EN 50089:1992/A1:1994
(Amendment)Cast resin partitions for metal enclosed gas-filled high-voltage switchgear and controlgear
- BACK
- 10-Feb-1994
- 30-Sep-1994
- 29.130.10
- CLC/TC 17AC
Cast resin partitions for metal enclosed gas-filled high-voltage switchgear and controlgear
Gießharz-Zwischenwände für metallgekapselte gasgefüllte Hochspannungs-Schaltgeräte und -Schaltanlagen
Cloisons en résine moulée pour l'appareillage sous enveloppe métallique à haute tension sous pression de gaz
Cast resin partitions for metal enclosed gas-filled high-voltage switchgear and controlgear
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Cast resin partitions for metal enclosed gas-filled high-voltage switchgear and controlgearGießharz-Zwischenwände für metallgekapselte gasgefüllte Hochspannungs-Schaltgeräte und -SchaltanlagenCloisons en résine moulée pour l'appareillage sous enveloppe métallique à haute tension sous pression de gazCast resin partitions for metal enclosed gas-filled high-voltage switchgear and controlgear29.130.10Visokonapetostn
...
This May Also Interest You
- Amendment14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 15-Aug-2024
- 29.130.10
- CLC/TC 17AC
IEC 62271-214:2024 specifies requirements for internal arc classification of AC metal-enclosed pole-mounted switchgear and controlgear with rated voltages above 1 kV and up to and including 52 kV with service frequencies up to and including 60 Hz. This document is applicable to three-phase, two-phase and single-phase open terminal equipment for which an internal arc classification is assigned. Enclosures may include fixed and removable components and may be filled with fluid (liquid or gas) to provide insulation. This second edition cancels and replaces the first edition published in 2019. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) indicators positioning update; b) neutral earthing connection of the test circuit for three-phase tests; c) general review for consistency with IEC 62271-200, Ed.3.0:2021.
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-May-2024
- 29.130.10
- CLC/TC 17AC
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for×1 day
- 08-Feb-2024
- 29.130.10
- CLC/TC 17AC
IEC 62271-207:2023 applies to - gas-insulated switchgear (GIS) assemblies - for alternating current of rated voltages above 52 kV complying with IEC 62271-203, and - for direct current of rated voltages including and above 100 kV, - for indoor and outdoor installations, including their supporting structures, - AC metal-enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV complying with IEC 62271-200, ground or floor mounted, intended to be used under seismic conditions, and - AC solid-insulation enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV complying with IEC 62271-201, ground or floor mounted, intended to be used under seismic conditions. This third edition cancels and replaces the second edition published in 2012. This edition constitutes a technical revision. It also cancels and replaces, through merging, the first edition of IEC TS 62271-210 published in 2013. This edition includes the following significant technical changes with respect to the previous edition: a) modification of the minimum voltage rating from 52 kV to above 1 kV in order to include medium voltage equipment previously being within IEC TS 62271-210 scope; b) further harmonisation of qualification procedures with the revised IEEE Std 693-2018 [1], Annex A and Annex P, including 1) matching this document's required response spectra with IEEE Std 693-2018 performance level spectra and IEC TS 62271-210 spectra, 2) addition of a step-by-step procedure assisting the user of this document to select an appropriate seismic qualification level combining seismic integrity with cost-effective design, 3) addition of analytical earthquake component combination techniques, and 4) reference to publicly available accelerograms specially developed to match the IEEE Std 693-2018 spectra for testing and analysis purposes, since this document and IEC TS 62271-210 spectra are identical in shape with IEEE Std 693 spectra. c) various enhancements of test procedures; d) addition of minimum contents for seismic qualification reports; e) scope extended to cover DC GIS including and above 100 kV.
- Standard38 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-Dec-2023
- 29.130.10
- CLC/TC 17AC
IEC 62271-103:2021 is applicable to three-phase, alternating current switches and switch-disconnectors for their switching function, having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV up to and including 52 kV and for rated frequencies from 162/3 Hz up to and including 60 Hz. This document is also applicable to single-pole switches used on three-phase systems. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - this document has been aligned with IEC 62271-1:2017 and IEC 62271-102:2018; - clarifications regarding the behaviour of the switch during breaking tests regarding current interruption and restrikes have been added; - conditions of the switch after making and breaking tests have been clarified; - a new informative Annex B intended to provide guidance for the calculation of Ief1 and Ief2 has been added; - new rules for the combination of 50 Hz and 60 Hz switching tests have been defined and a new table (Table 7) has been added; - tests with specified TRV have been modified to be in accordance with the practice described in IEC 62271-100; - the behaviour of the switch during breaking tests has been clarified and boundaries for restrike allowance have been defined; - explanations for short-circuit making tests have been added; - vacuum integrity check after mechanical operations has been defined; - all test voltages for single-phase capacitive testing have been grouped under 7.101.7.3.2 and have been confirmed by simulation and calculation.
