EN 60601-2-36:2015
(Main)Medical electrical equipment - Part 2-36: Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy
Medical electrical equipment - Part 2-36: Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy
IEC 60601-2-36:2014 applies to basic safety and essential performance of equipment for extracorporeally induced lithotripsy including equipment for other medical applications of therapeutic extracorporeally induced focused pressure pulses. The applicability of this particular standard is limited to components directly involved in the lithotripsy treatment, such as, but not limited to, the generator of the pressure pulse, patient support device, and their interactions with imaging and monitoring devices. Other devices, such as patient treatment planning computers, X-ray and ultrasonic devices, are excluded from this standard, because they are treated in other applicable IEC standards. This particular standard does not apply to ultrasound physiotherapy equipment intended to be used for physiotherapy; abd to ultrasound equipment intended to be used for high intensity therapeutic ultrasound (HITU) and other therapy equipment as described in Annex AA. This second edition cancels and replaces the first edition of IEC 60601-2-36 published in 1997. This edition constitutes a technical revision to align structurally with IEC 60601-1:2005 and its Amendment1:2012.
Medizinische elektrische Geräte - Teil 2-36: Besondere Festlegungen für die Sicherheit einschließlich der wesentlichen Leistungsmerkmale von Geräten zur extrakorporal induzierten Lithotripsie
Appareils électromédicaux - Partie 2-36: Exigences particulières pour la sécurité de base et les performances essentielles des appareils pour lithotritie créée de façon extracorporelle
L'IEC 60601-2-36:2014 s'applique à la sécurité de base et aux performances essentielles des appareils pour lithotritie créée de façon extracorporelle, y compris des appareils pour d'autres applications médicales des impulsions de pression focalisées thérapeutiques créées de façon extracorporelle. La possibilité d'appliquer la présente norme particulière est limitée aux éléments directement en cause dans le traitement par lithotritie tels que, sans être exclusif, le générateur d'impulsions de pression, le dispositif supportant le patient, et leurs interactions avec les dispositifs d'imagerie et de surveillance. D'autres dispositifs, tels que les calculateurs organisant le traitement du patient, les dispositifs à rayonnement X et à ultrasons, sont exclus de la présente norme, car ils font l'objet d'autres normes IEC applicables. La présente norme particulière ne s'applique pas aux appareils à ultrasons prévus pour être utilisés en physiothérapie; et aux appareils à ultrasons prévus pour être utilisés en thérapie HITU (ultrasonore thérapeutique de haute intensité) et autres appareils de thérapie décrits à l'Annexe AA. Cette deuxième édition annule et remplace la première édition de l'IEC 60601-2-36 parue en 1997. Cette édition constitue une révision technique et s'aligne structurellement avec l'IEC 60601-1:2005 et son Amendement 1:2012.
Medicinska električna oprema - 2-36. del: Posebne zahteve za osnovno varnost in bistvene lastnosti pri zunajtelesni litotripsiji
Ta standard se uporablja za OSNOVNO VARNOST in BISTVENE LASTNOSTI opreme za ZUNAJTELESNO LITOTRIPSIJO, kot je opredeljena v točki 201.3.206, vključno z opremo za medicinsko uporabo terapevtskih zunajtelesno induciranih osredotočenih UDARNIH VALOV, v nadaljevanju ELEKTROMEDICINSKA OPREMA. Uporabnost tega standarda je omejena na komponente, ki so neposredno povezani z zdravljenjem LITOTRIPSIJE, kot so med drugim generator UDARNIH VALOV, naprava za podporo PACIENTU in njihove interakcije z napravami za slikanje in nadzor. Druge naprave, kot na primer računalniki za načrtovanje zdravljenja PACIENTA ter rentgenske in ultrazvočne naprave, ne spadajo v področje uporabe tega standarda, ker so obravnavane v drugih uporabljenih standardih IEC.
Ta standard se ne uporablja za:
– ULTRAZVOČNO FIZIOTERAPEVTSKO OPREMO, namenjeno za fizioterapijo;
– ULTRAZVOČNO opremo za visokointenzivne terapevtske ULTRAZVOČNE naprave (HITU) in drugo terapevtsko opremo, opisano v dodatku AA;
General Information
- Status
- Published
- Publication Date
- 21-May-2015
- Withdrawal Date
- 21-May-2018
- Technical Committee
- CLC/TC 62 - Electrical equipment in medical practice
- Drafting Committee
- IEC/SC 62D - IEC_SC_62D
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 22-May-2015
- Completion Date
- 22-May-2015
Relations
- Effective Date
- 28-Jan-2023
Overview
EN 60601-2-36:2015 (adopts IEC 60601-2-36:2014) is a European particular standard for medical electrical equipment used in extracorporeally induced lithotripsy (EIL). It defines requirements for the basic safety and essential performance of lithotripters and related components directly involved in treatment - for example, the generator of the focused pressure pulse and the patient support device, and their interactions with imaging and monitoring equipment. The standard aligns structurally with IEC 60601-1:2005/A1:2012 and supersedes the 1997 edition.
