Abstract

The preferred method is to extract fluid samples from a main flowline in such a manner that the particulate contaminant in the sample is representative of the fluid flowing at the point of sampling. An alternative method is to extract a sample from the reservoir, but this method should only be used if a suitable sampler is not fitted.

Status
Not Published
Current Stage
5020 - Proof sent to secretariat or FDIS ballot initiated: 8 weeks - 50 Approval
Start Date
17-Nov-2026

Buy Documents

Draft

ISO/PRF 4021 - Hydraulic fluid power — Particulate contamination analysis — Extraction of fluid samples from lines of an operating system

Release Date:17-Nov-2026
English language (14 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/PRF 4021 - Hydraulic fluid power — Particulate contamination analysis — Extraction of fluid samples from lines of an operating system

Release Date:17-Nov-2026
English language (14 pages)
sale 15% off
sale 15% off

ISO/PRF 4021 is an ISO document for hydraulic fluid power systems that specifies how to extract fluid samples from lines of an operating system for particulate contamination analysis. It covers both offline and online sampling and is intended for operators, maintenance staff, and laboratories that need representative samples from operating hydraulic equipment. The document gives a preferred method for sampling from a main flowline and an alternative reservoir method when a suitable sampler cannot be fitted.

What does ISO/PRF 4021 specify?

ISO/PRF 4021 specifies procedures for extracting fluid samples from a hydraulic fluid power system while it is operating. Its central aim is to obtain a sample whose particulate contamination represents the fluid at the sampling point, because the sample quality directly affects contamination measurements and any corrective action that follows.

The document is organized into scope, normative references, terms and definitions, sampling point selection, supplies and materials, sampling frequency, sampling principles, sampling procedures, labelling, and an identification statement. Annex A is informative and supports the sampling method by giving a Reynolds number calculation for assessing flow conditions.

Clause 4 focuses on where to sample, Clause 5 on bottles and solvent, Clause 6 on when to sample, Clause 7 on the principles for line and reservoir sampling, and Clause 8 on the detailed procedures for offline and online analysis. That structure helps users move from planning to execution without mixing sampling choices with laboratory measurement requirements.

What are the key requirements of ISO/PRF 4021?

ISO/PRF 4021 places most emphasis on taking samples from a main fluid line under turbulent flow. The document treats this as the preferred approach because a turbulent section is more likely to carry particles evenly through the sample, which improves representativeness.

Sampling point and flow conditions

Clause 4 requires sampling points to be chosen for the purpose of the sample, to collect representative fluid, and to be located where the task is practical to perform. Clause 4.2 lists typical locations such as upstream or downstream of return line and pressure line filters, case drains, and the reservoir. In practice, this means the chosen point should match the diagnostic question - for example, filter performance, component wear, or overall system cleanliness.

For line sampling, Clause 7.1 says the extraction point should be in a turbulent flow zone, with the sampler axis positioned to reduce boundary-layer effects. If turbulence cannot be assured, the document allows the use of a turbulence-inducing means. This matters because a poor sampling location can bias the particle count and lead to the wrong maintenance decision.

Sampler design and installation

Clause 7.1 also describes the expected characteristics of a line sampler: it must suit the fluid and system pressure, allow on/off control, and be designed to reduce pressure to atmospheric conditions without changing contamination distribution. The sampler should minimize dead zones, avoid generating particles itself, and clean itself by flushing. For users, this means the sampling hardware is part of the measurement quality, not just a convenience item.

The sampler port should be permanently attached, protected by dust caps, and placed where it is easy to reach and away from environmental contamination. Clause 7.1.6 requires a flow rate suitable for sampling, and Clause 7.1.7 recommends a bypass circuit for online analysis when the measuring instrument and pipeline arrangement would otherwise trap particles or restrict flow. That is important because the sample line itself can distort the result if particles settle in long or low-flow tubing.

Reservoir sampling as a fallback

Clause 7.2 allows reservoir sampling only when a line sampler cannot be fitted directly. The document warns that reservoir samples are less representative than live dynamic sampling, so the user should avoid static zones and create a homogeneous mixture by operating the system long enough before sampling. When reservoir sampling is necessary, the user must also minimize contamination introduced at the opening or through the sampling device.

The document describes two reservoir options: a vacuum sampler and a shut-off valve sampler. The vacuum method uses two bottles, one for flushing and one for the actual sample, while the shut-off valve method allows direct extraction from a reservoir-mounted valve. This gives users a practical fallback without changing the basic contamination-control intent.

