Abstract

Describes the principles, the terminology, the characteristics, the requirements and the testing methods related to instrumentation and measurement of the neutron fluence rate using mean square voltage techniques for nuclear reactor control.

Status
Published
Publication Date
09-Nov-1998
Current Stage
PPUB - Publication issued - 60 Publication
Start Date
10-Nov-1998
Due Date
31-Dec-1998
Completion Date
31-Dec-1998

Buy Documents

Standard

IEC 61501:1998 - Nuclear reactor instrumentation - Wide range neutron fluence rate meter - Mean square voltage method Released:11/10/1998

ISBN:2-8318-4571-8
English and French language (79 pages)
sale 15% off
Preview
sale 15% off
Preview

Overview

IEC 61501:1998 is an international standard established by the International Electrotechnical Commission (IEC) that addresses instrumentation and measurement techniques for controlling nuclear reactors. Specifically, it focuses on wide range neutron fluence rate meters using the mean square voltage method. This standard details the principles, terminology, characteristics, requirements, and testing methods relevant to neutron fluence rate measurement, an essential component in nuclear reactor instrumentation for safe and efficient reactor control.

By standardizing the methods using mean square voltage techniques, IEC 61501:1998 ensures consistency and reliability in neutron detection instrumentation across nuclear power plants and research facilities worldwide. This enables precise monitoring of neutron flux over a wide dynamic range, critical for maintaining optimal reactor performance and safety.

Key Topics

  • Scope and Definitions
    The standard defines crucial terminology and abbreviations related to neutron fluence rate measurement instrumentation, ensuring a clear understanding among engineers and technicians.

  • Mean Square Voltage Method
    The document elaborates on the principle of the mean square voltage technique for measuring neutron fluence. This method processes electrical pulses generated by neutron detection to determine neutron flux accurately, even at high count rates where pulse overlapping occurs.

  • Implementation Techniques
    IEC 61501 outlines three main implementation methodologies:

    • Linear analogue measurement using quadratic amplifiers
    • Logarithmic analogue measurement via logarithmic amplifiers
    • Digital computation of variance through numerical processing
  • Wide Range Channel Structures
    The standard describes device architectures suitable for wide dynamic range measurements, such as single-detector and dual-detector wide range channels, enabling reliable neutron flux monitoring from low to very high intensities.

  • Equipment Characteristics and Test Methods
    It specifies attributes and test procedures for critical components including preamplifiers, quadratic amplifiers, logarithmic amplifiers, summing amplifiers, and digital mean square processors. This ensures each device meets stringent performance and reliability criteria.

  • Test Conditions and Environmental Requirements
    The standard defines testing environments and generator equipment needed to validate the operating conditions of neutron fluence rate meters.

  • Informative Annex on Applications
    Annex A provides additional insights into practical applications of wide range channels within nuclear reactor control systems.

Applications

IEC 61501:1998 neutron fluence rate meters based on the mean square voltage method are primarily used in:

  • Nuclear Reactor Control Systems
    Ensuring continuous, accurate monitoring of neutron flux to maintain reactor criticality and safety margins.

  • Safety Instrumentation
    Detecting abnormal reactor conditions promptly by monitoring neutron intensity changes over wide dynamic ranges.

  • Research Reactors and Neutron Sources
    Facilitating precise neutron flux measurements in experimental setups for nuclear physics and materials testing.

  • Nuclear Power Plant Instrumentation
    Integrating with digital control systems to provide reliable input for automated reactor protection and operational optimization.

This standard supports the development and deployment of instrumentation that can handle both low and extremely high neutron flux rates without loss of accuracy-a vital factor in modern nuclear technology.

Related Standards

For comprehensive understanding and implementation, IEC 61501 should be used in conjunction with related IEC standards including:

  • IEC 60050 - International Electrotechnical Vocabulary (IEV), for definitions of electrical and electronic terminology.
  • IEC 60027 - Letter symbols to be used in electrical technology.
  • IEC 60417 - Graphical symbols for use on equipment.
  • IEC 60617 - Graphical symbols for diagrams in electrical schematics.
  • Other Nuclear Instrumentation Standards by IEC Technical Committee 45 - Covering broader aspects of nuclear instrumentation and measurement techniques.

Using these interconnected IEC standards ensures uniform terminology, symbols, and methodologies across nuclear instrumentation systems, supporting interoperability and safety compliance globally.


By adhering to IEC 61501:1998, nuclear facilities can implement reliable wide range neutron fluence rate meters, leveraging the mean square voltage method to achieve precise, reproducible neutron flux measurements essential for reactor instrumentation and safety management. This standard forms a foundational reference for engineers, designers, and safety professionals in the nuclear industry worldwide.

Buy Documents

Standard

IEC 61501:1998 - Nuclear reactor instrumentation - Wide range neutron fluence rate meter - Mean square voltage method Released:11/10/1998

ISBN:2-8318-4571-8
English and French language (79 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

DNV

DNV is an independent assurance and risk management provider.

