prEN IEC 61300-2-21:2025
(Main)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test
DOW = DOR + 12 months + DOW
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prüf- und Messverfahren - Teil 2-21: Prüfungen - kombinierte Temperatur/Feuchte, zyklisch
Dispositifs d'interconnexion et composants passifs fibroniques - Méthodes fondamentales d'essais et de mesures - Partie 2-21: Essais - Essai cyclique composite de température et d'humidité
Optični spojni elementi in pasivne komponente - Osnovni preskusni in merilni postopki - 2-21. del: Preskusi - Sestavljeno ciklično preskušanje temperatura-vlaga
General Information
- Status
- Not Published
- Publication Date
- 31-Aug-2026
- Drafting Committee
- IEC/SC 86B - IEC_SC_86B
- Current Stage
- 4060 - Enquiry results established and sent to TC, SR, BTTF - Enquiry
- Start Date
- 25-Apr-2025
- Completion Date
- 25-Apr-2025
Relations
- Effective Date
- 01-Jun-2021
Overview
The prEN IEC 61300-2-21:2025 standard, titled "Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test," is developed by CLC under IEC technical committee 86. This international standard specifies a comprehensive composite temperature and humidity cyclic test designed to evaluate the resistance and reliability of fibre optic devices and passive components when exposed to severe environmental conditions. It is intended to simulate harsh operational environments characterized by alternating high temperatures, high humidity, and sub-zero cold cycles.
This test addresses the effects of moisture absorption, condensation, and freezing of trapped water inside the device under test (DUT), which can cause performance deterioration such as mechanical degradation or optical attenuation.
Key Topics
Scope and Purpose
The test aims to assess DUT durability by subjecting it to cyclic changes in temperature and humidity, including sub-zero temperature exposures to simulate freezing conditions. It reveals defects caused by moisture ingress and thermal cycling stresses.Test Conditions
- 10 cycles of a 24-hour regime involving humidity exposure at temperatures ranging between 25 °C and 65 °C, followed by cold exposure at -10 °C.
- High humidity levels maintained between 88 % RH and 93 % RH during warm cycles.
- Cold sub-cycles of 3 hours at –10 °C to assess freezing impacts.
- Rapid temperature ramp rates to increase test severity, emulating real-world environmental changes.
Apparatus Requirements
- Humidity chambers with precise temperature and humidity control featuring uniform environmental distribution and continuous air stirring to avoid condensation on DUT.
- Cold chambers capable of holding a steady –10 °C for extended periods.
- Combined chambers for temperature/humidity and cold cycling that meet the detailed ramp-up and ramp-down times specified.
- Optical measurement setups compliant with IEC 61300-3-3 for monitoring attenuation and return loss during testing.
Test Procedure
- Preconditioning of DUT at 55 °C and less than 20% RH for 24 hours before testing.
- Initial optical and visual examinations according to IEC 61753 and IEC 61300-3-1 standards.
- DUT is then subjected to the temperature/humidity cycling with measurements intermittently conducted to monitor any performance degradation.
- Final assessments after test completion include detailed visual and optical measurements to identify lasting effects.
Applications
This standard is crucial for manufacturers, testers, and quality assurance teams involved in the production and certification of fibre optic interconnecting devices and passive components used in telecommunications, data centers, and industrial optical networks. It helps:
- Validate product robustness for outdoor or harsh indoor environments with fluctuating temperature and humidity.
- Predict long-term reliability to reduce field failures related to environmental exposure.
- Ensure compliance with international quality requirements, enhancing market acceptance globally.
- Provide a benchmark for performance under combined moisture and thermal stress, which is critical for components comprising diverse materials sensitive to environmental effects.
Related Standards
- IEC 60068-2-38:2021: Environmental testing - Composite temperature/humidity cyclic test, which defines the fundamental environmental test method used.
- IEC 61300-1 & IEC 61300-3-x series: Covering basic test and measurement procedures, visual examinations, and optical performance evaluations for fibre optic components.
- IEC 61753 series: Performance standards guiding optical and mechanical test requirements for fibre optic devices.
