (VI), for example. Experience has demonstrated that soluble chromium (VI) is predominantly present during the processing phase, such that, in most cases, the determination of total water-soluble chromium effectively reflects the chromium (VI) content. The water-soluble chromium (VI) content of cement can therefore be assessed conservatively using the method based on ICP-OES described in this document.
In the case of a dispute, only the reference methods are used. This document specifies a method that applies to cements.
NOTE 1 Annex A provides guidance on the possible application of this document to the determination of the watersoluble chromium (VI) content of cement-containing preparations. NOTE 2 Annexes B and C provide information on other test procedures based on paste extraction and thus depart from the performance of cement in its normal conditions of use. They can be carried out with or without the oxidation process. It is important that users are aware that results using these methods might be significantly different to those obtained by the reference method. In the case of dispute or failure to comply with the regulatory limit, only the reference method is used.
NOTE 3 Annex D provides guidance on a method for determination of the excess reducing agent content of cement as used in the factory internal control system of some countries. It is important that manufacturers using such an internal control method ensure themselves of the relevance of results in comparison with testing by the reference method.
2 Normative references
The following documents are referred to in the text in such a way that some or all their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 196-1, Methods of testing cement — Part 1: Determination of strength EN 196-7, Methods of testing cement — Part 7: Methods of taking and preparing samples of cement
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
oSIST prEN 196-10:2025 prEN 196-10:2025 (E) ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https://www.iso.org/obp/
- IEC Electropedia: available at https://www.electropedia.org/
3.1 analyte
element to be determined
3.2 calibration solution
solution used (at least two) to calibrate the instrument, prepared from stock solutions by adding acids, buffer, reference element and salts as needed
3.3 stock solution
solution with accurately known analyte concentration(s), prepared from pure chemicals Note 1 to entry: Certified commercial standard solutions can be used. Note 2 to entry: Stock solutions are reference materials within the meaning of ISO Guide 30.
3.4 blank test solution
solution prepared in the same way as the test sample solution but omitting the test portion
3.5 calibration check solution
solution of an accurately known analyte concentration, prepared from pure chemicals; the solution should be independent from the calibration stock solution Note 1 to entry: See Annex E.
3.6 calibration blank solution
solution prepared like the calibration standards but omitting the analyte
4 General requirements for testing
4.1 Number of tests
Determination of water-soluble chromium (VI) content of cement, where the determination is not part of a series subject to statistical control, shall be carried out in duplicate. Where the determination is one of a series subject to statistical control, a single test shall be the minimum required.
In the case of a dispute, the number of tests shall be two (see also 4.3).
4.2 Repeatability and reproducibility
Repeatability - precision under repeatability conditions where independent test results are obtained with the same method on identical test items (material) in the same laboratory by the same operator using the same equipment within short intervals of time.
oSIST prEN 196-10:2025 prEN 196-10:2025 (E) Reproducibility - precision under reproducibility conditions where test results are obtained with the same method on identical test items (material) in different laboratories with different operators using different equipment.
Repeatability and reproducibility in this document are expressed as repeatability standard deviation and reproducibility standard deviation in percent by mass.
4.3 Expression of masses, volumes, factors and results
Express masses in the extraction stage in grams to the nearest 0,1 g. Express masses in the analytical stage in grams to the nearest 0,0001 g and volumes from burettes in millilitres to the nearest 0,05 ml unless otherwise specified.
Express the calculated results, where a single test result has been obtained, as a percentage of the cement as received.
Express the calculated results, where two test results have been obtained, as the mean of the results, as a percentage of the cement as received.
If the two test results differ by more than twice the standard deviation of repeatability, repeat the test and take the mean of the two closest test results.
Express the reported water-soluble chromium (VI) content as a percentage of the cement as received, to four decimal places.
Where the results of determinations with and without oxidation are to be compared, results shall be considered equivalent if they do not differ by more than twice the standard deviation of repeatability. The results of all individual tests shall be recorded.
