Solderless connections - Part 4: Non-accessible insulation displacement (ID) connections - General requirements, test methods and practical guidance

IEC 60352-4:2020 is applicable to non-accessible ID connections for which the tests and measurements according to Clauses 6 through 8 are suitable and which are made with: – appropriately designed ID terminations; – wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter; – wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-sectional area; for use in electrical and electronic equipment and components. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. There are different designs and materials for ID terminations in use. For this reason, only fundamental parameters of the termination are specified, while the performance requirements of the wire and the complete connection are specified in full detail. The purpose of this document is: – to determine the suitability of non-accessible ID connections under specified mechanical, electrical and atmospheric conditions; – to provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture. This second edition cancels and replaces the first edition, published in 1994, and its Amendment 1 (2000). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Transferred Clauses 9 to 13 into Annex A (informative). b) The figures were re-drawn for clarity.

Lötfreie Verbindungen - Teil 4: Nichtzugängliche Schneidklemmverbindungen - Allgemeine Anforderungen, Prüfverfahren und Anwendungshinweise

Connexions sans soudure - Partie 4: Connexions autodénudantes (CAD) non accessibles - Règles générales, méthodes d'essai et guide pratique

IEC 600352-4:2020 s'applique aux connexions CAD non accessibles pour lesquelles les essais et les mesures conformes aux Articles 6 à 8 sont appropriés et qui sont composées de: – contacts CAD de conception appropriée; – fils à conducteurs cylindriques massifs de diamètre nominal 0,25 mm à 3,6 mm; – fils à conducteurs divisés de section 0,05 mm2 à 10 mm2; pour l'utilisation dans les équipements et composants électriques et électroniques. Des informations sur les matières et des résultats dus à l'expérience industrielle y sont inclus en plus des méthodes d'essai pour assurer des connexions électriquement stables dans les conditions d'environnement prescrites. Il y a différentes conceptions et matières utilisées pour les contacts CAD. C'est pourquoi seuls les paramètres fondamentaux du contact sont spécifiés, tandis que les exigences des performances du fil et de la connexion terminée sont définies dans tous les détails. Le présent document a pour objet de: – déterminer la conformité des connexions CAD non accessibles dans des conditions mécaniques, électriques et atmosphériques spécifiées; – fournir un moyen de comparaison des résultats d'essai quand les outils utilisés pour faire les connexions, le cas échéant, sont de conceptions ou de fabrications différentes. Cette deuxième édition annule et remplace la première édition parue en 1994, et son Amendement 1 (2000). La présente édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: a) les Articles 9 à 13 ont été transférés à l'Annexe A (informative); b) les figures ont été retravaillées pour plus de clarté.

Nespajkani spoji - 4. del: Nedostopni izolacijsko prebodni spoji - Splošne zahteve, preskusne metode in praktični napotki (IEC 60352-4:2020)

General Information

Status
Published
Publication Date
30-Jul-2020
Technical Committee
Drafting Committee
Current Stage
6060 - Document made available - Publishing
Start Date
31-Jul-2020
Completion Date
31-Jul-2020

Relations

Buy Standard

Standard
EN IEC 60352-4:2020
English language
47 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2020
Nadomešča:
SIST EN 60352-4:2002
SIST EN 60352-4:2002/A1:2002
Nespajkani spoji - 4. del: Nedostopni izolacijsko prebodni spoji - Splošne zahteve,
preskusne metode in praktični napotki (IEC 60352-4:2020)
Solderless connections - Part 4: Non-accessible insulation displacement (ID)
connections - General requirements, test methods and practical guidance (IEC 60352-
4:2020)
Lötfreie elektrische Verbindungen - Teil 4: Lötfreie nichtzugängliche
Schneidklemmverbindungen - Allgemeine Anforderungen, Prüfverfahren und
Anwendungshinweise (IEC 60352-4:2020)
Connexions sans soudure - Partie 4: Connexions autodénudantes, non accessibles sans
soudure - Règles générales, méthodes d'essai et guide pratique (IEC 60352-4:2020)
Ta slovenski standard je istoveten z: EN IEC 60352-4:2020
ICS:
29.120.20 Spojni elementi Connecting devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 60352-4

NORME EUROPÉENNE
EUROPÄISCHE NORM
July 2020
ICS 29.120.20 Supersedes EN 60352-4:1994 and all of its amendments
and corrigenda (if any)
English Version
Solderless connections - Part 4: Non-accessible insulation
displacement (ID) connections - General requirements, test
methods and practical guidance
(IEC 60352-4:2020)
Connexions sans soudure - Partie 4: Connexions Lötfreie Verbindungen - Teil 4: Nichtzugängliche
autodénudantes (CAD) non accessibles - Règles générales, Schneidklemmverbindungen - Allgemeine Anforderungen,
méthodes d'essai et guide pratique Prüfverfahren und Anwendungshinweise
(IEC 60352-4:2020) (IEC 60352-4:2020)
This European Standard was approved by CENELEC on 2020-07-16. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 60352-4:2020 E

European foreword
The text of document 48B/2804/FDIS, future edition 2 of IEC 60352-4, prepared by SC 48B "Electrical
connectors" of IEC/TC 48 "Electrical connectors and mechanical structures for electrical and electronic
equipment" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2021-04-16
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2023-07-16
document have to be withdrawn
This document supersedes EN 60352-4:1994 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.

