IEC PAS 60603-7-3:2004
(Main)Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz
- Abstract
Covers connectors to be used up to 100 MHz when used with appropriate cables, as specified in IEC 61156 and used in cabling systems laid down in ISO/IEC 11801. These connectors are intermateable, interoperable, and backward compatible with other IEC 60603-7 series connectors.
- Status
- Replaced
- Publication Date
- 03-Nov-2004
- Technical Committee
- SC 48B - Electrical connectors
- Drafting Committee
- WG 3 - TA 5/WG 3
- Current Stage
- DELPUB - Deleted publication - 99 Deleted
- Start Date
- 30-Jan-2008
Buy Documents
IEC PAS 60603-7-3:2004 - Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz Released:11/4/2004
Relations
- Effective Date
- 05-Sep-2023
Buy Documents
IEC PAS 60603-7-3:2004 - Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz Released:11/4/2004
Frequently Asked Questions
IEC PAS 60603-7-3:2004 is a technical specification published by the International Electrotechnical Commission (IEC). Its full title is "Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz". This standard covers: Covers connectors to be used up to 100 MHz when used with appropriate cables, as specified in IEC 61156 and used in cabling systems laid down in ISO/IEC 11801. These connectors are intermateable, interoperable, and backward compatible with other IEC 60603-7 series connectors.
Covers connectors to be used up to 100 MHz when used with appropriate cables, as specified in IEC 61156 and used in cabling systems laid down in ISO/IEC 11801. These connectors are intermateable, interoperable, and backward compatible with other IEC 60603-7 series connectors.
IEC PAS 60603-7-3:2004 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC PAS 60603-7-3:2004 has the following relationships with other standards: It is inter standard links to IEC 60603-7-3:2008. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC PAS 60603-7-3:2004 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
PUBLICLY
IEC
AVAILABLE
PAS 60603-7-3
SPECIFICATION
First edition
Pre-Standard
2004-11
Connectors for electronic equipment –
Part 7-3:
Detail specification for 8-way, shielded,
free and fixed connectors, for data transmissions
with frequencies up to 100 MHz
Reference number
IEC/PAS 60603-7-3:2004(E)
Publication numbering
As from 1 January 1997 all IEC publications are issued with a designation in the
60000 series. For example, IEC 34-1 is now referred to as IEC 60034-1.
Consolidated editions
The IEC is now publishing consolidated versions of its publications. For example,
edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the
base publication incorporating amendment 1 and the base publication incorporating
amendments 1 and 2.
Further information on IEC publications
The technical content of IEC publications is kept under constant review by the IEC,
thus ensuring that the content reflects current technology. Information relating to
this publication, including its validity, is available in the IEC Catalogue of
publications (see below) in addition to new editions, amendments and corrigenda.
Information on the subjects under consideration and work in progress undertaken
by the technical committee which has prepared this publication, as well as the list
of publications issued, is also available from the following:
• IEC Web Site (www.iec.ch)
• Catalogue of IEC publications
The on-line catalogue on the IEC web site (www.iec.ch/searchpub) enables you to
search by a variety of criteria including text searches, technical committees
and date of publication. On-line information is also available on recently issued
publications, withdrawn and replaced publications, as well as corrigenda.
• IEC Just Published
This summary of recently issued publications (www.iec.ch/online_news/ justpub)
is also available by email. Please contact the Customer Service Centre (see
below) for further information.
