IEC 62651:2013
(Main)Nuclear power plants - Instrumentation important to safety - Thermocouples: characteristics and test methods
- Abstract
IEC 62651:2013 describes the requirements for thermocouples suitable for nuclear power plant (NPP) applications. Thermocouples are widely used in NPPs with other temperature measurement devices such as resistance temperature detectors. They are simple and robust and have some specific characteristics (range of measurement and maximum temperature) which make them uniquely suitable for some measurements. The requirements given in this standard for thermocouples include design, materials, manufacturing, testing, calibration, procurement, and inspection.
- Status
- Published
- Publication Date
- 28-Apr-2013
- Technical Committee
- SC 45A - Instrumentation, control and electrical power systems of nuclear facilities
- Drafting Committee
- WG 2 - Sensors and measurement techniques
- Current Stage
- PPUB - Publication issued - 60 Publication
- Start Date
- 29-Apr-2013
- Due Date
- 15-May-2013
- Completion Date
- 15-May-2013
Overview
IEC 62651:2013 specifies the requirements and test methods for thermocouples used in nuclear power plants (NPPs) for instrumentation important to safety. Thermocouples are widely used for temperature measurements in NPPs alongside resistance temperature detectors (RTDs). Recognized for their simplicity, robustness, and ability to function over wide temperature ranges, thermocouples are vital for monitoring and control in nuclear environments. This IEC standard covers design, materials, manufacturing, testing, calibration, procurement, and inspection requirements, ensuring that thermocouples meet the stringent demands of nuclear safety and operational reliability.
Key Topics
- Types of Thermocouples for Nuclear Use
- The standard addresses commonly used thermocouple types in NPPs, such as Type K, N, and E, which offer robust performance under nuclear operating conditions.
- Design and Construction
- Requirements for the design and materials of thermocouple assemblies, including mineral-insulated designs and protection methods such as thermowells.
- Installation and Mounting
- Guidance on proper installation techniques (direct contact, direct immersion, use of thermowells) to ensure accurate and reliable temperature readings.
- Performance Criteria
- Key characteristics include measurement range, maximum temperature, accuracy, response time, and reliability.
- Testing and Calibration
- Details on test methods including performance testing, calibration, electrical insulation resistance, qualification tests (thermal shock, vibration, thermal cycling), and production tests.
- Procurement and Inspection
- Requirements ensure that all procured thermocouples meet the strict quality and performance standards essential for nuclear applications.
Applications
Thermocouples designed and tested according to IEC 62651:2013 are essential for:
- Reactor Core Monitoring
- Measuring fuel channel outlet temperature and core structural temperatures, supporting reactor protection and operational control.
- Primary Coolant Circuit
- Providing continuous temperature data critical for the safety and efficiency of primary cooling systems.
- In-core and Out-of-core Applications
- Used both for fixed installations and in portable probes for calibration and troubleshooting.
- Harsh Environments
- Mineral-insulated, robustly constructed assemblies ensure long-term performance in high-radiation, high-temperature, and chemically aggressive environments found in NPPs.
- Routine Maintenance and Safety Checks
- Support necessary performance monitoring and maintenance activities to assure continued compliance with nuclear safety regulations.
Related Standards
IEC 62651:2013 is part of a broader set of IEC standards for nuclear instrumentation, with strong interrelations, including:
- IEC 60584 series: Reference tables, tolerances, and extension/compensating cables for thermocouples.
- IEC 60737: Characteristics and test methods for temperature sensors in reactor and primary coolant circuit.
- IEC 60780: Qualification of electrical equipment of the safety system.
- IEC 61513: General requirements for instrumentation and control (I&C) systems in nuclear power plants.
- IEC 61515: Mineral-insulated thermocouple cables and thermocouples.
- Other relevant standards address seismic qualification (IEC 60980) and provide additional guidance on safety instrumented systems and quality assurance.
Adhering to IEC 62651:2013 helps ensure that thermocouples installed in nuclear power plants are fit for purpose, reliable, and compliant with international safety standards. This is crucial for plant operators, system designers, evaluators, and regulatory authorities focused on the effective monitoring and control of nuclear plant operations, with a clear emphasis on safety, quality, and long-term performance.
