- Abstract
IEC 60603-7-81:2015 Covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements, including power sum alien (exogenous) crosstalk, for frequencies up to 2 000 MHz. These connectors are typically used as "category 8.1" connectors in "class I" cabling systems specified in ISO/IEC 11801. These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in Clause 2 of IEC 60603-7. These connectors are backward compatible with other IEC 60603-7 series connectors, except IEC 60603-7-7 and IEC 60603-7-71 connectors. Key words: Connectors, Shielded, Free and Fixed Connectors
The contents of the corrigendum of June 2017 have been included in this copy.
- Status
- Published
- Publication Date
- 15-Dec-2015
- Technical Committee
- SC 48B - Electrical connectors
- Drafting Committee
- WG 3 - Connectors
- Current Stage
- PPUB - Publication issued - 60 Publication
- Start Date
- 16-Dec-2015
- Due Date
- 15-Dec-2015
- Completion Date
- 15-Dec-2015
Buy Documents
IEC 60603-7-81:2015 - Connectors for electronic equipment - Part 7-81: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 2 000 MHz Released:12/16/2015
Overview
IEC 60603-7-81:2015 is an international standard published by the International Electrotechnical Commission (IEC) that specifies detailed requirements for 8-way, shielded connectors used in electronic equipment. These connectors support data transmissions with frequencies up to 2000 MHz, making them ideal for high-speed data communication applications.
This standard covers both free and fixed connectors, addressing their dimensional, mechanical, electrical, and environmental characteristics. It also defines critical electrical transmission requirements such as power sum alien (exogenous) crosstalk, essential for maintaining signal integrity in high-frequency data transmissions. IEC 60603-7-81:2015 connectors are commonly used as "Category 8.1" connectors within "Class I" cabling systems as per ISO/IEC 11801.
The connectors specified are intermateable and interoperable with other IEC 60603-7 series connectors, providing backward compatibility except with IEC 60603-7-7 and IEC 60603-7-71 connectors. A corrigendum issued in June 2017 has been incorporated, ensuring the latest updates are included.
Key Topics
- Connector Types: Specification includes both free (plug) and fixed (socket or outlet) 8-way shielded connectors.
- Frequency Range: Designed for data transmissions up to 2000 MHz for high-bandwidth performance.
- Electrical Performance:
- Transfer impedance and insertion loss
- Return loss and propagation delay
- Delay skew and near-end crosstalk (NEXT)
- Power sum NEXT and far-end crosstalk (FEXT)
- Alien (exogenous) crosstalk for minimizing signal interference in adjacent cables
- Mechanical Characteristics:
- Pin and pair assignments standardized for consistency
- Dimensional requirements ensure compatibility
- Testing for durability under environmental stress and mechanical vibration
- Testing Procedures:
- Defined test schedules including contact resistance, vibration, climatic conditioning
- Measurement methods for electrical and mechanical properties to ensure compliance
- Compatibility:
- Interoperable within IEC 60603-7 series connectors
- Backward compatibility enhances ease of integration into existing systems
- Applications within Cabling Systems:
- Certified for use in Class I cabling systems in line with ISO/IEC 11801 standards
- Often specified for Category 8.1 network infrastructures requiring shielded connectors for high-speed data transmission
Applications
IEC 60603-7-81:2015 connectors are essential components for:
- High-Speed Data Communications: Support for data rates requiring transmission frequencies up to 2 GHz makes these connectors suitable for advanced networking gear, data centers, and telecommunication equipment.
- Category 8.1 Ethernet Cabling: Critical in the deployment of shielded twisted-pair cabling systems where interference immunity and high bandwidth are mandatory.
- Industrial Automation and Control Systems: Ensure reliable signal transmission in electrically noisy environments with shielded connectors that minimize crosstalk and external interference.
- Professional Audio and Video Equipment: Maintain signal integrity over high-frequency data links.
- Testing and Measurement Devices: Used for instrument connections requiring precise signal fidelity at microwave frequencies.
- Backward-Compatible Installations: Upgrade existing installations easily with connectors interoperable with prior IEC 60603-7 series components.
These practical deployments benefit from the standard’s rigorous specification and testing requirements, ensuring connectors deliver the electrical and mechanical performance necessary for reliable operation under demanding conditions.
