IEC 61169-1:1992/AMD2:1997
(Amendment)Amendment 2 - Radio-frequency connectors - Part 1: Generic specification - General requirements and measuring methods
- Status
- Published
- Publication Date
- 15-May-1997
- Technical Committee
- SC 46F - RF and microwave passive components
- Drafting Committee
- WG 3 - TA 5/WG 3
- Current Stage
- DELPUB - Deleted publication - 99 Deleted
- Start Date
- 10-Jul-2013
Overview
IEC 61169-1:1992/AMD2:1997 is the second amendment to the international standard that specifies the generic requirements and measuring methods for radio-frequency (RF) connectors. Developed by the International Electrotechnical Commission (IEC) Subcommittee 46D, this amendment enhances the quality assurance and testing procedures critical for RF connector performance in communication and signaling systems. The document outlines detailed test methods, inspection protocols, and compliance requirements to ensure the reliability, mechanical compatibility, and electrical integrity of RF connectors used globally.
Key Topics
- Generic Specification of RF Connectors: Provides standardized general requirements applicable to various RF connector types, ensuring consistent quality and interchangeability.
- Test Schedules and Inspection: Introduces fixed-quantity sample procedures and lot-by-lot acceptance tests focusing on visual inspection, mechanical compatibility, engagement and separation, retention forces, and sealing performance.
- Quality Assurance Levels: Defines two assessment levels (M - higher, H - lower) with distinct acceptable quality levels (AQL) and inspection frequencies to tailor testing rigor based on application criticality.
- Test Groups:
- Groups A1 and B1: Lot-by-lot acceptance tests including visual checks and dimensional assessments.
- Groups D1 to D7: Periodic tests covering solderability, mechanical endurance, contact resistance, environmental resistance (humidity, salt mist, solvents), electrical performance (voltage proof, insulation resistance), and climatic endurance.
- Destructive Testing Clarification: Specifies that destructive test specimens must not be returned to stock, reinforcing strict quality control.
- Qualification and Maintenance: Details procedures for qualification approval requiring consecutive successful lot inspections and continuous compliance through periodic testing for sustained product reliability.
Applications
IEC 61169-1 Amendment 2 applies predominantly to manufacturers, test laboratories, and quality assurance teams involved in producing and validating RF connectors for:
- Telecommunications infrastructure and wireless communication devices.
- Signal transmission equipment in aerospace, defense, and automotive industries.
- Broadcast and radio transmission systems.
- High-frequency electronic assemblies demanding consistent connector performance.
- Design and development of connectors ensuring mechanical, electrical, and environmental compliance globally.
By adhering to this amendment, stakeholders ensure connectors meet rigorous international standards, reducing failure risk and enhancing interoperability in complex RF communication networks.
Related Standards
- IEC 61169 Series: Covers specifications for various types of RF connectors including dimensions, interfaces, and performance criteria.
- IEC 60297: Related mechanical standards for connectors and rack assemblies.
- IEC 60068: Environmental testing standards that align with ruggedness and endurance tests referenced in this amendment.
- ISO 9001: Quality management systems providing foundational processes that complement the testing and inspection methods specified here.
Keywords: IEC 61169-1 Amendment 2, radio-frequency connectors, RF connector standards, quality assurance testing, lot-by-lot inspection, mechanical compatibility, electrical performance, solderability tests, environmental resistance, qualification approval, IEC standards for RF connectors
Relations
- Effective Date
- 05-Sep-2023
- Effective Date
- 05-Sep-2023
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
IEC 61169-1:1992/AMD2:1997 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Amendment 2 - Radio-frequency connectors - Part 1: Generic specification - General requirements and measuring methods". This standard covers: Amendment 2 - Radio-frequency connectors - Part 1: Generic specification - General requirements and measuring methods
Amendment 2 - Radio-frequency connectors - Part 1: Generic specification - General requirements and measuring methods
IEC 61169-1:1992/AMD2:1997 is classified under the following ICS (International Classification for Standards) categories: 33.120.30 - RF connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61169-1:1992/AMD2:1997 has the following relationships with other standards: It is inter standard links to IEC 61169-1:1992, IEC 61169-1:2013. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 61169-1:1992/AMD2:1997 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
NORME
CEI
INTERNATIONALE
IEC
61169-1
INTERNATIONAL
QC 220000
STANDARD
AMENDEMENT 2
AMENDMENT 2
1997-04
Amendement 2
Connecteurs pour fréquences radioélectriques –
Partie 1:
Spécification générique –
Prescriptions générales et méthodes de mesure
Amendment 2
Radio-frequency connectors –
Part 1:
Generic specification –
General requirements and measuring methods
IEC 1997 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
PRICE CODE E
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61169-1 amend. 2 © CEI:1997
AVANT-PROPOS
Le présent amendement a été établi par le sous-comité 46D: Connecteurs pour fréquences
radioélectriques, du comité d’études 46 de la CEI: Câbles, fils, guides d’ondes, connecteurs et
accessoires pour communications et signalisation.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
46D/279/FDIS 46D/296/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
________
Page 150
Ajouter, après le paragraphe 10.3.2.3, le nouveau paragraphe suivant:
10.3.3 Programme d’essai et exigences de contrôle pour la procédure du prélèvement fixe
Tableau 1 – Procédure lot par lot – Essais d’acceptation: groupes A1 et B1
Méthode
Niveau d’assurance M (haut) Niveau d’assurance H (bas)
d’essai
de la CEI
61169-1
Test NQA Périodi- Test NQA Périodi-
QC 220000
NC NC
requis % cité requis % cité
Paragraphe
Groupe A1
Examen visuel
9.1.2 a 11 1,0 a S3 1,5
Groupe B1
Dimensions extérieures
9.1.3.1 a S4 0,40 a S3 0,40
Compatibilité mécanique
9.1.3.3 a 11 1,0 a S3 1,5
Accouplement et désaccouplement
9.3.6 a S4 0,40 a S3 1,5
Lot Lot
Rétention du calibre
9.3.4 ia 11 1,0 ia S3 1,5
(contacts élastiques)
par par
Etanchéité sans herméticité
9.4.5.1 ia 11 0,65 ia S3 1,0
Etanchéité avec herméticité
9.4.5.2 ia 11 0,015 ia S3 0,025
lot lot
Tension de tenue
9.2.6 a S4 0,40 a 11 4,0
d)
Soudabilité pièces détachées
9.3.2.1.1 ia S4 0,40 ia S3 4,0
Résistance d’isolement
9.2.5 a S4 0,40 a S3 4,0
Efficacité du fil des trous de
TBD ia S4 0,40 ia S3 4,0
sécurité
a applicable
ia test requis (si techniquement applicable)
NC niveau de contrôle
NQA niveau de qualité acceptable
d)
essais destructifs. Les spécimens ne doivent pas être remis en stock.