Get Certified
Connect with accredited certification bodies for this standard

DNV
DNV is an independent assurance and risk management provider.

Lloyd's Register
Lloyd's Register is a global professional services organisation specialising in engineering and technology.

DNV Energy Systems
Energy and renewable energy certification.
Sponsored listings
Frequently Asked Questions
IEC 62651:2013 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Nuclear power plants - Instrumentation important to safety - Thermocouples: characteristics and test methods". This standard covers: IEC 62651:2013 describes the requirements for thermocouples suitable for nuclear power plant (NPP) applications. Thermocouples are widely used in NPPs with other temperature measurement devices such as resistance temperature detectors. They are simple and robust and have some specific characteristics (range of measurement and maximum temperature) which make them uniquely suitable for some measurements. The requirements given in this standard for thermocouples include design, materials, manufacturing, testing, calibration, procurement, and inspection.
IEC 62651:2013 describes the requirements for thermocouples suitable for nuclear power plant (NPP) applications. Thermocouples are widely used in NPPs with other temperature measurement devices such as resistance temperature detectors. They are simple and robust and have some specific characteristics (range of measurement and maximum temperature) which make them uniquely suitable for some measurements. The requirements given in this standard for thermocouples include design, materials, manufacturing, testing, calibration, procurement, and inspection.
IEC 62651:2013 is classified under the following ICS (International Classification for Standards) categories: 27.120.20 - Nuclear power plants. Safety. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 62651:2013 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 62651 ®
Edition 1.0 2013-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Nuclear power plants – Instrumentation important to safety – Thermocouples:
characteristics and test methods
Centrales nucléaires de puissance – Instrumentation importante pour la sûreté –
Thermocouples: caractéristiques et méthodes d'essai
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les
microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
Useful links:
IEC publications search - www.iec.ch/searchpub Electropedia - www.electropedia.org
The advanced search enables you to find IEC publications The world's leading online dictionary of electronic and
by a variety of criteria (reference number, text, technical electrical terms containing more than 30 000 terms and
committee,…). definitions in English and French, with equivalent terms in
It also gives information on projects, replaced and additional languages. Also known as the International
withdrawn publications. Electrotechnical Vocabulary (IEV) on-line.
IEC Just Published - webstore.iec.ch/justpublished Customer Service Centre - webstore.iec.ch/csc
Stay up to date on all new IEC publications. Just Published If you wish to give us your feedback on this publication
details all new publications released. Available on-line and or need further assistance, please contact the
also once a month by email. Customer Service Centre: csc@iec.ch.
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
Liens utiles:
Recherche de publications CEI - www.iec.ch/searchpub Electropedia - www.electropedia.org
La recherche avancée vous permet de trouver des Le premier dictionnaire en ligne au monde de termes
publications CEI en utilisant différents critères (numéro de électroniques et électriques. Il contient plus de 30 000
référence, texte, comité d’études,…). termes et définitions en anglais et en français, ainsi que
Elle donne aussi des informations sur les projets et les les termes équivalents dans les langues additionnelles.
publications remplacées ou retirées. Egalement appelé Vocabulaire Electrotechnique
International (VEI) en ligne.
Just Published CEI - webstore.iec.ch/justpublished
Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications de la CEI.
Just Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur
Disponible en ligne et aussi une fois par mois par email. cette publication ou si vous avez des questions
contactez-nous: csc@iec.ch.