Key Topics
- Scope and applicability
- Covers equipment for extracorporeally induced lithotripsy and therapeutic extracorporeally induced focused pressure pulses.
- Limited to components directly involved in lithotripsy treatment; excludes devices covered by other standards (e.g., treatment-planning computers, X‑ray and ultrasonic imaging systems).
- Excludes ultrasound physiotherapy equipment and high intensity therapeutic ultrasound (HITU) as noted in Annex AA.
- Safety and performance requirements
- Requirements for basic electrical safety, mechanical safety, and protection against unwanted/excessive radiation and temperatures.
- Emphasis on accuracy of controls and instruments, identification and marking, and handling of hazardous situations and fault conditions.
- System interactions
- Rules for ME EQUIPMENT and ME SYSTEMS where lithotripter components interact with imaging/monitoring devices.
- Electromagnetic compatibility (EMC) requirements and testing (see IEC 60601-1-2 reference).
- Documentation and testing
- Identification, instructions, test methods, and normative references required for conformity assessment.
- Guidance annexes
- Informative Annex AA (guidance/rationale) and Annex BB (definitions of coordinates, focus and target location) support application and interpretation.
Applications
EN 60601-2-36:2015 is used by:
- Medical device manufacturers designing and producing lithotripters and direct treatment components.
- Test laboratories and conformity assessment bodies performing safety/performance verification and EMC testing.
- Regulatory and quality teams preparing technical documentation for CE marking and compliance with EU medical device directives.
- Clinical engineers and hospital procurement evaluating device safety, interoperability with imaging systems, and device labeling.
Practical uses include design validation, risk management, pre-market testing, and establishing safe interfaces between lithotripters and monitoring/imaging equipment.
Related Standards
- IEC 60601-1 (General requirements for basic safety and essential performance)
- IEC 60601-1-2 (EMC)
- IEC 61846 (Ultrasonics – pressure pulse lithotripters)
- IEC 61689, IEC 62555 (listed in Annex ZA as bibliographic references)
Compliance with EN 60601-2-36:2015 helps demonstrate conformity with applicable EU essential requirements for medical devices and supports safe, effective lithotripsy system design and deployment.
Frequently Asked Questions
EN 60601-2-36:2015 is a standard published by CLC. Its full title is "Medical electrical equipment - Part 2-36: Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy". This standard covers: IEC 60601-2-36:2014 applies to basic safety and essential performance of equipment for extracorporeally induced lithotripsy including equipment for other medical applications of therapeutic extracorporeally induced focused pressure pulses. The applicability of this particular standard is limited to components directly involved in the lithotripsy treatment, such as, but not limited to, the generator of the pressure pulse, patient support device, and their interactions with imaging and monitoring devices. Other devices, such as patient treatment planning computers, X-ray and ultrasonic devices, are excluded from this standard, because they are treated in other applicable IEC standards. This particular standard does not apply to ultrasound physiotherapy equipment intended to be used for physiotherapy; abd to ultrasound equipment intended to be used for high intensity therapeutic ultrasound (HITU) and other therapy equipment as described in Annex AA. This second edition cancels and replaces the first edition of IEC 60601-2-36 published in 1997. This edition constitutes a technical revision to align structurally with IEC 60601-1:2005 and its Amendment1:2012.
IEC 60601-2-36:2014 applies to basic safety and essential performance of equipment for extracorporeally induced lithotripsy including equipment for other medical applications of therapeutic extracorporeally induced focused pressure pulses. The applicability of this particular standard is limited to components directly involved in the lithotripsy treatment, such as, but not limited to, the generator of the pressure pulse, patient support device, and their interactions with imaging and monitoring devices. Other devices, such as patient treatment planning computers, X-ray and ultrasonic devices, are excluded from this standard, because they are treated in other applicable IEC standards. This particular standard does not apply to ultrasound physiotherapy equipment intended to be used for physiotherapy; abd to ultrasound equipment intended to be used for high intensity therapeutic ultrasound (HITU) and other therapy equipment as described in Annex AA. This second edition cancels and replaces the first edition of IEC 60601-2-36 published in 1997. This edition constitutes a technical revision to align structurally with IEC 60601-1:2005 and its Amendment1:2012.
