IEC 60068-2-67:1995
(Main)Environmental testing - Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components
Environmental testing - Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components
IEC 60068-2-67:1995 Provides a standard test procedure for the purpose of evaluating, in an accelerated manner, the resistance of small electrotechnical products, primarily non-hermetically sealed components, to the deteriorative effect of damp heat. The test is not intended to evaluate external effects such as corrosion and deformation.
Essai d'environnement - Partie 2-67: Essais - Essai Cy: Essai continu de chaleur humide, essai accéléré applicable en premier lieu aux composants
IEC 60068-2-67:1995 Fournit une méthode d'essai normalisée permettant d'évaluer, de manière accélérée, la résistance de produits électrotechniques de petites dimensions, principalement de composants non hermétiquement fermés, à la dégradation par la chaleur humide.
General Information
- Status
- Published
- Publication Date
- 01-Jul-2019
- Technical Committee
- TC 104 - Environmental conditions, classification and methods of test
- Drafting Committee
- MT 16 - TC 104/MT 16
- Current Stage
- PPUB - Publication issued
- Start Date
- 13-Dec-1995
- Completion Date
- 31-Jul-1995
Relations
- Effective Date
- 05-Sep-2023
Overview
IEC 60068-2-67:1995 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies a test method for evaluating the durability of small electrotechnical components-primarily non-hermetically sealed-to damp heat. This accelerated, steady-state damp heat test (Test Cy) is designed to assess the resistance of components to the deteriorative effects caused by prolonged exposure to high temperature and humidity environments. The standard defines procedures for testing under controlled temperature and humidity conditions, providing valuable insights into component reliability in humid climates and demanding applications.
This test is crucial for manufacturers, designers, and quality assurance engineers who want to ensure the long-term performance of electrical and electronic components exposed to moist and warm conditions without focusing on external corrosion or physical deformation.
Key Topics
Test Purpose: To evaluate the resistance of electronic components, especially small, non-hermetically sealed products, against damp heat deterioration under accelerated testing.
Test Conditions:
- Temperature: 85°C (±2°C)
- Relative Humidity: 85% (±5%)
- Duration options: 168, 504, 1000, or 2000 hours depending on severity level
- Electrical biasing of the specimen is usually applied during the test.
Test Environment Setup:
- Use of a specialized test chamber capable of maintaining steady temperature and humidity with tight tolerances.
- Prevention of condensation on specimens to avoid unintended test outcomes.
- Use of distilled or deionized water with specified resistivity and pH for humidification to avoid contamination or damage.
- Continuous drainage of water to maintain test integrity.
Test Procedure:
- Preconditioning and initial measurements, including visual, dimensional, and functional checks.
- Controlled ramp-up to specified temperature and humidity.
- Maintaining steady state damp heat conditions for the defined duration.
- Intermediate and final measurements to assess changes.
- Recovery period and evaluation of component performance post-exposure.
Limitations: The test focuses on internal degradation mechanisms such as moisture absorption by plastics and moisture ingress along terminals, and it does not cover external corrosion or physical deformation effects.
Applications
IEC 60068-2-67:1995 is widely used in industries requiring high reliability of electrotechnical components under harsh environmental conditions, including:
Electronics Manufacturing: Ensuring component robustness in consumer electronics, industrial controls, and instrumentation exposed to humid environments.
Automotive Industry: Validating components that operate in high humidity and elevated temperature conditions within vehicles.
Telecommunications: Testing of sensitive components in base stations and communication devices expected to endure climatic stress.
Aerospace and Defense: Assessing the stability of electronic fittings in environments prone to heat and moisture exposure.
Medical Devices: Verifying the endurance of non-hermetic components in medical equipment subject to sterilization and humidification cycles.
This standardized test aids product design improvements, quality control processes, and compliance with environmental durability requirements, supporting reliable product performance and customer satisfaction.
Related Standards
For a comprehensive environmental testing approach, the following related IEC standards complement IEC 60068-2-67:
IEC 60068-1: General and guidance for environmental testing - offers foundational principles and procedures applicable to all environmental tests.
IEC 60068-2-30: Tests - Test Db: Damp heat, cyclic (12 + 12-hour cycle) - focuses on cyclic damp heat rather than steady state.
IEC 60068-2-78: Tests - Test Cab: Damp heat, steady state - longer duration steady-state damp heat testing often intended for larger products.
ISO 16750-4: Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads, which includes damp heat tests applicable to automotive components.
IEC 60068-3: Background information on environmental testing that supports method selection and interpretation of results.
Aligning IEC 60068-2-67:1995 with these and other standards enables organizations to develop robust environmental test programs that address diverse stress factors impacting electrical and electronic components.
Keywords: IEC 60068-2-67, damp heat test, environmental testing, electrotechnical components, accelerated testing, steady-state damp heat, humidity resistance, temperature and humidity testing, IEC environmental standards, component durability, electronic component testing, test chamber, electrotechnical product reliability.
IEC 60068-2-67:1995 - Environmental testing - Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components
IEC 60068-2-67:1995+AMD1:2019 CSV - Environmental testing - Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components Released:7/2/2019 Isbn:9782832271407
Frequently Asked Questions
IEC 60068-2-67:1995 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Environmental testing - Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components". This standard covers: IEC 60068-2-67:1995 Provides a standard test procedure for the purpose of evaluating, in an accelerated manner, the resistance of small electrotechnical products, primarily non-hermetically sealed components, to the deteriorative effect of damp heat. The test is not intended to evaluate external effects such as corrosion and deformation.
IEC 60068-2-67:1995 Provides a standard test procedure for the purpose of evaluating, in an accelerated manner, the resistance of small electrotechnical products, primarily non-hermetically sealed components, to the deteriorative effect of damp heat. The test is not intended to evaluate external effects such as corrosion and deformation.