IEC 62651 ®
Edition 1.0 2013-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Nuclear power plants – Instrumentation important to safety – Thermocouples:
characteristics and test methods
Centrales nucléaires de puissance – Instrumentation importante pour la sûreté –
Thermocouples: caractéristiques et méthodes d'essai
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX V
ICS 27.120.20 ISBN 978-2-83220-754-3
– 2 – 62651 © IEC:2013
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 8
2 Normative references . 8
3 Terms and definitions . 8
4 List of abbreviations . 11
5 Principle of a thermocouple . 11
5.1 General . 11
5.2 Types of thermocouples for nuclear applications . 13
5.2.1 General . 13
5.2.2 Type K . 13
5.2.3 Type T . 13
5.2.4 Type J . 13
5.2.5 Type N . 13
5.2.6 Type E . 13
5.2.7 Type C . 13
5.2.8 Noble metal thermocouples (Type S,R,B) . 14
6 Technology of thermocouple assemblies . 14
6.1 Thermocouple assembly . 14
6.1.1 General . 14
6.1.2 Direct contact . 15
6.1.3 Direct immersion . 15
6.1.4 Thermowell mounted . 15
6.2 Performance . 15
6.2.1 Accuracy . 15
6.2.2 Range of measurement . 15
6.2.3 Response time. 15
6.2.4 Reliability . 15
6.3 Design and construction requirements . 16
6.3.1 General . 16
6.3.2 Reference junctions . 16
6.3.3 Construction principles . 16
6.3.4 Materials . 17
6.3.5 Insulation resistance (ungrounded thermocouple) . 18
6.3.6 Interchangeability – Replacement . 18
6.4 Installation of thermocouple assembly . 18
6.4.1 Installation requirements . 18
6.4.2 Installation in a thermowell . 19
6.4.3 Connections . 19
6.5 Operational features of thermocouples . 20
6.5.1 General considerations on the use of thermocouples . 20
6.5.2 Ambient conditions (normal and accident operations) . 21
6.5.3 Metallurgical inhomogeneities . 21
6.5.4 Corrosion. 21
6.5.5 Thermocouple stability . 21
6.5.6 Cold working phenomena . 22
62651 © IEC:2013 – 3 –
7 Tests . 22
7.1 General . 22
7.2 Performance tests and pre-production testing . 22
7.2.1 General . 22
7.2.2 Calibration . 23
7.2.3 Response time. 23
7.2.4 Electrical insulation resistance tests . 23
7.3 Qualification tests (type tests) . 23
7.3.1 General . 23
7.3.2 Repeatability (thermal shock) . 24
7.3.3 Vibration . 25
7.3.4 Steam test or high pressure hydraulic test . 25
7.3.5 Thermal cycling . 26
7.3.6 Harsh environmental conditions qualification . 26
7.4 Production tests . 26
7.4.1 Manufacturing factors . 26
7.4.2 Examination. 27
7.4.3 Identification . 28
8 Technical information required. 28
Bibliography . 30
Figure 1 – Schematic diagram of a thermocouple . 11
Figure 2 − Electrical structures of a thermocouple . 14
Figure 3 – Installation of a thermocouple in a thermowell . 19
Table 1 − List of thermocouples and their use in an NPP . 12
Table 2 – Example of vibration test requirements . 25
– 4 – 62651 © IEC:2013
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
NUCLEAR POWER PLANTS –
INSTRUMENTATION IMPORTANT TO SAFETY –
THERMOCOUPLES: CHARACTERISTICS AND TEST METHODS
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62651 has been prepared by subcommittee 45A: Instrumentation
and control of nuclear facilities, of IEC technical committee 45: Nuclear instrumentation.
The text of this standard is based on the following documents:
FDIS Report on voting
45A/904/FDIS 45A/920/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
62651 © IEC:2013 – 5 –
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 6 – 62651 © IEC:2013
INTRODUCTION
a) Technical background, main issues and organisation of the Standard
This IEC standard specifically focuses on thermocouple characteristics and test methods.It is
intended that the Standard be used by operators of NPPs (utilities), systems evaluators,
designers and by licensors.
b) Situation of the current Standard in the structure of the IEC SC 45A standard series
IEC 62651 is the third level SC 45A document tackling the generic issue of design and
qualification of thermocouples. It provides the technical background to the nature and use of
thermocouples. It provides information on the choice of thermocouple type in relation to the
nuclear power applications of concern. It describes the method of use of thermocouples in
nuclear reactors. It gives detailed type test and manufacturing test requirements.
IEC 62651 is to be read in association with IEC 60737 which is the appropriate IEC SC 45A
document which provides guidance on temperature sensors for reactor applications in
general, and with IEC 60780 for equipment qualification. Other IEC standards of general
application to thermocouples are given in the normative references of clause 2, and IAEA
documents and background information are referenced in the bibliography.
