Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments

Applies to electrical and electronic apparatus intended for use in industrial environments, for which no dedicated product or product-family immunity standard exists. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered, in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges. Test requirements are specified for each port considered. Apparatus intended to be used in industrial locations are characterized by the existence of one or more of the following: - a power network exists powered by a high or medium voltage power transformer dedicated for the supply of an installation feeding manufacturing or similar plant; - industrial, scientific and medical (ISM) apparatus; - heavy inductive or capacitive loads are frequently switched; - currents and associated magnetic fields are high.

Elektromagnetische Verträglichkeit (EMV) - Teil 6-2: Fachgrundnormen - Störfestigkeit - Industriebereich

Compatibilité électromagnétique (CEM) - Partie 6-2: Normes génériques - Immunité pour les environnements industriels

S'applique aux appareils électriques et électroniques destinés à être utilisés dans les environnements industriels, pour lesquels aucune norme d'immunité spécifique à un produit ou à une famille de produits n'existe. Cette norme couvre les exigences d'immunité dans la gamme de fréquences de 0 Hz à 400 GHz, en rapport avec les perturbations continues et transitoires, conduites et rayonnées, y compris les décharges électrostatiques. Les prescriptions d'essais sont spécifiées pour chaque accès considéré. Les appareils destinés à être utilisés dans des sites industriels sont caractérisés par l'existence d'une ou plusieurs des conditions suivantes: - existence d'une installation de puissance alimentée par un transformateur de puissance haute ou moyenne tension, réservé à l'alimentation d'une installation alimentant un site industriel ou analogue; - présence d'appareils industriels, scientifiques et médicaux (ISM); - commutations fréquentes de charges inductives ou capacitives importantes; - valeurs élevées des courants et des champs magnétiques associés.

Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments (IEC 61000-6-2:1999)

General Information

Status
Withdrawn
Publication Date
01-Apr-1999
Drafting Committee
IEC/TC 77 - IEC_TC_77
Parallel Committee
IEC/TC 77 - IEC_TC_77
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Jul-2004
Completion Date
01-Jul-2004

Relations

Effective Date
29-Jan-2023
Effective Date
29-Jan-2023
Effective Date
09-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026

Buy Documents

Standard

EN 61000-6-2:2000

English language (18 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

TL 9000 QuEST Forum

Telecommunications quality management system.

ANAB United States Verified

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

Sponsored listings

Frequently Asked Questions

EN 61000-6-2:1999 is a standard published by CLC. Its full title is "Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments". This standard covers: Applies to electrical and electronic apparatus intended for use in industrial environments, for which no dedicated product or product-family immunity standard exists. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered, in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges. Test requirements are specified for each port considered. Apparatus intended to be used in industrial locations are characterized by the existence of one or more of the following: - a power network exists powered by a high or medium voltage power transformer dedicated for the supply of an installation feeding manufacturing or similar plant; - industrial, scientific and medical (ISM) apparatus; - heavy inductive or capacitive loads are frequently switched; - currents and associated magnetic fields are high.

Applies to electrical and electronic apparatus intended for use in industrial environments, for which no dedicated product or product-family immunity standard exists. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered, in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges. Test requirements are specified for each port considered. Apparatus intended to be used in industrial locations are characterized by the existence of one or more of the following: - a power network exists powered by a high or medium voltage power transformer dedicated for the supply of an installation feeding manufacturing or similar plant; - industrial, scientific and medical (ISM) apparatus; - heavy inductive or capacitive loads are frequently switched; - currents and associated magnetic fields are high.

EN 61000-6-2:1999 is classified under the following ICS (International Classification for Standards) categories: 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 61000-6-2:1999 has the following relationships with other standards: It is inter standard links to EN 50082-2:1995, EN 61000-6-2:2001, EN 13589:2003, EN 55022:1998, EN 61000-4-4:1995, EN 61000-4-3:1996, EN 55011:1998, EN 61000-4-11:1994, EN 61000-4-8:1993, EN 61000-4-6:1996, EN 61000-4-5:1995, EN 61000-4-2:1995, EN 620:2002+A1:2010, EN 12957:2001+A1:2009, EN 1776:2025. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 61000-6-2:1999 is associated with the following European legislation: EU Directives/Regulations: 1999/5/EC, 2004/108/EC, 2004/108/EU, 89/336/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 61000-6-2:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-april-2000
1DGRPHãþD
SIST EN 50082-2:1997
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for
industrial environments (IEC 61000-6-2:1999)
Electromagnetic compatibility (EMC) -- Part 6-2: Generic standards - Immunity for
industrial environments
Elektromagnetische Verträglichkeit (EMV) -- Teil 6-2: Fachgrundnormen - Störfestigkeit -
Industriebereich
Compatibilité électromagnétique (CEM) -- Partie 6-2: Normes génériques - Immunité
pour les environnements industriels
Ta slovenski standard je istoveten z: EN 61000-6-2:1999
ICS:
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

--------------------
...