IEC 60068-2-67:1995 is classified under the following ICS (International Classification for Standards) categories: 19.040 - Environmental testing. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 60068-2-67:1995 has the following relationships with other standards: It is inter standard links to IEC 60068-2-67:1995/AMD1:2019. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase IEC 60068-2-67:1995 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of IEC standards.
Standards Content (Sample)
NORME CEI
INTERNATIONALE
IEC
60068-2-67
INTERNATIONAL
Première édition
STANDARD
First edition
1995-12
PUBLICATION FONDAMENTALE DE SÉCURITÉ
BASIC SAFETY PUBLICATION
Essais d’environnement –
Partie 2-67:
Essais – Essai Cy: Essai continu
de chaleur humide, essai accéléré applicable
en premier lieu aux composants
Environmental testing –
Part 2-67:
Tests – Test Cy: Damp heat, steady state,
accelerated test primarily intended for components
Numéro de référence
Reference number
CEI/IEC 60068-2-67:1995
Copyright © 1993 IEC, Geneva, Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de
référence, texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou
remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
NORME CEI
INTERNATIONALE
IEC
60068-2-67
INTERNATIONAL
Première édition
STANDARD
First edition
1995-12
BASIC SAFETY PUBLICATION
PUBLICATION FONDAMENTALE DE SÉCURITÉ
Essais d’environnement –
Partie 2-67:
Essais – Essai Cy: Essai continu
de chaleur humide, essai accéléré applicable
en premier lieu aux composants
Environmental testing –
Part 2-67:
Tests – Test Cy: Damp heat, steady state,
accelerated test primarily intended for components
CODE PRIX
J
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
Pour prix, voir catalogue en vigueur
– 2 – 68-2-67 © CEI:1995
SOMMAIRE
Pages
AVANT-PROPOS. 4
Articles
1 Domaine d’application. 6
2 Description . 6
3 Description de l'appareillage d'essai . 6
4 Sévérités . 8
5 Préconditionnement . 10
6 Mesures initiales. 10
7 Epreuve. 10
8 Mesures intermédiaires. 12
9 Reprise. 12
10 Mesures finales . 12
11 Renseignements que doit donner la spécification particulière . 12
Annexes
A Signification physique de l'essai. 14
B Appareillage d’essai et manipulation . 16
68-2-67 © IEC:1995 – 3 –
CONTENTS
Page
FOREWORD . 5
Clause
1 Scope. 7
2 General description . 7
3 Description of test apparatus . 7
4 Severities . 9
5 Pre-conditioning . 11
6 Initial measurements. 11
7 Testing . 11
8 Intermediate measurements. 13
9 Recovery. 13
10 Final measurements . 13
11 Information to be given in the relevant specification. 13
ANNEXES
A Physical significance of the test . 15
B Test apparatus and handling. 17
– 4 – 68-2-67 © CEI:1995
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
_________
ESSAIS D’ENVIRONNEMENT –
Partie 2: Essais – Essai Cy: Essai continu de chaleur humide,
essai accéléré applicable en premier lieu aux composants
AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation
composée de l’ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l’électricité et de l’électronique. A cet effet, la CEI, entre autres activités, publie des Normes
internationales. Leur élaboration est confiée à des comités d’études, aux travaux desquels tout Comité
national intéressé par le sujet traité peut participer. Les organisations internationales, gouvernementales et
non gouvernementales, en liaison avec la CEI, participent également aux travaux. La CEI collabore
étroitement avec l’Organisation Internationale de Normalisation (ISO), selon des conditions fixées par accord
entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant des questions techniques, représentent, dans la
mesure du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux
intéressés sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales, ils sont publiés
comme normes, rapports techniques ou guides et agréés comme tels par les Comités nationaux.
4) Dans le but d’encourager l’unification internationale, les Comités nationaux de la CEI s’engagent à appliquer
de façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa
responsabilité n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La norme internationale CEI 68-2-67 a été établie par le sous-comité 50B: Essais climatiques,
du comité d’études 50 de la CEI: Essais d’environnement.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
50B/360/FDIS 50B/373/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l’approbation de cette norme.
Elle a le statut d’une publication fondamentale de sécurité conformément au Guide CEI 104.
La CEI 68 comprend les parties suivantes, présentées sous le titre général: Essais
d’environnement.
– Première partie: Généralités et guide
– Deuxième partie: Essais
– Troisième partie: Informations de base
– Quatrième partie: Renseignements destinés aux rédacteurs de spécifications –
Résumés d’essais
– Partie 5: Guide pour la rédaction des méthodes d’essais
Les annexes A et B sont données uniquement à titre d’information.
68-2-67 © IEC:1995 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
_________
ENVIRONMENTAL TESTING –
Part 2: Tests – Test Cy: Damp heat, steady state,
accelerated test primarily intended for components
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization
comprising all national electrotechnical committees (IEC National Committees). The object to the IEC is to
promote international cooperation on all questions concerning standardization in the electrical and electronic
fields. To this end and in addition to other activities, the IEC publishes International Standards. Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt
with may participate in this preparatory work. International, governmental and non-governmental organizations
liaising with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on technical matters, express as nearly as possible an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the
form of standards, technical reports or guides and they are accepted by the National Committees in that
sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the
subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 68-2-67 has been prepared by sub-committee 50B: Climatic tests,
of IEC technical committee 50: Environmental testing.
The text of this standard is based on the following documents:
FDIS Report on voting
50B/360/FDIS 50B/373/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
It has the status of a basic safety publication in accordance with IEC Guide 104.
IEC 68 consists of the following parts, under the general title: Environmental testing.