- IEC 62005 series: Standards on reliability testing procedures for fibre optic interconnecting devices and components.
Conclusion
prEN IEC 61300-2-21:2025 provides a rigorous and detailed testing framework for assessing the impact of composite temperature and humidity cycling on fibre optic interconnecting devices. By following these procedures, stakeholders can ensure their fibre optic products maintain optical and mechanical integrity under extreme environmental conditions, thereby supporting enhanced durability, reliability, and customer confidence in fibre optic communication systems.
Frequently Asked Questions
prEN IEC 61300-2-21:2025 is a draft published by CLC. Its full title is "Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test". This standard covers: DOW = DOR + 12 months + DOW
DOW = DOR + 12 months + DOW
prEN IEC 61300-2-21:2025 is classified under the following ICS (International Classification for Standards) categories: 33.180.20 - Fibre optic interconnecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.
prEN IEC 61300-2-21:2025 has the following relationships with other standards: It is inter standard links to EN 61300-2-21:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
prEN IEC 61300-2-21:2025 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2025
Optični spojni elementi in pasivne komponente - Osnovni preskusni in merilni
postopki - 2-21. del: Preskusi - Sestavljeno ciklično preskušanje temperatura-vlaga
Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prüf- und
Messverfahren - Teil 2-21: Prüfungen - kombinierte Temperatur/Feuchte, zyklisch
Dispositifs d'interconnexion et composants passifs à fibres optiques - Méthodes
fondamentales d'essais et de mesures - Partie 2-21: Essais - Essai cyclique composite
de température et d'humidité
Ta slovenski standard je istoveten z: prEN IEC 61300-2-21:2025
ICS:
33.180.20 Povezovalne naprave za Fibre optic interconnecting
optična vlakna devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
86B/4988/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 61300-2-21 ED3
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2025-01-31 2025-04-25
SUPERSEDES DOCUMENTS:
86B/4945/CD, 86B/4957A/CC
IEC SC 86B : FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS
SECRETARIAT: SECRETARY:
Japan Mr Ryo Koyama
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):
ASPECTS CONCERNED:
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft for
Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which
they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some Countries”
clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is the final stage for
submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).
TITLE:
Fibre optic interconnecting devices and passive components - Basic test and measurement
procedures - Part 2-21: Tests - Composite temperature/humidity cyclic test
PROPOSED STABILITY DATE: 2032
NOTE FROM TC/SC OFFICERS:
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.
IEC CDV 61300-2-21/Ed3 © IEC 2025 2 86B/4988/CDV
1 CONTENTS
2 1 Scope . 5
3 2 Normative references . 5
4 3 Terms and definitions . 6
5 4 General . 6
6 5 Apparatus . 6
7 5.1 General . 6
8 5.2 Chamber for the exposure to high temperature and humidity . 6
9 5.3 Chamber for exposure to cold . 6
10 5.4 Temperature and humidity chamber . 7
11 5.5 Optical measurement equipment . 7
12 6 Procedure . 7
13 6.1 Preparation of DUT . 7
14 6.2 Preconditioning . 7
15 6.3 Initial examinations and measurements . 8
16 6.4 Conditioning . 9
17 6.4.1 General . 9
18 6.4.2 Description of 24 h cycle . 9
19 6.4.2.1 Description of high temperature and humidity subcycle . 9
20 6.4.2.2 Description of cold subcycle . 10
21 6.4.3 Examinations and measurements during test . 12
22 6.5 Recovery . 12
23 6.6 Final examinations and measurements . 12
24 7 Severity. 12
25 8 Details to be specified and reported . 13
27 Figure 1 – Preconditioning:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: 6
28 Figure 2 – Exposure to high temperature and humidity followed by exposure to cold 9
IEC CDV 61300-2-21/Ed3 © IEC 2025 3 86B/4988/CDV
32 INTERNATIONAL ELECTROTECHNICAL COMMISSION
33 ____________
35 FIBRE OPTIC INTERCONNECTING
36 DEVICES AND PASSIVE COMPONENTS –
37 BASIC TEST AND MEASUREMENT PROCEDURES –
39 Part 2-21: Tests –
40 Composite temperature/humidity cyclic test
43 FOREWORD
44 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national
45 electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all
46 questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC
47 publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and
48 Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National
49 Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-
50 governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the
51 International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two
52 organizations.