Related Standards
For comprehensive compliance and system design, the following related standards and specifications should be considered alongside IEC 60603-7-81:
- ISO/IEC 11801: International standard for generic cabling for customer premises, defining Class I components and Category 8.1 cabling systems.
- IEC 60603-7 (Base Document): Defines general dimensional, mechanical, electrical, and environmental characteristics for connectors covered in the 60603-7 series.
- IEC 60603-7 Series: Other parts specify connectors for different frequency ranges and shielding options:
- IEC 60603-7-1 to IEC 60603-7-7 for various connector types and shielding levels
- IEC 60603-7-82 for 8-way, shielded connectors supporting frequencies up to 2000 MHz with different performance criteria
- IEC 61076 Series: Standards covering circular and rectangular connectors for industrial and instrumentation applications.
- IEC 60512 Series: Standard methods for testing connector performance to ensure reliability.
- Relevant Regulatory and Certification Standards: Local standards for electrical safety and electromagnetic compatibility may also apply to installation environments.
Conclusion
IEC 60603-7-81:2015 provides a critical framework for manufacturers, system designers, and installers using 8-way, shielded connectors to achieve high-frequency data transmissions up to 2 GHz. By adhering to this standard, stakeholders ensure interoperability, backward compatibility, and reliable electrical and mechanical performance-key factors for modern high-speed network infrastructures and electronic equipment connectivity solutions.
Keywords: IEC 60603-7-81, 8-way shielded connectors, high-speed data connectors, Category 8.1 connectors, Class I cabling, power sum alien crosstalk, data transmission connectors, IEC 60603-7 series, shielded electronic connectors, connector testing standards.
Relations
- Effective Date
- 05-Sep-2023
Buy Documents
IEC 60603-7-81:2015 - Connectors for electronic equipment - Part 7-81: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 2 000 MHz Released:12/16/2015
Frequently Asked Questions
IEC 60603-7-81:2015 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Connectors for electronic equipment - Part 7-81: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 2 000 MHz". This standard covers: IEC 60603-7-81:2015 Covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements, including power sum alien (exogenous) crosstalk, for frequencies up to 2 000 MHz. These connectors are typically used as "category 8.1" connectors in "class I" cabling systems specified in ISO/IEC 11801. These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in Clause 2 of IEC 60603-7. These connectors are backward compatible with other IEC 60603-7 series connectors, except IEC 60603-7-7 and IEC 60603-7-71 connectors. Key words: Connectors, Shielded, Free and Fixed Connectors The contents of the corrigendum of June 2017 have been included in this copy.
IEC 60603-7-81:2015 Covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements, including power sum alien (exogenous) crosstalk, for frequencies up to 2 000 MHz. These connectors are typically used as "category 8.1" connectors in "class I" cabling systems specified in ISO/IEC 11801. These connectors are intermateable and interoperable with other IEC 60603-7 series connectors as defined in Clause 2 of IEC 60603-7. These connectors are backward compatible with other IEC 60603-7 series connectors, except IEC 60603-7-7 and IEC 60603-7-71 connectors. Key words: Connectors, Shielded, Free and Fixed Connectors The contents of the corrigendum of June 2017 have been included in this copy.
IEC 60603-7-81:2015 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 60603-7-81:2015 has the following relationships with other standards: It is inter standard links to IEC 60603-7-81:2015/COR1:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 60603-7-81:2015 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 60603-7-81 ®
Edition 1.0 2015-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment –
Part 7-81: Detail specification for 8-way, shielded, free and fixed connectors, for
data transmissions with frequencies up to 2 000 MHz
Connecteurs pour équipements électroniques –
Partie 7-81: Spécification particulière pour les fiches et les embases blindées à
8 voies pour la transmission de données à des fréquences jusqu’à 2 000 MHz
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.
IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing more than 30 000 terms and
Technical Specifications, Technical Reports and other definitions in English and French, with equivalent terms in 15
documents. Available for PC, Mac OS, Android Tablets and additional languages. Also known as the International
iPad. Electrotechnical Vocabulary (IEV) online.
IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a More than 60 000 electrotechnical terminology entries in
variety of criteria (reference number, text, technical English and French extracted from the Terms and Definitions
committee,…). It also gives information on projects, replaced clause of IEC publications issued since 2002. Some entries
and withdrawn publications. have been collected from earlier publications of IEC TC 37,
77, 86 and CISPR.
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.
