IEC 61076-3-106:2006
(Main)Connectors for electronic equipment - Product requirements - Part 3-106: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface
Connectors for electronic equipment - Product requirements - Part 3-106: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface
Covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in the IEC 60603-7 series to IP65 and IP67 ratings according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms and a variety of different mounting configurations and termination types which are detailed in the IEC 60603-7 series.
Connecteurs pour équipements électroniques - Exigences de produit - Partie 3-106: Connecteurs rectangulaires - Spécification particulière pour boîtiers de protection utilisés avec des connecteurs blindés et non blindés 8 voies pour des environnements industriels incorporant l'interface série CEI 60603-7
Couvre les boîtiers de protection pour améliorer les connecteurs 8 voies blindés et non blindés existants utilisant l'interface décrite dans la série CEI 60603-7 pour les caractéristiques IP65 et IP67 conformément à la CEI 60529, utilisée dans les environnements industriels. Les boîtiers couvrent une variété de différents mécanismes de verrouillage conformément à la présente partie de la CEI 61076 et une variété de différentes configurations de montage et types de sortie qui sont détaillés dans la série CEI 60603-7.
General Information
- Status
- Published
- Publication Date
- 11-Sep-2006
- Technical Committee
- SC 48B - Electrical connectors
- Current Stage
- DELPUB - Deleted Publication
- Start Date
- 19-Jul-2023
- Completion Date
- 04-Jan-2019
Relations
- Effective Date
- 05-Sep-2023
Overview
IEC 61076-3-106:2006 is an international standard issued by the International Electrotechnical Commission (IEC) that specifies detailed requirements for protective housings used with 8-way shielded and unshielded rectangular connectors. These connectors incorporate the IEC 60603-7 series interface and are designed specifically for demanding industrial environments. The standard outlines product requirements that ensure robust protection, including IP65 and IP67 ingress protection ratings in accordance with IEC 60529, making the connectors suitable for harsh conditions such as dust, moisture, and mechanical stress.
This standard supports upgrading existing 8-way connectors by integrating protective housings that offer enhanced durability and environmental sealing. It addresses a broad range of locking mechanisms, mounting configurations, and termination types to facilitate diverse industrial applications.
Key Topics
Protective Housings for 8-Way Connectors
Specification for housings that enhance the durability and environmental protection of connectors, suitable for industrial use.Interface Compliance
Ensures compatibility with the IEC 60603-7 series interface, a recognized standard for rectangular connectors.Ingress Protection Ratings (IP65 and IP67)
Defines the protective requirements against dust ingress (IP65) and temporary immersion in water (IP67), critical for reliability in challenging environments.Locking Mechanism Variants
Details ten types of coupling methods including bayonet, snap-in, threaded ring, locking lever, quarter turn, and pulse lock mechanisms, providing flexibility in assembly and secure connection.Mounting and Termination Configurations
Covers various mounting options for fixed connectors, including detailed dimensional and mounting information for each variant to support standardized installation.Mechanical, Electrical, and Climatic Characteristics
Specifies testing procedures for mechanical strength, electrical performance, and environmental resistance ensuring high-quality and standardized connector performance.Testing and Quality Assurance
Includes a comprehensive program of tests covering contact resistance, dynamic stress, climatic and mechanical endurance, ensuring compliance and reliability.
Applications
IEC 61076-3-106:2006 is essential for manufacturers and engineers designing electronic equipment connectors for industrial environments such as:
Automation and Control Systems
Ensuring secure and durable connections for sensors, actuators, and control devices exposed to dust, water, and mechanical strain.Robotics and Machinery
Reliable connector housings fit for machines operating under vibration, moisture, or harsh ambient conditions.Industrial Communication Interfaces
Standardized connectors used in industrial data transmission, requiring shielded and unshielded options for noise immunity.Outdoor and Harsh Environment Electronics
Devices deployed in outdoor or factory settings where IP-rated protection prevents downtime and equipment failure.Upgrade and Retrofit Projects
Enhancing legacy 8-way connectors with protective housings to meet modern environmental protection requirements without full system replacement.