Sampling supplies, solvents, and bottle cleanliness

Clause 5 requires sample bottles to be chemically compatible with the fluid and suitable for the temperature range. They should be transparent, smooth inside, easy to clean, and sealed to prevent secondary contamination. The document also ties bottle cleanliness to ISO 3722, which means bottle preparation is treated as part of the sampling method, not an optional laboratory preference.

The solvent must be compatible with the sample and clean enough not to add contamination. The document also warns that the recommended solvents are hazardous, so the user must apply safety data sheets and local safety requirements. In practice, this means cleaning steps must be controlled rather than improvised in the field.

Sampling timing and operating conditions

Clause 6 says sampling should be carried out regularly, with frequency based on system criticality, operating conditions, fluid age, system age, failure behaviour, and current condition reports. It also recommends immediate sampling after flushing, delivery, abnormal operation, component replacement, or failure. This helps users sample at moments when contamination information is most useful for diagnosis or verification.

Offline and online procedures

Clause 8 separates offline and online sampling procedures. Both require cleaning the sampler area, flushing the sampling path before collecting the actual sample, and restoring the system to its original state afterwards. For online analysis, the measuring instrument must be calibrated according to ISO 11171 or ISO 11943 and used in line with ISO 21018-1. That makes the sampling method compatible with both bottle-based laboratory analysis and direct instrument counting.

What terms does ISO/PRF 4021 define?

  • Sampler - a device for taking a representative sample from a larger source.
  • Turbulent flow - fluid flow in which particle motion changes rapidly in speed and direction, supporting better mixing of contamination.
  • Reynolds number (Re) - the dimensionless indicator used in Annex A to judge whether flow is turbulent.
  • Required cleanliness level (RCL) - the target particle concentration level that operators and manufacturers use to decide when corrective action is needed.
  • Offline analysis - contamination analysis performed after the sample has been collected in a bottle or container.
  • Online analysis - contamination analysis performed directly through a measuring instrument while fluid is being sampled.
  • Sampling point - the selected location in the hydraulic system from which the sample is taken.

Who uses ISO/PRF 4021?

ISO/PRF 4021 is used by operators and manufacturers of hydraulic equipment, contamination-control personnel, maintenance teams, and test laboratories. It is relevant in commissioning, routine monitoring, failure investigation, filter assessment, and verification of hydraulic fluid cleanliness. Quality managers and buyers may also use it when specifying how contamination samples must be taken and documented.

What changed in ISO/PRF 4021 from the previous edition?

ISO/PRF 4021 is the third edition and cancels and replaces ISO 4021:1992. The foreword states that the document has been technically revised.

The stated changes are:

  • deletion of several earlier terms and definitions
  • addition of sampling point guidance
  • addition of sample bottle requirements
  • addition of sampling frequency guidance
  • addition of a recommended bypass circuit for line sampling
  • revision of the reservoir sampling principle
  • addition of reservoir sampling through a shut-off valve
  • addition of an online analysis sampling procedure
  • modification of the Reynolds number calculation formula

Which standards are used with ISO/PRF 4021?

  • ISO 3722 - gives the cleaning qualification and control method for fluid sample containers, which supports bottle cleanliness.
  • ISO 5598 - provides the general fluid power vocabulary used for terms and definitions.
  • ISO 11171 - covers calibration of automatic particle counters for liquids, which supports online and laboratory particle counting.
  • ISO 11943 - covers calibration and validation of online automatic particle-counting systems for liquids.
  • ISO 21018-1 - gives the general principles for monitoring particulate contamination in fluid, especially for online analysis.

What does the ISO/PRF 4021 document contain?

The document contains practical sampling guidance rather than contamination limits or reporting classes. Figures illustrate a typical line sampler, a recommended bypass circuit for online analysis, a reservoir vacuum sampler, and a reservoir shut-off valve sampler.

Its main body covers sampling point selection, sample bottles, solvent choice, sampling frequency, line and reservoir sampling principles, and step-by-step offline and online procedures. It also includes bottle labelling information and an identification statement for users who want to claim conformity in reports or product literature.

Annex A gives the Reynolds number calculation used to support the flow-condition check for turbulent sampling. The bibliography cites ISO 4406 for contamination coding by solid particles.

