EN IEC 60115-4-10:2026
(Main)Fixed resistors for use in electronic equipment - Part 4-10: Blank detail specification: Power resistors with axial leads for through-hole assembly on circuit boards (THT), for general electronic equipment, classification level G
- Abstract
This part of IEC 60115 is applicable to fixed power resistors with axial leads for through hole assembly (THT) on circuit boards for use in electronic equipment. The document is applicable to the drafting of detail specifications for fixed low-power film resistors with leads classified to level G, which is defined in IEC 60115-1:2020, 3.4 for general electronic equipment, typically operated under benign or moderate environmental conditions, where the major requirement is function. Examples for level G include consumer products and telecommunication user terminals. This detail specification is based upon the blank detail specification IEC 60115-4-10:202X. This detail specification establishes test schedules and performance requirements permitting the quality assessment of the resistors covered herein according to the quality assessment procedures prescribed by IEC 60115-1:2020, Annex Q.
- Status
- Published
- Publication Date
- 13-Aug-2026
- Technical Committee
- CLC/TC 40XB - Resistors
- Drafting Committee
- CLC/TC 40XB - Resistors
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 14-Aug-2026
- Due Date
- 27-Feb-2027
- Completion Date
- 27-Feb-2027
EN IEC 60115-4-10:2026 is a CENELEC European Standard for blank detail specifications for fixed power resistors with axial leads for through-hole assembly (THT) on circuit boards. It sets the structure, ratings, tests, performance requirements and quality assessment method to be used when drafting a product-specific detail specification for level G resistors in general electronic equipment. In practice, it is the document a resistor maker, spec writer, or quality engineer uses to define and qualify these parts for benign or moderate environments where function is the main requirement.
What does EN IEC 60115-4-10:2026 specify?
EN IEC 60115-4-10:2026 applies to fixed power resistors with axial leads for THT on circuit boards and is intended for drafting detail specifications for level G products. Level G is the application class for general electronic equipment, including examples such as consumer products and telecommunication user terminals.
EN IEC 60115-4-10:2026 is organized as a template-style standard. It starts with an introduction for the detail-specification writer, then covers scope, normative references, terms and definitions, characteristics and ratings, tests and test severities, performance requirements, marking, packaging and ordering information, additional information, and quality assessment procedures.
| Annex | What it covers |
|---|---|
| Annex A | Symbols and abbreviated terms used in the specification |
| Annex B | Reference examples for visual examination |
| Annex X | Cross-reference to the prior revision of the blank detail specification |
What are the key requirements of EN IEC 60115-4-10:2026?
EN IEC 60115-4-10:2026 gives the framework for defining the resistor style, its allowable dimensions, its ratings, the tests it must pass, and the acceptance criteria used for quality assessment. The point is not only to describe the component, but to make the resulting detail specification usable for qualification and production control.
Product definition and ratings
EN IEC 60115-4-10:2026 requires the detail specification to identify the resistor style and its dimensional envelope using Figure 1 and Table 1. It also allows additional dimensional controls such as lead eccentricity and coating extension on the leads, if those are needed for the product family.
This matters because axial-leaded parts can vary in body size, lead geometry and coating coverage. If these features are not stated clearly, inspection and fit on the board become inconsistent.
The ratings section ties the product to climatic categories, rated dissipation, insulation voltage and the resistance range/tolerance/TCR combinations allowed for approval. A derating curve is used for dissipation above the rated temperature of 70 °C, so the product definition stays linked to the real thermal operating limit.
Tests and performance requirements
EN IEC 60115-4-10:2026 requires a test programme covering electrical, mechanical, climatic and assembly-related stresses. Clause 5 includes resistance, temperature coefficient of resistance (TCR), temperature rise, endurance, short-term overload, ESD, visual examination, dimensional checking, robustness of terminations and body, vibration, shock or bump, rapid change of temperature, climatic sequence, damp heat, solderability with lead-free solder and with SnPb solder, resistance to soldering heat, solvent resistance, insulation resistance, voltage proof, and flammability.
That mix matters in practice because these resistors are intended for board assembly and long-term use, not just bench measurement. The detail specification writer must decide which optional tests apply, and then state the exact severities in the detail specification.
Clause 6 turns those test results into pass/fail criteria. It sets limits for change of resistance, temperature-related resistance shift, temperature rise, solderability, insulation resistance and flammability, and it makes clear that only the parameters specified and tested can be assumed to be within limits.