For more details on the structure of the IEC SC 45A standard series, see item d) of this
introduction.
c) Recommendations and limitations regarding the application of the Standard
It is important to note that this Standard establishes no additional functional requirements for
safety systems.
Aspects for which special recommendations have been provided in this Standard are:
• the types of thermocouple suitable for nuclear reactor applications;
• the normal mounting arrangements;
• the use of hot or cold reference junctions and of compensating cable;
• the mechanical and metallurgical aspects to be considered;
• the use and types of cold-end seals;
• installation;
• testing.
To ensure that the Standard will continue to be relevant in future years, the emphasis has
been placed on issues of principle, rather than specific technologies.
d) Description of the structure of the IEC SC 45A standard series and relationships
with other IEC documents and other bodies documents (IAEA, ISO)
The top-level document of the IEC SC 45A standard series is IEC 61513. It provides general
requirements for I&C systems and equipment that are used to perform functions important to
safety in NPPs. IEC 61513 structures the IEC SC 45A standard series.
IEC 61513 refers directly to other IEC SC 45A standards for general topics related to
categorization of functions and classification of systems, qualification, separation of systems,
defence against common cause failure, software aspects of computer-based systems,
hardware aspects of computer-based systems, and control room design. The standards
62651 © IEC:2013 – 7 –
referenced directly at this second level should be considered together with IEC 61513 as a
consistent document set.
At a third level, IEC SC 45A standards not directly referenced by IEC 61513 are standards
related to specific equipment, technical methods, or specific activities. Usually these
documents, which make reference to second-level documents for general topics, can be used
on their own.
A fourth level extending the IEC SC 45A standard series, corresponds to the Technical
Reports which are not normative.
IEC 61513 has adopted a presentation format similar to the basic safety publication
IEC 61508 with an overall safety life-cycle framework and a system life-cycle framework.
Regarding nuclear safety, it provides the interpretation of the general requirements of
IEC 61508-1, IEC 61508-2 and IEC 61508-4, for the nuclear application sector, regarding
nuclear safety. In this framework IEC 60880 and IEC 62138 correspond to IEC 61508-3 for
the nuclear application sector. IEC 61513 refers to ISO as well as to IAEA GS-R-3 and IAEA
GS-G-3.1 for topics related to quality assurance (QA).
The IEC SC 45A standards series consistently implements and details the principles and
basic safety aspects provided in the IAEA code on the safety of NPPs and in the IAEA safety
series, in particular the IAEA Safety Standard SSR 2/1, establishing safety requirements
related to the design of Nuclear Power Plants, and the Safety Guide NS-G-1.3 dealing with
instrumentation and control systems important to safety in Nuclear Power Plants. The
terminology and definitions used by SC 45A standards are consistent with those used by the
IAEA.
NOTE It is assumed that for the design of I&C systems in NPPs that implement conventional safety functions (e.g.
to address worker safety, asset protection, chemical hazards, process energy hazards) international or national
standards would be applied, that are based on the requirements of a Standard such as IEC 61508.
– 8 – 62651 © IEC:2013
NUCLEAR POWER PLANTS –
INSTRUMENTATION IMPORTANT TO SAFETY –
THERMOCOUPLES: CHARACTERISTICS AND TEST METHODS
1 Scope
This International Standard describes the requirements for thermocouples suitable for nuclear
power plant (NPP) applications. Thermocouples are widely used in NPPs with other
temperature measurement devices such as Resistance Temperature Detectors (RTDs). They
are simple and robust and have some specific characteristics (range of measurement and
maximum temperature) which make them uniquely suitable for some measurements.
The requirements given in this standard for thermocouples include design, materials,
manufacturing, testing, calibration, procurement, and inspection.