Endorsement notice
The text of the International Standard IEC 60352-4:2020 was approved by CENELEC as a European
Standard without any modification.

Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1  Where an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2  Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60050-581 - International Electrotechnical Vocabulary - - -
Part 581: Electromechanical components
for electronic equipment
IEC 60068-1 - Environmental testing - Part 1: General and EN 60068-1 -
guidance
IEC 60228 - Conductors of insulated cables EN 60228 -
IEC 60512-1 - Connectors for electrical and electronic EN IEC 60512-1 -
equipment - Tests and measurements - Part
1: Generic specification
IEC 60512-1-1 - Connectors for electronic equipment - Tests EN 60512-1-1 -
and measurements - Part 1-1: General
examination - Test 1a: Visual examination
IEC 60512-2-1 - Connectors for electronic equipment - Tests EN 60512-2-1 -
and measurements - Part 2-1: Electrical
continuity and contact resistance tests -
Test 2a: Contact resistance - Millivolt level
method
IEC 60512-2-2 - Connectors for electronic equipment - Tests EN 60512-2-2 -
and measurements - Part 2-2: Electrical
continuity and contact resistance tests -
Test 2b: Contact resistance - Specified test
current method
IEC 60512-2-5 - Connectors for electronic equipment - Tests EN 60512-2-5 -
and measurements - Part 2-5: Electrical
continuity and contact resistance tests -
Test 2e: Contact disturbance
IEC 60512-6-4 - Connectors for electronic equipment - Tests EN 60512-6-4 -
and measurements - Part 6-4: Dynamic
stress tests - Test 6d: Vibration (sinusoidal)
IEC 60512-9-2 - Connectors for electronic equipment - Tests EN 60512-9-2 -
and measurements - Part 9-2: Endurance
tests - Test 9b: Electrical load and
temperature
IEC 60512-11-1 - Connectors for electrical and electronic EN IEC 60512-11-1 -
equipment - Tests and measurements - Part
11-1: Climatic tests - Test 11a - Climatic
sequence
IEC 60512-11-4 - Connectors for electronic equipment - Tests EN 60512-11-4 -
and measurements - Part 11-4: Climatic
tests - Test 11d: Rapid change of
temperature
IEC 60512-11-7 - Connectors for electronic equipment - Tests EN 60512-11-7 -
and measurements - Part 11-7: Climatic
tests - Test 11g: Flowing mixed gas
corrosion test
IEC 60512-11-9 - Connectors for electronic equipment - Tests EN 60512-11-9 -
and measurements - Part 11-9: Climatic
tests - Test 11i: Dry heat
IEC 60512-11-10 - Connectors for electronic equipment - Tests EN 60512-11-10 -
and measurements - Part 11-10: Climatic
tests - Test 11j: Cold
IEC 60512-11-12 - Connectors for electronic equipment - Tests EN 60512-11-12 -
and measurements - Part 11-12: Climatic
tests - Test 11m: Damp heat, cyclic

IEC 60352-4 ®
Edition 2.0 2020-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Solderless connections –
Part 4: Non-accessible insulation displacement (ID) connections –

General requirements, test methods and practical guidance

Connexions sans soudure –
Partie 4: Connexions autodénudantes (CAD) non accessibles –

Règles générales, méthodes d'essai et guide pratique

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.120.20 ISBN 978-2-8322-8413-1

– 2 – IEC 60352-4:2020 © IEC 2020
CONTENTS
FOREWORD . 5
INTRODUCTION . 7
1 Scope . 9
2 Normative references . 9
3 Terms and definitions . 10
4 Workmanship . 14
5 Prerequisites for basic test schedule . 14
5.1 General . 14
5.2 Prerequisites for ID terminations . 14
5.2.1 Non-accessible ID terminations materials . 14
5.2.2 Non-accessible ID terminations dimensions . 14
5.2.3 Non-accessible ID terminations surface finishes . 14
5.2.4 Non-accessible ID terminations design features . 15
5.3 Prerequisites for wires and conductors. 15
5.3.1 Wire and conductors . 15
5.3.2 Conductor materials. 15
5.3.3 Wire and conductor dimensions . 15
5.3.4 Conductor surface finishes . 15
5.3.5 Wire insulation . 15
5.4 Non-accessible insulation displacement connections (ID connections) . 16
6 Testing . 16
6.1 Overview. 16
6.2 General . 16
6.3 Standard conditions for testing . 16
6.4 Preconditioning . 16
6.5 Recovery . 17
6.6 Specimen . 17
7 Tests . 17
7.1 General examination . 17
7.2 Mechanical tests . 17
7.2.1 General . 17
7.2.2 Bending of the cable/wire . 17
7.2.3 Vibration . 18
7.2.4 Repeated connection and disconnection, reusable non-accessible
ID terminations . 19
7.2.5 Microsection . 20
7.3 Electrical tests . 21
7.3.1 General . 21
7.3.2 Contact resistance . 21
7.3.3 Electrical load and temperature . 22
7.4 Climatic tests . 22
7.4.1 General . 22
7.4.2 Rapid change of temperature . 22
7.4.3 Climatic sequence . 23
7.4.4 Flowing mixed gas, corrosion test . 23
7.4.5 Damp heat, cyclic . 23

IEC 60352-4:2020 © IEC 2020 – 3 –
8 Test schedules .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.