• Customer Service Centre
If you have any questions regarding this publication or need further assistance,
please contact the Customer Service Centre:
Email: custserv@iec.ch
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
PUBLICLY
IEC
AVAILABLE
PAS 60603-7-3
SPECIFICATION
First edition
Pre-Standard
2004-11
Connectors for electronic equipment –
Part 7-3:
Detail specification for 8-way, shielded,
free and fixed connectors, for data transmissions
with frequencies up to 100 MHz
© IEC 2004 ⎯ Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or
mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale
XC
International Electrotechnical Commission
Международная Электротехническая Комиссия
For price, see current catalogue
– 2 – PAS 60603-7-3 © IEC:2004 (E)
CONTENTS
Page
FOREWORD.6
Clause
1 General .7
1.1 Scope.7
1.2 Normative references .7
2 Technical information .9
2.1 Terminology .9
2.2 Interchangeability levels .9
2.2.1 General .9
2.2.2 Intermateability .9
2.2.3 Backward Compatibility .9
2.2.4 Interoperability.9
2.3 IEC type designation.10
3 Common features and isometric view .11
3.1 Isometric view .11
3.2 Mating information for connectors with cables attached .11
3.2.1 General .11
3.2.2 Contacts .12
3.2.3 Fixed connector .14
3.2.4 Free connector (contacts not shown) .17
4 Cable terminations and internal connections – Fixed and free connectors .19
4.1 General .19
4.2 Termination Types .19
4.2.1 Solder terminations .19
4.2.2 Insulation displacement terminations .19
4.2.3 Crimp terminations.19
4.2.4 Insulation piercing terminations .19
4.2.5 Press-in connections (compliant pin (UC)) .19
4.2.6 Spring-clamp terminations.19
4.2.7 Other types.19
5 Gauges .20
5.1 Fixed connectors .20
5.2 Free connectors .22
6 Characteristics .25
6.1 General .25
6.2 Pin and pair grouping assignment. .25
6.3 Classification into climatic category.25
6.4 Electrical .26
6.4.1 Creepage and clearance distances.26
6.4.2 Voltage proof .26
6.4.3 Current-carrying capacity .26
6.4.4 Mating cycles with power applied .27
6.4.5 Initial contact resistance between separable fixed and free
connectors.27
PAS 60603-7-3 © IEC:2004 (E) – 3 –
6.4.6 Input to output d.c. resistance .27
6.4.7 Input to output d.c. resistance unbalance.28
6.4.8 Insulation resistance .28
6.4.9 Transfer impedance .28
6.5 Transmission characteristics.28
6.5.1 General .28
6.5.2 Insertion loss .28
6.5.3 Return loss .29
6.5.4 Propagation delay .29
6.5.5 Delay skew .29
6.5.6 NEXT loss .29
6.5.7 Power sum NEXT loss (for information only) .29
6.5.8 FEXT Loss.29
6.5.9 Power sum FEXT loss (for information only) .30
6.5.10 Transverse conversion loss .30
6.5.11 Coupling attenuation .30
6.6 Mechanical.30
6.6.1 Mechanical operation .30
6.6.2 Effectiveness of connector coupling devices .30
6.6.3 Insertion and withdrawal forces .30
7 Tests and test schedule .31
7.1 General .31
7.2 Arrangement for contact resistance test: .32
7.3 Arrangement for vibration test (test phase CP1) .33
7.4 Test procedures and measuring methods .33
7.5 Preconditioning.34
7.6 Wiring and mounting of specimens.34
7.6.1 Wiring.34
7.6.2 Mounting.34
7.7 Test schedules .34
7.7.1 Basic (minimum) test schedule .34
7.7.2 Full test schedule.34
Annex A (normative) Gauging continuity procedure.41
A.1 Object .41
A.2 Preparation of the specimens.41
A.3 Test method .41
A.4 Final measurements .41
A.5 Description of continuity gauge .42
Annex B (normative) Locking device mechanical operation .44
B.1 Object .44
B.2 Preparation of the specimens.44
B.3 Test method .44
B.4 Final measurements .44
Annex C (normative) Test Plug Requirements .45
C.1 General .45
C.2 De-embedding reference NEXT plug construction.45
C.3 Set-up and calibration.46
C.3.1 Port extension .46
– 4 – PAS 60603-7-3 © IEC:2004 (E)
C.4 De-embedding reference plug NEXT measurement.48
C.5 De-embedding reference NEXT jack construction .48
C.5.1 De-embedding reference NEXT jack selection.48
C.6 De-embedding reference jack NEXT measurement .49
C.7 Test plug construction.49
C.8 Test plug NEXT measurement .49
C.9 Test plug NEXT requirements .51
C.10 Connector NEXT testing .51
C.11 Test plug FEXT loss test procedure – de-embedding method.52
C.12 Return Loss Reference Plug .52
C.13 Connector Return Loss Measurement Requirements .52
Annex D (normative) General requirements for the measurement set-up .53
D.1 Test instrumentation .53