EN 60601-2-36:2015 is classified under the following ICS (International Classification for Standards) categories: 11.040.01 - Medical equipment in general. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 60601-2-36:2015 has the following relationships with other standards: It is inter standard links to EN 60601-2-36:1997. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 60601-2-36:2015 is associated with the following European legislation: EU Directives/Regulations: 93/42/EEC; Standardization Mandates: M/023, M/295. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase EN 60601-2-36:2015 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2015
1DGRPHãþD
SIST EN 60601-2-36:1998
0HGLFLQVNDHOHNWULþQDRSUHPDGHO3RVHEQH]DKWHYH]DRVQRYQRYDUQRVWLQ
ELVWYHQHODVWQRVWLSUL]XQDMWHOHVQLOLWRWULSVLML
Medical electrical equipment - Part 2-36: Particular requirements for the basic safety and
essential performance of extracorporeally induced lithotripsy
Medizinische elektrische Geräte - Teil 2-36: Besondere Festlegungen für die Sicherheit
einschließlich der wesentlichen Leistungsmerkmale von Geräten zur extrakorporal
induzierten Lithotripsie
Appareils électromédicaux - Partie 2-36: Exigences particulières pour la sécurité de base
et les performances essentielles des appareils pour lithotritie créée de façon
extracorporelle
Ta slovenski standard je istoveten z: EN 60601-2-36:2015
ICS:
11.040.60 Terapevtska oprema Therapy equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 60601-2-36
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2015
ICS 11.040.01 Supersedes EN 60601-2-36:1997
English Version
Medical electrical equipment - Part 2-36: Particular requirements
for the basic safety and essential performance of equipment for
extracorporeally induced lithotripsy
(IEC 60601-2-36:2014)
Appareils électromédicaux - Partie 2-36: Exigences Medizinische elektrische Geräte - Teil 2-36: Besondere
particulières pour la sécurité de base et les performances Festlegungen für die Sicherheit einschließlich der
essentielles des appareils pour lithotritie créée de façon wesentlichen Leistungsmerkmal von Geräten zur
extracorporelle extrakorporal induzierten Lithotripsie
(IEC 60601-2-36:2014) (IEC 60601-2-36:2014)
This European Standard was approved by CENELEC on 2014-05-15. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60601-2-36:2015 E
Foreword
The text of document 62D/1109/FDIS, future edition 2 of IEC 60601-2-36, prepared by IEC/SC 62D
"Electromedical equipment", of IEC/TC 62 "Electrical equipment in medical practice" was submitted to
the IEC-CENELEC parallel vote and approved by CENELEC as EN 60601-2-36:2015.
The following dates are fixed:
(dop) 2015-11-22
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2018-05-22
• latest date by which the national
standards conflicting with the
document have to be withdrawn
This document supersedes EN 60601-2-36:1997.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
This document has been prepared under a mandate given to CENELEC by the European
Commission and the European Free Trade Association, and supports essential requirements of EU
Directive(s).
For the relationship with EU Directive see informative Annex ZZ, which is an integral part of this
document.
Endorsement notice
The text of the International Standard IEC 60601-2-36:2014 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
IEC 61689:2013 NOTE Harmonized as EN 61689:2013 (not modified).
IEC 62555 NOTE Harmonized as EN 62555.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu
Annex ZA of EN 60601-1:2006 applies with the following exceptions:
Publication Year Title EN/HD Year
Replacement:
IEC 60601-1-2 2007 Medical electrical equipment -- Part 1-2: EN 60601-1-2 2007
(mod) General requirements for basic safety and
essential performance - Collateral
standard: Electromagnetic compatibility -
Requirements and tests
+AC 2010
Addition:
IEC 60601-1 2005 Medical electrical equipment -- Part 1: EN 60601-1 2006
General requirements for basic safety and
essential performance
+AC 2010
+AC 2014
+A11 2011
+A1 2012 +A1 2013
IEC 60601-2-5 2009 Medical electrical equipment -- Part 2-5: - -
Particular requirements for the basic safety
and essential performance of ultrasonic
physiotherapy equipment
IEC 61846 1998 Ultrasonics - Pressure pulse lithotripters - EN 61846 1998
Characteristics of fields
Annex ZZ
(informative)
Coverage of Essential Requirements of EU Directives
This European Standard has been prepared under a mandate given to CENELEC by the
European Commission and the European Free Trade Association, and within its scope the
Standard covers all relevant essential requirements given in Annex I of EU Directive 93/42/EEC of
14 June 1993 concerning medical devices.
Compliance with this standard provides one means of conformity with the specified essential
requirements of the Directive concerned.
