General Information

Abstract

Specifies the details of the glow-wire test to be applied to test specimens of solid electrical insulating materials or other solid materials for flammability testing to determine the glow-wire flammability index (GWFI). The test results make it possible to provide a relative comparison of various materials according to their ability to extinguish flames on removal of the electrically heated glow-wire and their ability not to produce flaming or glowing particles capable of spreading fire to a specified layer of wrapping tissue placed below. The test method is not valid for determining the flammability of complete items of equipment, since the dimensions of the insulating systems or combustible parts, the design and heat transfer to adjacent metallic or non-metallic parts, etc., greatly influence the flammability of the materials used therein. In addition to this, it is not valid for determining fire behaviour and fire hazard of equipment. Has the status of a basic safety publication in accordance with IEC Guide 104.

Status
Withdrawn
Publication Date
03-Jan-2001
Withdrawal Date
31-Oct-2003
Drafting Committee
IEC/TC 89 - IEC_TC_89
Parallel Committee
IEC/TC 89 - IEC_TC_89
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Dec-2013
Completion Date
01-Dec-2013

Buy Documents

Standard

EN 60695-2-12:2002

English language (10 pages)
Preview
Preview
e-Library read for
1 day

Relations

Effective Date
28-Jan-2023
Effective Date
28-Jan-2023
Effective Date
09-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026

Buy Documents

Standard

EN 60695-2-12:2002

English language (10 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

EN 60695-2-12:2001 is a standard published by CLC. Its full title is "Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods - Glow-wire flammability test method for materials". This standard covers: Specifies the details of the glow-wire test to be applied to test specimens of solid electrical insulating materials or other solid materials for flammability testing to determine the glow-wire flammability index (GWFI). The test results make it possible to provide a relative comparison of various materials according to their ability to extinguish flames on removal of the electrically heated glow-wire and their ability not to produce flaming or glowing particles capable of spreading fire to a specified layer of wrapping tissue placed below. The test method is not valid for determining the flammability of complete items of equipment, since the dimensions of the insulating systems or combustible parts, the design and heat transfer to adjacent metallic or non-metallic parts, etc., greatly influence the flammability of the materials used therein. In addition to this, it is not valid for determining fire behaviour and fire hazard of equipment. Has the status of a basic safety publication in accordance with IEC Guide 104.

Specifies the details of the glow-wire test to be applied to test specimens of solid electrical insulating materials or other solid materials for flammability testing to determine the glow-wire flammability index (GWFI). The test results make it possible to provide a relative comparison of various materials according to their ability to extinguish flames on removal of the electrically heated glow-wire and their ability not to produce flaming or glowing particles capable of spreading fire to a specified layer of wrapping tissue placed below. The test method is not valid for determining the flammability of complete items of equipment, since the dimensions of the insulating systems or combustible parts, the design and heat transfer to adjacent metallic or non-metallic parts, etc., greatly influence the flammability of the materials used therein. In addition to this, it is not valid for determining fire behaviour and fire hazard of equipment. Has the status of a basic safety publication in accordance with IEC Guide 104.

EN 60695-2-12:2001 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products; 29.020 - Electrical engineering in general. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 60695-2-12:2001 has the following relationships with other standards: It is inter standard links to EN 60695-2-1/2:1996, EN 60695-2-12:2010, EN ISO 13943:2000, EN 60695-2-10:2001, EN 60695-2-13:2001, EN 60320-1:2015/A1:2021, EN 60320-1:2001, EN 60269-1:2007/A1:2009, EN 61071:2007, EN 60335-1:2002, EN 60947-6-2:2003, EN 61800-5-1:2003, EN 61810-7:2006, EN 60947-6-2:2003/A1:2007, EN IEC 60320-2-4:2021. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 60695-2-12:2001 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 60695-2-12:2001 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-maj-2002
1DGRPHãþD
SIST EN 60695-2-1/2:1999
Preskušanje požarne ogroženosti - 2-12. del: Preskusne metode z žarilno žico -
Preskušanje vnetljivosti materialov z žarilno žico (IEC 60695-2-12:2000)
Fire hazard testing -- Part 2-12: Glowing/hot-wire based test methods - Glow-wire
flammability test method for materials
Prüfungen zur Beurteilung der Brandgefahr -- Teil 2-12: Prüfungen mit dem Glühdraht -
Prüfung mit dem Glühdraht zur Entflammbarkeit von Werkstoffen
Essais relatifs aux risques du feu -- Partie 2-12: Essais au fil incandescent/chauffant -
Méthode d'essai d'inflammabilité sur matériaux
Ta slovenski standard je istoveten z: EN 60695-2-12:2001
ICS:
13.220.40 Sposobnost vžiga in Ignitability and burning
obnašanje materialov in behaviour of materials and
proizvodov pri gorenju products
29.020 Elektrotehnika na splošno Electrical engineering in
general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---
...