Catalogue IEC - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
Application autonome pour consulter tous les renseignements
Le premier dictionnaire en ligne de termes électroniques et
bibliographiques sur les Normes internationales,
électriques. Il contient plus de 30 000 termes et définitions en
Spécifications techniques, Rapports techniques et autres
anglais et en français, ainsi que les termes équivalents dans
documents de l'IEC. Disponible pour PC, Mac OS, tablettes
15 langues additionnelles. Egalement appelé Vocabulaire
Android et iPad.
Electrotechnique International (IEV) en ligne.
Recherche de publications IEC - www.iec.ch/searchpub
Glossaire IEC - std.iec.ch/glossary
La recherche avancée permet de trouver des publications IEC Plus de 60 000 entrées terminologiques électrotechniques, en
en utilisant différents critères (numéro de référence, texte, anglais et en français, extraites des articles Termes et
comité d’études,…). Elle donne aussi des informations sur les Définitions des publications IEC parues depuis 2002. Plus
projets et les publications remplacées ou retirées. certaines entrées antérieures extraites des publications des
CE 37, 77, 86 et CISPR de l'IEC.
IEC Just Published - webstore.iec.ch/justpublished
Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications IEC. Just
Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur cette
Disponible en ligne et aussi une fois par mois par email. publication ou si vous avez des questions contactez-nous:
csc@iec.ch.
IEC 60603-7-81 ®
Edition 1.0 2015-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment –
Part 7-81: Detail specification for 8-way, shielded, free and fixed connectors, for
data transmissions with frequencies up to 2 000 MHz
Connecteurs pour équipements électroniques –
Partie 7-81: Spécification particulière pour les fiches et les embases blindées à
8 voies pour la transmission de données à des fréquences jusqu’à 2 000 MHz
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 31.220.10 ISBN 978-2-8322-3009-1
– 2 – IEC 60603-7-81:2015 © IEC 2015
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 8
2 Normative references . 8
3 Terms and definitions . 9
4 Cable terminations and internal connections – Fixed and free connectors . 9
5 Gauge . 9
6 Characteristics . 9
6.1 General . 9
6.1.1 Overview . 9
6.1.2 Pin and pair grouping assignment . 9
6.1.3 Classification into climatic category . 9
6.2 Electrical characteristics . 10
6.2.1 General . 10
6.2.2 Transfer impedance . 10
6.3 Transmission characteristics . 10
6.3.1 General . 10
6.3.2 Insertion loss . 10
6.3.3 Return loss . 10
6.3.4 Propagation delay . 11
6.3.5 Delay skew . 11
6.3.6 NEXT loss . 11
6.3.7 Power sum NEXT loss . 11
6.3.8 FEXT Loss . 12
6.3.9 Power sum FEXT loss . 12
6.3.10 Transverse conversion loss . 12
6.3.11 Transverse conversion transfer loss . 12
6.3.12 Coupling attenuation . 12
6.3.13 Power sum alien (exogenous) NEXT . 13
6.3.14 Power sum alien (exogenous) FEXT . 13
6.3.15 Mechanical . 13
6.3.16 Pin assignment . 13
7 Tests and test schedule . 14
7.1 General . 14
7.2 Arrangement for contact resistance test . 14
7.3 Arrangement for vibration test . 14
7.4 Test procedures and measuring methods . 14
7.5 Preconditioning . 14
7.6 Wiring and mounting of specimens . 14
7.6.1 Wiring . 14
7.6.2 Mounting . 14
8 Test schedules . 14
8.1 General . 14
8.2 Basic (minimum) test schedule. 14
8.3 Full test schedule . 14
8.3.1 General . 14
8.3.2 Test group P preliminary . 14
8.3.3 Test group AP . 15
8.3.4 Test group BP . 15
8.3.5 Test group CP . 15
8.3.6 Test group DP . 15
8.3.7 Test group EP . 15
8.3.8 Test group FP . 16
8.3.9 Test group GP . 16
Bibliography . 17
Table 1 – Test Group EP . 15
– 4 – IEC 60603-7-81:2015 © IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
Part 7-81: Detail specification for 8-way, shielded, free and fixed
connectors, for data transmissions with frequencies up to 2 000 MHz
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
International Standard IEC 60603-7-81 has been prepared by subcommittee 48B: Electrical
connectors, of IEC technical committee 48: Electrical connectors and mechanical structures
for electrical and electronic equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
48B/2451/FDIS 48B/2464/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 60603 series, published under the general title Connectors for
electronic equipment, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC website under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
The contents of the corrigendum of June 2017 have been included in this copy.
