Electricity metering data exchange - The DLMS/COSEM suite - Part 3-1: Use of local area networks on twisted pair with carrier signalling

IEC 62056-3-1:2013 describes three profiles for local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. Three different profiles are supported: - base profile; - profile with DLMS; - profile with DLMS/COSEM. The three profiles use the same physical layer and they are fully compatible, meaning that devices implementing any of these profiles can be operated on the same bus. The transmission medium is twisted pair using carrier signalling and it is known as the Euridis Bus. This first edition cancels and replaces the first edition of IEC 62056-31, issued in 1999, and constitutes a technical revision. The main technical changes are: - addition of a profile which makes use of the IEC 62056 DLMS/COSEM Application layer and COSEM object model, - review of the data link layer which is split into two parts: a pure Data Link layer; a "Support Manager" entity managing the communication media; - ability to negotiate the communication speed, bringing baud rate up to 9 600 bauds.

Datenkommunikation der elektrischen Energiemessung - DLMS/COSEM - Teil 3-1: Nutzung lokaler Netzwerke mit Trägerfrequenz-Signalübertragung auf verdrillten Zweidrahtleitungen

Échange des données de comptage de l'électricité - La suite DLMS/COSEM - Partie 3-1: Utilisation des réseaux locaux sur paire torsadée avec signal de porteuse

La CEI 62056-3-1:2013 décrit trois profils pour échange de données par bus en local avec des stations alimentées ou non en énergie. Pour les stations télé-alimentées, le bus fournit l'énergie pour l'échange des données. Trois différents profils sont supportés: - Profil de base; - Profil avec DLMS; - Profil avec DLMS/COSEM. Les trois profils utilisent la même couche physique et ils sont entièrement compatibles, c'est-à-dire que des équipements ayant implémenté l'un de ces profils peuvent opérer sur le même bus. Le moyen de transmission est la paire torsadée par signal de porteuse et connue sous le nom de Bus Euridis. Cette première édition annule et remplace la première édition de la CEI 62056-31, parue en 1999, dont elle constitue une révision technique. Les modifications techniques sont: - Ajout d'un profil qui permet l'utilisation de la couche Application et la modélisation objet DLMS/COSEM de la CEI 62056, - Révision de la couche liaison de données qui est maintenant scindée en deux parties: la première est intégralement une couche de liaison de données; la dernière, nommée "Gestion du Support", gère le média de communication; - Capacité de négocier la vitesse de communication, portant la vitesse maximale jusqu'à 9 600 bauds.

Merjenje električne energije - Izmenjevanje podatkov za odbiranje stanja števcev, tarife in krmiljenje obremenitve - 31. del: Uporaba lokalnih omrežij prek zvitih parov s signalizacijo po nosilcu (IEC 62056-3-1:2013)

Standard EN-IEC 62056 opisuje tri profile izmenjave podatkov prek lokalnega vodila s postajo z napajanjem ali brez. Pri postajah brez napajanja vodilo zagotavlja energijo za izmenjavo podatkov. Podprti so trije različni profili: – osnovni profil: ta triplastni profil omogoča oddaljene komunikacijske storitve; OPOMBA Ta profil je bil objavljen v standardu IEC 61142:1993 in je poznan kot standard Euridis. – profil z DLMS: ta profil omogoča uporabo storitev DLMS iz standarda IEC 61334-4-41; OPOMBA Ta profil je bil objavljen v standardu IEC 62056-31, izdaja 1.0:1999; – profil z DLMS/COSEM: ta profil omogoča uporabo aplikacijske plasti DLMS/COSEM in objektnega modula COSEM iz standarda IEC 62056-5-3, izdaja 1.0:– in iz standarda IEC 62056- 6-2, izdaja 1.0. Ti trije profili uporabljajo enako fizično plast in so popolnoma združljivi, kar pomeni, da naprave v skladu s katerim koli od teh profilov lahko delujejo na istem vodilu. Medij prenosa je zvit par s signalizacijo po nosilcu in je poznan kot vodilo Euridis.

