EN 61262-4:1994
(Main)Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 4: Determination of the image distortion
Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 4: Determination of the image distortion
Applies to electro-optical X-ray image intensifiers for medical use, as components of diagnostic X-ray equipment. Describes a method of determining the image distortion of X-ray image intensifiers.
Mediziniche elektrische Geräte - Merkmale von elektronenoptischen Röntgenbildverstärkern - Teil 4: Bestimmung der Bildverzeichnung
Appareils électromédicaux - Caractéristiques des intensificateurs électro-optiques d'image radiologique - Partie 4: Détermination de la distorsion d'image
Concerne les intensificateurs électro-optiques d'image radiologique destinés à une utilisation médicale en tant que composants d'équipement à rayonnement X de diagnostic. Décrit une méthode de détermination de la distorsion d'image des intensificateurs d'image radiologique.
Medical electrical equipment - Characteristics of electro optical X ray image intensifiers - Part 4: Determination of the image distortion (IEC 1262-4:1994)
General Information
- Status
- Published
- Publication Date
- 08-Sep-1994
- Withdrawal Date
- 30-Jun-1995
- Technical Committee
- CLC/TC 62 - Electrical equipment in medical practice
- Drafting Committee
- IEC/SC 62B - IEC_SC_62B
- Parallel Committee
- IEC/SC 62B - IEC_SC_62B
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 09-Sep-1994
- Completion Date
- 09-Sep-1994
Relations
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
Overview
EN 61262-4:1994 (CLC) - Medical electrical equipment - Characteristics of electro‑optical X‑ray image intensifiers - Part 4: Determination of the image distortion - is a European adoption of IEC 1262-4:1994. The standard applies to electro‑optical X‑ray image intensifiers used as components in diagnostic X‑ray equipment and describes a method for measuring and reporting image distortion. It establishes a common basis for assessing geometric fidelity of intensifiers in clinical imaging chains.
Key topics and requirements
The document focuses on practical measurement and characterization rather than design limits. Key technical topics include:
- Scope and definitions relevant to electro‑optical X‑ray image intensifiers and image distortion terminology.
- Methodology for determining image distortion, specifying a standardized approach to measure geometric distortions produced by the intensifier.
- Test arrangement and equipment - general requirements for the test setup (e.g., use of suitable test patterns/phantoms, imaging geometry and acquisition conditions) to ensure repeatable measurements.
- Measurement procedure - steps to acquire test images, detect reference points or grid markers, and calculate distortion across the image field.
- Data analysis and reporting - how to express distortion results (qualitative maps and quantitative values), document test conditions, and present findings for traceability and comparison.
- Acceptance and repeatability considerations - guidance on ensuring reproducible results and identifying significant deviations that may affect diagnostic use.
(Note: the standard specifies methods and reporting requirements; specific numeric limits or formulae are contained in the official text.)
Applications and users
EN 61262-4:1994 is directly useful for:
- Medical device manufacturers - validating and characterizing image intensifier performance during development and production testing.
- Independent test laboratories and certification bodies - performing compliance testing and performance verification.
- Clinical engineers and medical physicists - acceptance testing, periodic quality assurance (QA), and maintenance of diagnostic X‑ray systems.
- Hospital procurement and regulatory reviewers - evaluating vendor specifications and ensuring equipment meets expected imaging performance for patient care.
Practical benefits include improved geometric accuracy in fluoroscopic and radiographic imaging, consistent QA procedures, and clearer documentation for regulatory compliance.
Related standards
- IEC 1262-4:1994 - original international document equivalent to EN 61262-4:1994.
- Other parts of the EN/IEC 61262 series covering additional characteristics of X‑ray image intensifiers and related test methods.
- National adoptions (e.g., SIST EN 61262-4:1995) reflect local publishing and copyright considerations.
Keywords: EN 61262-4:1994, image distortion, X‑ray image intensifiers, electro‑optical, medical electrical equipment, determination of the image distortion, diagnostic X‑ray equipment, IEC 1262-4.
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

TÜV Rheinland
TÜV Rheinland is a leading international provider of technical services.

TÜV SÜD
TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.
Sponsored listings
Frequently Asked Questions
EN 61262-4:1994 is a standard published by CLC. Its full title is "Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 4: Determination of the image distortion". This standard covers: Applies to electro-optical X-ray image intensifiers for medical use, as components of diagnostic X-ray equipment. Describes a method of determining the image distortion of X-ray image intensifiers.
Applies to electro-optical X-ray image intensifiers for medical use, as components of diagnostic X-ray equipment. Describes a method of determining the image distortion of X-ray image intensifiers.
EN 61262-4:1994 is classified under the following ICS (International Classification for Standards) categories: 11.040.50 - Radiographic equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 61262-4:1994 has the following relationships with other standards: It is inter standard links to HD 501 S1:1988, EN 61262-7:1995. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 61262-4:1994 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-maj-1995
Medical electrical equipment - Characteristics of electro optical X ray image
intensifiers - Part 4: Determination of the image distortion (IEC 1262-4:1994)
Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers --
Part 4: Determination of the image distortion
Mediziniche elektrische Geräte - Merkmale von elektronenoptischen
Röntgenbildverstärkern -- Teil 4: Bestimmung der Bildverzeichnung
Appareils électromédicaux - Caractéristiques des intensificateurs électro-optiques
d'image radiologique -- Partie 4: Détermination de la distorsion d'image
Ta slovenski standard je istoveten z: EN 61262-4:1994
ICS:
11.040.50 Radiografska oprema Radiographic equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...