NA Norway Verified

Lloyd's Register

Lloyd's Register is a global professional services organisation specialising in engineering and technology.

UKAS United Kingdom Verified

DNV Energy Systems

Energy and renewable energy certification.

NA Norway Verified

Sponsored listings

Frequently Asked Questions

IEC 61501:1998 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Nuclear reactor instrumentation - Wide range neutron fluence rate meter - Mean square voltage method". This standard covers: Describes the principles, the terminology, the characteristics, the requirements and the testing methods related to instrumentation and measurement of the neutron fluence rate using mean square voltage techniques for nuclear reactor control.

Describes the principles, the terminology, the characteristics, the requirements and the testing methods related to instrumentation and measurement of the neutron fluence rate using mean square voltage techniques for nuclear reactor control.

IEC 61501:1998 is classified under the following ICS (International Classification for Standards) categories: 27.120.20 - Nuclear power plants. Safety. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 61501:1998 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


NORME
CEI
INTERNATIONALE
IEC
INTERNATIONAL
Première édition
STANDARD
First edition
1998-11
Instrumentation des réacteurs nucléaires –
Appareillage de mesure du débit de fluence
neutronique à grande dynamique –
Méthode du carré de la tension moyenne
Nuclear reactor instrumentation –
Wide range neutron fluence rate meter –
Mean square voltage method
Numéro de référence
Reference number
CEI / IEC 61501:1998
Numéros des publications Numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60 000. issued with a designation in the 60 000 series.
Publications consolidées Consolidated publications
Les versions consolidées de certaines publications de Consolidated versions of some IEC publications
la CEI incorporant les amendements sont disponibles. including amendments are available. For example,
Par exemple, les numéros d’édition 1.0, 1.1 et 1.2 edition numbers 1.0, 1.1 and 1.2 refer, respectively, to
indiquent respectivement la publication de base, la the base publication, the base publication incor-
publication de base incorporant l’amendement 1, et porating amendment 1 and the base publication
la publication de base incorporant les amendements 1 incorporating amendments 1 and 2.
et 2.
Validité de la présente publication Validity of this publication
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept under
constamment revu par la CEI afin qu'il reflète l'état constant review by the IEC, thus ensuring that the
actuel de la technique. content reflects current technology.
Des renseignements relatifs à la date de re- Information relating to the date of the reconfirmation of
confirmation de la publication sont disponibles dans the publication is available in the IEC catalogue.
le Catalogue de la CEI.
Les renseignements relatifs à des questions à l’étude et Information on the subjects under consideration and
des travaux en cours entrepris par le comité technique work in progress undertaken by the technical com-
qui a établi cette publication, ainsi que la liste des mittee which has prepared this publication, as well as
publications établies, se trouvent dans les documents the list of publications issued, is to be found at the
ci-dessous: following IEC sources:
• «Site web» de la CEI* • IEC web site*
• Catalogue des publications de la CEI • Catalogue of IEC publications
Publié annuellement et mis à jour régulièrement Published yearly with regular updates
(Catalogue en ligne)* (On-line catalogue)*
• Bulletin de la CEI • IEC Bulletin
Disponible à la fois au «site web» de la CEI* Available both at the IEC web site* and
et comme périodique imprimé as a printed periodical
Terminologie, symboles graphiques Terminology, graphical and letter
et littéraux symbols
En ce qui concerne la terminologie générale, le lecteur For general terminology, readers are referred to
se reportera à la CEI 60050: Vocabulaire Electro- IEC 60 050: International Electrotechnical Vocabulary
technique International (VEI). (IEV).
Pour les symboles graphiques, les symboles littéraux For graphical symbols, and letter symbols and signs
et les signes d'usage général approuvés par la CEI, le approved by the IEC for general use, readers are
lecteur consultera la CEI 60027: Symboles littéraux à referred to publications IEC 60027: Letter symbols to
utiliser en électrotechnique, la CEI 60417: Symboles be used in electrical technology, IEC 60417: Graphical
graphiques utilisables sur le matériel. Index, relevé et symbols for use on equipment. Index, survey and
compilation des feuilles individuelles, et la CEI 60617: compilation of the single sheets and IEC 60617:
Symboles graphiques pour schémas. Graphical symbols for diagrams.
* Voir adresse «site web» sur la page de titre. * See web site address on title page.