D.2 Coaxial cables and test leads for network analysers .53
D.3 Measurement precautions.53
D.4 Balun requirements.54
D.5 Reference components for calibration .55
D.6 Termination loads for termination of conductor pairs.56
D.7 Termination of screens .57
D.8 Test specimen and reference planes .57
Annex E (normative) Insertion loss.58
E.1 Object .58
E.2 Test method .58
E.3 Tests set-up .58
E.4 Procedure .58
E.5 Test report .59
E.6 Accuracy .59
Annex F (normative) Return loss .60
F.1 Object .60
F.2 Test method .60
F.3 Test set-up .60
F.4 Procedure .60
F.5 Test report .60
F.6 Accuracy .60
Annex G (normative) Near end cross talk .62
G.1 Object .62
G.2 Test method .62
G.3 Test set-up .62
G.4 Procedure .63
G.5 Test report .63
G.6 Accuracy .63
Annex H (normative) Far end cross talk.64
H.1 Object .64
H.2 Test method .64
H.3 Test set-up .64
H.4 Procedure .65
H.5 Test report .65
H.6 Accuracy .65
PAS 60603-7-3 © IEC:2004 (E) – 5 –
Annex I (normative) Transfer Impedance .66
I.1 Object .66
I.2 Test method .66
I.3 Definitions .66
I.3.1 Inner and outer circuit .66
I.3.2 Coupling length.66
I.4 Test set-up .66
I.4.1 Preparation of test specimen .66
I.4.2 Triaxial set-up.67
I.4.3 Impedance of the inner circuit .68
I.4.4 Impedance matching networks .68
I.5 Procedure .70
I.5.1 Calibration .70
I.5.2 Measurement.70
I.5.3 Evaluation of test results .70
I.6 Test report .71
I.7 Accuracy .71
Annex J (normative) Transverse conversion loss and transfer conversion transverse
loss.72
J.1 Object .72
J.2 Test method .72
J.3 Test set-up .72
J.4 Procedure .73
J.4.1 Calibration .73
J.4.2 Noise floor .74
J.4.3 Measurement.74
J.5 Test report .74
J.6 Accuracy .74
Annex K (normative) Termination of balun .75
K.1 Termination of balun with low return loss for common-mode .75
Annex L (normative) Gauge requirements.76
L.1 Fixed Connectors .76
L.2 Free connectors: .76
Annex M (normative) Mating cycles with power applied.77
M.1 Object .77
M.2 Preparation of the specimens.77
M.2.1 General .77
M.2.2 Test circuit for signal conductors .77
M.2.3 Test circuit for screen .78
M.3 Test method .78
M.4 Final measurements .78
– 6 – PAS 60603-7-3 © IEC:2004 (E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
_____________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
Part 7-3: Detail specification for 8-way, shielded, free and fixed
connectors, for data transmissions with frequencies up to 100 MHz
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
A PAS is a technical specification not fulfilling the requirements for a standard but made
available to the public.
IEC-PAS 60603-7-3 has been processed by subcommittee 48B: Connectors, of IEC technical
committee 48: Electromechanical components and mechanical structures for electronic
equipment.
The text of this PAS is based on the This PAS was approved for
following document: publication by the P-members of the
committee concerned as indicated in
the following document
Draft PAS Report on voting
48B/1394/PAS 48B/1450/RVN
Following publication of this PAS, which is a pre-standard publication, the technical committee
or subcommittee concerned will transform it into an International Standard.
This PAS shall remain valid for an initial maximum period of three years starting from
2004. The validity may be extended for a single three-year period, following which it shall be
revised to become another type of normative document or shall be withdrawn.
PAS 60603-7-3 © IEC:2004 (E) – 7 –
CONNECTORS FOR ELECTRONIC EQUIPMENT –
Part 7-3: Detail specification for 8-way, shielded, free and fixed
connectors, for data transmissions with frequencies up to 100 MHz
1 General
1.1 Scope
This standard covers IEC 60603-7-3 connectors to be used up to 100 MHz when used with
appropriate cables. These cables are specified in IEC 61156 and used in cabling systems
specified in ISO/IEC 11801.
The connectors below are defined up to 100 MHz.
These connectors are intermateable, interoperable, and backward compatible with other IEC
60603-7 series connectors. While the definition of interoperable is being discussed within IEC,
“interoperable” in this standard means the following: The fixed and the free connector are
capable of interconnecting with any IEC 60603-7 series connector, and when they are
interconnected, fully meet all requirements of the lower frequency IEC 60603-7 series
standard.