– 6 – IEC 60603-7-81:2015 © IEC 2015
INTRODUCTION
IEC 60603-7 is the base specification of the whole series. Subsequent specifications do not
duplicate information given in the base document, but list only additional requirements. For
complete specification regarding a component of a higher number document all lower
numbered documents shall be considered as well. The following diagram shows the
interrelation of the documents:
Unshielded Shielded
3 MHz
IEC 60603-7 IEC 60603-7-1
100 MHz
IEC 60603-7-2 IEC 60603-7-3
250 MHz
IEC 60603-7-4 IEC 60603-7-5
500 MHz
IEC 60603-7-41 IEC 60603-7-51
600 MHz
IEC 60603-7-7
1 000 MHz
IEC 60603-7-71
2 000 MHz
IEC 60603-7-81
2 000 MHz
IEC 60603-7-82
Key
Indicates reference for
dimensions, mechanical and
electrical characteristics, tests
and test schedules
Indicates reference for
transmission performance
(backward compatibility)
IEC
The International Electrotechnical Commission (IEC) draws attention to the fact that it is
claimed that compliance with this document may involve the use of a patent concerning
transmission characteristics given in 6.2.
IEC takes no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured the IEC that he/she is willing to negotiate licences
either free of charge or under reasonable and non-discriminatory terms and conditions with
applicants throughout the world. In this respect, the statement of the holder of this patent
right is registered with IEC. Information may be obtained from:
CommScope INC of North Carolina
110 CommScope Place SE
Hickory North Carolina USA 28602
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights other than those identified above. IEC shall not be held responsible for
identifying any or all such patent rights.
ISO (www.iso.org/patents) and IEC (http://patents.iec.ch) maintain on-line data bases of
patents relevant to their standards. Users are encouraged to consult the data bases for the
most up to date information concerning patents.
– 8 – IEC 60603-7-81:2015 © IEC 2015
CONNECTORS FOR ELECTRONIC EQUIPMENT –
Part 7-81: Detail specification for 8-way, shielded, free and fixed
connectors, for data transmissions with frequencies up to 2 000 MHz
1 Scope
This part of IEC 60603 covers 8-way, shielded, free and fixed connectors, references
dimensional, mechanical, electrical and environmental characteristics and tests in
IEC 60603-7, and specifies electrical transmission requirements, including power sum alien
(exogenous) crosstalk, for frequencies up to 2 000 MHz.
These connectors are typically used as “category 8.1” connectors in “class I” cabling systems
specified in ISO/IEC 11801.
These connectors are intermateable and interoperable with other IEC 60603-7 series
connectors as defined in Clause 2 of IEC 60603-7.
These connectors are backward compatible with other IEC 60603-7 series connectors, except
IEC 60603-7-7 and IEC 60603-7-71 connectors.
NOTE Transmission performance categories: in this IEC standard, the term “category”, when used in reference to
transmission performance, refers to those categories defined by ISO/IEC 11801.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60512-2-1, Connectors for electronic equipment – Tests and measurements – Part 2-1:
Electrical continuity and contact resistance tests – Test 2a: Contact resistance – Millivolt level
method
IEC 60512-25-9, Connectors for electronic equipment – Tests and measurements – Part 25-9:
Signal integrity tests – Test 25i: Alien crosstalk
IEC 60512-26-100, Connectors for electronic equipment – Tests and measurements –
Part 26-100: Measurement setup, test and reference arrangements and measurements for
connectors according to IEC 60603-7 – Tests 26a to 26g
nd
IEC 60512-28-100: (2 edition under consideration) Connectors for electronic equipment –
Tests and measurements – Part 28-100: Signal integrity tests up to 2 000 MHz on
IEC 60603-7 and IEC 61076-3 series connectors –Tests 28a to 28g
IEC 60603-7:2008, Connectors for electronic equipment – Part 7: Detail specification for
8-way, unshielded, free and fixed connectors
IEC 60603-7-1:2011, Connectors for electronic equipment – Part 7-1: Detail specification for
8-way, shielded, free and fixed connectors
IEC 61156 (all parts), Multicore and symmetrical pair/quad cables for digital communications
IEC 62153-4-15: Metallic communication cable test methods – Part 4-15: Electromagnetic
compatibility (EMC) – Test method for measuring transfer impedance and screening
attenuation or coupling attenuation with triaxial cell
3 Terms and definitions
For the purposes of this document, the terms and definitions of Clause 2 of IEC 60603-7,
apply as well as the following.