General Information

Status
Withdrawn
Publication Date
06-Mar-2014
Withdrawal Date
23-Sep-2016
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
11-Aug-2024
Completion Date
11-Aug-2024

Relations

Buy Standard

Standard
EN 62056-3-1:2014
English language
116 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
EN 62056-3-1:2014
English language
116 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-maj-2014
Nadomešča:
SIST EN 62056-31:2000
Merjenje električne energije - Izmenjevanje podatkov za odbiranje stanja števcev,
tarife in krmiljenje obremenitve - 31. del: Uporaba lokalnih omrežij prek zvitih
parov s signalizacijo po nosilcu (IEC 62056-3-1:2013)
Electricity metering - Data exchange for meter reading, tariff and load control - Part 31:
Use of local area networks on twisted pair with carrier signalling
Messung der elektrischen Energie - Zählerstandsübertragung, Tarif- und Laststeuerung -
Teil 31: Nutzung örtlicher Bereichsnetze mit Trägerfrequenz-Signalübertragung auf
verdrillten Zweidrahtleitungen
Comptage de l'électricité - Echange de données pour la lecture des compteurs, le
contrôle des tarifs et de la charge - Partie 31: Utilisation des réseaux locaux sur paire
torsadée avec signal de porteuse
Ta slovenski standard je istoveten z: EN 62056-3-1:2014
ICS:
17.220.20 Merjenje električnih in Measurement of electrical
magnetnih veličin and magnetic quantities
35.110 Omreževanje Networking
91.140.50 Sistemi za oskrbo z elektriko Electricity supply systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 62056-3-1
NORME EUROPÉENNE
March 2014
EUROPÄISCHE NORM
ICS 17.220; 35.110; 91.140.50 Supersedes EN 62056-31:2000

English version
Electricity metering data exchange - The DLMS/COSEM suite -
Part 3-1: Use of local area networks on twisted pair with carrier signalling
(IEC 62056-3-1:2013)
Échange des données de comptage de Datenkommunikation der elektrischen
l'électricité - Energiemessung -
La suite DLMS/COSEM - DLMS/COSEM -
Partie 3-1: Utilisation des réseaux locaux Teil 3-1: Nutzung lokaler Netzwerke mit
sur paire torsadée avec signal de Trägerfrequenz-Signalübertragung auf
porteuse verdrillten Zweidrahtleitungen
(CEI 62056-3-1:2013) (IEC 62056-3-1:2013)

This European Standard was approved by CENELEC on 2013-09-24. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 62056-3-1:2014 E
Foreword
The text of document 13/1546/FDIS, future edition 1 of IEC 62056-3-1, prepared by IEC/TC 13
"Electrical energy measurement, tariff- and load control" was submitted to the IEC-CENELEC parallel
vote and approved by CENELEC as EN 62056-3-1:2014.

The following dates are fixed:
(dop) 2014-09-07
• latest date by which the document has to be
implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2016-09-24
standards conflicting with the
document have to be withdrawn
This document supersedes EN 62056-31:2000.

EN 62056-31:2000:
• addition of a profile which makes use of the EN 62056 DLMS/COSEM Application layer and
COSEM object model;
• review of the data link layer which is split into two parts:
– a pure Data Link layer;
– a “Support Manager” entity managing the communication media;
• ability to negotiate the communication speed, bringing baud rate up to 9 600 bauds.

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 62056-3-1:2013 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:

IEC 62056-6-1:2013 NOTE Harmonized as EN 62056-6-1:2013 (not modified).
IEC 62056-6-2:2013 NOTE Harmonized as EN 62056-6-2:2013 (not modified).

- 3 - EN 62056-3-1:2014
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

IEC 61334-4-41 1996 Distribution automation using distribution EN 61334-4-41 1996
line carrier systems -
Part 4: Data communication protocols -
Section 41: Application protocols -
Distribution line message specification

IEC 62056-51 1998 Electricity metering - Data exchange for - -
meter reading, tariff and load control -
Part 51: Application layer protocols

IEC 62056-5-3 2013 Electricity metering data exchange - The EN 62056-5-3 2014
DLMS/COSEM suite -
Part 5-3: DLMS/COSEM application layer

ISO/IEC 8482 1993 Information technology - - -
Telecommunications and information
exchange between systems - Twisted pair
multipoint interconnections
EIA 485 - Electrical characteristics of generators and - -
receivers for use in balanced digital
multipoint systems
IEC 62056-3-1 ®
Edition 1.0 2013-08
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Electricity metering data exchange – The DLMS/COSEM suite –

Part 3-1: Use of local area networks on twisted pair with carrier signalling

Échange des données de comptage de l'électricité – La suite DLMS/COSEM –

Partie 3-1: Utilisation des réseaux locaux sur paire torsadée avec signal de

porteuse
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX XE
ICS 17.220; 35.110; 91.140.50 ISBN 978-2-8322-1046-8