Inspection, marking and packaging
EN IEC 60115-4-10:2026 requires a 100 % production test for resistance and tolerance, followed by sampling re-inspection to monitor outgoing quality. It also defines separate schedules for initial qualification approval and for ongoing quality conformance inspection.
This is important for buyers and quality teams because the standard is written for a zero-defect approach. The document uses sampling control, but it does not rely on historic AQL wording or on accepting non-conforming specimens inside test groups.
Clause 7 also covers marking, packaging and ordering information. The package and the component marking must be unambiguous, and the ordering information needs at least the detail-specification number, style, nominal resistance, tolerance, TCR, and delivery or packaging method.
What terms does EN IEC 60115-4-10:2026 define?
EN IEC 60115-4-10:2026 uses the definitions from IEC 60115-1 and IEC 60115-4, and Annex A fixes the key symbols and abbreviations used throughout the document.
- LCT - Lower category temperature, the low end of the climatic category used for environmental and TCR-related testing.
- UCT - Upper category temperature, the high end of the climatic category used for endurance, derating and climatic tests.
- MET - Maximum element temperature, the highest element temperature used to define allowable temperature rise.
- ESD - Electrostatic discharge, the electrical stress applied in the ESD test.
- HBM - Human Body Model, the discharge model used for the ESD test.
- SPC - Statistical process control, a manufacturing control method that can support dimensional control in place of some inspection.
- CoC - Certificate of Conformity, the conformity declaration used within a quality assessment system.
Who uses EN IEC 60115-4-10:2026?
EN IEC 60115-4-10:2026 is used by resistor manufacturers, detail-specification writers, quality managers, test laboratories and certification bodies. It is also relevant to buyers and design engineers who need to specify or approve fixed power resistors for THT assembly on printed circuit boards.
It is especially relevant in electronics where level G components are used in consumer products and telecommunication user terminals. In those settings, the document helps teams agree on the part geometry, thermal rating, test regime, packaging and acceptance criteria before production or qualification starts.
What changed in EN IEC 60115-4-10:2026 from the previous edition?
EN IEC 60115-4-10:2026 supersedes EN 140201:1996. The underlying IEC edition also introduces a new structure and a technical revision that brings application-based product classification from IEC 60115-1:2020, additional dimensional options for lead eccentricity and coating extension, tabulated resistance ranges linked to TCR and tolerance, solderability testing for both lead-free and SnPb solder, optional ESD, solvent and flammability testing, stability classes, detailed visual acceptance criteria, packaging inspection, side-by-side qualification and quality conformance schedules, and a zero-defect quality assessment approach.
Which standards are used with EN IEC 60115-4-10:2026?
EN IEC 60115-4-10:2026 relies on these named references:
| Standard | What it contributes |
|---|---|
| IEC 60062 | Marking codes for resistors and capacitors |
| IEC 60063 | Preferred number series for resistors and capacitors |
| IEC 60115-1:2020 | Generic requirements and the main measurement, test and quality-assessment framework |
| IEC 60115-4:2022 | Sectional specification for power resistors and the shared test/visual criteria |
| IEC 60286-1 | Tape packaging for axial-leaded components |
| IEC 60294 | Measurement of dimensions for cylindrical components with axial terminations |
| IEC 60301 | Preferred diameters of wire terminations |
| IEC 61760-1 | THT soldering process guidance |
| IEC 61193-2:2007 | Sampling plans for inspection of electronic components and packages |
The document also points to Annex Q of IEC 60115-1 for the quality assessment procedures used with these resistors.
What does the EN IEC 60115-4-10:2026 document contain?
EN IEC 60115-4-10:2026 contains a detailed set of figures, tables and test schedules that a drafter can use to build a product-specific specification without inventing the structure from scratch. Figures 1 to 4 cover the outline, lead eccentricity, coating extension and derating curve, while Tables 1 to 10 define dimensions, climatic categories, ratings, resistance ranges and performance limits.
Tables 11 and 12 are the main qualification and quality conformance schedules. They show the test groups, the order of testing, and the key conditions to be stated in a detail specification.
Annex A provides the symbols and abbreviations used in formulas and test descriptions. Annex B gives the visual reference framework, and Annex X gives a cross-reference to the earlier revision structure.