WARNING: Other requirements and other EU Directives can be applied to the products falling
within the scope of this standard.
IEC 60601-2-36 ®
Edition 2.0 2014-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Medical electrical equipment –
Part 2-36: Particular requirements for the basic safety and essential performance
of equipment for extracorporeally induced lithotripsy
Appareils électromédicaux –
Partie 2-36: Exigences particulières pour la sécurité de base et les performances
essentielles des appareils pour lithotritie créée de façon extracorporelle
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX S
ICS 11.040.01 ISBN 978-2-8322-1498-5
– 2 – IEC 60601-2-36:2014 IEC 2014
CONTENTS
FOREWORD . 3
INTRODUCTION . 6
201.1 Scope, object and related standards . 7
201.2 Normative references . 8
201.3 Terms and definitions . 9
201.4 General requirements . 10
201.5 General requirements for testing ME EQUIPMENT . 10
201.6 Classification of ME EQUIPMENT and ME SYSTEMS . 11
201.7 ME EQUIPMENT identification, marking and documents . 11
201.8 Protection against electrical HAZARDS from ME EQUIPMENT . 12
201.9 Protection against MECHANICAL HAZARDS OF ME EQUIPMENT and ME SYSTEMS . 12
201.10 Protection against unwanted and excessive radiation HAZARDS . 13
201.11 Protection against excessive temperatures and other HAZARDS . 13
201.12 Accuracy of controls and instruments and protection against hazardous
outputs . 13
201.13 HAZARDOUS SITUATIONS and fault conditions for ME EQUIPMENT . 14
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS) . 15
201.15 Construction of ME EQUIPMENT . 15
201.16 ME SYSTEMS . 15
201.17 ELECTROMAGNETIC COMPATIBILITY of ME EQUIPMENT and ME SYSTEMS . 15
202 * ELECTROMAGNETIC COMPATIBILITY – Requirements and tests . 15
Annexes . 15
Annex AA (informative) Particular guidance and rationale . 16
Annex BB (informative) Definition of coordinates, FOCUS and TARGET LOCATION . 17
Bibliography . 18
Index of defined terms used in this particular standard . 20
Figure BB.1 – Geometrical FOCUS distribution . 17
IEC 60601-2-36:2014 IEC 2014 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
MEDICAL ELECTRICAL EQUIPMENT –
Part 2-36: Particular requirements for the basic safety and essential
performance of equipment for extracorporeally induced lithotripsy
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International standard IEC 60601-2-36 has been prepared by IEC subcommittee 62D:
Electromedical equipment, of IEC technical committee 62: Electrical equipment in medical
practice.
This second edition cancels and replaces the first edition of IEC 60601-2-36 published in
1997. This edition constitutes a technical revision to align structurally with IEC 60601-1:2005
and its Amendment 1:2012).
– 4 – IEC 60601-2-36:2014 IEC 2014
The text of this particular standard is based on the following documents:
FDIS Report on voting
62D/1109/FDIS 62D/1122/RVD
Full information on the voting for the approval of this particular standard can be found in the
report on voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
In this standard, the following print types are used:
– Requirements and definitions: roman type.
– Test specifications: italic type.
– Informative material appearing outside of tables, such as notes, examples and references: in smaller type.
Normative text of tables is also in a smaller type.
– TERMS DEFINED IN CLAUSE 3 OF THE GENERAL STANDARD, IN THIS PARTICULAR STANDARD OR AS
NOTED: SMALL CAPITALS.
In referring to the structure of this standard, the term
– “clause” means one of the numbered divisions within the table of contents, inclusive of all
subdivisions (e.g. Clause 7 includes subclauses 7.1, 7.2, etc.);
– “subclause” means a numbered subdivision of a clause (e.g. 7.1, 7.2 and 7.2.1 are all
subclauses of Clause 7).
References to clauses within this standard are preceded by the term “Clause” followed by the
clause number. References to subclauses within this particular standard are by number only.
In this standard, the conjunctive “or” is used as an “inclusive or” so a statement is true if any
combination of the conditions is true.
The verbal forms used in this standard conform to usage described in Annex H of the ISO/IEC
Directives, Part 2. For the purposes of this standard, the auxiliary verb:
– “shall” means that compliance with a requirement or a test is mandatory for compliance
with this standard;
– “should” means that compliance with a requirement or a test is recommended but is not
mandatory for compliance with this standard;
– “may” is used to describe a permissible way to achieve compliance with a requirement or
test.
