Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation

This European Standard applies to multicore cables insulated and sheathed with heat resistant crosslinked silicone rubber. Types with or without an overall textile braid, and with or without a strain-bearing element, are included. The cables are of rated voltages U0/U 300/500 V. The cables are intended for use within high temperature zones, either: - in fixed installations with mechanical protection (cables to 4.1); or - for flexible use under low mechanical stress (cables to 4.2). The maximum conductor operating temperature for each of the cables in this standard is 180 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-83 should be read in conjunction with EN 50525-1, which specifies general requirements.

Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) - Teil 2-83: Starkstromleitungen für allgemeine Anwendungen - Mehradrige Leitungen mit vernetzter Silikon-Isolierung

Câbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à 450/750 V (U0/U) - Partie 2-83: Câbles pour applications générales - Câbles multiconducteurs isolés au silicone réticulé

Električni kabli - Nizkonapetostni energetski kabli z nazivno napetostjo do vključno 450/750 V - 2-83. del: Kabli za splošno uporabo - Večžilni kabli z zamreženo elastomerno izolacijo iz silikonske gume

Ta evropski standard velja za večžilne kable, ki so oplaščeni in imajo zamreženo elastomerno izolacijo iz toplotno odporne silikonske gume. Vključeni so tipi, ki so ali niso v celoti pleteni iz tkanine in z elementom napetostne zmogljivosti ali brez njega. Ti kabli imajo nazivno napetost U0/U 300/500 V. Kabli so primerni za uporabo na območjih z visokimi temperaturami ali: - pri fiksnih inštalacijah z mehansko zaščito (kabli do točke 4.1.); ali - za fleksibilno uporabo pod nizkim mehanskih stresom (kabli do točke 4.2). Maksimalna delovna temperatura pretvornika za vsakega od kablov iz tega standarda je 180 °C.

General Information

Status
Published
Publication Date
05-May-2011
Withdrawal Date
16-Jan-2014
Technical Committee
CLC/TC 20 - Electric cables
Drafting Committee
CLC/TC 20 - Electric cables
Current Stage
9093 - Decision to confirm - Review Enquiry
Start Date
23-Oct-2024
Completion Date
21-Jan-2026

Relations

Effective Date
28-Jan-2023

Overview

EN 50525-2-83:2011 is a European Standard published by CLC (CENELEC) that specifies requirements for low voltage multicore electric cables with crosslinked silicone rubber insulation. These cables are designed for rated voltages up to and including 450/750 V (U0/U). Specifically, the standard addresses multicore cables with heat-resistant crosslinked silicone rubber insulation and sheathing intended for use in high temperature environments.

The standard covers cables both with and without an overall textile braid and with or without a strain-bearing element. These cables are suitable for fixed installations with mechanical protection as well as flexible use under low mechanical stress. A key feature of cables conforming to this standard is their capability to withstand a maximum conductor operating temperature of 180 °C.

EN 50525-2-83:2011 should be read alongside EN 50525-1, which specifies the general requirements for low voltage energy cables.


Key Topics

  • Cable Construction

    • Conductors must be Class 5 stranded according to EN 60228.
    • Insulation is made from Type EI 2 crosslinked elastomeric silicone rubber (EN 50363-1).
    • Sheath uses Type EM 9 crosslinked elastomeric silicone rubber (EN 50363-2-1).
    • Possible inclusion of a textile braid for extra mechanical protection.
    • Strain-bearing elements made of non-metallic materials may be included, designed to reduce strain on conductors.
  • Cable Types Covered

    • H05SS-F & H05SST-F: Basic multicore heat-resistant cables with or without braid.
    • H05SSD3-K & H05SSD3T-K: Multicore cables with strain-bearing element, with or without braid.
  • Operating Conditions

    • Rated voltage: U0/U 300/500 V.
    • Max conductor temperature: 180 °C, suitable for high-temperature zones.
    • Application in fixed installations with mechanical protection or flexible usage under low mechanical stress.
  • Testing & Compliance

    • Electrical, mechanical, and material tests per annexes to ensure quality and performance.
    • Ageing tests at 200 °C to simulate long-term heat exposure.
    • Fire resistance tests for flame propagation.
    • Compatibility tests on insulation and sheath materials.
    • Dimensional checks for insulation thickness, sheath thickness, and overall cable diameter.
  • Marking & Identification

    • Cables marked with CENELEC codes like H05SS-F, H05SST-F, H05SSD3-K, and H05SSD3T-K.
    • Marking aligns with EN 50525-1 requirements for traceability and identification.