Related Standards
IEC 60603-7 Series
Defines the rectangular connector interface that IEC 61076-3-106 protective housings are designed to accommodate.IEC 60529
Specifies the classification and testing of ingress protection ratings, including IP65 and IP67 ratings referenced for environmental sealing.IEC 61076 Series
Broader connector product requirements covering rectangular connectors beyond the 8-way configuration.Other Industrial Connector Standards
Including relevant IEC and ISO standards focused on connector performance in electromagnetic compatibility (EMC), mechanical ruggedness, and environmental resistance.
By adhering to IEC 61076-3-106:2006, industries benefit from a standardized approach to enhancing connector protection and reliability, ensuring optimal performance in rigorous industrial applications. This standard is a key resource for design engineers, quality managers, and procurement specialists focusing on industrial connector solutions with proven environmental protection and operational robustness.
IEC 61076-3-106:2006 - Connectors for electronic equipment - Product requirements - Part 3-106: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface
Frequently Asked Questions
IEC 61076-3-106:2006 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Connectors for electronic equipment - Product requirements - Part 3-106: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface". This standard covers: Covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in the IEC 60603-7 series to IP65 and IP67 ratings according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms and a variety of different mounting configurations and termination types which are detailed in the IEC 60603-7 series.
Covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in the IEC 60603-7 series to IP65 and IP67 ratings according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms and a variety of different mounting configurations and termination types which are detailed in the IEC 60603-7 series.
IEC 61076-3-106:2006 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61076-3-106:2006 has the following relationships with other standards: It is inter standard links to IEC 61076-3-106:2023. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase IEC 61076-3-106:2006 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of IEC standards.
Standards Content (Sample)
NORME CEI
INTERNATIONALE
IEC
61076-3-106
INTERNATIONAL
Première édition
STANDARD
First edition
2006-09
Connecteurs pour équipements électroniques –
Exigences de produit –
Partie 3-106:
Connecteurs rectangulaires – Spécification
particulière pour boîtiers de protection utilisés
avec des connecteurs blindés et non blindés 8
voies pour des environnements industriels
incorporant l’interface série CEI 60603-7
Connectors for electronic equipment –
Product requirements –
Part 3-106:
Rectangular connectors – Detail specification for
protective housings for use with 8-way shielded
and unshielded connectors for industrial
environments incorporating the IEC 60603-7
series interface
Numéro de référence
Reference number
CEI/IEC 61076-3-106:2006
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE
IEC
61076-3-106
INTERNATIONAL
Première édition
STANDARD
First edition
2006-09
Connecteurs pour équipements électroniques –
Exigences de produit –
Partie 3-106:
Connecteurs rectangulaires – Spécification
particulière pour boîtiers de protection utilisés
avec des connecteurs blindés et non blindés 8
voies pour des environnements industriels
incorporant l’interface série CEI 60603-7
Connectors for electronic equipment –
Product requirements –
Part 3-106:
Rectangular connectors – Detail specification for
protective housings for use with 8-way shielded
and unshielded connectors for industrial
environments incorporating the IEC 60603-7
series interface
IEC 2006 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
X
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61076-3-106 CEI:2006
SOMMAIRE
AVANT-PROPOS.8
1 Données générales .12
1.1 Domaine d'application .12
1.2 Références normatives.12
1.3 Désignation de type CEI.16
2 Terminologie .16