Relations

Effective Date
26-Apr-2025

Buy Documents

Draft

ISO/PRF 4021 - Hydraulic fluid power — Particulate contamination analysis — Extraction of fluid samples from lines of an operating system

Release Date:17-Nov-2026
English language (14 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/PRF 4021 - Hydraulic fluid power — Particulate contamination analysis — Extraction of fluid samples from lines of an operating system

Release Date:17-Nov-2026
English language (14 pages)
sale 15% off
sale 15% off

Get Certified

Connect with accredited certification bodies for this standard

Institut za varilstvo d.o.o. (Welding Institute)

Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

ISO/PRF 4021 is a draft published by the International Organization for Standardization (ISO). Its full title is "Hydraulic fluid power — Particulate contamination analysis — Extraction of fluid samples from lines of an operating system". This standard covers: The preferred method is to extract fluid samples from a main flowline in such a manner that the particulate contaminant in the sample is representative of the fluid flowing at the point of sampling. An alternative method is to extract a sample from the reservoir, but this method should only be used if a suitable sampler is not fitted.

The preferred method is to extract fluid samples from a main flowline in such a manner that the particulate contaminant in the sample is representative of the fluid flowing at the point of sampling. An alternative method is to extract a sample from the reservoir, but this method should only be used if a suitable sampler is not fitted.

ISO/PRF 4021 is classified under the following ICS (International Classification for Standards) categories: 23.100.60 - Filters, seals and contamination of fluids. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO/PRF 4021 has the following relationships with other standards: It is inter standard links to ISO 4021:1992. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO/PRF 4021 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 sampler
  • 3.2 turbulent flow
  • 4 Sampling point
  • 4.1 General
  • 4.2 Sampling locations
  • 5 Supplies and materials
  • 5.1 Sample bottles
  • 5.2 Solvent
  • 6 Sampling frequency
  • 6.1 General
  • 6.2 Sampling timing
  • 7 Sampling principles
  • 7.1 Sampling from fluid lines
  • 7.2 Sampling from reservoirs
  • 8 Sampling procedures
  • 8.1 Offline analysis sampling procedure
  • 8.2 Online analysis sampling procedure
  • 9 Labelling
  • 10 Identification statement
  • Annex A
  • Bibliography

Introduction

In hydraulic fluid power systems, power is transmitted through the fluid under pressure within a closed circuit. The fluid is both a lubricant and power-transmitting medium. The presence of solid particulate contamination in the fluid interferes with the ability of the hydraulic fluid to lubricate and causes wear to the components. The extent of this form of contamination in the fluid has a direct bearing on the performance and reliability of the system, and it is necessary that this be controlled to levels that are considered appropriate for the system concerned. Hydraulic filters are used to control the amount of particulate contamination to a level that is suitable for both the contaminant sensitivity of the system and the level of reliability required by the users.

Operators and manufacturers of hydraulic equipment have defined maximum particle concentration levels for components, systems and processes, beyond which corrective actions are implemented to normalize the levels. These are often referred to as the required cleanliness level (RCL). The cleanliness level is obtained by sampling the hydraulic fluid and measuring the particulate contamination level. If the level is above the RCL, then corrective actions are necessary to restore the situation. To avoid taking unnecessary actions, which can often prove costly, precision in sampling and measuring the particulate contamination level is required. PROOF/ÉPREUVE

International Standard ISO 4021:2026(en) Hydraulic fluid power — Particulate contamination analysis - Extraction of fluid samples from lines of an operating system

1 Scope

This document specifies procedures for extracting fluid samples from a hydraulic fluid power system under operation.

The preferred method is to extract fluid samples from a main flowline of an operating hydraulic system in such manner that the particulate contaminant in the sample is representative of the fluid flowing at the point of sampling.

This document can be used for offline and online sampling. The samples taken are used for particulate contamination analysis.

NOTE An alternative method is to extract a sample from the reservoir of an operating hydraulic system if a suitable sampling device is not fitted.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3722, Hydraulic fluid power — Fluid sample containers — Qualifying and controlling cleaning methods ISO 5598, Fluid power systems and components — Vocabulary ISO 11171, Hydraulic fluid power — Calibration of automatic particle counters for liquids ISO 11943, Hydraulic fluid power — Online automatic particle-counting systems for liquids — Methods of calibration and validation ISO 21018-1, Hydraulic fluid power — Monitoring the level of particulate contamination of the fluid — Part 1:

General principles

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 5598 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

3.1 sampler

device for extracting a representative sample from a larger source PROOF/ÉPREUVE

ISO 4021:2026(en)

3.2 turbulent flow

fluid flow in which particle movement, anywhere in the flow, varies rapidly in velocity and direction Note 1 to entry: Flow can be turbulent when the Reynolds number, Re, is greater than 2 300 and is usually assumed to be turbulent when Re ≥ 4 000, see Annex A.