1.2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60050-581, International Electrotechnical Vocabulary (IEV) – Chapter 581: Electro-
mechanical components for electronic equipment
IEC 60068-1, Environmental testing – Part 1: General and guidance
IEC 60068-2-14, Environmental testing – Part 2: Tests. Test N: Change of temperature
IEC 60068-2-38, Environmental testing – Part 2: Tests – Test Z/AD: Composite temperature/
humidity cyclic test
IEC 60169-16, Radio-frequency connectors – Part 16: R.F. coaxial connectors with inner
diameter of outer conductor 7 mm (0,276 in) with screw coupling – Characteristic impedance
50 ohms (75 ohms) (Type N)
IEC 60352-2, Solderless connections – Part 2: Solderless crimped connections − General
requirements, test methods and practical guidance
IEC 60352-3, Solderless connections – Part 3: Solderless accessible insulation displacement
− General requirements, test methods and practical guidance
connections
IEC 60352-4, Solderless connections – Part 4: Solderless non-accessible insulation
displacement connections− General requirements, test methods and practical guidance
IEC 60352-5, Solderless connections – Part 5: Press in connections − General requirements,
test methods and practical guidance
IEC 60352-6, Solderless connections – Part 6: Insulation piercing connections – General
requirements, test methods and practical guidance
– 8 – PAS 60603-7-3 © IEC:2004 (E)
IEC 60352-7, Solderless connections – Part 7: Spring clamp connections − General
requirements, test methods and practical guidance
IEC 60512-1, Connectors for electronic equipment – Tests and measurements – Part 1:
General
IEC 60512-2, Electromechanical components for electronic equipment, basic testing
procedures and measuring methods – Part 2: General examination, electrical continuity and
contact resistance tests, insulation tests and voltage stress tests
IEC 60512-3, Electromechanical components for electronic equipment; basic testing
procedures and measuring methods – Part 3: Current-carrying capacity tests
IEC 60512-4, Electromechanical components for electronic equipment; basic testing
procedures and measuring methods – Part 4: Dynamic stress tests
IEC 60512-5:1992, Electromechanical components for electronic equipment; basic testing
procedures and measuring methods – Part 5: Impact tests (free components), static load tests
(fixed components), endurance tests and overload tests
IEC 60512-8:1993, Electromechanical components for electronic equipment; basic testing
procedures and measuring methods – Part 8: Connector tests (mechanical) and mechanical
tests on contacts and terminations
IEC 60512-9, Electromechanical components for electronic equipment; basic testing
procedures and measuring methods – Part 9: Mechanical operation
IEC 60512-11, Electromechanical components for electronic equipment; basic testing
procedures and measuring methods – Part 11: Climatic tests
IEC 60512-13-2, Electromechanical components for electronic equipment; basic testing
procedures and measuring methods – Part 13-2: Mechanical operating tests – Insertion and
withdrawal forces
IEC 60512-15, Electromechanical components for electronic equipment; basic testing
procedures and measuring methods – Part 15: Mechanical tests on contacts and terminations
IEC 60664-1, Insulation coordination for equipment within low-voltage systems – Part 1:
Principles, requirements and tests
IEC 60603-1, Connectors for frequencies below 3 MHz for use with printed boards – Part 1:
Generic specification – General requirements and guide for the preparation of detail
specifications with assessed quality
IEC 60807-1, Rectangular connectors for frequencies below 3 MHz – Part 1: Generic
specification – General requirements and guide for the preparation of detail specifications for
connectors with assessed quality
IEC 61076-1, Connectors with assessed quality, for use in d.c., low-frequency analogue and
in digital high speed data applications – Part 1: Generic specification
IEC 61156 (all parts), Multi-core and symmetrical pair/quad cables for digital communications
ISO 11801 Information technology – Generic cabling for customer premises
ISO 1302, Geometrical Product Specifications (GPS) – Indication of surface texture in
technical product documentation
ITU-T K20, Resistibility of telecommunication equipment installed in a telecommunications
centre to overvoltages and overcurrents
PAS 60603-7-3 © IEC:2004 (E) – 9 –
ITU-T K44, Resistibility tests for telecommunication equipment exposed to overvoltages and
overcurrents – Basic Recommendation
ITU-T G.117: Transmission aspects of unbalance about earth
ITU-T O.9, Measuring arrangements to assess the degree of unbalance about earth
EN 50289-1-14, Communication cables – Specification for test methods – Part 1-14 –
Electrical test methods – Coupling attenuation or screening attenuation of connecting
hardware
2 Technical information
2.1 Terminology
The terminology used in and applicable to this specification is stated in 2.1 of IEC 61076-1.
