ISO 5832-3:2016
(Main)Implants for surgery — Metallic materials — Part 3: Wrought titanium 6-aluminium 4-vanadium alloy
Implants for surgery — Metallic materials — Part 3: Wrought titanium 6-aluminium 4-vanadium alloy
ISO 5832-3:2016 specifies the characteristics of, and corresponding test methods for, the wrought titanium alloy known as titanium 6-aluminium 4-vanadium alloy (Ti 6-AI4-V alloy) for use in the manufacture of surgical implants. NOTE The mechanical properties of a sample obtained from a finished product made of this alloy may not necessarily comply with the specifications given in this part of ISO 5832.
Implants chirurgicaux — Produits à base de métaux — Partie 3: Alliage corroyé à base de titane, d'aluminium-6 et de vanadium-4
ISO 5832-3:2016 spécifie les caractéristiques de l'alliage corroyé à base de de titane, connu sous le nom d'alliage de titane, d'aluminium-6 et de vanadium-4 (alliage Ti 6-AI4-V) utilisable dans la fabrication d'implants chirurgicaux, et les méthodes d'essai correspondantes. NOTE Les propriétés mécaniques d'un échantillon prélevé sur un produit fini fabriqué avec cet alliage peuvent ne pas nécessairement être conformes aux spécifications données dans la présente partie de l'ISO 5832.
General Information
- Status
- Withdrawn
- Publication Date
- 05-Oct-2016
- Withdrawal Date
- 05-Oct-2016
- Technical Committee
- ISO/TC 150/SC 1 - Materials
- Drafting Committee
- ISO/TC 150/SC 1/WG 4 - Metals
- Current Stage
- 9599 - Withdrawal of International Standard
- Start Date
- 18-Nov-2021
- Completion Date
- 14-Feb-2026
Relations
- Effective Date
- 12-Feb-2026
- Effective Date
- 23-Apr-2020
- Effective Date
- 24-May-2014
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

TÜV Rheinland
TÜV Rheinland is a leading international provider of technical services.

TÜV SÜD
TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.
Sponsored listings
Frequently Asked Questions
ISO 5832-3:2016 is a standard published by the International Organization for Standardization (ISO). Its full title is "Implants for surgery — Metallic materials — Part 3: Wrought titanium 6-aluminium 4-vanadium alloy". This standard covers: ISO 5832-3:2016 specifies the characteristics of, and corresponding test methods for, the wrought titanium alloy known as titanium 6-aluminium 4-vanadium alloy (Ti 6-AI4-V alloy) for use in the manufacture of surgical implants. NOTE The mechanical properties of a sample obtained from a finished product made of this alloy may not necessarily comply with the specifications given in this part of ISO 5832.
ISO 5832-3:2016 specifies the characteristics of, and corresponding test methods for, the wrought titanium alloy known as titanium 6-aluminium 4-vanadium alloy (Ti 6-AI4-V alloy) for use in the manufacture of surgical implants. NOTE The mechanical properties of a sample obtained from a finished product made of this alloy may not necessarily comply with the specifications given in this part of ISO 5832.
ISO 5832-3:2016 is classified under the following ICS (International Classification for Standards) categories: 11.040.40 - Implants for surgery, prosthetics and orthotics. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 5832-3:2016 has the following relationships with other standards: It is inter standard links to EN ISO 5832-3:2016, ISO 5832-3:2021, ISO 5832-3:1996. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO 5832-3:2016 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 5832-3
Fourth edition
2016-10-15
Implants for surgery — Metallic
materials —
Part 3:
Wrought titanium 6-aluminium
4-vanadium alloy
Implants chirurgicaux — Produits à base de métaux —
Partie 3: Alliage corroyé à base de titane, d’aluminium-6 et de
vanadium-4
Reference number
©
ISO 2016
© ISO 2016, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – All rights reserved
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Chemical composition . 1
5 Microstructure . 2
6 Mechanical properties . 2
6.1 Tensile . 2
6.2 Bending . 3
7 Test methods . 3
Annex A (normative) Catalogues of metallographic micrographs of typical alpha+beta
titanium microstructures . 4
Annex B (informative) Mechanical Properties Harmonization between ISO and ASTM
wrought titanium 6-aluminium 4-vanadium Implant Material Standards .5
Bibliography . 7
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity assessment,
as well as information about ISO’s adherence to the World Trade Organization (WTO) principles in the
Technical Barriers to Trade (TBT) see the following URL: www.iso.org/iso/foreword.html.