53 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus
54 of opinion on the relevant subjects since each technical committee has representation from all interested IEC National
55 Committees.
56 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in
57 that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC
58 cannot be held responsible for the way in which they are used or for any misinterpretation by any end user.
59 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to
60 the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the
61 corresponding national or regional publication shall be clearly indicated in the latter.
62 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment
63 services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by
64 independent certification bodies.
65 6) All users should ensure that they have the latest edition of this publication.
66 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its
67 technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature
68 whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of,
69 or reliance upon, this IEC Publication or any other IEC Publications.
70 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable
71 for the correct application of this publication.
72 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC
73 shall not be held responsible for identifying any or all such patent rights.
74 International Standard IEC 61300-2-21 has been prepared by subcommittee 86B: Fibre optic
75 interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
76 This third edition cancels and replaces the second edition published in 2009. It constitutes a technical
77 revision. The changes with respect to the previous edition are:
78 – to reconsider the whole parts of the standard;
79 – update of Figures 1 and 2 according to IEC 60068-2-38: 2021.
80 The text of this standard is based on the following documents:
FDIS Report on voting
IEC CDV 61300-2-21/Ed3 © IEC 2025 4 86B/4988/CDV
86B/XX/FDIS 86B/XX/RVD
81 This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
82 A list of all the parts of IEC 61300 series, under the general title, Fibre optic interconnecting devices and
83 passive components – Basic test and measurement procedures, can be found on the IEC website.
84 The committee has decided that the contents of this publication will remain unchanged until the stability
85 date indicated on the IEC web site under "http://webstore.iec.ch" in the data related to the specific
86 publication. At this date, the publication will be
87 • reconfirmed,
88 • withdrawn,
89 • replaced by a revised edition, or
90 • amended.
IEC CDV 61300-2-21/Ed3 © IEC 2025 5 86B/4988/CDV
91 FIBRE OPTIC INTERCONNECTING
92 DEVICES AND PASSIVE COMPONENTS –
93 BASIC TEST AND MEASUREMENT PROCEDURES –
95 Part 2-21: Tests –
96 Composite temperature/humidity cyclic test
100 1 Scope
101 The purpose of this part of IEC 61300 is to determine the resistance of a fibre optic device or component
102 to the deteriorative effects of high temperature, humidity and cold conditions.
103 It is intended to reveal defects in a device under test (DUT) caused by breathing as opposed to
104 absorption of moisture. The test covers the effect of the freezing of trapped water in cracks and fissures
105 as well as condensation. However, the degree of condensation will vary depending on the size and
106 thermal mass of the DUT.
107 This test differs from other cyclic damp heat tests in that it derives its increased severity from:
108 a) a greater number of temperature variations leading to pumping actions in a given time;
109 b) a greater cyclic temperature range;
110 c) a higher rate of change of temperature;
111 d) the inclusion of a number of excursions to sub-zero temperature.
112 This type of test is particularly important for fibre optic devices or components made of a variety of
113 different materials.
114 2 Normative references
115 The following referenced documents are indispensable for the application of this document. For dated
116 references, only the edition cited applies. For undated references, the latest edition of the referenced
117 document (including any amendments) applies.
118 IEC 60068-2-38: 2021, Environmental testing – Part 2-38: Tests – Test Z/AD: Composite
119 temperature/humidity cyclic test
120 IEC 61300-1, Fibre optic interconnecting devices and passive components – Basic test and
121 measurement procedures – Part 3-1: Examinations and measurements – Visual examination
122 IEC 61300-3-1, Fibre optic interconnecting devices and passive components – Basic test and
123 measurement procedures – Part 1: General and guidance
124 IEC 61300-3-3
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...