NORME
CEI
INTERNATIONALE
IEC
INTERNATIONAL
Première édition
STANDARD
First edition
1998-11
Instrumentation des réacteurs nucléaires –
Appareillage de mesure du débit de fluence
neutronique à grande dynamique –
Méthode du carré de la tension moyenne
Nuclear reactor instrumentation –
Wide range neutron fluence rate meter –
Mean square voltage method
 IEC 1998 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun any form or by any means, electronic or mechanical,
procédé, électronique ou mécanique, y compris la photo- including photocopying and microfilm, without permission in
copie et les microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
PRICE CODE W
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 61501 © CEI:1998
SOMMAIRE
Pages
AVANT-PROPOS . 4
INTRODUCTION . 6
Articles
1 Domaine d’application. 8
2 Références normatives. 8
3 Définitions. 10
4 Abréviations. 12
5 Principe de la méthode du carré de la tension moyenne. 12
6 Mise en oeuvre de la méthode du carré de la tension moyenne. 14
6.1 Mesure analogique linéaire: amplificateur quadratique. 14
6.2 Mesure analogique logarithmique: amplificateur logarithmique. 16
6.3 Calcul direct de la variance par traitement numérique. 16
7 Structure d'une chaîne à grande dynamique . 18
7.1 Chaîne à grande dynamique à un seul détecteur . 20
7.2 Chaîne à grande dynamique à deux détecteurs . 22
8 Technologie des chaînes à grande dynamique. 22
8.1 Chaîne à grande dynamique analogique . 24
8.2 Chaîne à grande dynamique numérique. 24
9 Conditions d’essai et générateurs d’essai . 26
9.1 Conditions environnementales pour les essais. 26
9.2 Equipements d’essai. 26
10 Caractéristiques et méthodes d’essai des préamplificateurs. 28
10.1 Caractéristiques des préamplificateurs . 28
10.2 Méthodes d’essai des préamplificateurs . 30
11 Caractéristiques et méthodes d’essai des amplificateurs quadratiques. 38
11.1 Caractéristiques des amplificateurs quadratiques . 38
11.2 Méthodes d’essai des amplificateurs quadratiques . 38
12 Caractéristiques et méthodes d’essai des amplificateurs logarithmiques . 50
12.1 Caractéristiques des amplificateurs logarithmiques. 50
12.2 Méthodes d’essai des amplificateurs logarithmiques. 50
13 Caractéristiques et méthodes d’essai des amplificateurs sommateurs
de signaux logarithmiques . 60
13.1 Caractéristiques des amplificateurs sommateurs . 60
13.2 Méthodes d’essai des amplificateurs sommateurs . 64
14 Caractéristiques et méthodes d’essai des processeurs numériques
de fluctuations (PNF) . 68
14.1 Caractéristiques des processeurs numériques de fluctuations . 68
14.2 Méthodes d’essai des processeurs numériques de fluctuations. 70
Annexe A (informative) Applications des chaînes à grande dynamique . 74
Bibliographie .78

61501 © IEC:1998 – 3 –
CONTENTS
Page
FOREWORD . 5
INTRODUCTION . 7
Clause
1 Scope. 9
2 Normative references. 9
3 Definitions. 11
4 Abbreviations. 13
5 Principle of the mean square voltage method. 13
6 Implementation of the mean square voltage method . 15
6.1 Linear analogue method: quadratic amplifier. 15
6.2 Logarithmic analogue method: logarithmic amplifier. 17
6.3 Digital method: digital mean square processor. 17
7 Structure of a wide range channel . 19
7.1 Single-detector WRC. 21
7.2 Double-detector WRC. 23
8 Technology of WRC . 23
8.1 Analogue wide range channel. 25
8.2 Digital wide range channel. 25
9 Test conditions and test generators . 27
9.1 Environmental test conditions. 27
9.2 Test equipment. 27
10 Characteristics and test methods for preamplifiers. 29
10.1 Characteristics of the preamplifier . 29
10.2 Test methods for the preamplifier . 31
11 Characteristics and test methods for quadratic amplifiers . 39
11.1 Characteristics of the quadratic amplifier . 39
11.2 Test methods for the quadratic amplifier. 39
12 Characteristics and test methods for logarithmic amplifiers . 51
12.1 Characteristics of the logarithmic amplifier . 51
12.2 Test methods for the logarithmic amplifier . 51
13 Characteristics and test methods for logarithmic summing amplifiers . 61
13.1 Characteristics of the summing amplifier . 61
13.2 Test methods for the summing amplifier . 65
14 Characteristics and test methods for digital mean square processors (DMSP). 69
14.1 Characteristics of the digital mean square processor . 69
14.2 Test methods for the DMSP . 71
Annex A (informative) Applications of WCRs. 75
Bibliography .79

– 4 – 61501 © CEI:1998
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
_________
INSTRUMENTATION DES RÉACTEURS NUCLÉAIRES –
APPAREILLAGE DE MESURE DU DÉBIT DE FLUENCE NEUTRONIQUE
À GRANDE DYNAMIQUE –
MÉTHODE DU CARRÉ DE LA TENSION MOYENNE
AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, rapports techniques ou guides et agréés comme tels par les Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 61501 a été établie par le sous-comité 45A: Instrumentation des
réacteurs, du comité d’études 45 de la CEI: Instrumentation nucléaire.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
45A/338/FDIS 45A/346/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
L’annexe A est donnée uniquement à titre d’information.