The scope of this standard does not cover the design, material selection, and construction of
the thermowell, the guide tube, the extension cable, and the temperature transmitter or bridge
which may be associated with the thermocouple.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60584-1:1995, Thermocouples – Part 1: Reference tables
IEC 60584-2:1982, Thermocouples – Part 2: Tolerances
Amendment 1:1989
IEC 60584-3:2007, Thermocouples – Part 3: Extension and compensating
cables − Tolerances and identification system
IEC 60737:2010, Nuclear power plants – Instrumentation important to safety – Temperature
sensors (in-core and primary coolant circuit) – Characteristics and test methods
IEC 60780, Nuclear power plants – Electrical equipment of the safety system – Qualification
IEC 60980, Recommended practices for seismic qualification of electrical equipment of the
safety system for nuclear generating stations
IEC 61513, Nuclear power plants − Instrumentation and control important to safety – General
requirements for systems
IEC 61515:1995, Mineral insulated thermocouple cables and thermocouples
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
62651 © IEC:2013 – 9 –
3.1
accuracy of measurement
closeness of the agreement between the result of a measurement and the conventionally true
value of the measurand
Note 1 to entry: "Accuracy" is a qualitative concept.
Note 2 to entry: The term precision should not be used for "accuracy".
[SOURCE: IEC 60050-394:2007, 394-40-35]
3.2
calibration
set of operations that establish, under specified conditions, the relationship between values of
quantities indicated by measuring instrument or measuring system, or values represented by
a material measure or a reference material, and the corresponding values realized by
standards
[SOURCE: IEC 60050-394:2007, 394-40-43]
3.3
reference junction
junction of the thermocouple which is at a known (reference) temperature to which the
measuring temperature is compared
Note 1 to entry: The reference junction is also called the cold junction.
[SOURCE: IEC 60584-1:1995, definition 2.4]
3.4
drift
variation in sensor or instrument channel output that may occur between calibrations that
cannot be related to changes in the process variable or environmental conditions
[SOURCE: IEC 62385:2007, definition 3.7]
3.5
measurement junction
the metal-to-metal junction of the thermocouple located where the temperature is measured.
The second junction is located at a reference temperature
Note 1 to entry: The measurement junction is also called the hot junction.
3.6
performance monitoring
process of demonstrating that an installed instrument channel continues to perform its
intended function of monitoring the process variable with the expected accuracy, response
time, and stability
[SOURCE: IEC 62385:2007, definition 3.13]
3.7
response time
the period of time necessary for a component to achieve a specified output state from the time
that it receives a signal requiring it to assume that output state
[SOURCE: IAEA Safety Glossary, edition 2007]
– 10 – 62651 © IEC:2013
3.8
extension and compensating cables
cables used for the electrical connection between the open ends of a thermocouple and the
reference junction in those installations where the conductors of the thermocouple are not
directly connected to the reference junction. The thermoelectric properties of extension and
compensating cables must be close to the properties of the corresponding thermocouple
[SOURCE: IEC 60584-3:2007, definition 3.1]
3.9
extension cables
cables manufactured from conductors having the same nominal composition as those of the
corresponding thermocouple. They are designated by the letter "X" following the designation
of the thermocouple, for example "JX"
[SOURCE: IEC 60584-3:2007, definition 3.1.1]
3.10
compensating cables
cables manufactured from conductors having a composition different from the corresponding
thermocouple. They are designated by the letter "C" following the designation of the
thermocouple, for example "KC". In some cases different tolerances apply for the same
thermocouple type over different temperature ranges. These are distinguished by additional
letters such as, for example, KCA and KCB
[SOURCE: IEC 60584-3:2007, definition 3.1.2]
3.11
thermocouple
pair of conductors of dissimilar materials joined at one end and forming part of an
arrangement using the thermoelectric effect for temperature measurement
[SOURCE: IEC 60584-2:1982, definition 2.2]
3.12
thermocouple assembly
an assembly used for temperature measurement, comprising a double set of junctions (hot
and cold junctions), cables, connections and an electronic system measuring very low
voltages
3.13
thermowell
protective jacket for RTDs, thermocouples and other temperature sensors. The thermowell is
also used to facilitate replacement of the temperature sensor
[SOURCE: IEC 62385:2007, definition 3.19]
3.14
time constant
in the case of a first order system, the time required for the output signal of a system to reach
63,2 % of its final variation after a step change of its input signal. If the system is not a first
order system, the term "time constant" is not appropriate. For a system of a higher order, the
term "response time" should be used
[SOURCE: IEC 62385:2007, definition 3.20]
62651 © IEC:2013 – 11 –
3.15
thermoelectric (Seebeck) effect
the thermoelectric effect is the production of an electromotive force EMF due to the difference
of temperature between two junctions of different metals or alloys forming part of the same
circuit
[SOURCE: IEC 60584-2, definition 2.1]
4 List of abbreviations
EMF Electromotive Force
HELB High Energy Line Break
LOCA Lost Of Coolant Accident
NPP Nuclear Power Plant
QA Quality Assurance
RTD Resistance Temperature Detector
5 Principle of a thermocouple
5.1 General
When two wires made from dissimilar metals are joined together (by welding or at terminals)
at both ends, a small voltage appears on the loop depending on the temperature difference
between the two ends as shown on Figure 1. This phenomenon is known as the Seebeck
effect. It is the basic principle of a thermocouple used for temperature measurement.