3 Informations relatives aux dimensions .18
3.1 Caractéristiques communes .18
3.2 Généralités.18
3.3 Arrangement des contacts de tous les types de connecteurs.18
3.4 Etanchéité IP65 et IP67.18
3.5 Accouplement à baïonnette – variante 01 CEI 60603-7 industriel .18
3.6 Accouplement enfichable – variante 02 CEI 60603-7 industriel.24
3.7 Accouplement par bague filetée – variante 03 CEI 60603-7 industriel.32
3.8 Accouplement enfichable – variante 04 CEI 60603-7 industriel.36
3.9 Accouplement à levier de blocage – variante 05 CEI 60603-7 industriel .40
3.10 Accouplement enfichable – variante 06 CEI 60603-7 industriel.44
3.11 Accouplement à levier de blocage – variante 07 CEI 60603-7 industriel .48
3.12 Accouplement par bague filetée – variante 08 CEI 60603-7 industriel.52
3.13 Accouplement quart de tour – variante 09 CEI 60603-7 industriel.56
3.14 Accouplement à verrouillage par impulsion – variante 10 CEI 60603-7
industriel .60
3.15 Informations concernant la sortie et le montage .62
3.16 Informations concernant le montage pour la variante 01, embase.64
3.17 Informations concernant le montage pour la variante 02, embase.66
3.18 Informations concernant le montage pour la variante 03, embase.68
3.19 Informations concernant le montage pour la variante 04, embase.68
3.20 Informations concernant le montage pour la variante 05, embase.70
3.21 Informations concernant le montage pour la variante 06, embase.72
3.22 Informations concernant le montage pour la variante 07, embase.74
3.23 Informations concernant le montage pour la variante 08, embase.76
3.24 Informations concernant le montage pour la variante 09, embase.76
3.25 Informations concernant le montage pour la variante 10, embase.78
4 Calibres – Connecteurs pour l’interface CEI 60603-7.78
5 Caractéristiques .78
5.1 Catégorie climatique.78
5.2 Caractéristiques électriques .80
5.3 Caractéristiques de transmission.84
5.4 Caractéristiques mécaniques.84
6 Programme d’essais .84
6.1 Généralités.84
6.2 Procédures d’essai et méthodes de mesure .86
6.3 Préconditionnement.86
6.4 Câblage et montage des spécimens .86
61076-3-106 IEC:2006 – 3 –
CONTENTS
FOREWORD.9
1 General data .13
1.1 Scope.13
1.2 Normative references .13
1.3 IEC type designation .17
2 Terminology .17
3 Dimensional information .19
3.1 Common features .19
3.2 General .19
3.3 Contact arrangement of all connector types.19
3.4 IP65 and IP67 sealing .19
3.5 Industrial IEC 60603-7 variant 01 – bayonet coupling .19
3.6 Industrial IEC 60603-7 variant 02 – snap-in coupling .25
3.7 Industrial IEC 60603-7 variant 03 – threaded coupling.33
3.8 Industrial IEC 60603-7 variant 04 – snap-in coupling .37
3.9 Industrial IEC 60603-7 variant 05 – locking lever coupling.41
3.10 Industrial IEC 60603-7 variant 06 – snap-in coupling .45
3.11 Industrial IEC 60603-7 variant 07 – locking lever coupling.49
3.12 Industrial IEC 60603-7 variant 08 – threaded coupling.53
3.13 Industrial IEC 60603-7 variant 09 – quarter turn coupling .57
3.14 Industrial IEC 60603-7, variant 10 – Pulse lock coupling .61
3.15 Termination and mounting information.63
3.16 Mounting information for variant 01, fixed connector.65
3.17 Mounting information for variant 02, fixed connector.67
3.18 Mounting information for variant 03, fixed connector.69
3.19 Mounting information for variant 04, fixed connector.69
3.20 Mounting information for variant 05, fixed connector.71
3.21 Mounting information for variant 06, fixed connector.73
3.22 Mounting information for variant 07, fixed connector.75
3.23 Mounting information for variant 08, fixed connector.77
3.24 Mounting information for variant 09, fixed connector.77
3.25 Mounting information for variant 10, fixed connector.79
4 Gauges – Connectors for the IEC 60603-7 interface .79
5 Characteristics .79
5.1 Climatic category.79
5.2 Electrical .81
5.3 Transmission characteristics .85
5.4 Mechanical.85
6 Test schedule.85
6.1 General .85
6.2 Test procedures and measuring methods .87
6.3 Preconditioning .87
6.4 Wiring and mounting of specimens .87
– 4 – 61076-3-106 CEI:2006
6.5 Disposition pour l’essai de la résistance de contact.86
6.6 Dispositif pour les essais de contrainte dynamique (phase d'essai AP2).86