3.1
backward compatibility
a set of requirements ensuring that a free or fixed connector which is in compliance with this
standard, mated with a fixed or free connector in compliance with any lower frequency
IEC 60603-7 series connector, fully complies with the requirements of the lower frequency
IEC 60603-7 series connector, except 60603-7-7 and 60603-7-71
Note 1 to entry: The complete specification of the categories and the backward compatibility system for the
IEC 60603-7 series connectors, when used in standard ISO/IEC 11801-1 balanced cabling systems, is specified in
referenced ISO/IEC 11801-1.
See Clause 3 of IEC 60603-7-1:2011 for dimensions, views and requirements.
4 Cable terminations and internal connections – Fixed and free connectors
See Clause 4 of IEC 60603-7-1:2011 for cable termination and internal connections types.
5 Gauge
The gauge as defined by Clause 5 of IEC 60603-7-1:2011 shall apply.
6 Characteristics
6.1 General
6.1.1 Overview
Connectors according to this standard shall meet all relevant requirements specified by
IEC 60603-7-1.
6.1.2 Pin and pair grouping assignment
The pin and pair grouping assignment of Figure 9 of 6.2 of IEC 60603-7:2008 applies.
6.1.3 Classification into climatic category
Connectors according to this standard are classified in the same climatic categories as
defined by IEC 60603-7.
_______________
To be published.
– 10 – IEC 60603-7-81:2015 © IEC 2015
6.2 Electrical characteristics
6.2.1 General
Connectors according to this standard shall meet the electrical characteristics specified by
IEC 60603-7-1.
In the following clauses/subclauses, f is the frequency expressed in MHz.
6.2.2 Transfer impedance
In addition to 6.2.1, the transfer impedance of connectors conforming to this standard shall
meet the following requirements.
Conditions:
When tested according to IEC 60512-26-100, Test 26e, mated connectors, terminated with
each cable type (e.g. F/UTP, S/FTP) intended to be used for these connectors shall not show
higher magnitude of transfer impedance as given by formula:
0,3
All types: ≤ 0,05f Ω from 1 MHz to 10 MHz
≤ 0,01f Ω from 10 MHz to 80 MHz.
6.3 Transmission characteristics
6.3.1 General
Compliance to this standard in respect to transmission characteristics, is determined
according to specific test methods described in test group EP, see Table 1. The
interoperability of connectors compliant to this standard shall be demonstrated by testing the
fixed connectors with the full range of free connectors according to IEC 60512-28-100.
Compliance to this standard in respect to the alien (exogenous) crosstalk is determined
according to specific test methods described in IEC 60512-25-9.
All transmission performance requirements apply between the reference planes specified in
2nd edition of IEC 60512-28-100.
NOTE At the date of issue of this standard, the test method was under consideration.
st nd
1 edition of IEC 60512-28-100 will be updated to 2 000 MHz as 2 edition.
6.3.2 Insertion loss
Conditions:
IEC 60512, test 28a.
Mated connectors.
All pairs: ≤ 0,02 f dB, from 1 MHz to 500 MHz.
All pairs: ≤ 0,00649 f + 0,000605 f dB, from 500 MHz to 2 000 MH.
Whenever the formula results in a value less than 0,1 dB, the requirement shall revert
to 0,1 dB.
6.3.3 Return loss
Conditions.
IEC 60512, test 28 b.
Mated connectors.
All pairs: ≥ 72-20 log (f) dB from 1 MHz to 2 000 MHz.
Whenever the formula results in a value greater than 30 dB, the requirement shall
revert to 30 dB.
Whenever the formula results in a value less than 12 dB, the requirement shall revert
to 12 dB.
6.3.4 Propagation delay
All pairs: ≤ 2,5 ns.
The propagation delay test does not need to be performed, since it is assumed that
connectors comply by design.
6.3.5 Delay skew
All pair combinations: ≤ 1,25 ns.
This characteristic is calculated from the individual propagation delay measurements
and, as with propagation delay (6.3.4), it is assumed that connectors comply by
design.
6.3.6 NEXT loss
Conditions.