– Part 1: General and guidance
– Part 2: Tests
– Part 3: Background information
– Part 4: Information for specification writers – Test summaries
– Part 5: Guide to drafting of test methods
Annexes A and B are for information only.
– 6 – 68-2-67 © CEI:1995
ESSAIS D'ENVIRONNEMENT –
Partie 2: Essais – Essai Cy: Essai continu de chaleur humide,
essai accéléré applicable en premier lieu aux composants
1 Domaine d’application
La présente Norme internationale a pour objet de fournir une méthode d'essai normalisée
permettant d'évaluer, de manière accélérée, la résistance de produits électrotechniques de
petites dimensions, principalement de composants non hermétiquement fermés, à la
dégradation par la chaleur humide.
L'essai n'a pas pour but d'évaluer les effets externes tels que la corrosion et la déformation.
2 Description générale
Dans cet essai, le spécimen est soumis à de très hauts niveaux de chaleur humide non saturée
pendant une période relativement longue.
Une polarisation électrique est habituellement appliquée.
L'essai fournit un certain nombre de durées préférentielles à une humidité relative de 85 % et à
une température de 85 °C.
Dans le cas de composants encapsulés dans du plastique, la dégradation résulte de
l'absorption de vapeur d'eau par le plastique et la pénétration d'humidité le long des
connexions.
3 Description de l'appareillage d'essai
3.1 Chambre d'essai
La chambre d'essai doit être construite de façon telle que:
a) elle puisse produire la température et l'humidité relative prévues dans le tableau 1 sans
interruption pendant une période au moins égale à 2 000 h;
b) elle puisse assurer le pilotage de la température et de l'humidité relative pendant
l'épreuve ainsi que la montée vers et la descente depuis les conditions d'essai spécifiées;
c) la température et l'humidité de la chambre puissent être pilotées à l'aide de capteurs
situés dans l'espace de travail et/ou d’autres endroits donnant les mêmes résultats;
d) toute eau venant de l'espace de travail soit évacuée de façon continue, et non réutilisée;
e) l'eau de condensation ne puisse pas tomber sur le spécimen;
f) les matériaux utilisés pour la construction n’entraînent pas une corrosion significative du
spécimen ou la dégradation de la qualité de l'eau d'humidification (voir l’article B.1).
La tolérance de ±2 °C sur la température a pour but de tenir compte des erreurs absolues de
mesure, des fluctuations de la température à l'intérieur de la chambre, en un point quelconque,
et des variations entre deux points quelconques de l'espace de travail.
68-2-67 © IEC:1995 – 7 –
ENVIRONMENTAL TESTING –
Part 2: Tests – Test Cy: Damp heat, steady state,
accelerated test primarily intended for components
1 Scope
This International Standard provides a standard test procedure for the purpose of evaluating, in
an accelerated manner, the resistance of small electrotechnical products, primarily non-
hermetically sealed components, to the deteriorative effect of damp heat.
The test is not intended to evaluate external effects such as corrosion and deformation.
2 General description
In this test the specimen is subjected to very high levels of unsaturated damp heat for a
relatively long period.
Electrical bias is usually applied.
The test provides a number of preferred durations at a relative humidity of 85 % and a
temperature of 85 °C.
In the case of plastic encapsulated components degradation results from absorption of water-
vapour by the plastic and penetration of moisture along terminals.
3 Description of test apparatus
3.1 The test chamber
The chamber shall be so constructed that:
a) it can produce the temperature and relative humidity given in table 1 for a minimum
period of 2 000 h without interruption;
b) it is capable of providing controlled conditions of temperature and relative humidity during
testing, and the ramp-up to and ramp-down from specified test conditions;
c) the temperature and humidity of the chamber can be monitored by means of sensing
devices located in the working space and/or other areas giving the same results;
d) any water shall be continuously drained from the working space and not re-used;
e) condensed water is not allowed to fall on the specimen;
f) the materials used in the construction shall not cause any significant corrosion of the
specimen, or degradation of the quality of the humidifying water (see clause B.1).
The temperature tolerance of ±2 °C is intended to take account of absolute errors in the
measurement, fluctuations of the chamber temperature at any point and variations between any
two points within the working space.
– 8 – 68-2-67 © CEI:1995
Toutefois, dans le but de maintenir l'humidité relative à l'intérieur de la tolérance spécifiée
de ±5 %, il est aussi nécessaire de maintenir la différence entre deux points quelconques de
l'espace de travail (à tout moment) à l'intérieur de limites plus serrées.
La tolérance sur l'humidité relative spécifiée sera dépassée si les différences de température
excèdent 1,5 °C. Il est aussi nécessaire de maintenir à une valeur similaire les variations de
température à court terme dues à la régulation du dispositif de chauffage de la chambre.
Il convient que le spécimen ne gêne pas de façon significative la circulation de l'air.
Aucune condensation ne doit se former à aucun moment sur le spécimen pendant l'essai.
3.2 Eau d'humidification
On doit utiliser de l'eau distillée ou désionisée. L'eau doit avoir une résistivité d'au moins
0,5 MΩcm, à 23 °C. La valeur du pH doit être comprise entre 6,0 et 7,2 à 23 °C.
Toutes les parties internes de la chambre doivent être nettoyées avant que l'eau ne soit mise
dans l'humidificateur. Un guide pour le nettoyage est donné à l’article B.3.
Le gé
...
IEC 60068-2-67 ®
Edition 1.1 2019-07
CONSOLIDATED VERSION
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
BASIC SAFETY PUBLICATION
PUBLICATION FONDAMENTALE DE SÉCURITÉ
Environmental testing –
Part 2-67: Tests – Test Cy: Damp heat, steady state, accelerated test primarily
intended for components
Essais d’environnement –
Partie 2-67: Essais – Essai Cy: Essai continu de chaleur humide, essai accéléré
applicable en premier lieu aux composants
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.
IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé info@iec.ch
CH-1211 Geneva 20 www.iec.ch
Switzerland
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigendum or an amendment might have been published.
IEC publications search - webstore.iec.ch/advsearchform Electropedia - www.electropedia.org
The advanced search enables to find IEC publications by a The world's leading online dictionary on electrotechnology,
variety of criteria (reference number, text, technical containing more than 22 000 terminological entries in English
committee,…). It also gives information on projects, replaced and French, with equivalent terms in 16 additional languages.
and withdrawn publications. Also known as the International Electrotechnical Vocabulary
(IEV) online.
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published IEC Glossary - std.iec.ch/glossary
details all new publications released. Available online and 67 000 electrotechnical terminology entries in English and
once a month by email. French extracted from the Terms and Definitions clause of
IEC publications issued since 2002. Some entries have been
IEC Customer Service Centre - webstore.iec.ch/csc collected from earlier publications of IEC TC 37, 77, 86 and
If you wish to give us your feedback on this publication or CISPR.
need further assistance, please contact the Customer Service
Centre: sales@iec.ch.
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.
Recherche de publications IEC - Electropedia - www.electropedia.org
webstore.iec.ch/advsearchform Le premier dictionnaire d'électrotechnologie en ligne au
La recherche avancée permet de trouver des publications IEC monde, avec plus de 22 000 articles terminologiques en
en utilisant différents critères (numéro de référence, texte, anglais et en français, ainsi que les termes équivalents dans
comité d’études,…). Elle donne aussi des informations sur les 16 langues additionnelles. Egalement appelé Vocabulaire
projets et les publications remplacées ou retirées. Electrotechnique International (IEV) en ligne.
IEC Just Published - webstore.iec.ch/justpublished Glossaire IEC - std.iec.ch/glossary
Restez informé sur les nouvelles publications IEC. Just 67 000 entrées terminologiques électrotechniques, en anglais
Published détaille les nouvelles publications parues. et en français, extraites des articles Termes et Définitions des
Disponible en ligne et une fois par mois par email. publications IEC parues depuis 2002. Plus certaines entrées
antérieures extraites des publications des CE 37, 77, 86 et
Service Clients - webstore.iec.ch/csc CISPR de l'IEC.
Si vous désirez nous donner des commentaires sur cette
publication ou si vous avez des questions contactez-nous:
sales@iec.ch.
IEC 60068-2-67 ®
Edition 1.1 2019-07
CONSOLIDATED VERSION
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colourcolour
insinsiidede
BASIC SAFETY PUBLICATION
PUBLICATION FONDAMENTALE DE SÉCURITÉ
Environmental testing –
Part 2-67: Tests – Test Cy: Damp heat, steady state, accelerated test primarily
intended for components
Essais d’environnement –
Partie 2-67: Essais – Essai Cy: Essai continu de chaleur humide, essai accéléré
applicable en premier lieu aux composants
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 00.000 ISBN 978-2-8322-7140-7
IEC 60068-2-67 ®
Edition 1.1 2019-07
CONSOLIDATED VERSION
REDLINE VERSION
VERSION REDLINE
colour
inside
BASIC SAFETY PUBLICATION
PUBLICATION FONDAMENTALE DE SÉCURITÉ
Environmental testing –
Part 2-67: Tests – Test Cy: Damp heat, steady state, accelerated test primarily
intended for components
Essais d’environnement –
Partie 2-67: Essais – Essai Cy: Essai continu de chaleur humide, essai accéléré
applicable en premier lieu aux composants
– 2 – IEC 60068-2-67:1995+AMD1:2019 CSV
© IEC 2019
CONTENTS
FOREWORD . 3
1 Scope . 5
2 General description . 5
3 Description of test apparatus . 5
4 Severities . 6
5 Preconditioning. 6
6 Initial measurements . 7
7 Testing . 7
8 Intermediate measurements . 7
9 Recovery . 8
10 Final measurements . 8
11 Information to be given in the relevant specification . 8
Annex A (informative) Physical significance of the test . 9
Annex B (Informative) Test apparatus and handling . 10
Table 1 – Severities . 6
© IEC 2019
INTERNATIONAL ELECTROTECHNICAL COMMISSION
–––––––––
ENVIRONMENTAL TESTING –
Part 2-67: Tests – Test Cy: Damp heat, steady state,
accelerated test primarily intended for components
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
This consolidated version of the official IEC Standard and its amendment has been
prepared for user convenience.
IEC 60068-2-67 edition 1.1 contains the first edition (1995-12) [documents 50B/360/FDIS
and 50B/373/RVD] and its amendment 1 (2019-07) [documents 104/831/FDIS and 104/838/
RVD].
In this Redline version, a vertical line in the margin shows where the technical content
is modified by amendment 1. Additions are in green text, deletions are in strikethrough
red text. A separate Final version with all changes accepted is available in this
publication.
– 4 – IEC 60068-2-67:1995+AMD1:2019 CSV
© IEC 2019
International Standard IEC 60068-2-67 has been prepared by subcommittee 50B: Climatic
tests, of IEC technical committee 50: Environmental testing.
It has the status of a basic safety publication in accordance with IEC Guide 104.
IEC 60068 consists of the following parts, under the general title: Environmental testing.
– Part 1: General and guidance
– Part 2: Tests
– Part 3: Background information
– Part 4: Information for specification writers – Test summaries
– Part 5: Guide to drafting of test methods
Annexes A and B are for information only.