The metal forming one wire is electrically positive compared to the other.
Cold junction (reference)
Hot junction Metal A
+ +
Th Tc
– –
Metal B Metal B
EMF (voltage):
polynomial function of (Th – Tc)
Electronic system
IEC 802/13
Key
Th temperature of hot junction
Tc temperature of cold junction
Figure 1 – Schematic diagram of a thermocouple
The measuring end is called the hot junction and the other end at a reference temperature is
called the cold junction. An electronic system measures the voltage and converts it to give the
temperature by comparison with the reference temperature measured by another principle.
The relationship between the thermocouple EMF signal and the process temperature is a
– 12 – 62651 © IEC:2013
polynomial combination whose coefficients are given by Table 1 of IEC 60584-1:1995. The
typical voltage generated by type K thermocouple is about 40 µV/°C from a source with the
impedance of the loop resistance of the metals.
The EMF, and therefore the sensitivity and the range of measurement, depend on the nature
of the metals. Although many combinations of metals are possible, only specific ones are
selected, defining a limited range of types of thermocouple. Each type of thermocouple is
defined according to three tolerance classes: Class 1, 2 or 3. Each class corresponds to a
tolerance and an associated range where the tolerance is valid.
IEC 60584-2 gives detailed requirements about the classes of tolerance.
IEC 61515 gives general requirements regarding mineral insulated thermocouples and cables.
The environmental conditions in an NPP imply that only some types of thermocouples are
recommended.
Table 1 gives the most common thermocouple types. The given temperature range
corresponds to the superposition of the three classes of tolerances as described in
IEC 60584-2.
Table 1 − List of thermocouples and their use in an NPP
Type Positive Negative Typical Example of
Metal/Alloy Metal/Alloy temperature range application
°C
Primary circuit
Nickel − Chromium Nickel − Aluminium –200 to +1 150
K
PWR
Copper Copper − Nickel –200 to +350 Not in neutron flux
T
Iron Not in neutron flux
Copper − Nickel –40 to +750
J
Fuel temperature
Nickel − Chromium- Silicon Nickel − Silicon –200 to +1 200
N
Nickel − Chromium Copper − Nickel –200 to +750 Not in neutron flux
E
Tungsten – Rhenium (26 %) Not in neutron flux
Tungsten − Rhenium (5 %) 0 to +2 300
C
Platinum − Rhodium (13 %) Platinum 0 to +1 700 Not in neutron flux
R
Platinum Not in neutron flux
Platinum − Rhodium (10 %) 0 to +1 700
S
Platinum − Rhodium (30 %) Platinum Rhodium (6 %) +600 to +1 820 Not in neutron flux
B
Some other types of thermocouples based on Molybdenum – Niobium (MoNb) or their alloys
may be considered for high performance applications.
The categories (T, J, E, C, R, S, B ) are described in 5.2 for information only.
Only K, N and E types are generally used for nuclear applications, in accordance with the
limitations on exposure to neutron flux of Table 1.
62651 © IEC:2013 – 13 –
5.2 Types of thermocouples for nuclear applications
5.2.1 General
For nuclear applications, and specifically for measurement on and in the primary coolant
circuit of reactors, thermocouples with a robust design and a high quality shall be used. They
are protected within a metal sheath and insulated with a mineral material.