4 Sampling point

4.1 General

Sampling points are usually as follow:

  • depend on the purpose of extracting fluid samples;
  • shall be chosen to collect representative samples;
  • shall be selected in an easy-to-operate area for online analysis or extraction of fluid samples.

4.2 Sampling locations

For the purpose of extracting fluid samples, the user may take samples from one or more locations of the hydraulic system. Sampling locations for hydraulic systems include, but are not limited to:

  • Upstream of the return line filter. The fluid sample taken at this location can characterize the contamination level of the hydraulic system and usually used to diagnose its operating condition. This location can be preferred if the user is interested to determine the contamination level of the hydraulic system.
  • Downstream of the pressure line filter. The fluid sample taken at this location can characterize the contamination level of fluid entering to servo valves, proportional valves and actuators of the hydraulic system. This location can be preferred if it is not convenient for sampling from upstream of the return line filter or the user is interested to determine the performance of the pressure line filter.
  • Upstream of the pressure line filter. The fluid sample taken at this location can indirectly reflect the contamination level of the fluid in the reservoir and the contamination status of hydraulic pump. This location can be considered if the user wants to know the contamination level of the fluid in the reservoir but cannot extract samples from reservoir directly.
  • Downstream of the return line filter. The fluid sample taken at this location can characterize the contamination level of fluid returned to the reservoir and indirectly reflect the effectiveness of the return line filter settings. This location can be considered if the user wants to know the contamination level of fluid returned to the reservoir either the performance of the return line filter, or both.
  • The case drains of hydraulic pump/motor. The fluid sample taken at this location can characterize the contamination level of the hydraulic pump/motor. Due to particles produced by pump/motor wear, the case drain of the hydraulic pump/motor may be the most contaminated part of the hydraulic system. This sample point is not recommended as the flow is not turbulent and the contaminant can sediment. But this location can be considered if the user wants to know the wear condition of the hydraulic pump/ motor.
  • The reservoir. If direct sampling from the lines of the hydraulic system is not possible, users can consider sampling from the reservoir. When sampling from the reservoir, the static area of the fluid shall be avoided. The hydraulic system shall be operated for a sufficient duration to create a homogeneous mixture.

NOTE 1 Contaminants external to the hydraulic system during sampling can adversely impact sample quality. Potential sources of external contamination include from hydraulic lines/fittings of the sampler and the environment. NOTE 2 For a hydraulic system with a permanent or temporary bypass filter, the contamination level of fluid extracted permanently from the reservoir can be influenced by the performance of the temporary offline filter. PROOF/ÉPREUVE

ISO 4021:2026(en)

5 Supplies and materials

5.1 Sample bottles

5.1.1 Material

The material of sample bottles shall be chemically compatible with fluid samples and suitable for the temperature range of fluid samples. It should be colourless and transparent to enable viewing of the height and condition of the fluid sample. Materials that tend to generate particles in fluid samples shall not be used. NOTE Plastic type bottles have static electricity effects which can cause particles to stick to the insides of containers particularly opposite fingerprints.

5.1.2 Appearance

The inner surface and opening of sample bottles shall be smooth, with rounded corners at the bottom to prevent the solid particle retention. Bottles with wide mouth and flat bottom should be used for easy cleaning. Bottles with ground glass shall not be used.

5.1.3 Sealing

The mouth of the sample bottle shall have seals for transport and prevention of secondary contamination. The sealing system should be easy to clean and shall not have any under cuts. A sealed cap shall be used, which can be either a threaded type without an inner plug or a cap with an inner sealing gasket.

5.1.4 Specifications

The specifications of sample bottles shall be consistent with the sampler type of the measuring instrument used and the volume of the fluid sample to be tested, and the sample bottle volume should not be less than 100 ml.

5.1.5 Cleanliness level

Sample bottles shall be cleaned and verified in accordance with ISO 3722. The sample bottles shall be as clean as possible so as not to introduce secondary contamination into the sample.