– 2 – 62056-3-1 © IEC:2013
CONTENTS
FOREWORD . 7
1 Scope . 9
2 Normative references . 9
3 Abbreviations . 10
4 General description . 11
4.1 Basic vocabulary . 11
4.2 Profiles, layers and protocols . 11
4.2.1 Overview . 11
4.2.2 Base profile (without DLMS) . 12
4.2.3 Profile with DLMS . 12
4.2.4 Profile with DLMS/COSEM . 13
4.3 Specification language . 13
4.4 Communication services for local bus data exchange without DLMS . 13
4.4.1 Overview . 13
4.4.2 Remote reading exchange . 14
4.4.3 Remote programming exchange . 14
4.4.4 Point to point remote transfer exchange . 16
4.4.5 Broadcast remote transfer frame . 16
4.4.6 Bus initialization frame . 16
4.4.7 Forgotten station call exchange . 17
4.4.8 Frame fields . 17
4.4.9 Principle of the energy remote supply . 18
4.4.10 Non-energized station preselection exchange . 19
4.4.11 Communication exchange after preselection . 20
4.4.12 Alarm function . 20
4.5 Communication services for local bus data exchange with DLMS . 21
4.6 Systems management . 22
5 Local bus data exchange without DLMS . 22
5.1 Physical layer . 22
5.1.1 Physical-62056-3-1 protocol . 22
5.1.2 Physical parameters . 23
5.1.3 Timing diagrams . 25
5.1.4 Physical services and service primitives . 26
5.1.5 State transitions . 27
5.1.6 List and processing of errors . 34
5.2 Data Link layer . 35
5.2.1 Link-62056-3-1 protocol . 35
5.2.2 Management of exchanges . 35
5.2.3 Data Link services and service primitives . 35
5.2.4 Data Link parameters . 36
5.2.5 State transitions . 36
5.2.6 List and processing of errors . 41
5.3 Application layer . 42
5.3.1 Application-62056-3-1 protocol . 42
5.3.2 Application services and service primitives . 42
5.3.3 Application parameters . 42

62056-3-1 © IEC:2013 – 3 –
5.3.4 State transitions . 43
5.3.5 List and processing of errors . 45
6 Local bus data exchange with DLMS . 45
6.1 Physical layer . 45
6.2 Data Link layer . 46
6.2.1 Link-E/D protocol . 46
6.2.2 Management of exchanges . 46
6.2.3 Data Link services and service primitives . 47
6.2.4 Data Link parameters . 47
6.2.5 State transitions . 48
6.2.6 List and processing of errors .
...


SLOVENSKI STANDARD
01-maj-2014
1DGRPHãþD
SIST EN 62056-31:2000
0HUMHQMHHOHNWULþQHHQHUJLMH,]PHQMHYDQMHSRGDWNRY]DRGELUDQMHVWDQMDãWHYFHY
WDULIHLQNUPLOMHQMHREUHPHQLWYHGHO8SRUDEDORNDOQLKRPUHåLMSUHN]YLWLK
SDURYVVLJQDOL]DFLMRSRQRVLOFX ,(&
Electricity metering - Data exchange for meter reading, tariff and load control - Part 31:
Use of local area networks on twisted pair with carrier signalling
Messung der elektrischen Energie - Zählerstandsübertragung, Tarif- und Laststeuerung -
Teil 31: Nutzung örtlicher Bereichsnetze mit Trägerfrequenz-Signalübertragung auf
verdrillten Zweidrahtleitungen
Comptage de l'électricité - Echange de données pour la lecture des compteurs, le
contrôle des tarifs et de la charge - Partie 31: Utilisation des réseaux locaux sur paire
torsadée avec signal de porteuse
Ta slovenski standard je istoveten z: EN 62056-3-1:2014
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
35.240.60 Uporabniške rešitve IT v IT applications in transport
transportu in trgovini and trade
91.140.50 Sistemi za oskrbo z elektriko Electricity supply systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 62056-3-1
NORME EUROPÉENNE
March 2014
EUROPÄISCHE NORM
ICS 17.220; 35.110; 91.140.50 Supersedes EN 62056-31:2000

English version
Electricity metering data exchange - The DLMS/COSEM suite -
Part 3-1: Use of local area networks on twisted pair with carrier signalling
(IEC 62056-3-1:2013)
Échange des données de comptage de Datenkommunikation der elektrischen
l'électricité - Energiemessung -
La suite DLMS/COSEM - DLMS/COSEM -
Partie 3-1: Utilisation des réseaux locaux Teil 3-1: Nutzung lokaler Netzwerke mit
sur paire torsadée avec signal de Trägerfrequenz-Signalübertragung auf
porteuse verdrillten Zweidrahtleitungen
(CEI 62056-3-1:2013) (IEC 62056-3-1:2013)

This European Standard was approved by CENELEC on 2013-09-24. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels

© 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 62056-3-1:2014 E
Foreword
The text of document 13/1546/FDIS, future edition 1 of IEC 62056-3-1, prepared by IEC/TC 13
"Electrical energy measurement, tariff- and load control" was submitted to the IEC-CENELEC parallel
vote and approved by CENELEC as EN 62056-3-1:2014.