The committee has decided that the contents of the base publication and its amendment will
remain unchanged until the stability date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
© IEC 2019
ENVIRONMENTAL TESTING –
Part 2-67: Tests – Test Cy: Damp heat, steady state,
accelerated test primarily intended for components
1 Scope
This International Standard provides a standard test procedure for the purpose of evaluating,
in an accelerated manner, the resistance of small electrotechnical products, primarily non
hermetically sealed components, to the deteriorative effect of damp heat.
The test is not intended to evaluate external effects such as corrosion and deformation.
2 General description
In this test the specimen is subjected to very high levels of unsaturated damp heat for a
relatively long period.
Electrical bias is usually applied.
The test provides a number of preferred durations at a relative humidity of 85 % and a
temperature of 85 °C.
In the case of plastic encapsulated components degradation results from absorption of water-
vapour by the plastic and penetration of moisture along terminals.
3 Description of test apparatus
3.1 The test chamber
The chamber shall be so constructed that:
a) it can produce the temperature and relative humidity given in table 1 for a minimum
period of 2 000 h without interruption;
b) it is capable of providing controlled conditions of temperature and relative humidity
during testing, and the ramp-up to and ramp-down from specified test conditions;
c) the temperature and humidity of the chamber can be monitored by means of sensing
devices located in the working space and/or other areas giving the same results;
d) any water shall be continuously drained from the working space and not re-used;
e) condensed water is not allowed to fall on the specimen;
f) the materials used in the construction shall not cause any significant corrosion of the
specimen, or degradation of the quality of the humidifying water (see clause B.1).
The temperature tolerance of ±2 °C is intended to take account of absolute errors in the
measurement, fluctuations of the chamber temperature at any point and variations between
any two points within the working space.
However, in order to maintain the relative humidity within the specified tolerance of ±5 %, it is
necessary to keep the difference between any two points in the working space (at any instant)
within narrower limits.
– 6 – IEC 60068-2-67:1995+AMD1:2019 CSV
© IEC 2019
The specified humidity tolerance will be exceeded if such temperature differences exceed
1,5 °C. It is also necessary to restrict the short-term temperature fluctuations due to cycling of
the chamber heater to a similar value.
The specimen should not significantly impede the air flow.
Condensation shall not be allowed to form on the specimen at any time during the test.
3.2 The humidifying water
Distilled or deionised water shall be used. The water shall have a resistivity of not less than
0,5 MΩcm at 23 °C. The pH value shall be between 6,0 and 7,2 at 23 °C.
Before the water is placed in the humidifier, all internal parts of the chamber shall be cleaned.
Guidance on cleaning is given in clause B.3.
The humidifier and/or test chamber shall be purged of all water after each test.
Distilled or deionised water shall be used. The water resistivity shall be between 2 000 Ωm to
500 Ωm corresponding to a conductivity between 5 µS/cm to 20 µS/cm at +23 °C. Before the
water is placed in the humidifier or storage tank of the chamber, all internal parts of the
chamber shall be cleaned. Guidance on cleaning is given in Clause B.3.
NOTE A conductivity lower than 5 µS/cm might harm the humidifier system. A conductivity higher than 20 µS/cm
can cause limescale or other mineral deposits to form on parts of the humidifier system or specimen.
4 Severities
The test severity, defined by the duration, shall be defined in the relevant specification.
Unless otherwise specified, one of the durations given in table 1 shall be used.
Table 1 – Severities
3) 4)
Temperature Relative Duration
humidity h
1) 2)
°C % I II III IV
85 85 168 504 1 000 2 000
1)
Tolerance for temperature: ± 2 °C in the chamber working space
2)
Tolerance for relative humidity: ± 5 %
+5
3)
Tolerance for duration: %
4)
Definition of duration: see 7.4.2
NOTE – It is not recommended that a test should be restarted; however, if it is required to subject the specimen to
a longer duration than 2 000 h then the test shall be recommenced in accordance with the requirements of clause
7. The test shall be recommenced within 96 h of the end of the ramp-down period of the previous test.
During the interval between the tests the specimen shall be held under standard atmospheric conditions for
measurement and tests, unless otherwise specified in the relevant specification.
5 Preconditioning
The relevant specification may prescribe preconditioning.
© IEC 2019
6 Initial measurements
The specimen shall be submitted to the visual, dimensional and functional checks prescribed
by the relevant specification.
7 Testing
7.1 With the chamber and specimen at the laboratory conditions of temperature, pressure
and humidity, the specimen shall be installed in the working space in the chamber.
7.2 The specimen shall not be subjected to radiant heat from the heaters or the chamber
wall.
If required by the relevant specification, a specific mounting structure shall be used. The heat
conductivity and the thermal capacity of the mounting fixtures shall be sufficiently low so that
for all practical purposes the specimen is thermally isolated.
Care shall be exercised in the choice of mounting structure and mounting fixture materials to
minimize the effects of contamination and to minimize degradation due to corrosion and other
mechanisms (see clause B.1).
7.3 If required by the relevant specification the specimen shall have a bias voltage applied
during testing. Guidance on the application of bias is given in clause B.2.
The bias voltage (or bias voltage cycle) shall be applied to the specimen when the
temperature and the relative humidity have reached the stable state and continue until the
specimen is under recovery conditions.
7.4 Test cycle
7.4.1 The temperature and relative humidity of the chamber shall be raised to their
appropriate values. During this period the temperature and the relative humidity shall not
exceed the specified value. Condensed water is not allowed on the specimen at any time
during the test cycle. Stabilization of temperature and humidity shall take place within 3 h.
7.4.2 The temperature and relative humidity shall be maintained within the prescribed limits
for a duration as specified in the relevant specification. The duration shall commence as soon
as the conditions have stabilized.
7.4.3 At the end of the specified duration, the chamber temperature and relative humidity
shall be restored to standard atmospheric conditions for measurement and tests in not less
than 1 h and not more than 4 h.