IEC 60512, test 28c.
Mated connectors.
All pair combinations: ≥ 94-20 log (f) dB from 1 MHz to 250 MHz.
(unless limits are specified by IEC 60512-28-100 ED 2)
All pair combinations: ≥ 46,04 -30 log(f/250) dB from 250 MHz to 500 MHz.
(unless limits are specified by IEC 60512-28-100 ED 2)
All pair combinations: ≥ 37,0-40 log(f/500) dB from 500 MHz to 2 000 MHz.
(unless limits are specified by IEC 60512-28-100 ED 2)
Whenever the formula results in a value greater than 80 dB, the requirement shall
revert to 80 dB.
6.3.7 Power sum NEXT loss
This characteristic is given for information only.
Conditions:
Mated connectors.
− NEXT
n ik
PS NEXT = −10log 10
k ∑
i=1,i≠k
All pairs: ≥ 90-2 log (f) dB from 1 MHz to 250 MHz.
All pairs: ≥ 42,04-30 log (f/250) dB from 250 MHz to 500 MHz.
All pairs: ≥ 33,0-40 log (f/500) dB from 500 MHz to 2 000 MHz.
– 12 – IEC 60603-7-81:2015 © IEC 2015
This characteristic is calculated from the individual FEXT loss measurements and
connector compliance is achieved by compliance to the FEXT loss requirements
(6.3.8).
6.3.8 FEXT Loss
Conditions:
IEC 60512, test 28 d.
Mated connectors.
All pair combinations: ≥ 83,1-20 log (f) dB from 1 MHz to 2 000 MHz.
Whenever the formula results in a value greater than 80 dB, the requirement shall
revert to 80 dB.
6.3.9 Power sum FEXT loss
This characteristic is given for information only.
Conditions:
Mated connectors.
−FEXT
n ik
PS FEXT = −10log 10
k ∑
i=1,i≠k
All pairs: ≥ 80,1-20 log (f) dB from 1 MHz to 2 000 MHz.
This characteristic is calculated from the individual FEXT loss measurements and
connector compliance is achieved by compliance to the FEXT loss requirements
(6.3.8).
6.3.10 Transverse conversion loss
Conditions:
IEC 60512, test 28 f.
Mated connectors
All pairs: ≥ 74-20 log (f) dB from 1 MHz to 2 000 MHz.
Whenever the formula results in a value greater than 40 dB, the requirement shall
revert to 40 dB.
6.3.11 Transverse conversion transfer loss
Conditions:
IEC 60512, test 28 g.
Mated connectors.
All pairs: ≥ 78-20 log (f) dB from 1 MHz to 2 000 MHz.
Whenever the formula results in a value greater than 40 dB, the requirement shall
revert to 40 dB.
6.3.12 Coupling attenuation
Conditions:
IEC 62153-4-15 for coupling attenuation with triaxial cell.
Mated connectors, terminated with each cable construction type intended to be allowed
for these connectors.
All types: > 85–20log (f) dB, from 30 MHz to 2 000 MHz
Whenever the formula results in a value greater than 85 dB, the requirement shall
revert to 85 dB.
The coupling attenuation requirement is assumed to be fulfilled when the transfer impedance
and unbalance attenuation (transverse conversion loss and transverse conversion transfer
loss) requirements are met on the full bandwidth.
6.3.13 Power sum alien (exogenous) NEXT
Conditions:
IEC 60512, test 25i.
Mated connectors.
−ANEXT
kij
N 4
PS ANEXT = −10log 10
k
j=1 i=1
All pairs: ≥ 135,5-20log(f) dB from 1 MHz to 2 000 MHz.
Whenever the formula results in a value greater than 84 dB, the requirement shall revert to
84 dB.
The coupling attenuation requirement is assumed to be fulfilled when the transfer impedance
and unbalance attenuation (transverse conversion loss and transverse conversion transfer
loss) requirements are met on the full bandwidth.
6.3.14 Power sum alien (exogenous) FEXT
Conditions:
IEC 60512, test 25i.
Mated connectors.
−AFEXT
kij
N 4
PS AFEXT = −10log 10
k
j =1 i=1
All pairs: ≥ 131-20log(f) dB from 1 MHz to 2 000 MHz.
Whenever the formula results in a value greater than 84 dB, the requirement shall revert to
84 dB.