6.7 Programme d’essais de base (minimal) .86
6.8 Programme d’essais complet.86
Figure 1 – Embase, Variante 01.20
Figure 2 – Fiche, Variante 01.22
Figure 3 – Embase, Variante 02.24
Figure 4 – Fiche, Variante 02.28
Figure 5 – Embase, Variante 03.32
Figure 6 – Fiche, Variante 03.34
Figure 7 – Embase, Variante 04.36
Figure 8 – Fiche, Variante 04.38
Figure 9 – Embase, Variante 05.40
Figure 10 – Fiche, Variante 05.42
Figure 11 – Embase, Variante 06.44
Figure 12 – Fiche, Variante 06.46
Figure 13 – Embase, Variante 07.48
Figure 14 – Fiche, Variante 07.50
Figure 15 – Embase, Variante 08.52
Figure 16 – Fiche, Variante 08.54
Figure 17 – Embase, Variante 09.56
Figure 18 – Fiche, Variante 09.58
Figure 19 – Embase, Variante 10.60
Figure 20 – Fiche, Variante 10.62
Figure 21 – Variante 01, schéma de montage modèle 1.64
Figure 22 – Variante 01, schéma de montage modèle 2.64
Figure 23 – Schéma de montage de la variante 02 .66
Figure 24 – Schéma de montage de la variante 03 .68
Figure 25 – Schéma de montage de la variante 04 .68
Figure 26 – Schéma de montage de la variante 05 .70
Figure 27 – Schéma de montage de la variante 06 .72
Figure 28 – Schéma de montage de la variante 07 .74
Figure 29 – Schéma de montage de la variante 08 .76
Figure 30 – Schéma de montage de la variante 09 .76
Figure 31 – Schéma de montage de la variante 10 .78
Figure 32 – Courbe de réduction du connecteur.82
Tableau 1 – Dimensions d’embase variante 01 .20
Tableau 2 – Dimensions de fiche variante 01.22
Tableau 3 – Dimensions de variante 02 d’embase .26
Tableau 4 – Dimensions de variante 02 de fiche .30
Tableau 5 – Dimensions d’embase variante 03 .32
Tableau 6 – Dimensions de fiche variante 03.34
61076-3-106 IEC:2006 – 5 –
6.5 Arrangement for contact resistance test: .87
6.6 Arrangement for dynamic stress tests (test phase AP2).87
6.7 Basic (minimum) test schedule .87
6.8 Full test schedule .87
Figure 1 – Variant 01, fixed connector .21
Figure 2 – Variant 01, free connector.23
Figure 3 – Variant 02, fixed connector .25
Figure 4 – Variant 02, free connector.29
Figure 5 – Variant 03, fixed connector .33
Figure 6 – Variant 03, free connector.35
Figure 7 – Variant 04, fixed connector .37
Figure 8 – Variant 04, free connector.39
Figure 9 – Variant 05, fixed connector .41
Figure 10 – Variant 05, free connector .43
Figure 11 – Variant 06, fixed connector.45
Figure 12 – Variant 06, free connector .47
Figure 13 – Variant 07, fixed connector.49
Figure 14 – Variant 07, free connector .51
Figure 15 – Variant 08, fixed connector.53
Figure 16 – Variant 08, free connector .55
Figure 17 – Variant 09, fixed connector.57
Figure 18 – Variant 09, free connector .59
Figure 19 – Variant 10, fixed connector.61
Figure 20 – Variant 10, free connector .63
Figure 21 – Variant 01, style 1 mounting drawing.65
Figure 22 – Variant 01, style 2 mounting drawing.65
Figure 23 – Variant 02 mounting drawing .67
Figure 24 – Variant 03 mounting drawing .69
Figure 25 – Variant 04 mounting drawing .69
Figure 26 – Variant 05 mounting drawing .71
Figure 27 – Variant 06 mounting drawing .73
Figure 28 – Variant 07 mounting drawing .75
Figure 29 – Variant 08 mounting drawing .77
Figure 30 – Variant 09 mounting drawing .77
Figure 31 – Variant 10, mounting drawing.79
Figure 32 – Connector derating curve .83
Table 1 – Dimensions fixed connector variant 01 .21
Table 2 – Dimensions free connector variant 01.23
Table 3 – Dimensions fixed connector variant 02 .27
Table 4 – Dimensions free connector variant 02.31
Table 5 – Dimension fixed connector variant 03 .33
Table 6 – Dimensions free connector variant 03.35
– 6 – 61076-3-106 CEI:2006
Tableau 7 – Dimensions d’embase variante 04 .36
Tableau 8 – Dimensions de fiche variante 04.38
Tableau 9 – Dimensions d’embase variante 05 .40
Tableau 10 – Dimensions de fiche variante 05 .42
Tableau 11 – Dimensions d’embase variante 06 .44
Tableau 12 – Dimensions de fiche variante 06 .46
Tableau 13 – Dimensions d'embase variante 07 .48
Tableau 14 – Dimensions de fiche variante 07 .50
Tableau 15 – Dimensions d'embase variante 08 .52
Tableau 16 – Dimensions de fiche variante 08 .54
Tableau 17 – Dimensions d'embase variante 09 .56
Tableau 18 – Dimensions de fiche variante 09 .58