Relations
- Effective Date
- 12-Aug-2025
- Effective Date
- 25-Aug-2026
- Effective Date
- 03-Feb-2026
- Refers
EN 60115-1:2023 - Fixed resistors for use in electronic equipment - Part 1: Generic specification - Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Refers
EN 60294:2012 - Measurement of the dimensions of a cylindrical component with axial terminations - Effective Date
- 03-Feb-2026
- Effective Date
- 01-Oct-2024
Frequently Asked Questions
EN IEC 60115-4-10:2026 is a standard published by CLC. Its full title is "Fixed resistors for use in electronic equipment - Part 4-10: Blank detail specification: Power resistors with axial leads for through-hole assembly on circuit boards (THT), for general electronic equipment, classification level G". This standard covers: This part of IEC 60115 is applicable to fixed power resistors with axial leads for through hole assembly (THT) on circuit boards for use in electronic equipment. The document is applicable to the drafting of detail specifications for fixed low-power film resistors with leads classified to level G, which is defined in IEC 60115-1:2020, 3.4 for general electronic equipment, typically operated under benign or moderate environmental conditions, where the major requirement is function. Examples for level G include consumer products and telecommunication user terminals. This detail specification is based upon the blank detail specification IEC 60115-4-10:202X. This detail specification establishes test schedules and performance requirements permitting the quality assessment of the resistors covered herein according to the quality assessment procedures prescribed by IEC 60115-1:2020, Annex Q.
This part of IEC 60115 is applicable to fixed power resistors with axial leads for through hole assembly (THT) on circuit boards for use in electronic equipment. The document is applicable to the drafting of detail specifications for fixed low-power film resistors with leads classified to level G, which is defined in IEC 60115-1:2020, 3.4 for general electronic equipment, typically operated under benign or moderate environmental conditions, where the major requirement is function. Examples for level G include consumer products and telecommunication user terminals. This detail specification is based upon the blank detail specification IEC 60115-4-10:202X. This detail specification establishes test schedules and performance requirements permitting the quality assessment of the resistors covered herein according to the quality assessment procedures prescribed by IEC 60115-1:2020, Annex Q.
EN IEC 60115-4-10:2026 is classified under the following ICS (International Classification for Standards) categories: 31.040.10 - Fixed resistors. The ICS classification helps identify the subject area and facilitates finding related standards.
EN IEC 60115-4-10:2026 has the following relationships with other standards: It is inter standard links to EN 140201:1996, EN IEC 61760-1:2026, EN 60301:2012, EN 60115-1:2023, EN IEC 61760-1:2020, EN 60063:2015, EN 60286-1:2017, EN 60062:2016, EN 61193-2:2007, EN IEC 60115-4:2026, EN 60294:2012, EN IEC 60115-4-10:2026/A11:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN IEC 60115-4-10:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Characteristics and ratings
- 4.1 General
- 4.2 Dimensions
- 4.3 Ratings
- 4.4 Resistance range and tolerance on resistance
- 5 Tests and test severities
- 5.1 General
- 5.2 Resistance
- 5.3 Temperature coefficient of resistance
- 5.4 Temperature rise
- 5.5 Endurance at the rated temperature 70 °C
- 5.6 Endurance at other than rated temperature
- 5.7 Short-term overload of power resistors
- 5.8 Electrostatic discharge (ESD) test
- 5.9 Visual examination
- 5.10 Gauging of dimensions
- 5.11 Detail dimensions
- 5.12 Robustness
- 5.13 Shock and vibration
- 5.14 Rapid change of temperature
- 5.15 Climatic sequence
- 5.16 Damp heat, steady state test
- 5.17 Solderability, with lead-free solder
- 5.18 Solderability, with SnPb solder
- 5.19 Resistance to soldering heat
- 5.20 Solvent resistance test
- 5.21 Insulation resistance
- 5.22 Voltage proof
- 5.23 Flammability test
- 6 Performance requirements
- 6.1 General
- 6.2 Limits for change of resistance at tests
- 7.3 Endurance at 7.2 Endurance at 8.1 Short-term 8.5 Electrostatic
- 9.5 Robustness of
- 10.3 Climatic
- 9.4 Robustness of
- 7.1 Endurance at
- 9.11 Vibration
- 9.10 Shock or bump
- 10.1 Rapid change of
- 11.2 Resistance to
- 6.3 Temperature coefficient of resistance
- 6.4 Temperature rise
- 6.5 Visual examination
- 6.6 Solderability
- 6.7 Insulation resistance
- 6.8 Flammability
- 7 Marking, packaging and ordering information
- 7.1 Marking of the component
- 7.2 Packaging
- 7.3 Marking of the packaging
- 7.4 Ordering information
- 8 Additional information
- 8.1 General
- 8.2 Storage and Transportation
- 8.3 Substrate for assembly
- 8.4 Soldering process
- 8.5 Use of cleaning agents or solvents
- 8.6 Coating or potting after assembly
- 9 Quality assessment procedures
- 9.1 General
- 9.2 Qualification approval
- 9.3 Maintenance of a qualification approval
- Annex A
- Annex B
- Annex X
- 1.2 For resistance range, tolerance and temperature
- 1.8 Increased requirements are indicated in the respective
- Bibliography
1 Scope
COMMENT The text of this clause may repeat information already given in some fields of the above title block. Essential information on the special type of components covered by the drafted detail specification may be added, preferably at the place marked with "…".