During this period, the temperature and the relative humidity shall not exceed the specified
value. The bias shall be maintained during this period.
7.4.4 On completion of the cooling period the specimen shall be subjected to the recovery
procedure.
8 Intermediate measurements
The relevant specification may require electrical and/or mechanical checks during testing.
– 8 – IEC 60068-2-67:1995+AMD1:2019 CSV
© IEC 2019
If it is required to make intermediate measurements, the relevant specification shall define the
measurements and period(s) during testing after which they shall be carried out. The
measurements shall not cause any change to the test conditions.
Measurements preceded by recovery which would require removal of the specimen from the
chamber are not permissible during testing.
9 Recovery
Upon completion of testing the specimen shall be allowed to recover. Unless otherwise
specified in the relevant specification, recovery shall be not less than 2 h and not more than
24 h at standard atmospheric conditions for measurement and tests.
10 Final measurements
The specimen shall be submitted to the visual, dimensional, and functional checks prescribed
by the relevant specification.
11 Information to be given in the relevant specification
When this test is included in a relevant specification, the following details shall be given, in so
far as they are applicable. The relevant specification shall supply information as required in
the clauses listed below, paying particular attention to the items marked with an asterisk (*),
as this information is always required.
Clause/subclause
a) Test severity (duration)*. . 4
b) Atmospheric conditions between tests (if not standard) . 4
c) Preconditioning* . 5
d) Initial measurements*. . 6
e) Specific mounting structures . 7.2
f) Bias voltage . 7.3 and B.2
g) Intermediate measurements. . 8
h) Recovery*. . 9
I) Final measurements* . 10
© IEC 2019
Annex A
(informative)
Physical significance of the test
A.1 The acceleration of the penetration of water-vapour into the specimen is the most
important physical factor in the accelerated damp heat test. The acceleration is due to the
difference in partial pressure of water-vapour between the inside of a non hermetically sealed
specimen and the test environment.
A.2 In the first instance this test was applied to accelerate the corrosion of aluminium
metallization in both integrated circuits and other semiconductor devices in plastic
encapsulation. However, when considering the application of the test to other products it is
important that the failure mode or modes are determined, and the appropriate degradation
process and test severity selected in response to each failure mode.
– 10 – IEC 60068-2-67:1995+AMD1:2019 CSV
© IEC 2019
Annex B
(Informative)
Test apparatus and handling
B.1 Selection of materials
Care exercised in the choice of materials to be used in the chamber will minimize the release
of contamination and the degradation due to corrosion and other mechanisms under the
combined conditions of humidity and temperature defined in the test. Suitable materials are:
stainless steel, glass, ceramic, and others which resist corrosion.
B.2 Bias voltage
Bias voltage is defined as that voltage which is applied for test purposes in order to enhance
the effects of humidity. It is not necessarily concerned with the normal functioning of the
specimen.
The bias should be applied in accordance with the following guidelines, which are given in
order of decreasing importance:
a) The temperature increase of defined locations within and at the surface of the specimen
should be less than 2 °C with respect to the nominal temperature of the working space.
b) Care should be exercised when choosing the voltage to both promote hydrolysis and to
limit self-heating of the specimen, since this will affect the penetration and/or absorption of
moisture. Where it is not possible to prevent significant self-heating with continuous bias
applied, it is recommended that the bias should be applied intermittently. Unless otherwise
specified, the periods should be 3 h off followed by 1 h on. The sequence should
commence with the bias off.
c) Precautions should be taken to limit energy dissipation due to faulty conditions.
NOTE – Applying bias to the specimen at a constant relative humidity enhances the moisture-induced effects. On
the other hand, bias induces power dissipation which may lead to an effect which is contrary to the intention of the
test since it reduces the relative humidity of the critical locations by increasing the local temperature.
B.3 Cleaning
Cleaning of the chamber and all internal fixtures (racks, etc.) placed in the chamber is
essential.
The test chamber and internal fixtures may be cleaned with diluted laboratory detergent using
a soft brush, and rinsed with distilled or deionized water. It is recommended that the chamber
be cleaned prior to each test.
It is recommended that gloves and face masks be used as a precaution against the
contamination of the test chamber and of the internal fixtures when cleaning and that the
equipment be operated in a suitably clean area.
Unless otherwise specified, the specimen should be tested in the “as received” condition and
following normal handling. Tests on a specimen which has been specially cleaned prior to the
test may not give an indication of effects which occur in service.
__________
– 12 – IEC 60068-2-67:1995+AMD1:2019 CSV
© IEC 2019
SOMMAIRE
AVANT-PROPOS . 13
1 Domaine d’application . 15
2 Description générale . 15
3 Description de l'appareillage d'essai . 15
4 Sévérités . 16
5 Préconditionnement . 17
6 Mesures initiales . 17
7 Epreuve . 17
8 Mesures intermédiaires . 18
9 Reprise . 18
10 Mesures finales . 18
11 Renseignements que doit donner la spécification particulière . 18
Annex A (informative) Signification physique de l'essai . 19
Annex B (Informative) Appareillage d'essai et manipulation . 20
Tableau 1 – Sévérités . 16
© IEC 2019
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
_________
ESSAIS D’ENVIRONNEMENT –
Partie 2-67: Essais – Essai Cy: Essai continu de chaleur humide,
essai accéléré applicable en premier lieu aux composants
AVANT-PROPOS
1) La Commission Electrotechnique Internationale (IEC) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de l’IEC). L’IEC a pour
objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines
de l'électricité et de l'électronique. A cet effet, l’IEC – entre autres activités – publie des Normes
internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au
public (PAS) et des Guides (ci-après dénommés "Publication(s) de l’IEC"). Leur élaboration est confiée à des
comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec l’IEC, participent
également aux travaux. L’IEC collabore étroitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de l’IEC concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de l’IEC
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de l’IEC se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de l’IEC. Tous les efforts raisonnables sont entrepris afin que l’IEC
s'assure de l'exactitude du contenu technique de ses publications; l’IEC ne peut pas être tenue responsable de
l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de l’IEC s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de l’IEC dans leurs publications nationales
et régionales. Toutes divergences entre toutes Publications de l’IEC et toutes publications nationales ou
régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) L’IEC elle-même ne fournit aucune attestation de conformité. Des organismes de certification indépendants
fournissent des services d'évaluation de conformité et, dans certains secteurs, accèdent aux marques de
conformité de l’IEC. L’IEC n'est responsable d'aucun des services effectués par les organismes de certification
indépendants.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à l’IEC, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de l’IEC, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de l’IEC ou de
toute autre Publication de l’IEC, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de l’IEC peuvent faire
l’objet de droits de brevet. L’IEC ne saurait être tenue pour responsable de ne pas avoir identifié de tels droits
de brevets et de ne pas avoir signalé leur existence.