Some applicable terms are also covered in IEC 60512-1.
(For definitions of terms used, refer to IEC 60050-581.)
2.2 Interchangeability levels
2.2.1 General
The connectors described in this standard are intermateable, interoperable and backward
compatible with all IEC 60603-7 series connectors.
2.2.2 Intermateability
Intermateability is ensured by applying the “GO” and “NO-GO” gauge requirements herein and
adherence to dimensional requirements given herein.
2.2.3 Backward Compatibility
The backward compatibility requirement ensures that a plug or jack which is in compliance
with this standard, mated with a jack or plug in compliance with any lower frequency IEC
60603-7 series connector, shall fully comply with the requirements of the lower frequency IEC
60603-7 series connector.
2.2.4 Interoperability
Interoperability of different IEC 60603-7-3 connectors is assured by compliance with all
transmission requirements when the fixed connector is mated with a full range of “test” free
connectors, or “test plugs”, as described herein.
– 10 – PAS 60603-7-3 © IEC:2004 (E)
2.3 IEC type designation
Connectors, connector bodies and connectors with pre-inserted contacts according to this
standard shall be designated by the following system:
IEC-PAS-60603-7-3 L N L L L N N N
Reference to Number denoting
this standard performance level
(PL)
750 operations
Letters denoting connector
2 500 operations
type 2
Fixed version
A
Free version
C
Number denoting variant
(not used yet)
Number of contacts
Number denoting contact finish
Gold, gold-alloy
Letters denoting type of contact Palladium/nickel
Female
F
Male
M
Letters denoting type of conductor
accommodation or cable
Tinsel wire
A
Letters denoting type of termination
Stranded wire
B
Screw terminal
A
Solid wire
C
Spring-clamp
B
Tinsel or stranded
D
Crimp
C
Stranded or solid wire
E
Insulation displacement (IDC)
D
Tinsel, stranded or solid wire
F
Insulation piercing
P
Board mounted
G
Solder
S
Customer specific requirements
X
Press-in connection
T for cables
Note: “L” stands for letter
“N” stands for number
Example:
IEC-PAS 60603-7-3 A8FD-E11-1: Fixed connector having 8 female contacts with IDC
termination for stranded and solid wire, gold plated, meeting performance level 1.
PAS 60603-7-3 © IEC:2004 (E) – 11 –
3 Common features and isometric view
3.1 Isometric view
Figure 1
3.2 Mating information for connectors with cables attached
3.2.1 General
Dimensions are given in millimetres. Drawings are shown in third-angle projection. The shape
of connectors may deviate from those shapes given in the following figures as long as the
specified dimensions are not influenced.
– 12 – PAS 60603-7-3 © IEC:2004 (E)
3.2.2 Contacts
Figure 2 – Contact interface dimensions with terminated free connector
Notes:
1: Female contact of fixed connector
2: Burrs shall not project above top of contact in this area, since it may be a contact area
3: Optional angle
4: Preferred contact interface detail
5: Preferred contact configuration
6: Optional contact configuration
PAS 60603-7-3 © IEC:2004 (E) – 13 –
Table 1
Letter Maximum Minimum
mm mm
A 1,45 0,89
B 0,61 0,51
C 0,46 0,03
D 2,79
E 4,11
F 6,22
H 0,38
J 0,64 0,38
K 6,15 5,89
M 0,30
N 0,28
P 0,50 0,45
P 0,50 0,36
R 4,83
Letter Maximum
G 10°
Care shall be taken that the contacts of the fixed connector avoid interference with the plastic
of the free connector.
– 14 – PAS 60603-7-3 © IEC:2004 (E)
3.2.3 Fixed connector
T1
Figure 3a – View of contact zone
Note:
1: Contact zone: female contacts shall be completely within their individual contact zone in the area
indicated
2: 0,15 mm maximum taper on both sides
3: Relief permitted on both sides
4: Section A – A: see figure 3b
PAS 60603-7-3 © IEC:2004 (E) – 15 –
Figure 3b – Section A - A
Note:
1: Optional contact rest
2: Preferred free connector stop
3: Contacts shown at rest.