Tableau 19 – Dimensions d’embase variante 10 .60
Tableau 20 – Dimensions de fiche variante 10 .62
Tableau 21 – Variante 01, informations sur le montage modèle 1 .64
Tableau 22 – Variante 01, informations sur le montage modèle 2 .66
Tableau 23 – Informations sur le montage de la variante 02 .66
Tableau 24 – Informations sur le montage de la variante 03 .68
Tableau 25 – Informations sur le montage de la variante 04 .68
Tableau 26 – Informations sur le montage de la variante 05 .70
Tableau 27 – Informations sur le montage de la variante 06 .72
Tableau 28 – Informations sur le montage de la variante 07 .74
Tableau 29 – Informations sur le montage de la variante 08 .76
Tableau 30 – Informations sur le montage de la variante 09 .76
Tableau 31 – Informations sur le montage de la variante 10 .78
Tableau 32 – Catégories climatiques – valeurs choisies pour le niveau A de
performance environnementale.78
Tableau 33 – Lignes de fuite et distances d’isolement .80
Tableau 34 – Groupe d’essais P .88
Tableau 35 – Groupe d’essais AP – Essais dynamiques/climatiques.90
Tableau 36 – Groupe d’essais BP – Mécaniques .94
Tableau 37 – Groupe d’essais CP – Continuité .96
61076-3-106 IEC:2006 – 7 –
Table 7 – Dimensions fixed connector variant 04 .37
Table 8 – Dimensions free connector variant 04.39
Table 9 – Dimensions fixed connector variant 05 .41
Table 10 – Dimensions free connector variant 05.43
Table 11 – Dimensions fixed connector variant 06 .45
Table 12 – Dimensions free connector variant 06.47
Table 13 – Dimensions fixed connector variant 07 .49
Table 14 – Dimensions free connector variant 07.51
Table 15 – Dimensions fixed connector variant 08 .53
Table 16 – Dimensions free connector variant 08.55
Table 17 – Dimensions fixed connector variant 09 .57
Table 18 – Dimensions free connector variant 09.59
Table 19 – Dimensions fixed connector variant 10 .61
Table 20 – Dimensions free connector variant 10.63
Table 21 – Variant 01, style 1 mounting information.65
Table 22 – Variant 01, style 2 mounting information.67
Table 23 – Variant 02 mounting information .67
Table 24 – Variant 03 mounting information .69
Table 25 – Variant 04 mounting information .69
Table 26 – Variant 05 mounting information .71
Table 27 – Variant 06 mounting information .73
Table 28 – Variant 07 mounting Information.75
Table 29 – Variant 08 mounting information .77
Table 30 – Variant 09 mounting information .77
Table 31 – Variant 10 mounting information .79
Table 32 – Climatic categories – selected values for environmental performance level A .79
Table 33 – Creepage and clearance .81
Table 34 – Test group P .89
Table 35 – Test group AP – Dynamic/climatic .91
Table 36 – Test Group BP – Mechanical .95
Table 37 – Test group CP – Continuity.97
– 8 – 61076-3-106 CEI:2006
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
___________
CONNECTEURS POUR ÉQUIPEMENTS ÉLECTRONIQUES –
EXIGENCES DE PRODUIT –
Partie 3-106: Connecteurs rectangulaires – Spécification particulière pour
boîtiers de protection utilisés avec des connecteurs blindés
et non blindés 8 voies pour des environnements industriels
incorporant l’interface série CEI 60603-7
AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes
internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au
public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des
comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent
également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les publications CEI se présentent sous la forme de recommandations internationales et elles sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable
de l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toute divergence entre toute Publication de la CEI et toute publication nationale ou
régionale correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n’engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
La Commission Électrotechnique Internationale (CEI) attire l'attention sur le fait que l'on demande que la
conformité à cette norme internationale puisse entraîner l'utilisation d'un ou plusieurs brevets concernant les fiches
de 3.5, 3.6.2, 3.10.2, 3.11, 3.11.2, 3.12.2, 3.13.2 et 3.14.2.