61169-1 Amend. 2 © IEC:1997 – 3 –
FOREWORD
This amendment has been prepared by the subcommittee 46D: RF connectors, of IEC
technical committee 46: Cables, wires, waveguides, RF connectors, and accessories for
communication and signalling.
The text of this amendment is based on the following documents:
FDIS Report on voting
46D/279/FDIS 46D/296/RVD
Full information on the voting for the approval of this amendment can be found in the report on
voting indicated in the above table.
________
Page 151
Add, after subclause 10.3.2.3, the following new subclause
10.3.3 Test schedules and inspection requirements for alternative fixed-quantity sample procedures
Table 1 – Lot-by-lot procedure – Acceptance tests: groups A1 and B1
Test
Assessment level M (higher) Assessment level H (lower)
method
of IEC
61169-1
Test AQL Period Test AQL Period
QC 220000
IL IL
required % required %
Subclause
Group A1
Visual inspection
9.1.2 a 11 1,0 a S3 1,5
Group B1
Outline dimensions
9.1.3.1 a S4 0,40 a S3 0,40
Mechanical compatibility
9.1.3.3 a 11 1,0 a S3 1,5
Engagement and separation
9.3.6 a S4 0,40 a S3 1,5
Lot Lot
Gauge retention force
9.3.4 ia 11 1,0 ia S3 1,5
(resilient contacts)
by by
Scaling, non-hermetic
9.4.5.1 ia 11 0,65 ia S3 1,0
Scaling, hermetic
9.4.5.2 ia 11 0,015 ia S3 0,025
lot lot
Voltage proof
9.2.6 a S4 0,40 a 11 4,0
d)
Solderability piece-parts
9.3.2.1.1 ia S4 0,40 ia S3 4,0
Insulation resistance
9.2.5 a S4 0,40 a S3 4,0
Effectiveness of safety wire locking
TBD ia S4 0,40 ia S3 4,0
d)
holes; piece-parts
a applicable
ia test required (if technically applicable)
IL inspection level
AQL acceptable quality level
d)
destructive tests – specimens shall not be returned to stock.
– 4 – 61169-1 amend. 2 © CEI:1997
Tableau 2 – Procédure de prélèvement fixe – Séquence initiale d’essais groupe 0
Méthode
Niveau d’assurance M (haut) Niveau d’assurance H (bas)
d’essai
de la CEI
61169-1
Test Nombre Test Nombre
QC 220000
requis d’échantillons requis d’échantillons
Paragraphe
Groupe 0
Examen visuel
9.1.2 a a
Dimensions extérieures
9.1.3.1 a a
Compatibilité mécanique
9.1.3.3 a a
Accouplement et désaccouplement
9.3.6 a a
ia ia
Rétention du calibre
9.3.4
36 minimum 18 minimum
(contacts élastiques)
ia
ia
Etanchéité sans herméticité
9.4.5.1
ia
ia
Etanchéité avec herméticité
9.4.5.2
a
a
Tension de tenue
9.2.6
ia
d)
ia
Soudabilité pièces détachées
9.3.2.1.1
a
Résistance d’isolement a
9.2.5
a applicable
ia test requis (si techniquement applicable)
d)
essais destructifs. Les spécimens ne doivent pas être remis en stock
61169-1 Amend. 2 © IEC:1997 – 5 –
Table 2 – Fixed quantity sample procedure – Initial QA test sequence: group 0
Test
Assessment level M (higher) Assessment level H (lower)
method
of IEC
61169-1
Test Number Test Number
QC 220000
required of specimens required of specimens
Subclause
Group 0
Visual inspection
9.1.2 a a
Outline dimensions
9.1.3.1 a a
Mechanical compatibility
9.1.3.3 a a
Engagement and separation
9.3.6 a a
ia ia
Gauge retention force
9.3.4
36 minimum 18 minim
...