61501 © IEC:1998 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
_________
NUCLEAR REACTOR INSTRUMENTATION –
WIDE RANGE NEUTRON FLUENCE RATE METER –
MEAN SQUARE VOLTAGE METHOD
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
This International Standard IEC 61501 has been prepared by subcommittee 45A: Reactor
instrumentation, of IEC technical committee 45: Nuclear instrumentation.
The text of this standard is based on the following documents:
FDIS Report on voting
45A/338/FDIS 45A/346/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
Annex A is for information only.

– 6 – 61501 © CEI:1998
INTRODUCTION
La réponse d'une chambre à fission à un neutron consiste à produire une impulsion de charges
électriques et, grâce au comptage de ces impulsions, il est possible de mesurer le débit de
fluence neutronique. Pour des niveaux de flux plus élevés, le taux de production des
impulsions augmente jusqu'à produire une superposition des impulsions (un phénomène connu
sous le terme «empilement des impulsions») et le procédé de comptage des impulsions
devient impossible.
Une autre approche pour le traitement consiste à considérer l'empilement des impulsions
comme un signal courant continu fluctuant. En utilisant la théorie de Campbell, on peut montrer
que le carré moyen de l'amplitude du signal, mesuré sur une largeur de bande donnée, est
proportionnel au taux de comptage initial. Pour les valeurs inférieures du débit de fluence
3 4
neutronique, le traitement est limité à des valeurs de l'ordre de 10 à 10 fissions par seconde
à cause du bruit de fond de l'électronique et de la chambre elle-même. Pour les valeurs
10 11
supérieures, la limite est environ de 10 à 10 fissions par seconde à cause des non-
linéarités provoquées par les phénomènes de charge d'espace. Il s'agit de la principale
application de la méthode du carré de la tension moyenne.
L'utilisation de la technique de mesure du carré de la tension moyenne (CTM), en association
avec la technique de comptage des impulsions, permet de concevoir un système capable de
mesurer le débit de fluence neutronique sur une dynamique de plus de 11 décades avec une
chambre à fission en utilisant une méthode adéquate de correction. Il est aussi possible
d'utiliser deux détecteurs différents.

61501 © IEC:1998 – 7 –
INTRODUCTION
The response of a fission chamber to a neutron is to produce a pulse of electrical charge and
by counting these pulses it is possible to measure the neutron fluence rate. At higher levels the
rate of pulse generation increases to the point where pulses merge (a phenomenon known as
"pulse pile-up") and the process of electronically counting the pulses becomes impracticable.
An alternative approach to processing is to consider the piled-up pulses as a fluctuating d.c.
signal. Using Campbell's theory it can be shown that the mean square of the signal amplitude,
measured over a fixed bandwidth, is proportional to the initial pulse rate. At low fluence rate
3 4
levels the use of this approach is limited to 10 to 10 fissions per second by background noise
in the electronics and in the fission chamber. The limit at high fluence rate levels is in the

10 11
range 10 to 10 fissions per second because of non linearity caused by space charge
effects. This is the most common application of the MSV method.
The use of the mean square voltage (MSV) measurement technique in combination with pulse
counting permits the design of a system capable of measuring a neutron fluence rate over a
range of more than 11 decades using a single fission chamber with appropriate corrections. It
is also possible to use two different detectors.