Cette version consolidée de la Norme IEC officielle et de son amendement a été
préparée pour la commodité de l'utilisateur.
L'IEC 60068-2-67 édition 1.1 contient la première édition (1995-12) [documents 50B/360/
FDIS et 50B/373/RVD] et son amendement 1 (2012-02) [documents 104/831/FDIS et
104/838/RVD].
Dans cette version Redline, une ligne verticale dans la marge indique où le contenu
technique est modifié par l'amendement 1. Les ajouts sont en vert, les suppressions
sont en rouge, barrées. Une version Finale avec toutes les modifications acceptées est
disponible dans cette publication.
– 14 – IEC 60068-2-67:1995+AMD1:2019 CSV
© IEC 2019
La norme internationale IEC 68-2-67 a été établie par le sous-comité 50B: Essais climatiques,
du comité d’études 50 de l'IEC: Essais d’environnement.
Elle a le statut d’une publication fondamentale de sécurité conformément au Guide IEC 104.
L'IEC 68 comprend les parties suivantes, présentées sous le titre général:
Essais d’environnement.
– Première partie: Généralités et guide
– Deuxième partie: Essais
– Troisième partie: Informations de base
– Quatrième partie: Renseignements destinés aux rédacteurs de spécifications –
Résumés d’essais
– Partie 5: Guide pour la rédaction des méthodes d’essais
Les annexes A et B sont données uniquement à titre d’information.
Le comité a décidé que le contenu de la publication de base et de son amendement ne sera
pas modifié avant la date de stabilité indiquée sur le site web de l’IEC sous
"http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date,
la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
IMPORTANT – Le logo "colour inside" qui se trouve sur la page de couverture de cette
publication indique qu'elle contient des couleurs qui sont considérées comme utiles à
une bonne compréhension de son contenu. Les utilisateurs devraient, par conséquent,
imprimer cette publication en utilisant une imprimante couleur.
© IEC 2019
ESSAIS D'ENVIRONNEMENT –
Partie 2-67: Essais – Essai Cy: Essai continu de chaleur humide,
essai accéléré applicable en premier lieu aux composants
1 Domaine d’application
La présente Norme internationale a pour objet de fournir une méthode d'essai normalisée
permettant d'évaluer, de manière accélérée, la résistance de produits électrotechniques de
petites dimensions, principalement de composants non hermétiquement fermés, à la
dégradation par la chaleur humide.
L'essai n'a pas pour but d'évaluer les effets externes tels que la corrosion et la déformation.
2 Description générale
Dans cet essai, le spécimen est soumis à de très hauts niveaux de chaleur humide non
saturée pendant une période relativement longue.
Une polarisation électrique est habituellement appliquée.
L'essai fournit un certain nombre de durées préférentielles à une humidité relative de 85 % et
à une température de 85 °C.
Dans le cas de composants encapsulés dans du plastique, la dégradation résulte de
l'absorption de vapeur d'eau par le plastique et la pénétration d'humidité le long des
connexions.
3 Description de l'appareillage d'essai
3.1 Chambre d'essai
La chambre d'essai doit être construite de façon telle que:
a) elle puisse produire la température et l'humidité relative prévues dans le tableau 1 sans
interruption pendant une période au moins égale à 2 000 h;
b) elle puisse assurer le pilotage de la température et de l'humidité relative pendant
l'épreuve ainsi que la montée vers et la descente depuis les conditions d'essai spécifiées;
c) la température et l'humidité de la chambre puissent être pilotées à l'aide de capteurs
situés dans l'espace de travail et/ou d’autres endroits donnant les mêmes résultats;
d) toute eau venant de l'espace de travail soit évacuée de façon continue, et non
réutilisée;
e) l'eau de condensation ne puisse pas tomber sur le spécimen;
f) les matériaux utilisés pour la construction n’entraînent pas une corrosion significative
du spécimen ou la dégradation de la qualité de l'eau d'humidification (voir l’article B.1).
La tolérance de ±2 °C sur la température a pour but de tenir compte des erreurs absolues de
mesure, des fluctuations de la température à l'intérieur de la chambre, en un point
quelconque, et des variations entre deux points quelconques de l'espace de travail.
– 16 – IEC 60068-2-67:1995+AMD1:2019 CSV
© IEC 2019
Toutefois, dans le but de maintenir l'humidité relative à l'intérieur de la tolérance spécifiée
de ±5 %, il est aussi nécessaire de maintenir la différence entre deux points quelconques de
l'espace de travail (à tout moment) à l'intérieur de limites plus serrées.
