IEC 62841-2-9:2015/COR1:2015
(Corrigendum)Corrigendum 1 - Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery - Safety - Part 2-9: Particular requirements for hand-held tappers and threaders
Corrigendum 1 - Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery - Safety - Part 2-9: Particular requirements for hand-held tappers and threaders
Corrigendum 1 - Outils électroportatifs à moteur, outils portables et machines pour jardins et pelouses - Sécurité - Partie 2-9: Exigences particulières pour les taraudeuses et les fileteuses portatives
General Information
Relations
Buy Standard
Standards Content (Sample)
IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 62841-2-9 IEC 62841-2-9
Edition 1.0 2015-01 Edition 1.0 2015-01
ELECTRIC MOTOR-OPERATED HAND-HELD OUTILS ELECTROPORTATIFS A MOTEUR,
TOOLS, TRANSPORTABLE TOOLS AND LAWN OUTILS PORTABLES ET MACHINES POUR
AND GARDEN MACHINERY – SAFETY – JARDINS ET PELOUSES – SECURITE –
Part 2-9: Particular requirements for hand-held Partie 2-9: Exigences particulières pour les
tappers and threaders taraudeuses et les fileteuses portatives
CO RRI G E NDUM 1
Corrections to the French version appear after the English text.
Les corrections à la version française sont données après le texte anglais.
18 Abnormal operation
Replace Table 4 with the following:
Table 4 – Required performance levels
Type and purpose of SCF Minimum performance level
(PL)
Power switch – prevent unwanted switch-on for tappers a
Power switch – prevent unwanted switch-on for threaders a
Power switch – provide desired switch-off for tappers b
Power switch – provide desired switch-off for threaders c
Provide desired direction of rotation Not an SCF
Any electronic control to pass the test of 18.3 Not an SCF
Any speed limiting device Not an SCF
Prevent exceeding thermal limits as in Clause 18 a
IEC 62841-2-9:2015-01/COR1:2015-10(en-fr)
– 2 – IEC 62841-2-9:2015/COR1:2015
IEC 2015
K.18 Abnormal operation
Replace Table 4 with the following:
Table 4 – Required performance levels
Type and purpose of SCF Minimum performance level
(PL)
Power switch – prevent unwanted switch-on for tappers a
Power switch – prevent unwanted switch-on for threaders a
Power switch – provide desired switch-off for tappers a
Power switch – provide desired switch-off for threaders c
Provide desired direction of rotation Not an SCF
A
...