IEC 61340-4-5:2004
(Main)Electrostatics - Part 4-5: Standard test methods for specific applications - Methods for characterizing the electrostatic protection of footwear and flooring in combination with a person
Electrostatics - Part 4-5: Standard test methods for specific applications - Methods for characterizing the electrostatic protection of footwear and flooring in combination with a person
Specifies test methods for evaluating electrostatic protection provided by a system of footwear and flooring in combination with a person. The test methods are not intended for individual material or system classification purposes.
Electrostatique - Partie 4-5: Méthodes d'essai normalisées pour des applications spécifiques - Méthodes de caractérisation de la protection électrostatique des chaussures et des revêtements de sol par rapport à une personne
Spécifie des méthodes d'essai pour l'évaluation de la protection électrostatique fournie par un système de chaussures et de revêtement de sol par rapport à une personne. Ces méthodes d'essai ne sont pas destinées à la classification des matériaux et systèmes individuels.
General Information
Relations
Standards Content (Sample)
NORME CEI
INTERNATIONALE IEC
61340-4-5
INTERNATIONAL
Première édition
STANDARD
First edition
2004-07
Electrostatique–
Partie 4-5:
Méthodes d'essai normalisées
pour des applications spécifiques –
Méthodes de caractérisation de la protection
électrostatique des chaussures et des
revêtements de sol par rapport à une personne
Electrostatics –
Part 4-5:
Standard test methods for specific applications –
Methods for characterizing the electrostatic
protection of footwear and flooring in
combination with a person
Numéro de référence
Reference number
CEI/IEC 61340-4-5:2004
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
61340-4-5
INTERNATIONAL
Première édition
STANDARD
First edition
2004-07
Electrostatique–
Partie 4-5:
Méthodes d'essai normalisées
pour des applications spécifiques –
Méthodes de caractérisation de la protection
électrostatique des chaussures et des
revêtements de sol par rapport à une personne
Electrostatics –
Part 4-5:
Standard test methods for specific applications –
Methods for characterizing the electrostatic
protection of footwear and flooring in
combination with a person
© IEC 2004 Droits de reproduction réservés ⎯ Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
P
Commission Electrotechnique Internationale PRICE CODE
International Electrotechnical Commission
ɆɟɠɞɭɧɚɪɨɞɧɚɹɗɥɟɤɬɪɨɬɟɯɧɢɱɟɫɤɚɹɄɨɦɢɫɫɢɹ
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61340-4-5 © CEI:2004
SOMMAIRE
AVANT-PROPOS.4
1 Domaine d’application .8
2 Références normatives.8
3 Termes et définitions .8
4 Principe.8
5 Atmosphère pour conditionnement et essais.10
6 Méthodes d'essai des chaussures et des revêtements de sol par rapport à une
personne .10
6.1 Echantillonnage du revêtement de sol et préparation de l'éprouvette pour les
essais de laboratoire .10
6.2 Nettoyage des chaussures pour les évaluations de laboratoire et pour les
essais sur les revêtements de sol finis .12
6.3 Mesure de la résistance électrique .12
6.4 Mesure de l'aptitude à la charge.16
7 Rapport d'essai .18
Annexe A Méthode de vérification de l'étalonnage du système de mesure de la
tension du corps .28
Figure 1 – Montages pour la mesure de la résistance électrique des chaussures
et des revêtements de sol par rapport à une personne.24
Figure 2 – Enregistrements de la tension du corps utilisés pour le calcul des valeurs
moyennes .26
61340-4-5 ” IEC:2004 – 3 –
CONTENTS
FOREWORD.5
1 Scope .9
2 Normative references .9
3 Terms and definitions .9
4 Principle.9
5 Atmosphere for conditioning and testing.11
6 Test methods for footwear and flooring in combination with a person .11
6.1 Floor covering sampling and specimen preparation for laboratory tests.11
6.2 Cleaning of footwear for laboratory evaluations and for test on installed floor
coverings .13
6.3 Measurement of electrical resistance .13
6.4 Measurement of chargeability .17
7 Test report .19
Annex A (normative) Method of checking calibration of body voltage measuring system .29
Figure 1 – Set-ups for measuring electrical resistance of footwear and flooring
in combination with a person.25
Figure 2 – Typical body voltage recordings showing points used in calculating mean
values .27
– 4 – 61340-4-5 © CEI:2004
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
ÉLECTROSTATIQUE –
Partie 4-5: Méthodes d'essai normalisées
pour des applications spécifiques –
Méthodes de caractérisation de la protection électrostatique des
chaussures et des revêtements de sol par rapport à une personne
AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes
internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au
public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des
comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent
également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable
de l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 61340-4-5 a été établie par le comité d'études 101 de la CEI:
Electrostatique.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
101/178/FDIS 101/186/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 2.