La CEI ne prend pas position concernant la preuve, la validité et le domaine d'application de ces droits de
propriété.
Le détenteur de ce droit de propriété (voir 3.5) a assuré à la CEI qu'il est prêt à donner des licences gratuites aux
demandeurs dans le monde entier. À ce sujet, la déclaration du détenteur du droit de propriété industrielle est
enregistrée auprès de la CEI.
Des informations peuvent être obtenues auprès de:
La Société Siemon
27 Siemon Company Drive
Watertown, CT 06795-0400
USA
61076-3-106 IEC:2006 – 9 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 3-106: Rectangular connectors – Detail specification for protective
housings for use with 8-way shielded and unshielded connectors for
industrial environments incorporating the IEC 60603-7 series interface
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
The International Electrotechnical Commission (IEC) draws attention to the fact that it is claimed that compliance
with this International Standard may involve the use of patent(s) concerning the free connectors in 3.5, 3.6.2,
3.10.2, 3.11, 3.11.2, 3.12.2, 3.13.2 and 3.14.2.
The IEC takes no position concerning the evidence, validity and scope of these patent rights.
The holder of this patent right (Subclause 3.5).has assured the IEC that he/she is willing to give free licences with
applicants throughout the world. In this respect, the statement of the holder of this patent right is registered with
the IEC.
Information may be obtained from:
The Siemon Company
27 Siemon Company Drive
Watertown, CT 06795-0400
USA
– 10 – 61076-3-106 CEI:2006
Le détenteur de ce droit de propriété (voir 3.6.2, 3.10.2, 3.11.2, 3.12.2, 3.13.2, 3.14.2) a assuré à la CEI qu'il est
prêt à négocier des licences en des termes et conditions raisonnables et non discriminatoires, avec les
demandeurs à travers le monde. À ce sujet, la déclaration du détenteur du droit de propriété est enregistrée auprès
de la CEI.
Des informations peuvent être obtenues auprès de:
La Société Siemon
27 Siemon Company Drive
Watertown, CT 06795-0400
USA
Le détenteur de ce droit de propriété (voir 3.11) a assuré à la CEI qu'il est prêt à négocier des licences en des
termes et conditions raisonnables et non discriminatoires, avec les demandeurs à travers le monde. À ce sujet, la
déclaration du détenteur du droit de propriété est enregistrée auprès de la CEI.
Des informations peuvent être obtenues concernant la variante de 3.11 auprès de:
Harting Electric GmbH & Co KG
Postfach 1473
32328 Espelkamp
Allemagne
L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire l’objet
de droits de propriété industrielle distincts de ceux identifiés ci-dessus. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété ou de ne pas avoir signalé leur existence.
La Norme internationale CEI 61076 a été établie par le sous-comité 48B: Connecteurs, du
comité d’études 48: Composants électromécaniques et structures mécaniques pour
équipements électroniques.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
48B/1692A/FDIS 48B/1711/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 2.
Une liste de toutes les parties de la série CEI 61076, présentées sous le titre général
Connecteurs pour équipements électroni
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...