Thermocouples are used on water reactors for measurement of fuel channel outlet
temperature, which is particularly important in beyond design basis conditions. They may be
used in travelling fuel channel probes on water-cooled reactors, often for calibration
purposes. They are used on gas cooled reactors for measurements of fuel temperature, and
fuel channel outlet temperature, which are needed for reactor protection and for control, and
are also used for measurement of moderator and core support structural temperature.
More details are given in IEC 60737.
5.2.2 Type K
Type K thermocouple is the most widely used thermocouple. Its voltage output signal curve is
virtually linear against the temperature and has a good sensitivity. Type K thermocouples can
be used in temperatures up to 1 150 °C and, for short periods, up to 1 250 °C depending on
sheath material and diameter.
5.2.3 Type T
This thermocouple is not very commonly used. Its temperature range is limited to –200 °C up
to +350 °C. It is used in moist or negative temperature conditions because of its resistance to
corrosion and the greater homogeneity of the component wires that reduce errors due to
temperature gradients.
5.2.4 Type J
Type J Thermocouple has a limited temperature range: –40 °C to +750 °C. Its sensitivity
increases up to 55 µV/°C and its output signal can be changed by the contamination of the
iron. It is not recommended for nuclear applications.
5.2.5 Type N
This thermocouple has a good thermoelectric stability. It has an excellent oxidation resistance
at high temperature. It is well adapted for accurate measurements in air, up to 1 200 °C. In
vacuum or controlled atmosphere, it can withstand 1 300 °C depending on sheath materials
and diameter
N thermocouples are more stable than noble metal thermocouples (S or B) under radiation
conditions, but they are less stable at high temperature without radiation. Their drift depends
on the sheath material and the temperature. Under certains conditions Type K are more
stable than type N.
5.2.6 Type E
Thanks to its high sensitivity, the type E thermocouple is mainly used for cryogenic
measurements. As it is non-magnetic, it can be preferred for some specific applications.
5.2.7 Type C
The type C thermocouple is mainly used for high temperature measurements, specifically for
nuclear applications not subject to neutron flux.
– 14 – 62651 © IEC:2013
5.2.8 Noble metal thermocouples (Type S,R,B)
The noble metal thermocouples are dedicated to high temperature measurements (over
1 500 °C). Pure platinum and platinum/rhodium alloys develop smaller voltages than junctions
with common metal. These thermocouple become active and are not recommended for
nuclear applications.
6 Technology of thermocouple assemblies
6.1 Thermocouple assembly
6.1.1 General
A thermocouple is a sensitive element which delivers a small electric signal in direct relation
with the temperature. It can be used in association with mechanical and electrical components
(thermowell, cables, junction box), to position, protect and connect it to an electronic device
for signal processing. The set of these components is the thermocouple assembly. This
standard refers to the thermocouple assemblies and their use in an NPP.
The basic structure of a thermocouple used in NPP is a mineral insulated cable with the
thermocouple junction at the end of the cable. Two structures are possible:
• Insulated or ungrounded structure when the thermocouple is not electrically connected to
the sheath.
• Grounded structure when the thermocouple is in direct contact with the envelope of the
sheath.
Figure 2 shows the two possible structures of a thermocouple
Thermocouple (hot junction)
Thermocouple – insulated or ungrounded structure
Mineral insulated cable
Thermocouple (hot junction)
Thermocouple – grounded structure
IEC 803/13
Figure 2 − Electrical structures of a thermocouple
Depending on the nature of the substance whose temperature is measured (gas, liquid, solid)
and the conditions of measurement (fixed, flow rate, electrical conditions), the mechanical
arrangement of the thermocouple will differ according to:
• direct contact with the component;
62651 © IEC:2013 – 15 –
• direct immersion;
• protected in a metallic support (thermowell) .
6.1.2 Direct contact
The end of the thermocouple is welded or fixed on the metallic surface of the component. This
is for example the typical arrangement for the incore thermocouple for the measurement of in-
core temperature on the surface of the fuel element.