Applications

EN 50525-2-83 cables are designed for demanding electrical installations where high temperature resistance and mechanical reliability are critical. Common applications include:

  • Industrial settings, such as zones with high ambient temperatures or heat sources.
  • Fixed installations where cables require mechanical protection (e.g., conduits in factories, HVAC systems).
  • Flexible connections under low mechanical stress, suitable for equipment that requires frequent movement but little strain.
  • Use in environments requiring compliance with fire safety standards due to flame retardant properties.
  • Situations demanding strain relief via strain-bearing elements to protect conductors in flexible cables.

By meeting stringent European and IEC standards, these cables ensure safety, durability, and performance in both residential and commercial electrical systems.


Related Standards

  • EN 50525-1: General requirements for low voltage energy cables.
  • EN 60228: Specifications for conductors of insulated cables.
  • EN 50363-1: Insulating materials – crosslinked elastomeric insulating compounds.
  • EN 50363-2-1: Sheathing materials – crosslinked elastomeric sheathing compounds.
  • EN 50395 / EN 50396: Electrical and non-electrical test methods for low voltage cables.
  • EN 60332-1-2: Fire testing – tests for vertical flame propagation.
  • EN 60811 series: Common test methods for insulating and sheathing material ageing and mechanical properties.
  • HD 516: Guide for safe use of low voltage harmonized cables.

Integrating these standards with EN 50525-2-83 helps ensure comprehensive compliance and interoperability of low voltage multicore cables in Europe and globally.


Keywords: EN 50525-2-83, low voltage electric cables, multicore cables, crosslinked silicone rubber insulation, heat resistant cables, flexible cables, fixed installation cables, strain-bearing element, mechanical protection, rated voltage 450/750 V, CENELEC standards, electrical cable testing, fire-resistant cables.

Get Certified

Connect with accredited certification bodies for this standard

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

CEPREI Certification Center (Guangzhou Saibao)

Pioneer of third-party certification, subsidiary of Electronic Fifth Research Institute.

CNAS China Verified

CESI Beijing Certification (Saisi)

Subsidiary of China Electronics Standardization Institute (CESI), established 1963.

CNAS China Verified

Sponsored listings

Frequently Asked Questions

EN 50525-2-83:2011 is a standard published by CLC. Its full title is "Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation". This standard covers: This European Standard applies to multicore cables insulated and sheathed with heat resistant crosslinked silicone rubber. Types with or without an overall textile braid, and with or without a strain-bearing element, are included. The cables are of rated voltages U0/U 300/500 V. The cables are intended for use within high temperature zones, either: - in fixed installations with mechanical protection (cables to 4.1); or - for flexible use under low mechanical stress (cables to 4.2). The maximum conductor operating temperature for each of the cables in this standard is 180 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-83 should be read in conjunction with EN 50525-1, which specifies general requirements.

This European Standard applies to multicore cables insulated and sheathed with heat resistant crosslinked silicone rubber. Types with or without an overall textile braid, and with or without a strain-bearing element, are included. The cables are of rated voltages U0/U 300/500 V. The cables are intended for use within high temperature zones, either: - in fixed installations with mechanical protection (cables to 4.1); or - for flexible use under low mechanical stress (cables to 4.2). The maximum conductor operating temperature for each of the cables in this standard is 180 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-83 should be read in conjunction with EN 50525-1, which specifies general requirements.