This detail specification specifies the characteristics and ratings of fixed power resistors with axial leads for through hole assembly (THT) on circuit boards …
The resistors covered herein are classified to level G, as defined in IEC 60115-1:2020, 3.4 for general electronic equipment, typically operated under benign or moderate environmental conditions, where the major requirement is function. Examples for level G include consumer products and telecommunication user terminals.
This detail specification is based upon the blank detail specification IEC 60115-4-10:2023. This detail specification establishes test schedules and performance requirements permitting the quality assessment of the resistors covered herein according to the quality assessment procedures specified by IEC 60115-1:2020, Annex Q.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60062, Marking codes for resistors and capacitors IEC 60063, Preferred number series for resistors and capacitors IEC 60115-1:2020, Fixed resistors for use in electronic equipment – Part 1: Generic specification IEC 60115-4:2022, Fixed resistors for use in electronic equipment – Part 4: Sectional specification: Power resistors for through hole assembly on circuit boards (THT) or for assembly on chassis IEC 60115-4-10:2023, Fixed resistors for use in electronic equipment – Part 4-10: Blank detail specification: Power resistors with axial leads for through-hole assembly on circuit boards (THT), for general electronic equipment, classification level G IEC 60286-1, Packaging of components for automatic handling – Part 1: Tape packaging of components with axial leads on continuous tapes
SIST EN IEC 60115-4-10:2026
IEC 60294, Measurement of the dimensions of a cylindrical component with axial terminations IEC 60301, Preferred diameters of wire terminations of capacitors and resistors IEC 61760-1, Surface mounting technology – Part 1: Standard method for the specification of surface mounting components (SMDs) IEC 61193-2:2007, Quality assessment systems – Part 2: Selection and use of sampling plans for inspection of electronic components and packages
COMMENT 1 The above list of normative references provides an example and needs to be adapted to the actual requirements of the drafted detail specification, indicated by the space marked with "…", which however does not preclude from sorting in proper numerical order.
COMMENT 2 According to the ISO/IEC directives, dated references are required when reference is made to a specific part of the referenced standard and generally should be applied only in such cases. COMMENT 3 It is recommended to update any dated references to the most recent revision of the referenced standard when drafting a detail specification. This involves updating of the dated normative references within the text of the drafted detail specification.
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60115-1 and in IEC 60115-4, as well as the following, apply.
COMMENT Any terms and their respective definitions specifically required for the scope of the drafted detail specification may be inserted in the space marked with "…", using the specified numbering and format. Otherwise, the above statement should be reduced to "For the purposes of this document, the terms and definitions given in IEC 60115-1 and in IEC 60115-4 apply." if no further terms or definitions are required in the drafted detail specification.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- IEC Electropedia: available at https://www.electropedia.org/
- ISO Online browsing platform: available at https://www.iso.org/obp
4 Characteristics and ratings
4.1 General
Various parameters of this component are precisely defined in this specification. Unspecified parameters can vary from one component to another.
4.2 Dimensions
The shape and dimensions of the resistors covered by this specification are shown in Figure 1, with the specific styles and their respective dimensions given in Table 1. Other shapes are permissible within the given dimensions.
SIST EN IEC 60115-4-10:2026
Figure 1 – Outline and dimensions COMMENT 1 See IEC 60115-4:2022, 8.2.1.
