IEC 62020-1:2020/COR1:2020
(Corrigendum)Corrigendum 1 - Electrical accessories - Residual current monitors (RCMs) - Part 1: RCMs for household and similar uses
Corrigendum 1 - Electrical accessories - Residual current monitors (RCMs) - Part 1: RCMs for household and similar uses
Corrigendum 1 - Petit appareillage électrique - Contrôleurs d'isolement à courant différentiel résiduel (RCM) pour usages domestiques et analogues
General Information
- Status
- Published
- Publication Date
- 09-Jul-2020
- Technical Committee
- SC 23E - Circuit-breakers and similar equipment for household use
- Drafting Committee
- WG 2 - TC 23/SC 23E/WG 2
- Current Stage
- PPUB - Publication issued
- Start Date
- 10-Jul-2020
- Completion Date
- 21-Aug-2020
Relations
- Effective Date
- 05-Sep-2023
Get Certified
Connect with accredited certification bodies for this standard

Intertek Testing Services NA Inc.
Intertek certification services in North America.

UL Solutions
Global safety science company with testing, inspection and certification.

ANCE
Mexican certification and testing association.
Sponsored listings
Frequently Asked Questions
IEC 62020-1:2020/COR1:2020 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Corrigendum 1 - Electrical accessories - Residual current monitors (RCMs) - Part 1: RCMs for household and similar uses". This standard covers: Corrigendum 1 - Electrical accessories - Residual current monitors (RCMs) - Part 1: RCMs for household and similar uses
Corrigendum 1 - Electrical accessories - Residual current monitors (RCMs) - Part 1: RCMs for household and similar uses
IEC 62020-1:2020/COR1:2020 is classified under the following ICS (International Classification for Standards) categories: 29.120.50 - Fuses and other overcurrent protection devices. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 62020-1:2020/COR1:2020 has the following relationships with other standards: It is inter standard links to IEC 62020-1:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 62020-1:2020/COR1:2020 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 2020
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 62020-1 IEC 62020-1
Edition 1.0 2020-04 Édition 1.0 2020-04
ELECTRICAL ACCESSORIES – PETIT APPAREILLAGE ÉLECTRIQUE –
RESIDUAL CURRENT MONITORS (RCMs) – CONTRÔLEURS D'ISOLEMENT À COURANT
DIFFÉRENTIEL RÉSIDUEL (RCM) –
Part 1: RCMs for household and similar uses
Partie 1: RCM pour usages domestiques et
analogues
CO RRI G E NDUM 1
Corrections to the French version appear after the English text.
Les corrections à la version française sont données après le texte anglais.
8.18.2 Immunity requirements
Replace, in 8.18.2, the reference to Table 21 with Table 22, as follows:
Immunity requirements for RCMs are given in Table 22.
Table 22 – EMC tests
Replace, in row 7 of Table 22, "Covered by test of 9.11." with "Covered by tests of 9.11.", as
follows:
IEC 62020-1:2020-04/COR1:2020-07(en-fr)
– 2 – IEC 62020-1:2020/COR1:2020
IEC 2020
Performance
Phenomenon Basic standard Port Test value Specification
criteria
Electrostatic IEC 61000-4-2 Enclosure ±6 kV contact A2
discharges discharge
±8 kV air discharge A2
80 MHz to 1 GHz, A1
10 V/m for I ≥
Δn
Radiated radio- 30 mA
A1
frequency 80 MHz to 1 GHz,
IEC 61000-4-3 Enclosure
electromagnetic 3 V/m for I <
Δn
fields
A1
30 mA
1 GHz to 6 GHz,
3 V/m
Monitored
circuit ports
4 kV (5 kHz or A2
(U )
em
100 kHz)
Electrical fast
Auxiliary
4 kV (5 kHz or
A2
transients / IEC 61000-4-4
ports ≥
100 kHz)
bursts
100 V
2 kV (5 kHz or A2
Auxiliary
100 kHz)
ports <
100 V
Monitored 2 kV line to line (2 Ω) A2
circuit ports 4 kV line to earth B
(U ) (12 Ω)
em
2 kV line to line (2 Ω) A2
Auxiliary
4 kV line to earth A2
ports ≥
Surges IEC 61000-4-5
(12 Ω)
100 V
1 kV line to line A2
Not intended for
Auxiliary
a
(42 Ω) symmetrical operated
ports <
A2
2 kV line to earth circuits/lines
100 V >
(42 Ω)
10 m
150 kHz to 80 MHz A1
Conducted
10 V for I ≥ 30 mA
disturbances
Δn
IEC 61000-4-6 all ports
A1
induced by RF 150 kHz to 80 MHz
fields 3 V for I < 30 mA
Δn
Covered by tests of 9.11.
For RCMs with external
current transformers, the
Power
short-circuit tests shall be
frequency Enclosure
performed with the current
magnetic fields
transformer as close as
possible to the RCM,
according to manufacturer
instruction
0 % during A2
1 cycle
Voltage dips, For example,
40 % during B
short "25/30 cycles" means
IEC 61000-4-11 10/12 cycles
interruptions "25 cycles for 50 Hz test"
IEC 61000-4-34 70 % during B
and voltage or "30 cycles for 60 Hz
25/30 cycles
variations test"
0 % during B
250/300 cycles
Covered by test 9.17.
200 A for
I > 10 mA
Only in Quiescent mode,
Ring waves
Δn
without residual current,
25 A
...