The PS AFEXT requirements are fulfilled when the coupling attenuation is verified and it is
10 dB better than the PS ANEXT and the PS AACR-F minimum requirements.
6.3.15 Mechanical
Connectors according to this standard shall conform to the mechanical characteristics
specified by IEC 60603-7-1.
6.3.16 Pin assignment
The pin and pair grouping assignment of Figure 9 of 6.2 of IEC 60603-7:2008 applies.
– 14 – IEC 60603-7-81:2015 © IEC 2015
7 Tests and test schedule
7.1 General
See 7.1 of IEC 60603-7:2008, and the introduction to this standard.
7.2 Arrangement for contact resistance test
See also 7.2 of IEC 60603-7:2008.
7.3 Arrangement for vibration test
See also 7.3 of IEC 60603-7:2008.
7.4 Test procedures and measuring methods
See 7.4 of IEC 60603-7:2008.
7.5 Preconditioning
See 7.5 of IEC 60603-7:2008.
7.6 Wiring and mounting of specimens
7.6.1 Wiring
Wiring of these connectors shall take into account the wire and cable diameter of the cables
defined in the IEC 61156 series as given in the manufacturer’s specification.
7.6.2 Mounting
Shall be in accordance with 7.6.2 of IEC 60603-7:2008.
8 Test schedules
8.1 General
The test conditions required shall not be less than those listed in Clause 6.
8.2 Basic (minimum) test schedule
Not applicable.
8.3 Full test schedule
8.3.1 General
In addition to the test schedule of IEC 60603-7-1, one further group of two sets of mated
connectors is required for group EP, which is shown in Table 1. The free connectors for group
EP shall additionally meet the requirements of IEC 60512-28-100 and IEC 60512-25-9.
Additional sets of connectors are required for the alien (exogenous) NEXT and FEXT (EP10
and EP11) measurements according to IEC 60512-25-9.
8.3.2 Test group P preliminary
All the test group specimens shall be subjected to the preliminary group P of IEC 60603-7 and
the preliminary group P of IEC 60603-7-1.
8.3.3 Test group AP
See 7.7.2.3 of IEC 60603-7:2008 and 7.7.2.3 of IEC 60603-7-1:2011.
8.3.4 Test group BP
See 7.7.2.4 of IEC 60603-7:2008 and 7.7.2.4 of IEC 60603-7-1:2011.
8.3.5 Test group CP
See 7.7.2.5 of IEC 60603-7:2008 and 7.7.2.5 of IEC 60603-7-1:2011.
8.3.6 Test group DP
See 7.7.2.6 of IEC 60603-7:2008 and 7.7.2.6 of IEC 60603-7-1:2011.
8.3.7 Test group EP
Table 1 – Test Group EP
Test Measurement to be performed
Title IEC 60512 Severity or Title IEC 60512 Requirements
Test No. condition of Test No.
test
EP1 All pairs, one Insertion loss Test 28a Per 6.3.2
direction
EP2 All pairs, both NEXT loss Test 28c Per 6.3.6
directions, (pair
to pair)
EP3 All pairs, both Return loss Test 28b Per 6.3.3
directions
EP4 All pairs, both FEXT loss Test 28d Per 6.3.8
directions, (pair
to pair)
EP5 All pairs, both TCL Test 28f Per 6.3.10
directions
EP6 All pairs, both TCTL Test 28g Per 6.3.11
directions
EP7 Input to output Measurement Millivolt level Test 2a 6.4.5 of
resistance points as method IEC 60603-
defined in 6.4.5 7:2008
of IEC 60603-
7:2008
All input/output
connector paths
EP8 Resistance Measurement Millivolt level Test 2a 6.4.6 of
unbalance points as method IEC 60603-
defined in 6.4.6 7:2008
of IEC 60603-
7:2008
All input/output
connector path
combinations
EP9 All pairs, both PS ANEXT Test 25i Per 6.3.13
directions
EP10 All pairs, both PS AFEXT Test 25i Per 6.3.14
directions
EP11 All pairs Transfer Test 26e Per 6.2.2
Impedance
– 16 – IEC 60603-7-81:2015 © IEC 2015
8.3.8 Test group FP
See 7.7.2.8 of IEC 60603-7:2008.
8.3.9 Test group GP
See 7.7.2.9 of IEC 60603-7-1:2011.