61340-4-5 © IEC:2004 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
ELECTROSTATICS –
Part 4-5: Standard test methods for specific applications –
Methods for characterizing the electrostatic protection
of footwear and flooring in combination with a person
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61340-4-5 has been prepared by IEC technical committee 101:
Electrostatics.
The text of this standard is based on the following documents:
FDIS Report on voting
101/178/FDIS 101/186/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
– 6 – 61340-4-5 © CEI:2004
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de
maintenance indiquée sur le site web de la CEI sous «http://webstore.iec.ch» dans les
données relatives à la publication recherchée. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
61340-4-5 © IEC:2004 – 7 –
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
– 8 – 61340-4-5 © CEI:2004
ÉLECTROSTATIQUE –
Partie 4-5: Méthodes d'essai normalisées
pour des applications spécifiques –
Méthodes de caractérisation de la protection électrostatique des
chaussures et des revêtements de sol par rapport à une personne
1 Domaine d’application
La présente partie de la CEI 61340 spécifie des méthodes d'essai pour l'évaluation de la
protection électrostatique fournie par un système de chaussures et de revêtement de sol par
rapport à une personne.
Ces méthodes d'essai ne sont pas destinées à la classification des matériaux et systèmes
individuels.
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent
document. Pour les références datées, seule l'édition citée s'applique. Pour les références
non datées, la dernière édition du document de référence s'applique (y compris les éventuels
amendements).
CEI 60093, Méthodes pour la mesure de la résistivité transversale et de la résistivité
superficielle des matériaux isolants électriques solides
CEI 61340-4-1, Electrostatique – Partie 4-1: Méthodes d'essai normalisées pour des applica-
tions spécifiques –Résistance électrique des revêtements de sol et des sols finis
ISO 1957, Revêtements de sol textiles fabriqués à la machine – Sélection et prélèvement des
éprouvettes en vue des essais physiques
3 Termes et définitions
Pour les besoins du présent document, les termes et les définitions de la CEI 61340-1-2
s'appliquent.
4 Principe
Un système est caractérisé en mesurant la résistance électrique et l'aptitude à la charge des
chaussures et des revêtements de sol par rapport à une personne. L'aptitude à la charge est
déterminée en utilisant un essai de marche.
AVERTISSEMENT: Les procédures d'essai décrites dans la présente norme peuvent exposer le personnel à des
conditions électriques potentiellement dangereuses. Il convient de recourir à des pratiques appropriées de
réduction des risques électriques et de suivre les instructions adaptées pour relier l'équipement utilisé à la terre
pendant les essais.
61340-4-5 © IEC:2004 – 9 –
ELECTROSTATICS –
Part 4-5: Standard test methods for specific applications –
Methods for characterizing the electrostatic protection
of footwear and flooring in combination with a person
1 Scope
This part of IEC 61340 specifies test methods for evaluating electrostatic protection provided
by a system of footwear and flooring in combination with a person.
The test methods are not intended for individual material or system classification purposes.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60093, Methods of test for volume resistivity and surface resistivity of solid electrical
insulating materials
IEC 61340-4-1, Electrostatics – Part 4-1: Standard test methods for specific applications –
Electrostatic resistance of floor coverings and installed floors
ISO 1957, Machine-made textile floor coverings – Selection and cutting of specimens for
physical tests
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 61340-1-2 apply.
4 Principle
The characterization of a system is achieved by measuring electrical resistance and
chargeability of the footwear and flooring in combination with a person. Chargeability is
determined using a walking test.