COMMENT 2 The details shown in Figure 1 may repeat information already given in some fields of the title block above. Figure 1 in particular needs to define all dimensions intended to be verified by measurements, which generally includes those dimensions to be specified in Table 1.
Table 1 – Styles and dimensions g f Style Dimensions Mass b c d e a D L d l m Metric X Y min mm mm mm mm mg
a Historical style code, for information only.
b the body diameter of the resistor D shall be gauged as specified in IEC 60294, see IEC 60115-4:2022 5.3.11.
the body length of the resistor L shall be gauged and measured according to IEC 60294, see IEC 60115-4:2022, 5.3.11 and 5.3.12 respectively.
d Nominal diameter of the lead-wires d, with permissible tolerances according to IEC 60301. e the minimum lead length l for products in tape packaging according to IEC 60286-1 applies to the length of min the free sections of lead-wire between the resistor body and each tape. For untapped resistors it applies to the length of each lead-wire.
f for information only.
g.
For products which have their origin in the imperial system of units, the inch dimensions can be given additionally for information, presented in square brackets.
COMMENT 3 See IEC 60115-4, 2022, 8.2.2.
COMMENT 4 The metric style designation is the normative designation used in all other places throughout this detail specification, see IEC 60115-4:2022, 4.2.1.1. Column X is an optional column for additional style information, e.g. for traditional alphabetic designations, which generally need to be marked with a respective footnote, e.g. as "Historical style code, for information only".
COMMENT 5 The dimensions for body diameter D, body length L, lead-wire diameter d and minimum free lead length l are given as example based on the requirements for axial leaded resistors with cylindrical body and need min
SIST EN IEC 60115-4-10:2026
to correspond to the dimensions identified in Figure 1. The choice of specified dimensions needs to be adapted to the actual requirements of the drafted detail specification and the shape of products covered therein. The dimensions may be given in the format of nominal values plus tolerance, or by stating permissible minimum and maximum values. Columns for additional dimensions may be inserted as required. COMMENT 6 Column Y represents one or more optional column(s) for the prescription of an additional dimension, e.g. the permissible lead eccentricity and/or the permissible length of excessive coating on the leads, as required. COMMENT 7 The specified minimum lead length should consider the variety of inside tape spacing specified as dimension B by IEC 60286-1, plus the permissible window for the lateral resistor body location, given there as dimension K.
COMMENT 8 The component mass is not intended to be verified by an inspection procedure. It should be given as the maximum mass of a single component and should be marked with a respective footnote as "For information only". The wire terminations of the resistor shall emerge concentrically from the end faces of the resistor body, see IEC 60115-4:2022, 4.2.1.4 with IEC 60115-4:2022, Figure 9. The real eccentricity e, as shown in Figure 2, shall not exceed the limit given in Table 1. For gauging of the lead eccentricity, the effective eccentricity e’ should be used, see IEC 60115-4:2022, 4.2.1.4.
Figure 2 – Lead eccentricity of the wire terminations COMMENT 9 The above paragraph and figure are optional and given as an example for the specification of a permissible lead eccentricity. If this specification is used in the drafted detail specification, a suitable method for gauging and/or measuring of the lead eccentricity needs to be described, e.g. in the respective subclauses of Clause 5. Alternatively, the deletion of this paragraph and figure will result in the need to update the numbering of subsequent figures accordingly.
The resistor shall be properly coated in order to provide a suitable protection against mechanical, electrical and climatic influences, e.g. by means of a conformal lacquer coating. It is typical for such coating to also cover the end faces of the resistor body, which can lead for some amount of excessive coating to spread onto the leads, see IEC 60115-4:2022, 4.2.1.2 and Figure 7. The length of excessive coating c, as shown in Figure 3, shall not exceed the limit given in Table 1.
Figure 3 – Length of excessive coating on the wire terminations COMMENT 10 The above paragraph and figure are optional and given as an example for the specification of a permissible length of excessive coating on the wire terminations. If this specification is used in the drafted detail specification, a suitable method for gauging and/or measuring of the length of excessive coating needs to be described, e.g. in the respective subclauses of Clause 5. Alternatively, the deletion of this paragraph and figure will result in the need to update the numbering of subsequent figures accordingly.
4.3 Ratings
The climatic categories applied in this detail specification are given in Table 2.