La tolérance sur l'humidité relative spécifiée sera dépassée si les différences de température
excèdent 1,5 °C. Il est aussi nécessaire de maintenir à une valeur similaire les variations de
température à court terme dues à la régulation du dispositif de chauffage de la chambre.
Il convient que le spécimen ne gêne pas de façon significative la circulation de l'air.
Aucune condensation ne doit se former à aucun moment sur le spécimen pendant l'essai.
3.2 Eau d'humidification
On doit utiliser de l'eau distillée ou désionisée. L'eau doit avoir une résistivité d'au moins
0,5 MΩcm, à 23 °C. La valeur du pH doit être comprise entre 6,0 et 7,2 à 23 °C.
Toutes les parties internes de la chambre doivent être nettoyées avant que l'eau ne soit mise
dans l'humidificateur. Un guide pour le nettoyage est donné à l’article B.3.
Le générateur de vapeur et/ou la chambre d'essai doivent être purgés de toute leur eau après
chaque essai.
On doit utiliser de l'eau distillée ou désionisée. La résistivité de l'eau doit être comprise entre
2 000 Ωm et 500 Ωm, correspondant à une conductivité comprise entre 5 µS/cm et 20 µS/cm
à +23 °C. Toutes les parties internes de la chambre doivent être nettoyées avant que l'eau ne
soit mise dans l'humidificateur ou dans la cuve de stockage de la chambre. Des
recommandations pour le nettoyage sont données à l’Article B.3.
NOTE Une conductivité inférieure à 5 µS/cm pourrait endommager le système d’humidificateur. Une conductivité
supérieure à 20 µS/cm peut entraîner un dépôt de calcaire ou la formation d'autres dépôts de minéraux sur les
parties du système d’humidificateur ou du spécimen.
4 Sévérités
La sévérité de l'essai, définie par la durée, doit être prescrite par la spécification particulière.
Sauf prescription contraire dans la spécification particulière, l'une des durées citées dans le
tableau 1 doit être utilisée.
Tableau 1 – Sévérités
3) 4)
Température Humidité relative Durée
h
1) 2)
°C % I II III IV
85 85 168 504 1 000 2 000
1)
Tolérance sur la température: ± 2 °C dans l’espace de travail de la chambre d’essai
2)
Tolérance sur l’humidité relative: ± 5 %
+5
3)
Tolérance sur la durée: %
4)
Définition de la durée: voir 7.4.2
NOTE – Il n’est pas recommandé de recommencer un essai; toutefois, s'il est demandé de soumettre le spécimen
à une durée plus longue que 2 000 h, l'essai doit alors être recommencé en accord avec les prescriptions de
l'article 7. L'essai doit être recommencé dans les 96 h qui suivent la fin de la période de descente de l'essai
précédent.
Pendant l'intervalle de temps séparant les essais, le spécimen doit être maintenu sous les conditions
atmosphériques normales pour les mesures et les essais sauf prescription contraire dans la spécification
particulière.
© IEC 2019
5 Préconditionnement
La spécification particulière peut prescrire un préconditionnement.
6 Mesures initiales
Le spécimen doit être soumis aux vérifications visuelles, dimensionnelles et fonctionnelles
prescrites par la spécification particulière.
7 Epreuve
7.1 La chambre et le spécimen étant aux conditions de température, de pression
atmosphérique et d'humidité du laboratoire, le spécimen doit être installé dans l'espace de
travail de la chambre.
7.2 Le spécimen ne doit pas être soumis à la chaleur rayonnante des éléments chauffants
ou de la paroi de la chambre.
Si cela est prescrit par la spécification particulière, une structure de fixation spécifique doit
être utilisée. La conductivité et la capacité thermiques des structures de fixation doivent être
suffisamment faibles pour que le spécimen soit thermiquement isolé dans tous les cas
d'applications pratiques.
Les matériaux pour les structures de fixation doivent être choisis de manière à réduire au
minimum les effets de la contamination et la dégradation due à la corrosion et aux autres
mécanismes (voir article B.1).
7.3 Si cela est prescrit par la spécification particulière, le spécimen doit être soumis à une
tension de polarisation pendant l'épreuve. Un guide pour l'application de la polarisation est
donné à l’article B.2.
La tension de polarisation ou le cycle de tension de polarisation doit être appliqué au
spécimen lorsque l'humidité relative a atteint la stabilité et jusqu'à ce que le spécimen soit
dans les conditions de reprise.
7.4 Cycle d’essai
7.4.1 La température et l'humidité relative de la chambre doivent être élevées jusqu'à leurs
valeurs appropriées. Pendant cette période, la température et l'humidité relative ne doivent
pas dépasser les valeurs spécifiées. La condensation d’eau sur le spécimen, quelle que soit
la période de l’essai, n’est pas autorisée. La stabilisation de la température et de l'humidité
doit être atteinte en moins de 3 h.
7.4.2 La température et l'humidité relative doivent être maintenues dans les limites prescrites
pendant la durée indiquée dans la spécification particulière. La durée doit commencer dès
que les conditions sont stabilisées.
7.4.3 A la fin de la durée spécifiée, la température de la chambre et l'humidité relative doivent
être ramenées dans les conditions atmosphériques normales pour les mesures et les essais
en un temps pouvant aller de 1 h au minimum à 4 h au maximum.
Pendant cette période, la température et l'humidité relative ne doivent pas dépasser les
valeurs spécifiées. La polarisation doit être normalement maintenue pendant cette période.
– 18 – IEC 60068-2-67:1995+AMD1:2019 CSV
© IEC 2019
7.4.4 A la fin de la période de refroidissement, le spécimen doit être soumis à la procédure
de reprise.
8 Mesures intermédiaires
La spécification particulière peut exiger des vérifications électriques et/ou mécaniques
pendant l'épreuve.
...














Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...