– 8 – 61501 © CEI:1998
INSTRUMENTATION DES RÉACTEURS NUCLÉAIRES –
APPAREILLAGE DE MESURE DU DÉBIT DE FLUENCE NEUTRONIQUE
À GRANDE DYNAMIQUE –
MÉTHODE DU CARRÉ DE LA TENSION MOYENNE
1 Domaine d’application
La présente Norme internationale s'applique aux appareils et chaînes de mesure qui mettent
en oeuvre le calcul du carré de la tension moyenne d'un signal issu d'un détecteur neutronique
pour en extraire une information relative au niveau de flux d'un réacteur nucléaire. Après
calibration, cette information peut être utilisée pour en déduire la puissance relative et la
constante de temps exprimée par exemple en termes de période, de temps de doublement, de
décades par minute ou «pour-cent par seconde».
La méthode du calcul du carré de la tension moyenne du signal est également connue sous les
termes de «traitement des fluctuations» ou «méthode de Campbell».
Associée à d'autres techniques de mesure, comme le comptage d'impulsions ou la mesure du
courant, la méthode du calcul du carré de la tension moyenne permet de constituer une chaîne
de mesure neutronique à grande dynamique dont l'intérêt réside dans la simplification des
systèmes d'instrumentation nucléaire pour le contrôle des réacteurs nucléaires.
Cette norme décrit les principes, la terminologie, les caractéristiques, les exigences et les
méthodes d’essai relatifs au fonctionnement des appareils et chaînes de mesure utilisant le
carré de la tension moyenne d'un signal.
Des exemples typiques d'applications sont donnés.
2 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence
qui y est faite, constituent des dispositions valables pour la présente Norme internationale. Au
moment de la publication, les éditions indiquées étaient en vigueur. Tout document normatif
est sujet à révision, et les parties prenantes aux accords fondés sur la présente Norme
internationale sont invitées à rechercher la possibilité d'appliquer les éditions les plus récentes
des documents normatifs indiqués ci-après. Les membres de la CEI et de l'ISO possèdent le
registre des Normes internationales en vigueur.
CEI 60050(101):1998, Vocabulaire électrotechnique international (VEI) – Partie 101: Mathé-
matiques
CEI 60050(393):1996, Vocabulaire électrotechnique international (VEI) – Chapitre 393:
Instrumentation nucléaire: Phénomènes physiques et notions fondamentales
CEI 60050(394):1995, Vocabulaire électrotechnique international (VEI) – Chapitre 394:
Instrumentation nucléaire: Instruments
CEI 60359:1987, Expression des qualités de fonctionnement des équipements de mesure
électriques et électroniques
CEI 60527:1975, Amplificateurs pour courant continu; caractéristiques et méthodes d’essais
CEI 60650:1979, Ictomètres analogiques – Caractéristiques et méthodes d’essai
CEI 60880:1986, Logiciel pour les calculateurs utilisés dans les systèmes de sûreté des
centrales nucléaires
61501 © IEC:1998 – 9 –
NUCLEAR REACTOR INSTRUMENTATION –
WIDE RANGE NEUTRON FLUENCE RATE METER –
MEAN SQUARE VOLTAGE METHOD
1 Scope
This International Standard applies to instrument and measurement channels which generate a
calculation of the mean square voltage (MSV) of a signal arising from a neutron detector, in
order to extract from it information relating to the neutron fluence rate of a nuclear reactor.
After calibration, this information can be used to derive the relative power and the time
constant, for example expressed in terms of period, doubling time, decades per minute or
percent per second.
The method used to calculate the mean square voltage of the signal is also known as
"fluctuation treatment" or "the Campbell method".
Associated with other techniques of measurement, such as pulse rate counting or current
measurement, the calculation of the mean square voltage allows the assembly of a series of
wide range neutron fluence rate measurements for the simplification of nuclear instrumentation
systems in the control of nuclear reactors.
This standard describes the principles, the terminology, the characteristics, the requirements
and the testing methods related to instrumentation and measurement of the neutron fluence
rate using MSV techniques for nuclear reactor control.
Typical examples of the application of the MSV techniques are given.
2 Normative references
The following normative documents contain provisions which, through reference in this text,
constitute provisions of this International Standard. At the time of publication, the editions
indicated were valid. All normative documents are subject to revision, and parties to
agreements based on this International Standard are encouraged to investigate the possibility
of applying the most recent editions of the normative documents indicated below. Members of
IEC and ISO maintain registers of currently valid International Standards.
IEC 60050(101):1998, International Electrotechnical Vocabulary (IEV) – Part 101: Mathematics
IEC 60050(393):1996, International Electrotechnical Vocabulary (IEV) – Chapter 393: Nuclear
instrumentation: Physical phenomena and basic concepts
IEC 60050(394):1995, International Electrotechnical Vocabulary (IEV) – Chapter 394: Nuclear
instrumentation: Instruments
IEC 60359:1987, Expression of the performance of electrical and electronic measuring
equipment
IEC 60527:1975, Direct current amplifiers; characteristics and test methods
IEC 60650:1979, Analogue counting ratemeters – Characteristics and test methods
IEC 60880:1986, Software for computers in the safety systems of nuclear power stations