Contacts shall always be contained inside guide slots
and shall move freely within their individual slots.
4: Surface need not be planar or coincident with the surface below the locking device as long as insertion,
latching and unlatching of free connectors is not inhibited.
5: Dimension to point of mating contact
6: Maximum forward extension of contacts below surface AC1, to avoid contact with shields of free
connectors. Applies in the mated state.
7: Flat surface
8: Projections beyond AL1 dimension shall not prevent finger access to free connector locking device
9: All internal corners in the connector cavity shall be 0,38 mm radius maximum unless otherwise specified.
– 16 – PAS 60603-7-3 © IEC:2004 (E)
Table 2
Letter Maximum Minimum Nominal (ref)
mm mm mm
A1 1,47
B1 0,71
K1 5,84
S1 12,04 11,84 11,94
T1 4,19 3,94
W1 6,38 6,22
X1 6,86 6,68
Y1 2,40
Z1 2,08
AA1 1,24
AB1 0,38
AC1 6,96 6,76 6,86
AD1 0,13
AH1 1,02
a)
TP
AK1 8,66 8,38
AL1 1,40
AM1 1,52
AP1 1,27
AS1 0,08
AT1 0,76
SA1 5,31
SB1 2,16
SD1 4,90
SE1 5,80
b)
SF1
a) TP indicates true position.
b) Care shall be taken that all screen contacts of the fixed connector always make contact
with the screen contacts of the free connector in worst-case condition to ensure reliable
performance
Letter Maximum Suggested minimum
AJ 15°
AN 3°30’
PAS 60603-7-3 © IEC:2004 (E) – 17 –
3.2.4 Free connector (contacts not shown)
Figure 4
Note:
1: Full radius permitted on all slots
2: These dimensions apply to the locations of the contact slots
3: Applies with locking device depressed
– 18 – PAS 60603-7-3 © IEC:2004 (E)
Table 3
Letter Maximum Minimum Nominal (ref)
mm mm mm
A2 a) a) 1,17
B2 a) a) 0,56
S2 11,79 11,58 11,68
T2 3,38 3,12
W2 6,17 6,02
X2 6,02 5,77
Y2 2,34
Z2 2,06
AA2 1,24
AB2 0,64 0,38
AC2 6,71 6,50 6,60
AD2 0,64 0,13
AH2 1,02
AW2 0,51
AX2 1,32
AY2 2,87 2,67
BA2 12,32
BB2 1,14 0,38
BC2 1,02 0,51
BD2 0.51
BE2 1,09
BF2 0,64
BG2 0,64 0,38
BH2 0,13
BL2 8,36
BM2 15,88 14,61
BN2 9.24
SA2 4,22
SB2 1,66
SD2 4.95
SE2 6.85
b)
SG2 1,50
a) See table 1.
b) When this dimension is less than 6,85 mm (ffs), and the free connector is mated with an IEC
60603-7-7 fixed connector, utilizing switch option 1, there is a possibility that signal
conductors 3,4,5,6 of the fixed connector may make contact with the screen of this free
connector.
Letter Maximum Nominal (ref)
BJ2 Full radius
BK2 3°30'
PAS 60603-7-3 © IEC:2004 (E) – 19 –
4 Cable terminations and internal connections – Fixed and free connectors
4.1 General
A connector may include multiple terminations between the cable termination and the
separable contact interface. These may include press in connections of jack springs into
PCBs, for example. All terminations shall meet the relevant termination requirements given in
4.2.
If a type of solderless termination is used which is not covered by any IEC specification, the
supplier shall assure its reliability by performing similar tests, and demonstrating similar level
of performance, to those in IEC 60352.
Free connectors are intended to be terminated to cable to provide connector and cable
assemblies. The connector type designation provides basic terminations concerning the type
of conductor (tinsel, stranded, solid) to which the conductor may be applied, and the type of
connection used (solder, insulation displacement, etc.). Specific details concerning wire
gauge size, type and thickness of conductor insulation, size and shape of cordage or cable
jacket, etc., are not intended to be part of this specification. Minor variations in a free
connector’s interior details to accommodate differing wire gauge sizes, outer jackets, etc., do
not require the generation of new free connector specifications.
If the connector is able to be used with multiple cable types, the manufacturer shall assure
that all connection points comply with the relevant IEC standards with each of the cable types.
4.
...