The committee responsible for this document is ISO/TC 150, Implants for surgery, Subcommittee SC 1,
Materials.
This fourth edition cancels and replaces the third edition (ISO 5832-3:1996), which has been technically
revised.
ISO 5832 consists of the following parts, under the general title Implants for surgery — Metallic materials:
— Part 1: Wrought stainless steel
— Part 2: Unalloyed titanium
— Part 3: Wrought titanium 6-aluminium 4-vanadium alloy
— Part 4: Cobalt-chromium-molybdenum casting alloy
— Part 5: Wrought cobalt-chromium-tungsten-nickel alloy
— Part 6: Wrought cobalt-nickel-chromium-molybdenum alloy
— Part 7: Forgeable and cold-formed cobalt-chromium-nickel-molybdenum-iron alloy
— Part 8: Wrought cobalt-nickel-chromium-molybdenum-tungsten-iron alloy
— Part 9: Wrought high nitrogen stainless steel
— Part 11: Wrought titanium 6-aluminium 7-niobium alloy
— Part 12: Wrought cobalt-chromium-molybdenum alloy
— Part 14: Wrought titanium 15-molybdenum 5-zirconium 3-aluminium alloy
iv © ISO 2016 – All rights reserved
Introduction
No known surgical implant material has ever been shown to cause absolutely no adverse reactions in
the human body. However, long-term clinical experience of the use of the material referred to in this
part of ISO 5832 has shown that an acceptable level of biological response can be expected when the
material is used in appropriate applications.
INTERNATIONAL STANDARD ISO 5832-3:2016(E)
Implants for surgery — Metallic materials —
Part 3:
Wrought titanium 6-aluminium 4-vanadium alloy
1 Scope
This part of ISO 5832 specifies the characteristics of, and corresponding test methods for, the wrought
titanium alloy known as titanium 6-aluminium 4-vanadium alloy (Ti 6-AI4-V alloy) for use in the
manufacture of surgical implants.
NOTE The mechanical properties of a sample obtained from a finished product made of this alloy may not
necessarily comply with the specifications given in this part of ISO 5832.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
1)
ISO 6892-1 , Metallic materials — Tensile testing — Part 1: Method of test at room temperature
ISO 7438, Metallic materials — Bend test
ISO 20160, Implants for surgery — Metallic materials — Classification of microstructures for alpha+beta
titanium alloy bars
EN 3114-003, Aerospace series — Test method — Microstructure of (α+β) titanium alloy wrought
products — Part 003: Microstructure of plate
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 6892-1 and the following apply.
3.1
original gauge length
L
o
length between gauge length marks on the test piece measured at room temperature before the test
[SOURCE: ISO 6892-1:—, 3.1.1]
4 Chemical composition
Th
...
NORME ISO
INTERNATIONALE 5832-3
Quatrième édition
2016-10-15
Version corrigée
2017-04
Implants chirurgicaux — Produits à
base de métaux —
Partie 3:
Alliage corroyé à base de titane,
d’aluminium-6 et de vanadium-4
Implants for surgery — Metallic materials —
Part 3: Wrought titanium 6-aluminium 4-vanadium alloy
Numéro de référence
©
ISO 2016
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2016, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – Tous droits réservés
Sommaire Page
Avant-propos .iv
Introduction .vi
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Composition chimique . 2
5 Microstructure . 2
6 Propriétés mécaniques . 2
6.1 Résistance à la traction . 2
6.2 Résistance au pliage . 3
7 Méthodes d’essai . 3
Annexe A (normative) Catalogues de micrographies métallographiques de microstructures
en alliage de titane alpha+bêta classiques . 5
Annexe B (informative) Harmonisation des propriétés mécaniques entre les normes ISO et
ASTM sur les matériaux corroyés à base de titane, d’aluminium-6 et de vanadium-4
pour les implants chirurgicaux . 6
Bibliographie . 8
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www.
iso.org/directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la signification des termes et expressions spécifiques de l’ISO liés à
l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion de l’ISO aux principes
de l’OMC concernant les obstacles techniques au commerce (OTC), voir le lien suivant: Avant-propos —
Informations supplémentaires.