4.4 Blank determinations
Carry out a blank determination without a sample following the same procedure and using the same amounts of reagents. Correct the results obtained for the analytical determination accordingly.
5 Reagents
Use only reagents of analytical quality. References to water mean distilled or deionised water with electrical conductivity ≤ 0,5 mS/m.
Unless otherwise stated percent means percent by mass.
Unless otherwise stated the densities of concentrated liquid reagents (ρ) used in this document are on the basis
of g/cm at 20 °C.
5.1 Concentrated hydrochloric acid (HCl), ρ = 1,18 to 1,19.
5.2 Dilute hydrochloric acid, 1,0 mol/l.
5.3 Dilute hydrochloric acid, 0,04 mol/l.
5.4 Acetone, (CH .CO.CH ), ρ = 0,79.
3 3
5.5 Indicator solution. Dissolve 0,125 g of s-diphenylcarbazide (C H NHNH)CO, (1,5-
6 5 2 diphenylcarbohydrazide) in 25 ml of acetone (5.4) in a 50 ml volumetric flask. Make up to the mark with acetone. The indicator solution will keep for one week, if kept refrigerated.
oSIST prEN 196-10:2025 prEN 196-10:2025 (E)
5.6 Standard chromate solution
5.6.1 Stock solution: Dissolve 0,141 4 g dried potassium dichromate (K Cr O ), dried to constant mass at 2 2 7 (140 ± 5) °C, in water in a 1 000 ml volumetric flask and make up to the mark with water. The stock solution will last for one month.
This solution contains 50 mg Cr(VI) in a litre.
NOTE Ready-to-use stock solution is commercially available.
5.6.2 Standard solution: Transfer 50,0 ml stock solution (5.6.1) to a 500 ml volumetric flask and make up to the mark with water. The standard solution shall be used no later than one month after preparation of the stock solution.
This solution contains 5 mg Cr(VI) in a litre.
5.7 Sand, in accordance with EN 196-1.
5.8 Sodium peroxodisulfate (sodium persulfate), Na S O .
2 2 8 5.9 Orthophosphoric acid, H PO , (85 %).
3 4 5.10 Concentrated nitric acid, HNO (65 %; ~ 1,4 kg/l).
6 Apparatus
6.1 Balance(s)
- analytical balance, capable of weighing to an accuracy of ± 0,000 5 g;
- laboratory balance, capable of weighing to an accuracy of ± 1 g. 6.2 Mixer, two speed in accordance with EN 196-1.
6.3 Spectrophotometer, for measuring the absorbance of a solution at 540 nm, or filter photometer equipped with a filter giving maximum transmission at approximately 540 nm. 6.4 Cells, with a light path of 10 mm.
6.5 Volumetric glassware, 50 ml, 500 ml and 1 000 ml volumetric flasks; 1,0 ml; 2,0 ml; 5,0 ml; 10,0 ml; 15,0 ml and 50,0 ml pipettes.
6.6 pH meter, capable of measuring pH to an accuracy of ± 0,05. 6.7 Filter media, of pore size 7 μm or less, composed of fibre, free from organic binders, or equivalent fritted glass filter. Some filter media can become contaminated during manufacture with substances that can reduce chromium (VI). A blank test should be carried out to ensure the suitability of the filter medium selected. 6.8 Filtration equipment, Filtration equipment consisting of a Buchner funnel, (e.g. diameter 205 mm, fitted onto a 2-l filter flask), partially full of sand, inside which is a low form beaker to collect the filtrate, placed on top of the bed of sand. The apparatus is connected to a vacuum pump (see Figure 1).
oSIST prEN 196-10:2025 prEN 196-10:2025 (E)
Key 1 mortar 2 filter funnel 3 to vacuum 4 low form beaker 5 filter flask 6 sand Figure 1 — Typical arrangement of filtration equipment 6.9 Laboratory oven, capable of maintaining a temperature of (140 ± 5) °C. 6.10 Heating plate, capable of maintaining a temperature of (280 ± 10) °C. 6.11 Timer, capable of measuring to an accuracy of ± 1 s.