– 10 – 61501 © CEI:1998
3 Définitions
Pour les besoins de la présente Norme internationale, les définitions données dans la CEI
60050(101), la CEI 60050(393), ainsi que la CEI 60050(394), ainsi que les définitions suivantes
s’appliquent.
NOTE – Le principe de la méthode est basé sur l'analyse des variations du signal de sortie d'un détecteur et d'une
chaîne d'amplification. Ces variations ont de nombreuses origines. Les impulsions induites par les réactions de
détection et les perturbations internes ou externes à la chaîne de mesure. Pour clarifier le document, les termes qui
caractérisent l'origine du signal sont définis. Généralement le terme «bruit» s'applique aux variations du signal
induites par des perturbations.
3.1
fluctuations
variations aléatoires d'une grandeur physique autour de sa valeur moyenne
NOTE – Dans cette norme, le terme «fluctuations» désigne les variations du signal induites par les phénomènes
d'ionisation dans le détecteur. Ces variations sont produites par le rayonnement gamma ou par l'émission alpha du
dépôt sensible ou par les réactions induites par les neutrons dans le dépôt. Pour les applications de mesure, seules
les fluctuations des réactions neutroniques sont utiles.
3.2
bruit électronique
variations du signal produites par l'agitation thermique des composants des circuits élec-
troniques. Il s'agit d'une perturbation interne à la chaîne de mesure.
3.3
bruit du système
toutes les variations du signal dont l'origine est extérieure à la chaîne de mesure
3.4
bruit blanc
processus aléatoire dont la densité spectrale de puissance est constante et indépendante de la
fréquence
3.5
processus poissonien
processus défini à partir des trois hypothèses suivantes:
– le nombre d'événements survenant dans un intervalle de temps T est indépendant du
temps et indépendant de ceux déjà survenus;
– la probabilité d'avoir un événement et un seul dans un intervalle de temps T est
proportionnelle à T lorsque T → 0;
– la probabilité d'avoir plus d'un événement dans un intervalle de temps T tend vers zéro plus
vite que T lorsque T → 0.
La loi de probabilité P est:
K
()aT
−aT
P(,KT)=×
e
K!
où
K est le nombre d'événements considérés;
T est l’intervalle de temps considéré;
a est le nombre moyen d'événements.
Il intervient dans toutes les réactions nucléaires de fission.

61501 © IEC:1998 – 11 –
3 Definitions
For the purpose of this International Standard, the definitions given in IEC 60050(101),
IEC 60050(393) and 60050(394), as well as the following apply.
NOTE – The principle of the method is based on the variations analysis of the output of a detector and amplifier
channel. These variations have many origins: the pulses induced by the reactions of detection and the perturbations
internal or external to the channel. To ensure clarity in the document, the terms which characterize the origin of the
signal are defined. Generally the term "noise" refers to the signal variations linked to the perturbations.
3.1
fluctuations
random variations of a physical quantity around its mean value
NOTE – In this standard, “fluctuations” means the variations of the measured signal induced by ionizing phenomena
inside the detector. These variations are produced by the gamma radiation, by the alpha emission of the sensitive
coating or by the neutron reactions induced in the coating. For the considered applications only, the fluctuations
from neutron reactions are useful.
3.2
electronic noise
variation of a signal produced by the thermal agitation of the components of the electronic
circuits. It is an internal perturbation of the measuring channel.
3.3
system noise
all variations of the signal with an origin external to the measuring channel
3.4
white noise
random process whereby the power density spectrum is constant and independent of the
frequency
3.5
Poisson process
process defined according to the three following hypotheses:
– the number of events noted in a time interval T is independent of time and independent of
any events which have already occurred;
– the probability of having one event, and one only, in a time interval T is proportional to T
when T → 0;
– the probability of having more than one event in a time interval T tends towards 0 faster
than T when T → 0.
The law of probability P is:
K
()aT
−aT
P(,KT)=×
e
K!
where
K is the number of considered events;
T is the time interval considered;
a is the mean number of events.
It occurs in all nuclear fission reactions.

– 12 – 61501 © CEI:1998
3.6
signal pseudo-aléatoire
signal déterministe périodique ayant des propriétés spectrales très voisines de celles des
processus poissoniens. Le signal pseudo-aléatoire fournit un spectre de raies dont l'enveloppe
des amplitudes est constante dans une certaine bande de fréquence. (Le signal aléatoire
poissonien conduit à un spectre continu.)
3.7
méthode des taux de comptage
méthode de traitement du signal qui s'applique à des impulsions séparées. L'information utile
représentative du débit de fluence neutronique est contenue dans le nombre d'impulsions par
unité de temps (taux de comptage).
3.8
méthode du carré de la tension moyenne
méthode de traitement du signal qui s'applique à un signal aléatoire. L'information utile
représentative du débit de fluence neutronique est contenue dans le carré de la valeur
moyenne de l'amplitude du signal alternatif provenant du détecteur.
NOTE – Cette méthode et son application à la mesure du débit de fluence neutronique sont présentées dans cette norme.
3.9
chaîne à grande dynamique
ensemble de détection utilisant en même temps plusieurs techniques de mesure comme la
mesure du taux de comptage, la mesure du courant continu ou la méthode du carré de la tension
moyenne
4 Abréviations
cps coups par seconde
PNF processeur numérique de fluctuations
DPM décades par minute
CEM compatibilité électromagnétique
PN puissance nominale
PPS pour-cent par seconde
LOCA accident avec perte de réfrigérant primaire (loss of coolant accident)
CTM carré de la tension moyenne
–2 –1
nv unité de débit de fluence neutronique. Notation pour neutron × cm × s
OPM octaves par minute
valeur efficace (abrégé en anglais seulement)
S/I source/intermédiaire
CGD chaîne à grande dynamique
5 Principe de la méthode du carré de la tension moyenne
Le principe de la méthode du carré de la tension moyenne consiste à traiter le signal issu d'un
détecteur pour estimer la tension moyenne induite par la fluctuation. Cette tension est
proportionnelle à la racine carrée du débit de fluence neutronique. Pour ce type de mesure,
un détecteur de neutrons du type chambre à fission est utilisé. Un tel détecteur est constitué
d'une ou plusieurs électrodes avec un dépôt fissile, polarisées pour collecter les charges.
Typiquement deux électrodes définissent un volume sensible rempli avec un gaz inerte,
partiellement ionisé par les alphas, les gammas et les produits de fission.