WARNING: Test procedures described in this standard may expose personnel to potentially hazardous electrical
conditions. Appropriate electrical hazard reduction practices should be exercised and proper earthing instructions
for the equipment used should be followed when performing tests.
– 10 – 61340-4-5 © CEI:2004
5 Atmosphère pour conditionnement et essais
Les exigences suivantes annulent toutes les autres spécifications concernant l'atmosphère
pour le conditionnement et les essais qui peuvent être données dans un ou plusieurs
documents cités en référence dans la présente norme.
Sauf accord contraire, l'atmosphère pour le conditionnement et les essais dans le cadre des
évaluations en laboratoire doit présenter une température de (23 ± 2) °C et une humidité
relative de (12 ± 3) %. Le temps de conditionnement avant les essais doit être d'au moins
48 h. Les revêtements de sol en textile sont de préférence préconditionnés pendant au moins
24 h à (20 ± 2) °C et avec une humidité relative de (65 ± 3) % avant le conditionnement et les
essais.
Pendant le préconditionnement et le conditionnement, les éprouvettes doivent être placées
sur une baie ou sur un autre support adapté qui permet une libre circulation de l'air autour
d'elles.
Lorsque des essais sont effectués dans des conditions non contrôlées, par exemple, des
essais sur des sols finis, la température ambiante et l'humidité relative au moment de la
mesure doivent être enregistrées.
6 Méthodes d'essai des chaussures et des revêtements de sol par rapport à
une personne
6.1 Echantillonnage du revêtement de sol et préparation de l'éprouvette pour les
essais de laboratoire
L'échantillonnage et la sélection des éprouvettes pour les essais en laboratoire doivent être
réalisés conformément aux principes spécifiés dans l'ISO 1957. Pour les besoins de la
présente norme, les principes généraux de l'ISO 1957 s'appliquent à tous les types de
revêtement de sol. Prélever sur chaque échantillon une éprouvette mesurant (2 ± 0,1) m ×
(1 ± 0,1) m ou, dans le cas de dalles, sélectionner suffisamment de dalles et/ou de parties de
dalles pour réaliser une zone éprouvette unique de (2 ± 0,1) m × (1 ± 0,1) m.
Pour les essais sur les revêtements de sol qui seront installés avec des liaisons à la terre
spécifiques, un point pouvant être relié à la terre doit être fixé à l'éprouvette conformément
aux instructions du fabricant ou à tout autre accord conclu d'une manière qui simule les
méthodes de mise à la terre en utilisation finale. Pour les essais de l'aptitude à la charge sur
les revêtements de sol qui seront installés sans liaisons à la terre spécifiques, des points de
mise à la terre ne doivent pas être fixés à l'éprouvette.
Des mesures de résistance électrique sensibles ne peuvent pas être réalisées en laboratoire
sur les revêtements de sol qui seront installés sans liaisons à la terre spécifiques. Des
mesures de la résistance électrique des chaussures et des revêtements de sol par rapport à
une personne ne doivent être réalisées sur de tels revêtements de sol qu'après installation.
L'éprouvette doit être montée ou posée librement sur un panneau dur normal ou trempé de
dimension nominale de 6,3 mm, conformément aux instructions du fabricant ou à tout autre
accord conclu. Qu'elle soit montée ou posée librement sur le panneau dur, il doit y avoir un
espace d'au moins 10 mm entre chaque bord de l'éprouvette et le bord correspondant du
panneau dur.
Le panneau dur doit être propre, lisse et avoir une résistance point à point supérieure à
10 Ω lorsque l'essai est effectué dans les conditions environnementales spécifiées à
l'Article 5 de la présente norme et conformément à la méthode d'essai spécifiée dans la
CEI 61340-4-1.
61340-4-5 © IEC:2004 – 11 –
5 Atmosphere for conditioning and testing
The following requirements supersede any other specification for the atmosphere for
conditioning and testing that may be given in one or more of the documents referred to in this
standard.