SIST EN IEC 60115-4-10:2026
Table 2 – Climatic categories Climatic category LCT / UCT / duration
COMMENT 1 See IEC 60115-4:2022, 8.2.3. and 4.3.
COMMENT 2 Table 2 may be amended with a column showing the key parameter to which different climatic categories are allocated in the purpose of discrimination, e.g. the applied stability classes. The upper category temperature (UCT), which is used for test procedures, should be lower than the maximum element temperature (MET).
Table 3 – Ratings Limiting element Rated Insulation voltage Style X voltage dissipation DC or AC peak DC or AC RMS
P U U 70 max ins W V V
NOTE For insulated resistors, the insulation voltage U is verified with a test duration of one minute. However, ins long time insulation properties can be affected by the influence of moisture, organic material and electrical field across the insulating layer(s). For non-insulated resistors, this is the max voltage against ambient.
COMMENT 3 See IEC 60115-4:2022, 8.2.6, 8.2.7 and 8.2.8.
COMMENT 4 Column X is an optional column for additional information, e.g. an additional rated dissipation at another ambient temperature than the rated temperature 70 °C. Such information should however only be presented, if it is a traditionally well-established information.
COMMENT 5 The insulation voltage shall not be specified lower than the peak value of the AC voltage that can be applied continuously to the resistors and therefore shall not be rated less than U = 1,42 × U . The insulation ins max voltage is not an applicable rating for non-insulated resistors, therefore the entry in this column shall be "n/a" and the note of Table 3 shall be omitted in detail specifications drafted for non-insulated resistors. COMMENT 6 Different sets of ratings may be assigned to variations of another parameter, e.g. climatic categories or stability classes. Then such different sets of ratings should be given in separate tables which need to be clearly assigned to the relevant parameter(s). According to the ISO/IEC directives, such duplicate tables need to be titled with subsequent numbers as required, which will result in the need to update the numbering of subsequent tables accordingly.
The permissible dissipation of resistors covered by this detail specification is the rated dissipation as given in Table 3, which is derated for an ambient temperature above the rated temperature 70 °C according to the diagram in Figure 4.
SIST EN IEC 60115-4-10:2026
Figure 4 – Derating curve for power resistors COMMENT 7 See IEC 60115-4:2022, 8.2.6.
COMMENT 8 The scale of derated dissipation may be given as absolute value in Watt or relative in percent as a fraction of the rated dissipation P .
COMMENT 9 A larger area of operation or permissible temperature rise may be given by the detail specification, provided it includes all the area given in Figure 4.
4.4 Resistance range and tolerance on resistance
Table 4 gives the combinations of temperature coefficient, tolerance on resistance and resistance range which can be approved in climatic category ... / ... / ... according to this detail specification.
COMMENT 1 The above paragraph needs to be adapted to the actual requirements if more than one climatic category is applied in the drafted detail specification, see also COMMENT 5 below. Products from the extent given in Table 4 shall be used for the initial product qualification approval according to 9.2, and for the quality conformance inspection according to 9.3.1. The qualification of resistances below or above the specified resistance ranges is permissible if they fulfil the requirements of the stability class specified for the closest resistance within a
specified range; e.g. resistors of Style ... , ... ⋅ 10 /K, ... %, ... Ω shall fulfil the requirements of stability class ... .
COMMENT 2 The above paragraph should be deleted if individual extension of the approvable resistance ranges is not accepted as being suitable for the scope of the drafted detail specification.
SIST EN IEC 60115-4-10:2026
Table 4 – Temperature coefficients, tolerances and resistance ranges for climatic category ... / ... / ...
Temperature Tolerance on Stability b Style Resistance range E series coefficient resistance class -6 a a
10 /K Code Code % Ω
a Code letters according to IEC 60062.
b Resistance values within the given range are (recommended/required) to be selected from one of the given E series of IEC 60063.
COMMENT 3 See IEC 60115-4:2022, 8.2.4.
COMMENT 4 The column for the prescription of an E series is optional and may be deleted together with its related footnote if the explicit recommendation of or limitation to resistance values of a particular E series is not suitable for the drafted detail specification. If used, the respective footnote needs to describe the recommendation or limitation associated with the given E series.