61501 © IEC:1998 – 13 –
3.6
pseudo-random signal
periodic deterministic signal with spectral properties similar to those of Poisson processes. The
pseudo-random signal provides a constant amplitude envelope at discrete frequencies within a
certain frequency band. (The Poisson random signal tends to give a continuous spectrum.)
3.7
counting rate method
signal processing method which applies to a signal having the form of separate pulses. The
useful information representative of the neutron fluence rate is contained in the number of
pulses per each unit of time (counting rate).
3.8
mean square voltage method
signal processing method which applies to a random signal. The information representative of
the neutron fluence rate is contained in the mean square value of the a.c. part of the detector
signal.
NOTE – This method and its application for neutron fluence rate measurement are presented in this standard.
3.9
wide range channel
detection assembly using at the same time several measurement techniques such as counting
rate, d.c. measurement, mean square voltage method
4 Abbreviations
cps counts per second
DMSP digital mean square processor
DPM decades per minute
EMC electromagnetic compatibility
FP full power
PPS percent per second
LOCA loss of coolant accident
MSV mean square voltage
–2 –1
nv neutron fluence rate unit. Notation for neutron × cm × s
OPM octaves per minute
r.m.s. root mean square
S/I source/intermediate
WRC wide range channel
5 Principle of the mean square voltage method
The principle of the mean square voltage method is to process the signal coming from a
neutron detector to estimate the mean voltage induced by the fluctuation. This voltage is
proportional to the square root of the neutron fluence rate. For this type of measurement, a
neutron detector, in the form of a fission chamber is used. Such a detector consists of one or
more polarized electrodes for charge collection, on which the fissile material is deposited.
Typically two electrodes determine a sensitive volume filled by an inert gas, partially ionized by
alpha, gamma and fission products.

– 14 – 61501 © CEI:1998
L'application de la théorie de Campbell, dans le cas d'un amplificateur passe-bande recevant à
l'entrée une charge Q (émise à chaque fission se produisant dans le détecteur) et en
supposant que la fréquence basse de coupure de l'amplificateur est égale à zéro, donne
l'expression suivante:
R
2 2
= N× × = N×××π× f
σ Q Q R
c
S
2C
où
est la variance du signal;
σ
S
est le taux de comptage moyen;
N
Q est la moyenne du carré de la charge développée à chaque événement;