Bibliography
IEC 60603-7-2:2010, Connectors for electronic equipment – Part 7-2: Detail specification for
8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to
100 MHz
IEC 60603-7-3:2010, Connectors for electronic equipment – Part 7-3: Detail specification for
8-way, shielded, free and fixed connectors, for data transmission with frequencies up to
100 MHz
IEC 60603-7-4:2010, Connectors for electronic equipment – Part 7-4: Detail specification for
8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to
250 MHz
IEC 60603-7-41:2010, Connectors for electronic equipment – Part 7-41: Detail specification
for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up
to 500 MHz
IEC 60603-7-51:2010, Connectors for electronic equipment – Part 7-51: Detail specification
for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to
500 MHz
IEC 60603-7-7:2010, Connectors for electronic equipment – Part 7-7: Detail specification for
8-way, shielded, free and fixed connectors for data transmission with frequencies up to
600 MHz
IEC 60603-7-71:2010, Connectors for electronic equipment – Part 7-71: Detail specification
for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to
1 000 MHz
IEC 62153-4-12, Metallic communication cable test methods – Part 4-12: Electromagnetic
Compatibility (EMC) – Coupling attenuation or screening attenuation of connecting hardware
– Absorbing clamp method
NOTE The above document is defined up to 1 GHz. IEC TC46/WG5 is requested to revise it to 2 GHz.
ISO/IEC TR 11801-9901, Information technology – Generic cabling for customer premises –
Part 9901: Guidance for balanced cabling in support of at least 40 Gbit/s data transmission
____________
– 18 – IEC 60603-7-81:2015 © IEC 2015
SOMMAIRE
AVANT-PROPOS . 20
INTRODUCTION . 22
1 Domaine d’application . 24
2 Références normatives . 24
3 Termes et définitions . 25
4 Extrémités du câble et connexions internes – Embases et fiches . 25
5 Calibres . 25
6 Caractéristiques . 25
6.1 Généralités . 25
6.1.1 Vue d'ensemble . 25
6.1.2 Affectation de groupement des broches et des paires . 25
6.1.3 Classification en catégories climatiques . 26
6.2 Caractéristiques électriques . 26
6.2.1 Généralités . 26
6.2.2 Impédance de transfert . 26
6.3 Caractéristiques de transmission . 26
6.3.1 Généralités . 26
6.3.2 Perte d’insertion . 26
6.3.3 Affaiblissement de réflexion . 27
6.3.4 Retard de propagation . 27
6.3.5 Différence des temps de propagation . 27
6.3.6 Perte par paradiaphonie (NEXT: near-end crosstalk) . 27
6.3.7 Perte par paradiaphonie cumulée . 27
6.3.8 Perte par télédiaphonie (FEXT: far-end crosstalk). 28
6.3.9 Perte par télédiaphonie cumulée. 28
6.3.10 Perte de conversion transverse . 28
6.3.11 Perte de transfert de conversion transverse . 28
6.3.12 Affaiblissement de couplage . 29
6.3.13 Puissance de paradiaphonie exogène cumulée . 29
6.3.14 Puissance de télédiaphonie exogène cumulée . 29
6.3.15 Mécanique . 30
6.3.16 Affectation des broches . 30
7 Essais et programme d'essais . 30
7.1 Généralités . 30
7.2 Disposition pour les essais de résistance de contact . 30
7.3 Disposition pour les essais de vibrations . 30
7.4 Procédures d'essai et méthodes de mesure . 30
7.5 Préconditionnement . 30
7.6 Câblage et montage des éprouvettes . 30
7.6.1 Câblage . 30
7.6.2 Montage . 30
8 Programmes d’essais . 30
8.1 Généralités . 30
8.2 Programme d’essais de base (minimal) . 30
8.3 Programme d’essais complet . 31
8.3.1 Généralités . 31
8.3.2 Groupe d'essais préliminaires P . 31
8.3.3 Groupe d'essais AP . 31
8.3.4 Groupe d'essais BP . 31
8.3.5 Groupe d'essais CP . 31
8.3.6 Groupe d'essais DP . 31
8.3.7 Groupe d'essais EP . 32
8.3.8 Groupe d'essais FP . 33
8.3.9 Groupe d'essais GP . 33
Bibliographie . 34
Tableau 1 – Groupe d'essais EP . 32
– 20 – IEC 60603-7-81:2015 © IEC 2015
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
CONNECTEURS POUR ÉQUIPEMENTS ÉLECTRONIQU
...