5.2 Solvent

The solvent shall be compatible with the sample and have a contamination level lower than 14/12/9 (see [1] ISO 4406 ). For mineral oil-based samples, petroleum ether is advisable. For water-based samples, isopropyl alcohol is recommended.

WARNING — Petroleum ether and isopropyl alcohol are hazardous. The user must establish appropriate safeguards per the safety data sheets and local requirements.

6 Sampling frequency

6.1 General

Sampling should be performed regularly by the operator to determine the particulate contamination level of the hydraulic system. Sampling intervals can be optimized by taking into account the following hydraulic system and application-specific conditions:

a) Criticality: safety, environmental, downtime, repair and business interruption failure consequences; b) Operational and fluid environment conditions: these influence frequency and rate of hydraulic system and fluid failure. They include pressure, load, temperature, speed, contaminant ingression rate, wear rate and duty cycle severity; PROOF/ÉPREUVE

...

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 sampler, noun
  • 3.2 turbulent flow, noun
  • 4 Sampling point
  • 4.1 General
  • 4.2 Sampling locations
  • 5 Supplies and materials
  • 5.1 Sample bottles
  • 5.2 Solvent
  • 6 Sampling frequency
  • 6.1 General
  • 6.2 Sampling timing
  • 7 Sampling principles
  • 7.1 Sampling from fluid lines
  • 7.2 Sampling from reservoirs
  • 8 Sampling procedures
  • 8.1 Offline analysis sampling procedure
  • 8.2 Online analysis sampling procedure
  • 9 Labelling
  • 10 Identification statement
  • Annex A
  • Bibliography

Introduction

In hydraulic fluid power systems, power is transmitted through the fluid under pressure within a closed circuit. The fluid is both a lubricant and power-transmitting medium. The presence of solid particulate contamination in the fluid interferes with the ability of the hydraulic fluid to lubricate and causes wear to the components. The extent of this form of contamination in the fluid has a direct bearing on the performance and reliability of the system, and it is necessary that this be controlled to levels that are considered appropriate for the system concerned. Hydraulic filters are used to control the amount of particulate contamination to a level that is suitable for both the contaminant sensitivity of the system and the level of reliability required by the users.

Operators and manufacturers of hydraulic equipment have defined maximum particle concentration levels for components, systems and processes, beyond which corrective actions are implemented to normalize the levels. These are often referred to as the required cleanliness level (RCL). The cleanliness level is obtained by sampling the hydraulic fluid and measuring the particulate contamination level. If the level is above the RCL, then corrective actions are necessary to restore the situation. To avoid taking unnecessary actions, which can often prove costly, precision in sampling and measuring the particulate contamination level is required.

ISO/PRF 4021:2026(en) Hydraulic fluid power — Particulate contamination analysis — Extraction of fluid samples from lines of an operating system

1 Scope

This document specifies procedures for extracting fluid samples from a hydraulic fluid power system under operation.

The preferred method is to extract fluid samples from a main flowline of an operating hydraulic system in such manner that the particulate contaminant in the sample is representative of the fluid flowing at the point of sampling.

This document can be used for offline and online sampling. The samples taken are used for particulate contamination analysis.

NOTE An alternative method is to extract a sample from the reservoir of an operating hydraulic system if a suitable sampling device is not fitted.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3722, Hydraulic fluid power — Fluid sample containers — Qualifying and controlling cleaning methods ISO 5598, Fluid power systems and components — Vocabulary ISO 11171, Hydraulic fluid power — Calibration of automatic particle counters for liquids ISO 11943, Hydraulic fluid power — Online automatic particle-counting systems for liquids — Methods of calibration and validation ISO 21018-1, Hydraulic fluid power — Monitoring the level of particulate contamination of the fluid — Part 1:

General principles

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 5598 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp
  • IEC Electropedia: available at https://www.electropedia.org/

3.1 sampler, noun

device for extracting a representative sample from a larger source

3.2 turbulent flow, noun

fluid flow in which particle movement, anywhere in the flow, varies rapidly in velocity and direction

ISO/PRF 4021:2026(en) Note 1 to entry: Flow can be turbulent when the Reynolds number (, Re), is greater than 2 300 and is usually assumed to be turbulent when Re≥ ≥ 4 000. See, see Annex A.

4 Sampling point

4.1 General

Sampling points are usually as follow:

  • depend on the purpose of extracting fluid samples;
  • shall be chosen to collect representative samples;
  • shall be selected in an easy-to-operate area for online analysis or extraction of fluid samples.