R est la résistance de contre-réaction;
C est la capacité de contre-réaction;
est la fréquence de coupure du filtre.
f
c
La variance est proportionnelle à N et aussi à B, qui représente la largeur de bande.
Dans ce cas:
B==
f
c
2××π RC
NOTE – Le signal de sortie de l'amplificateur est une tension fluctuante. Du fait du caractère ergodique du signal,
(identité entre les moyennes statistiques et les moyennes temporelles), l'écart type et la valeur efficace de cette
tension peuvent être confondus.
6 Mise en oeuvre de la méthode du carré de la tension moyenne
Les méthodes utilisées pour déduire le débit de fluence neutronique par le traitement des
fluctuations peuvent être classées en trois catégories, décrites en 6.1, 6.2 et 6.3.
6.1 Mesure analogique linéaire: amplificateur quadratique
Il s'agit d'un circuit de mesure constitué d'un amplificateur à bande étroite, qui délivre une
tension efficace V dont l'amplitude est proportionnelle à N , et d'un circuit quadrateur suivi
d'un filtre, qui délivre une tension de sortie (V ) proportionnelle à N.
s
61501 © IEC:1998 – 15 –
Application of the theory of Campbell, in the case of a band-pass filter amplifier receiving at its
input the charge Q (emitted during each fission within the detector) and taking the low cut-off
frequency of the amplifier as zero, leads to the expression:
R
= × × = ×××π×
N N f
σ Q Q R
c
S
2C
where
is the variance of the signal;
σ
S
N is the mean counting rate;
is the average of the square of the charge released during each event;
Q
R is the feedback resistance;
is the feedback capacitor;
C
f is the cut-off frequency of the filter.
c
The variance is proportional to N and also to B, the width of the pass band.
In that case:
B==
f
c
2××π RC
NOTE – The output signal of the amplifier is a fluctuating voltage. Due to the ergodic character of the signal,
(similarity between statistical average and time average), the standard deviation and the r.m.s. of the voltage are
equivalent.
6 Implementation of the mean square voltage method
The method used to derive the neutron fluence rate can be divided into three main categories
as described in 6.1, 6.2 and 6.3.
6.1 Linear analogue method: quadratic amplifier
This concerns a measurement circuit consisting of a narrowband preamplifier which gives an
r.m.s. voltage V for which the amplitude is proportional to N , and a squaring circuit followed
by a filter, making available an output signal (V ) proportional to N.
out
– 16 – 61501 © CEI:1998
Ci-dessous est représenté un exemple de schéma de principe de cette méthode.
C
R
Amplificateur
Câble coaxial
Filtre
X
Détecteur
Amplificateur quadratique
(chambre à fission)
Préamplificateur
V = K × N
s
V = K N
+ HT
IEC  1 548/98
Figure 1 – Diagramme schématique d'une chaîne de mesure linéaire
Le filtre devant l'opérateur d'élévation au carré donne une meilleure amplification entre les
impulsions.
6.2 Mesure analogique logarithmique: amplificateur logarithmique
Comme pour la mesure analogique linéaire, le circuit de mesure est constitué d'un
amplificateur à bande étroite suivi d'un amplificateur logarithmique qui délivre une tension de
sortie proportionnelle au logarithme du débit de fluence neutronique et donc au logarithme de
la puissance du réacteur. Ci-dessous est représenté un schéma de principe de cette méthode.
C
R
Câble coaxial V = K × log N
s
Amplificateur
X
log.
Détecteur
(chambre à fission)
Préamplificateur
d/dt
Taux de variation
IEC  1 549/98
+ HT
Figure 2 – Diagramme schématique d'une chaîne de mesure logarithmique
6.3 Calcul direct de la variance par traitement numérique
Le circuit de mesure est constitué d'un amplificateur à bande étroite suivi d'un échantillonneur
rapide et d'un circuit de calcul de la variance du signal. Ce dispositif est couplé à une unité
centrale qui exploite la mesure du flux pour en déduire la puissance du réacteur. Dans le cas
où ce dispositif est mis en oeuvre dans une chaîne de sûreté, le logiciel doit être développé
conformément aux recommandations de la CEI 60880.

61501 © IEC:1998 – 17 –
Below is a block diagram of this method, as an example.
C
R
Amplifier
Coaxial cable
Filter X
Detector
Quadratic amplifier
(fission counter)
Preamplifier
V = K × N
out
V = K N
+ HV
IEC  1 548/98
Figure 1 – Schematic diagram of the linear analogue method
The filter placed before the squaring operator permits a better build-up between pulses.
6.2 Logarithmic analogue method: logarithmic amplifier
Similarly to the linear analogue method, the measuring circuit consists of a narrowband
amplifier whose output is sent to a logarithmic amplifier. The output is proportional to the
logarithm of the neutron fluence rate and hence to the logarithm of the reactor power. A block
diagram of this method is shown below as an example:
C
R
Coaxial cable
V = K × log N
out
X
Log. amplifier
Detector
(fission counter)
Preamplifier
d/dt
Rate of change
IEC  1 549/98
+ HV
Figure 2 – Schematic diagram of the logarithmic method
6.3 Digital method: digital mean square processor
The measurement circuit consists of a narrowband amplifier followed by a fast sampling circuit
and a mean square processor which directly calculates the variance of the signal. This device
is coupled with a central processing unit which operates on the digitally derived fluence rate
measurement in order to deduce the power of the reactor. When implemented in a safety
channel, the software shall be developed according to the recommendations of IEC 60880.

– 18 – 61501 © CEI:1998
Un exemple de schéma de cette méthode est donné ci-après.
C
R
Vers l'unité centrale
Câble coaxial
Echantillonneur et calcul
Filtre
de la variance
Détecteur
(chambre à fission)
Préamplificateur
Processeur numérique
IEC  1 550/98
+ HT
Figure 3 – Diagramme schématique d'une chaîne de mesure linéaire
7 Structure d'une chaîne à grande dynamique
Pour obtenir une chaîne à grande dynamique, on combine des circuits de comptage et de
mesure du carré de la tension moyenne. Conformément aux exigences fonctionnelles, la
combinaison peut comprendre un détecteur unique ou un double détecteur. Dans le deuxième
cas, les éléments sensibles peuvent être indépendants ou réunis dans le même assemblage.
Une chaîne à grande dynamique est généralement constituée de deux types de circuits
électroniques:
– les circuits de conditionnement, qui comprennent le préamplificateur, l'amplificateur et
l'alimentation haute tension. Les circuits de conditionnement produisent des signaux de
haut niveau nécessaires au traitement fonctionnel;
– les circuits de traitement, qui comprennent le traitement fonctionnel proprement dit comme
le calcul du taux de comptage, la comparaison aux seuils
...