7 Preparation of a test sample of cement
Immediately before chemical analysis, treat the laboratory sample, taken in accordance with EN 196-7, as follows to obtain a homogeneous test sample.
Take approximately 1 000 g of the laboratory sample by means of a sample divider or by quartering. Transfer this test sample to a clean dry container with an airtight closure and shake vigorously to mix it thoroughly.
Carry out all operations as quickly as possible and immediately seal in an airtight. container to ensure that the test sample is exposed to ambient air only for the minimum time.
oSIST prEN 196-10:2025 prEN 196-10:2025 (E)
8 Extraction procedure
8.1 Principle
Cement is made into a mortar using sand in accordance with EN 196-1 and water. The mortar is mixed for a specified time and then filtered. An aliquot of filtrate is treated with s-diphenylcarbazide and acidified within a narrow range of pH. Chromium (VI) in acid solution forms a red-violet complex the absorption of which is measured spectrophotometrically at 540 nm. The water-soluble chromium (VI) content is determined from a calibration curve.
8.2 Preparation of mortar
8.2.1 Composition of mortar
The proportions by mass shall be one part of cement (see Clause 6), three parts of sand (5.7), and one-half part of water (i.e. water/cement ratio 0,50).
NOTE The water to be used is analytical grade.
Each batch shall consist of (450 ± 2) g of cement, (M), (1 350 ± 5) g of sand and (225 ± 1) g of water, (V ).
Where cements to be tested are rapid setting, a water/cement ratio of 0,50 might not yield sufficient filtrate for analysis. In these cases, it is permissible to increase the water content, and hence the water/cement ratio, until sufficient filtrate (see 8.3) is obtained. This deviation should be reported.
8.2.2 Mixing of mortar
Weigh the cement and water by means of the laboratory balance (6.1). When water is added by volume it shall be dispensed with an accuracy of ± 1 ml. Mix each batch of mortar mechanically using the mixer (6.2). The timing of the various mixing stages refers to the times at which mixer power is switched on/off and shall be maintained within ± 2 s.
The mixing procedure shall be as follows:
a) place the water and the cement into the bowl, taking care to avoid loss of water or cement; b) immediately the water and cement are brought into contact start the mixer at the low speed (see EN 196-1, table of mixer speeds) whilst starting the timing of the mixing stages. After 30 s of mixing, add the sand steadily during the next 30 s. Switch the mixer to the high speed (see EN 196-1, table of mixer speeds) and continue the mixing for an additional 30 s; c) stop the mixer for 90 s. During the first 30 s, remove by means of a rubber or plastics scraper the mortar adhering to the wall and bottom part of the bowl and place in the middle of the bowl; d) continue the mixing at the high speed for 60 s.
Normally, these mixing operations are carried out automatically. Manual control of these operations and timings may be used.
8.3 Filtration
Ensure that the filtration equipment (6.8) (filter flask, filter crucible or Buchner funnel and filter medium and low form beaker) is dry before each use. Fit the filter crucible or Buchner funnel and filter medium (5.7). Do not pre-wet the filter medium. Apply the vacuum and place the mortar into the filtration equipment. Filter for a maximum of 10 min to obtain a volume of 10 ml to 15 ml of filtrate. If 10 ml is not obtained in this time, continue filtering to obtain sufficient quantity to carry out the determination(s). Report this deviation.
oSIST prEN 196-10:2025 prEN 196-10:2025 (E) The filtrate may be stored for up to 8 h before determination of the chromium (VI) content but if the storage period exceeds 30 min it shall be kept in a sealed air-tight container to prevent evaporation. Where a filtrate has a turbidity that cannot be removed by simple filtration, it may be filtered by centrifuge, filter press or filtered over a fine-pore membrane filter. Report the alternative filtration method used. No verification against the reference method is required in these cases. Where the filtrate still has turbidity, the blank used with these samples should be a filtrate from the respective sample but without the addition of indicator solution.
...