COMMENT 5 Different sets of resistance ranges may be assigned to different climatic categories, which should be given in separate tables, which then need to be clearly assigned to the respective climatic category. According to the ISO/IEC directives, such duplicate tables need to be titled with subsequent numbers as required, which will result in the need to update the numbering of subsequent tables accordingly. The range of resistors approved in each style, together with the associated temperature coefficient and tolerance, shall be given in the register of approvals, as available for example on the website http://www.iecq.org.
5 Tests and test severities
COMMENT 1 This clause is used to prescribe the severities of all tests demanded by the generic or sectional specification, which have not been specified in these superior specifications. In addition, this clause should be used to prescribe in dedicated subclauses any additional test(s) not specified in the generic and/or sectional specification, and/or additional or increased test severities to those specified in the generic and/or sectional specification, wherever applicable to the scope of the drafted detail specification. COMMENT 2 Owing to the space limitations in Table 12, and to the need for unambiguous and consistent rulings, the prescriptions in this clause need to contain the full relevant information for each specified test. Consequentially, the "Conditions of test" in Table 12 will only quote as much of the prescriptions as is required to provide a suitable overview.
5.1 General
The following tests shall be performed with the specimens kept in any of the following methods, except a special method is explicitly specified in the respective subclause. a) The specimens mounted on a test board according to IEC 60115-4:2022, 5.2.2; or b) The specimens are mounted on a test rack according to IEC 60115-4:2022, 5.2.3; or c) The specimens are unmounted and placed in a suitable fixture for the duration of the test. COMMENT The mounting of specimens, as required by most subclauses 5.xx, normally employs the methods specified in IEC 60115-4:2022, 5.2. In cases special mounting provisions are required for the resistors covered by a drafted detail specification, such provisions should be given in a normative annex to that particular detail specification and be referenced as required.
5.2 Resistance
See IEC 60115-4:2022, 5.3.1, which refers to IEC 60115-1:2020, 6.1.
SIST EN IEC 60115-4-10:2026
5.3 Temperature coefficient of resistance
See IEC 60115-4:2022, 5.3.2, which refers to IEC 60115-1:2020, 6.2.
5.4 Temperature rise
See IEC 60115-4:2022, 5.3.3, which refers to IEC 60115-1:2020, 6.7. The test shall be performed with the specimens mounted on a test board, see 5.1, item a) or on a test rack, see 5.1, item b).
COMMENT The drafted detail specification shall select one of the above alternative mounting prescriptions, unless a special mounting provision apply, see the COMMENT to 5.1.
5.5 Endurance at the rated temperature 70 °C
See IEC 60115-4:2022, 5.3.4, which refers to IEC 60115-1:2020, 7.1. The test shall be performed with the specimens mounted on a test board, see 5.1, item a) or on a test rack, see 5.1, item b).
COMMENT The drafted detail specification shall select one of the above alternative mounting prescriptions, unless a special mounting provision apply, see the COMMENT to 5.1.
See 5.21 for the measurement of the insulation resistance of insulated resistors.
5.6 Endurance at other than rated temperature
5.6.1 Endurance at room temperature
See IEC 60115-4:2022, 5.3.5, which refers to IEC 60115-1:2020, 7.2. The test shall be performed with the specimens mounted on a test board, see 5.1, item a) or on a test rack, see 5.1, item b).
COMMENT The drafted detail specification shall select one of the above alternative mounting prescriptions, unless a special mounting provision apply, see the COMMENT to 5.1.
See 5.21 for the measurement of the insulation resistance of insulated resistors.
5.6.2 Endurance at a maximum temperature: UCT with category dissipation
See IEC 60115-4:2022, 5.3.6, which refers to IEC 60115-1:2020, 7.3. unted on a test board, see 5.1, item a) or on The test shall be performed with the specimens mo a test rack, see 5.1, item b).
COMMENT The drafted detail specification shall select one of the above alternative mounting prescriptions, unless a special mounting provision apply, see the comment to 5.1.
See 5.21 for the measurement of the insulation resistance of insulated resistors.
5.7 Short-term overload of power resistors
5.7.1 Power film resistors
See IEC 60115-4:2022, 5.3.7.1, which refers to IEC 60115-1:2020, 8.1.4.2. The test shall be performed with the specimens mounted on a test board, see 5.1, item a) or mounted on a test rack, see 5.1, item b).
SIST EN IEC 60115-4-10:2026
COMMENT The drafted detail specification shall select one of the above alternative mounting prescriptions, unless a special mounting provision apply, see the COMMENT to 5.1.
...