The following dates are fixed:
(dop) 2014-09-07
• latest date by which the document has to be
implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2016-09-24
standards conflicting with the
document have to be withdrawn
This document supersedes EN 62056-31:2000.

EN 62056-31:2000:
• addition of a profile which makes use of the EN 62056 DLMS/COSEM Application layer and
COSEM object model;
• review of the data link layer which is split into two parts:
– a pure Data Link layer;
– a “Support Manager” entity managing the communication media;
• ability to negotiate the communication speed, bringing baud rate up to 9 600 bauds.

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 62056-3-1:2013 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:

IEC 62056-6-1:2013 NOTE Harmonized as EN 62056-6-1:2013 (not modified).
IEC 62056-6-2:2013 NOTE Harmonized as EN 62056-6-2:2013 (not modified).

- 3 - EN 62056-3-1:2014
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year

IEC 61334-4-41 1996 Distribution automation using distribution EN 61334-4-41 1996
line carrier systems -
Part 4: Data communication protocols -
Section 41: Application protocols -
Distribution line message specification

IEC 62056-51 1998 Electricity metering - Data exchange for - -
meter reading, tariff and load control -
Part 51: Application layer protocols

IEC 62056-5-3 2013 Electricity metering data exchange - The EN 62056-5-3 2014
DLMS/COSEM suite -
Part 5-3: DLMS/COSEM application layer

ISO/IEC 8482 1993 Information technology - - -
Telecommunications and information
exchange between systems - Twisted pair
multipoint interconnections
EIA 485 - Electrical characteristics of generators and - -
receivers for use in balanced digital
multipoint systems
IEC 62056-3-1 ®
Edition 1.0 2013-08
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Electricity metering data exchange – The DLMS/COSEM suite –

Part 3-1: Use of local area networks on twisted pair with carrier signalling

Échange des données de comptage de l'électricité – La suite DLMS/COSEM –

Partie 3-1: Utilisation des réseaux locaux sur paire torsadée avec signal de

porteuse
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX XE
ICS 17.220; 35.110; 91.140.50 ISBN 978-2-8322-1046-8

– 2 – 62056-3-1 © IEC:2013
CONTENTS
FOREWORD . 7
1 Scope . 9
2 Normative references . 9
3 Abbreviations . 10
4 General description . 11
4.1 Basic vocabulary . 11
4.2 Profiles, layers and protocols . 11
4.2.1 Overview . 11
4.2.2 Base profile (without DLMS) . 12
4.2.3 Profile with DLMS . 12
4.2.4 Profile with DLMS/COSEM . 13
4.3 Specification language . 13
4.4 Communication services for local bus data exchange without DLMS . 13
4.4.1 Overview . 13
4.4.2 Remote reading exchange . 14
4.4.3 Remote programming exchange . 14
4.4.4 Point to point remote transfer exchange . 16
4.4.5 Broadcast remote transfer frame . 16
4.4.6 Bus initialization frame . 16
4.4.7 Forgotten station call exchange . 17
4.4.8 Frame fields . 17
4.4.9 Principle of the energy remote supply . 18
4.4.10 Non-energized station preselection exchange . 19
4.4.11 Communication exchange after preselection . 20
4.4.12 Alarm function . 20
4.5 Communication services for local bus data exchange with DLMS . 21
4.6 Systems management . 22
5 Local bus data exchange without DLMS . 22
5.1 Physical layer . 22
5.1.1 Physical-62056-3-1 protocol . 22
5.1.2 Physical parameters . 23
5.1.3 Timing diagrams . 25
5.1.4 Physical services and service primitives . 26
5.1.5 State transitions . 27
5.1.6 List and processing of errors . 34
5.2 Data Link layer . 35
5.2.1 Link-62056-3-1 protocol . 35
5.2.2 Management of exchanges . 35
5.2.3 Data Link services and service primitives . 35
5.2.4 Data Link parameters . 36
5.2.5 State transitions . 36
5.2.6 List and processing of errors . 41
5.3 Application layer . 42
5.3.1 Application-62056-3-1 protocol . 42
5.3.2 Application services and service primitives . 42
5.3.3 Application parameters . 42

62056-3-1 © IEC:2013 – 3 –
5.3.4 State transitions . 43
5.3.5 List and processing of errors . 45
6 Local bus data exchange with DLMS . 45
6.1 Physical layer . 45
6.2 Data Link layer . 46
6.2.1 Link-E/D protocol . 46
6.2.2 Management of exchanges . 46
6.2.3 Data Link services and service primitives . 47
6.2.4 Data Link parameters . 47
6.2.5 State transitions . 48
6.2.6 List and process
...

Questions, Comments and Discussion