- Standard91 pagesEnglish languagesale 10% offe-Library read for×1 day
- 09-Nov-2023
- 15-Feb-2022
- 29.130.10
- CLC/TC 17AC
IEC 62271-105:2021 is available as IEC 62271-105:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 62271-105:2021 applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches composed of switches or switch-disconnectors and current-limiting fuses designed so as to be capable of - breaking, at the rated voltage, any current up to and including the rated short-circuit breaking current; - making, at the rated voltage, circuits to which the rated short-circuit breaking current applies. This third edition cancels and replaces the second edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - the document has been updated to be in alignment with the second edition of IEC 62271-1:2017; - rated TRV has been removed (TRV is only a test parameter), as in the latest revision of IEC 62271-100; - differentiation has been introduced between requirements expressed for fulfilling the function expected from a switch-fuse combination, from requirements only relevant when the function is performed by a stand-alone device. The goal is to avoid duplication or conflicts of requirements with a standard dealing with assemblies, when the function is implemented within such an assembly.
- Standard56 pagesEnglish languagesale 10% offe-Library read for×1 day
- 09-Nov-2023
- 29.130.10
- CLC/TC 17AC
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-Sep-2023
- 29.130.10
- CLC/TC 17AC
IEC 62271-110:2023 is available as IEC 62271-110:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62271-110:2023 is applicable to AC switching devices designed for indoor or outdoor installation, for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V and applied for inductive current switching. It is applicable to switching devices (including circuit-breakers in accordance with IEC 62271-100) that are used to switch high‑voltage motor currents and shunt reactor currents and also to high-voltage contactors used to switch high-voltage motor currents as covered by IEC 62271-106. This fifth edition cancels and replaces the fourth edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: references to IEC 62271-100 and IEC 62271-106 have been updated to the latest editions.
- Standard32 pagesEnglish languagesale 10% offe-Library read for×1 day
- 20-Apr-2023
- 29.130.10
- CLC/TC 17AC
This document applies to pressurized partitions used in indoor and outdoor installations of high-voltage AC and DC switchgear and controlgear with rated voltages (Ur) above 1 kV AC / 1,5 kV DC and with design pressure higher than 300 kPa, where the gas is used principally for its dielectric and/or arc-quenching properties. The partitions comprise pressurized barriers in electrical equipment not necessarily limited to the following examples: - circuit-breakers; - switch-disconnectors; - disconnectors; - earthing switches; - current transformers; - voltage transformers; - surge arresters; - busbars and connections; - cable connections/terminations; - cable bushings. Partitions which are only pressurized from one side are also covered. 1 kV AC / 1,5 kV DC means it is valid for the apparatus applied and where the partitions are installed; however, the application of voltages below 1 kV AC / 1,5 kV DC as in, for example, current and voltage transformers are not excluded. This document does not apply to high voltage bushings (see EN 60137, EN 61462 and EN 62155).
- Standard16 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Oct-2022
- 29.130.10
- CLC/TC 17AC
This part of IEC 62271 applies to the procedures for handling of gases and gas mixtures for insulation and/or switching during installation, commissioning, repair, overhaul, normal and abnormal operations and disposal at the end-of-life of high-voltage switchgear and controlgear. These procedures are regarded as minimum requirements to ensure the reliability of electric power equipment, the safety of personal working with these gases and gas mixtures and to minimize the impact on the environment. Additional requirements could be given or specified in the operating instruction manual of the manufacturer. For each gas or gas mixture, which is known to be used in electric power equipment at the date of the publication of this document, a separate annex describes specifications, handling procedures, safety measures, etc. For gases or gas mixtures not covered by these annexes the electric power equipment manufacturer should provide the information needed, following the structure of these annexes. Such gases or gas mixtures should also be described in a next edition or in amendments to this edition. NOTE 1 For the use of this document, high-voltage (HV) is defined as the rated voltage above 1 000 V. However, the term medium-voltage (MV) is commonly used for distribution systems with voltages above 1 kV and generally applied up to and including 52 kV. NOTE 2 Throughout this standard, the term "pressure" stands for "absolute pressure". NOTE 3 Reference is also made to (Cigré Brochure 802, 2020). NOTE 4 For further details on gases, e.g. ecotoxicology, also refer to the chemical database ECHA (www.echa.europa.eu), which takes the actual volume band into consideration. NOTE 5 When reference to circuit-breakers is made, only gas circuit-breakers are of interest. When vacuum circuit breakers are of interest, they are explicitly mentioned.
- Standard241 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard241 pagesEnglish languagesale 10% offe-Library read for×1 day
- 15-Sep-2022
- 29.130.10
- 29.130.99
- CLC/TC 17AC
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.