6.1.3 Direct immersion
The thermocouple is in direct contact with the fluid of which the temperature is measured.
6.1.4 Thermowell mounted
In the case of the measurement of the temperature of a fluid in a circuit, the thermocouple is
generally inserted in a protective support called the thermowell.
The use of a thermowell makes any replacement of the thermocouple easier.
The mechanical contact of the end of the thermocouple with the envelope of the thermowell is
important regarding the accuracy and the response time.
6.2 Performance
6.2.1 Accuracy
The accuracy of a thermocouple depends on the characteristics of the materials themselves
and the accuracy of the cold junction temperature measurement. IEC 60584-2 specifies the
amount by which the measurements may deviate from ideal behaviour for each type of
thermocouple. Three classes of tolerance are defined in Table 1 of IEC 60584-2:1982. The
class of tolerance of a thermocouple depends on the manufacturing process.
6.2.2 Range of measurement
The range of measurement is given by the type of the thermocouple as indicated above. The
range differs according to the class of tolerance as indicated in IEC 60584-2.
6.2.3 Response time
The response time of a thermocouple assembly depends on its structure including the
thermowell.
The response time of a thermocouple depends on the diameter of the wires, the mass of
materials around the junction and its efficiency in transferring heat from its outer surfaces to
the wire sensing element. A thermocouple can be shaped in order to reduce the thermal
inertia and to shorten the response time.
For NPP applications, the response time requirement shall be specified according to the
functions to be performed.
6.2.4 Reliability
The reliability requirement of thermocouples used for safety functions are defined from
reliability requirements of the safety system. Experience of carefully manufactured
thermocouples provided with high Quality Assurance and Quality Control requirements for
NPP applications is that their reliability is high. Thermocouples operated in safety systems
should have their design lives defined. For thermocouples whose design life is less than the
– 16 – 62651 © IEC:2013
design life of the NPP or the safety system, then arrangement shall be made for these
thermocouples to be replaced or re-assessed before their design life is reached.
6.3 Design and construction requirements
6.3.1 General
The thermocouple and its associated devices shall meet the requirements described in this
standard and in IEC 60737. Safety or other requirements for the application shall be
determined according to national and international requirements and practice, including
IEC 61513.
6.3.2 Reference junctions
A thermocouple is a differential device giving an electric signal related to the difference of
temperature between the hot junction (to be measured) and the cold junction (reference). The
cold junction is typically not kept at a known temperature but rather the temperature is
measured at the cold junction and this measurement is used to perform the cold junction
temperature compensation to obtain the actual process temperature at the measurement
junction.
6.3.3 Construction principles
Thermocouples can be supplied in different internal constructions, which depend on the
manufacture, qualification requirements, and applications. For thermocouples being used in
an NPP, the design and structure of the thermocouple should consider the environmental
conditions in which the sensor is being used under normal operating and under design basis
accident conditions, as well as the qualification tests specified by the user. The use of a
flexible mineral-insulated cable between the thermocouple and the connector is commonly
adopted, and the user may also adopt any other construction. A variation of this design may
include a rigid exterior sheath over the mineral-insulated cable between the thermocouple and
the connector, this sheath being welded to the connector.
Thermocouples can be manufactured with various forms depending on the conditions of the
measurement.
Three types of thermocouple are commonly used:
• Simple thermocouple: The wires are not protected and separate from each other, the hot
junction is directly fastened or soldered onto the surface of the component. This type is
not normally used in NPPs.
• Thermocouple with a grounded hot junction: The wires are isolated from each other
(except at the junction itself) and inserted in a metallic protective sheath. The hot junction
is electrically connected to the protective sheath.
• Thermocouple with an isolated hot junction (i.e. ungrounded): The wires are isolated from
each other (except at the junction itself) and inserted in a protective sheath. The hot
junction is electrically isolated from the protective sheath.
The methods of manufacture of the measuring junction are:
• exposed junction − the thermocouple is made with the junction extended beyond the end
of the sheath and insulant and remaining unprotected, such arrangements are not
normally used;
• grounded junction − the conductors are welded to the end cap, which is welded to the
sheath to form the closure;
• ungrounded or isolated
...