Le comité chargé de l’élaboration du présent document est l’ISO/TC 150, Implants chirurgicaux, sous-
comité SC 1, Matériaux.
Cette quatrième édition annule et remplace la troisième édition (ISO 5832-3:1996), qui a fait l’objet
d’une révision technique.
L’ISO 5832 comprend les parties suivantes, présentées sous le titre général Implants chirurgicaux —
Produits à base de métaux:
— Partie 1: Acier inoxydable corroyé
— Partie 2: Titane non allié
— Partie 3: Alliage corroyé à base de titane, d’aluminium 6 et de vanadium 4
— Partie 4: Alliage à couler à base de cobalt, de chrome et de molybdène
— Partie 5: Alliage corroyé à base de cobalt, de chrome, de tungstène et de nickel
— Partie 6: Alliage corroyé à base de cobalt, de nickel, de chrome et de molybdène
— Partie 7: Alliage à forger mis en forme à froid à base de cobalt, de chrome, de nickel, de molybdène et de fer
— Partie 8: Alliage corroyé à base de cobalt, de nickel, de chrome, de molybdène, de tungstène et de fer
— Partie 9: Acier inoxydable corroyé à haute teneur en azote
— Partie 11: Alliage à forger à base de titane, d’aluminium 6 et de niobium 7
— Partie 12: Alliage corroyé à base de cobalt, de chrome et de molybdène
iv © ISO 2016 – Tous droits réservés
— Partie 14: Alliage corroyé à base de titane, de molybdène-15, de zirconium-5 et d’aluminium-3
La présente version corrigée de l’ISO 5832-3:2016 inclut la correction suivante:
— Dans le Tableau 1, la valeur de la composition chimique de l’aluminium a été remplacée par «5,5
à 6,75».
Introduction
Il n’existe à ce jour aucun produit connu, utilisé dans la fabrication des implants chirurgicaux, qui
n’exerce absolument aucun effet défavorable sur le corps humain. Cependant, une expérience clinique
à long terme de l’utilisation du produit auquel la présente partie de l’ISO 5832 fait référence a montré
qu’un niveau acceptable de réponse biologique peut être obtenu lorsque le produit est utilisé dans le
cadre d’applications appropriées.
vi © ISO 2016 – Tous droits réservés
NORME INTERNATIONALE ISO 5832-3:2016(F)
Implants chirurgicaux — Produits à base de métaux —
Partie 3:
Alliage corroyé à base de titane, d’aluminium-6 et de
vanadium-4
1 Domaine d’application
La présente partie de l’ISO 5832 spécifie les caractéristiques de l’alliage corroyé à base de de titane,
connu sous le nom d’alliage de titane, d’aluminium-6 et de vanadium-4 (alliage Ti 6-AI4-V) utilisable
dans la fabrication d’implants chirurgicaux, et les méthodes d’essai correspondantes.
NOTE Les propriétés mécaniques d’un échantillon prélevé sur un produit fini fabriqué avec cet alliage
peuvent ne pas nécessairement être conformes aux spécifications données dans la présente partie de l’ISO 5832.
2 Références normatives
Les documents ci-après, dans leur intégralité ou non, sont des références normatives indispensables à
l’application du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les
références non datées, la dernière édition du document de référence s’applique (y compris les éventuels
amendements).
1)
ISO 6892-1 , Matériaux métalliques — Essai de traction — Partie 1: Méthode d’essai à température
ambiante
ISO 7438, Matériaux métalliques — Essai de pliage
ISO 20160, Implants chirurgicaux — Matériaux métalliques — Classification des microstructures des
barres en alliages de titane alpha+bêta
EN 3114-003, Série aérospatiale — Méthode d’essai — Microstructure des produits corroyés en alliage de
titane (α+β) — Partie 003: Microstructure des plaques
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions donnés dans l’ISO 6892-1 ainsi que les
suivants s’appliquent.
3.1
longueur entre repères initiale
L
o
longueur entre les repères sur l’éprouvette, mesurée à température ambiante avant l’essai
[SOURCE: ISO 6892-1:—, 3.1.1]
1) En cours de publication (révision de l’ISO 68
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...