4.2 Sampling locations

For the purpose of extracting fluid samples, the user may take samples from one or more locations of the hydraulic system. Sampling locations for hydraulic systems include, but are not limited to:

  • Upstream of the return line filter. The fluid sample taken at this location can characterize the contamination level of the hydraulic system and usually used to diagnose its operating condition. This location can be preferred if the user is interested to determine the contamination level of the hydraulic system.
  • Downstream of the pressure line filter. The fluid sample taken at this location can characterize the contamination level of fluid entering to servo valves, proportional valves and actuators of the hydraulic system. This location can be preferred if it is not convenient for sampling from upstream of the return line filter or the user is interested to determine the performance of the pressure line filter.
  • Upstream of the pressure line filter. The fluid sample taken at this location can indirectly reflect the contamination level of the fluid in the reservoir and the contamination status of hydraulic pump. This location can be considered if the user wants to know the contamination level of the fluid in the reservoir but can’tcannot extract samples from reservoir directly.

- Downstream of the return line filter. The fluid sample taken at this location can characterize the contamination level of fluid returned to the reservoir and indirectly reflect the effectiveness of the return line filter settings. This location can be considered if the user wants to know the contamination level of fluid returned to the reservoir and/oreither the performance of the return line filter, or both. - The case drains of hydraulic pump/motor. The fluid sample taken at this location can characterize the contamination level of the hydraulic pump/motor. Due to particles produced by pump/motor wear, the case drain of the hydraulic pump/motor may be the most contaminated part of the hydraulic system. This sample point is not recommended as the flow is not turbulent and the contaminant can sediment. But this location can be considered if the user wants to know the wear condition of the hydraulic pump/motor. - The reservoir. If direct sampling from the lines of the hydraulic system is not possible, users can consider sampling from the reservoir. When sampling from the reservoir, the static area of the fluid shall be avoided. The hydraulic system shall be operated for a sufficient duration to create a homogeneous mixture. NOTE 1 Contaminants external to the hydraulic system during sampling can adversely impact sample quality. Potential sources of external contamination include from hydraulic lines/fittings of the sampler and the environment. NOTE 2 For a hydraulic system with a permanent or temporary bypass filter, the contamination level of fluid extracted permanently from the reservoir can be influenced by the performance of the temporary offline filter.

ISO/PRF 4021:2026(en)

5 Supplies and materials

5.1 Sample bottles

5.1.1 Material

The material of sample bottles shall be chemically compatible with fluid samples, and suitable for the temperature range of fluid samples. It should be colourless and transparent to enable viewing of the height and condition of the fluid sample. Materials that tend to generate particles in fluid samples shall not be used. NOTE Plastic type bottles have static electricity effects which can cause particles to stick to the insides of containers particularly opposite fingerprints.

5.1.2 Appearance

The inner surface and opening of sample bottles shall be smooth, with rounded corners at the bottom to prevent the solid particle retention. Bottles with wide mouth and flat bottom should be used for easy cleaning. Bottles with ground glass shall not be used.

5.1.3 Sealing

The mouth of the sample bottle shall have seals for transport and prevention of secondary contamination. The sealing system should be easy to clean and shall not have any under cuts. A sealed cap shall be used, which can be either a threaded type without an inner plug or a cap with an inner sealing gasket.

5.1.4 Specifications

The specifications of sample bottles shall be consistent with the sampler type of the measuring instrument used and the volume of the fluid sample to be tested, and the sample bottle volume should not be less than 100 ml.

5.1.5 Cleanliness level

Sample bottles shouldshall be cleaned and verified in accordance with ISO 3722. The sample bottles shouldshall be as clean as possible so as not to introduce secondary contamination into the sample.

5.2 Solvent

The solvent shall be compatible with the sample and have a contamination level lower than 14/12/9 (see ISO [1] 4406 ). For mineral oil-based samples, petroleum ether is advisable. For water-based samples, isopropyl alcohol is recommended.

WARNING — Petroleum ether and isopropyl alcohol are hazardous. The user shallmust establish appropriate safeguards per the Safety Data Sheetssafety data sheets and local requirements.

6 Sampling frequency

6.1 General

Sampling should be performed regularly by the operator to determine the particulate contamination level of the hydraulic system. Sampling intervals can be optimized by taking into account the following hydraulic system and application-specific conditions:

a) Criticality: safety, environmental, downtime, repair and business interruption failure consequences;

...