EN 50525-2-83:2011 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 50525-2-83:2011 has the following relationships with other standards: It is inter standard links to HD 22.15 S2:2007. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 50525-2-83:2011 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU, 2014/53/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 50525-2-83:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) - Teil 2-83: Starkstromleitungen für allgemeine Anwendungen - Mehradrige Leitungen mit vernetzter Silikon-IsolierungCâbles électriques - Câbles d’énergie basse tension de tension assignée au plus égale à 450/750 V (U0/U) - Partie 2-83: Câbles pour applications générales - Câbles multiconducteurs isolés au silicone réticuléElectric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation29.060.20KabliCablesICS:Ta slovenski standard je istoveten z:EN 50525-2-83:2011SIST EN 50525-2-83:2011en01-september-2011SIST EN 50525-2-83:2011SLOVENSKI
STANDARD
EUROPEAN STANDARD EN 50525-2-83 NORME EUROPÉENNE
EUROPÄISCHE NORM May 2011
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2011 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50525-2-83:2011 E
ICS 29.060.20 Supersedes HD 22.15 S2:2007
English version
Electric cables -
Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) -
Part 2-83: Cables for general applications -
Multicore cables with crosslinked silicone rubber insulation
Câbles électriques -
Câbles d’énergie basse tension de tension assignée au plus égale à 450/750 V (U0/U) -
Partie 2-83: Câbles pour applications générales -
Câbles multiconducteurs isolés au siliconeréticulé
Kabel und Leitungen -
Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) -
Teil 2-83: Starkstromleitungen für allgemeine Anwendungen -
Mehradrige Leitungen mit vernetzter Silikon-Isolierung
This European Standard was approved by CENELEC on 2011-01-17. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
The text of the draft was submitted to the formal vote and was accepted by CENELEC as EN 50525-2-83 on 2011-01-17.
This document, which is one of a multipart series, supersedes HD 22.15 S2:2007.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights.
The following dates are proposed:
– latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement
(dop)
2012-01-17 – latest date by which the national standards conflicting with the EN have to be withdrawn
(dow)
2014-01-17
____________ SIST EN 50525-2-83:2011

- 3 - EN 50525-2-83:2011
Contents Page 1Scope . 42Normative references . 43Terms and definitions . 54Heat resistant cables (180 °C) . 54.1Cables H05SS-F and braided cables H05SST-F . 54.2Cables H05SSD3-K and braided cables H05SSD3T-K, with strain-bearing element . 6Annex A (normative)
Tests for cables to EN 50525-2-83 . 8Annex B (normative)
General data . 10Annex C (normative)
Requirements for compatibility test . 11C.1Test conditions . 11C.2Requirements . 11Bibliography . 12 Tables Table A.1 . 8Table B.1 . 10Table C.1
Requirements . 11 SIST EN 50525-2-83:2011

- for flexible use under low mechanical stress (cables to 4.2). The maximum conductor operating temperature for each of the cables in this standard is 180 °C. NOTE HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-2-83 should be read in conjunction with EN 50525-1, which specifies general requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
NOTE One or more references to the standards below are in respect of a specific sub-division of that standard, for instance a clause, a table, a class or a type. Cross-references to these standards are undated and, at all times, the latest version applies.
EN 50363-1
Insulating, sheathing and covering materials for low voltage energy cables − Part 1: Cross-linked elastomeric insulating compounds EN 50363-2-1
Insulating, sheathing and covering materials for low voltage energy cables − Part 2-1: Cross-linked elastomeric sheathing compounds EN 50395
Electrical test methods for low voltage energy cables EN 50396
Non electrical test methods for low voltage energy cables EN 50525-1
Electric cables − Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) − Part 1: General requirements EN 60228
Conductors of insulated cables (IEC 60228) EN 60332-1-2
Tests on electric and optical fibre cables under fire conditions −
Part 1-2: Test for vertical flame propagation for a single insulated wire or cable − Procedure for 1 kW pre-mixed flame (IEC 60332-1-2) EN 60811-1-2
Insulating and sheathing materials of electric
and optical cables − Common test methods − Part 1-2: General application − Thermal ageing methods (IEC 60811-1-2) EN 60811-1-4
Insulating and sheathing materials of electric and optical cables − Common test methods − Part 1-4: General application − Tests at low temperature (IEC 60811-1-4) EN ISO 6892-1 2009 Metallic materials − Tensile testing − Part 1: Method of test at room temperature (ISO 6892-1:2009) SIST EN 50525-2-83:2011

- 5 - EN 50525-2-83:2011
3 Terms and definitions For
...