Unless otherwise agreed, the atmosphere for conditioning and testing for laboratory
evaluations shall be (23 ± 2) °C and (12 ± 3) % relative humidity. The conditioning time prior
to testing shall be at least 48 h. Textile floor coverings are preferably pre-conditioned for at
least 24 h at (20 ± 2) °C and (65 ± 3) % relative humidity prior to conditioning and testing.
During pre-conditioning and conditioning, specimens shall be placed on a rack or other
suitable support that allows free circulation of air around them.
Whenever tests are made in uncontrolled conditions, e.g. tests on installed floors, the ambient
temperature and relative humidity at the time of measurement shall be recorded.
6 Test methods for footwear and flooring in combination with a person
6.1 Floor covering sampling and specimen preparation for laboratory tests
Sampling and selection of specimens for laboratory tests shall be carried out according to the
principles specified in ISO 1957. For the purposes of this standard, the general principles of
ISO 1957 apply to all types of floor covering. From each sample select a specimen measuring
(2 ± 0,1) m × (1 ± 0,1) m or, in the case of tiles, select sufficient tiles and/or part tiles to make
up a single specimen area of (2 ± 0,1) m × (1 ± 0,1) m.
For tests on floor coverings that will be installed with specific earth connections, a groundable
point shall be attached to the test specimen in accordance with the manufacturer’s
instructions, or as otherwise agreed, and in a way that simulates end use earthing methods.
For chargeability tests on floor coverings that will be installed without specific earth
connections, groundable points shall not be attached to the test specimen.
Sensible electrical resistance measurements cannot be made in the laboratory on floor
coverings that will be installed without specific earth connections. Measurement of the
electrical resistance of footwear and flooring in combination with a person shall only be made
on such floor coverings once installed.
The test specimen shall be mounted or loose-laid on nominal 6,3 mm tempered or standard
hardboard, according to the manufacturer’s instructions or as otherwise agreed. When
mounted or loose-laid on the hardboard there shall be a gap of at least 10 mm between each
edge of the specimen and the corresponding edge of the hardboard.
The hardboard shall be clean, smooth and have a point-to-point resistance of greater than
10 Ω when tested under the environmental conditions specified in Clause 5 of this standard
and according to the test method specified in IEC 61340-4-1.
– 12 – 61340-4-5 © CEI:2004
Les finitions des sols doivent être soumises aux essais avec des revêtements de sol
représentatifs du type pour lequel ces finitions sont prévues. Le revêtement de sol doit être
préparé et monté comme indiqué plus haut en détails. La finition en essai doit ensuite être
appliquée au revêtement conformément aux instructions du fabricant ou selon tout autre
accord conclu. Lorsque le fabricant recommande l'utilisation de points supplémentaires de
mise à la terre sur la surface du revêtement de sol, ceux-ci doivent être installés selon les
instructions du fabricant avant application de la finition ou selon tout autre accord conclu.
NOTE Généralement, les essais sont réalisés sur les revêtements de sol tels qu'ils sont reçus, c'est-à-dire avec
les finitions et traitements spéciaux, le cas échéant. Si la permanence de telles finitions et traitements est étudiée,
les éprouvettes peuvent être soumises, avant l'essai, à un processus de nettoyage ou à des conditions d'usure
comme ce qui existe dans la pratique, soit pour les évaluations en laboratoire soit sur les revêtements de sol finis.
Les résultats d'essai peuvent être affectés de manière importante par la présence de saleté
ou d'autres contaminants sur la surface des revêtements de sol. Tout nettoyage réalisé sur
les revêtements de sol doit être effectué selon les instructions du fabricant avant le
conditionnement.
6.2 Nettoyage des chaussures pour les évaluations de laboratoire et pour les essais
sur les revêtements de sol finis
Les résultats d'essai peuvent être affectés de manière importante par la présence de saleté
ou d'autres contaminants sur les semelles des chaussures. Tout nettoyage des chaussures
avant et pendant les essais doit être réalisé comme suit. S'il est exigé que les chaussures
subissent l'essai dans l'état de réception ou telles qu'elles sont utilisées, alors le nettoyage
doit être ignoré dans la procédure d'essai.
6.2.1 Matériaux de nettoyage
6.2.1.1 Papier abrasif
Papier abrasif P280.
...