An asterisk (*) as the first character of a title or at the beginning of a paragraph or table title
indicates that there is guidance or rationale related to that item in Annex AA.
A list of all parts of the IEC 60601 series, published under the general title Medical electrical
equipment, can be found on the IEC website.
IEC 60601-2-36:2014 IEC 2014 – 5 –
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 6 – IEC 60601-2-36:2014 IEC 2014
INTRODUCTION
This particular standard concerns the BASIC SAFETY and ESSENTIAL PERFORMANCE of equipment
for EXTRACORPOREALLY INDUCED LITHOTRIPSY. It amends and supplements IEC 60601-1/A1:2012
(Ed. 3.1): Medical electrical equipment – Part 1: General requirements for basic safety and
essential performance), hereinafter referred to as the general standard.
The aim of this second edition is to bring this particular standard up to date with reference to
the third edition of the general standard through reformatting and technical changes.
The requirements of this particular standard take priority over those of the general standard.
A “General guidance and rationale” for the more important requirements of this particular
standard is included in Annex AA. It is considered that knowledge of the reasons for these
requirements will not only facilitate the proper application of the standard but will, in due
course, expedite any revision necessitated by changes in clinical practice or as a result of
developments in technology. However, Annex AA does not form part of the requirements of
this standard.
IEC 60601-2-36:2014 IEC 2014 – 7 –
MEDICAL ELECTRICAL EQUIPMENT –
Part 2-36: Particular requirements for basic safety and essential
performance of equipment for extracorporeally induced lithotripsy
201.1 Scope, object and related standards
Clause 1 of the general standard applies, except as follows:
201.1.1 Scope
Replacement:
This particular standard applies to BASIC SAFETY and ESSENTIAL PERFORMANCE of equipment for
EXTRACORPOREALLY INDUCED LITHOTRIPSY as defined in 201.3.206 including equipment for
other medical applications of therapeutic extracorporeally induced focused PRESSURE PULSES,
hereafter referred to as ME EQUIPMENT. The applicability of this particular standard is limited to
components directly involved in the LITHOTRIPSY treatment, such as, but not limited to, the
generator of the PRESSURE PULSE, PATIENT support device, and their interactions with imaging
and monitoring devices. Other devices, such as PATIENT treatment planning computers, X-ray
and ultrasonic devices, are excluded from this standard, because they are treated in other
applicable IEC standards.
This particular standard does not apply to:
– ULTRASOUND PHYSIOTHERAPY EQUIPMENT intended to be used for physiotherapy;
– ULTRASOUND equipment intended to be used for high intensity therapeutic ULTRASOUND
(HITU) and other therapy equipment as described in Annex AA;
201.1.2 * Object
Replacement:
The object of this particular standard is to establish particular BASIC SAFETY and ESSENTIAL
PERFORMANCE requirements of equipment for EXTRACORPOREALLY INDUCED LITHOTRIPSY as
defined in 201.3.206 including equipment for other medical applications of therapeutic
extracorporeal focused PRESSURE PULSES.
201.1.3 Collateral standards
Addition:
This particular standard refers to those applicable collateral standards that are listed in
Clause 2 of the general standard and Clause 201.2 of this particular standard.
IEC 60601-1-2:2007 applies as modified in Clause 202. IEC 60601-1-3 and IEC 60601-1-10
do not apply. All other published collateral standards in the IEC 60601-1 series apply as
published.
—————————
The general standard is IEC 60601-1:2005/A1:2012, Medical electrical equipment – Part 1: General
requirements for basic safety and essential performance.
IEC 60601-1-10:2007, Medical electrical equipment – Part 1-10: General requirements for basic safety and
essential performance – Collateral Standard: Requirements for the development of physiologic closed-loop
controllers
– 8 – IEC 60601-2-36:2014 IEC 2014
201.1.4 Particular standards
Replacement:
In the IEC 60601 series, particular standards may modify, replace or delete requirements
contained in the general standard and collateral standards as appropriate for the particular
ME EQUIPMENT under consideration, and may add other BASIC SAFETY and ESSENTIAL
PERFORMANCE requirements.
A requirement of a particular standard takes priority over the general standard.
For brevity, IEC 60601-1 is referred to in this particular standard as the general standard.
Collateral standards are referred to by their document number.
The numbering of clauses and subclauses of this particular standard corresponds to that of
the general standard with the prefix “201” (e.g. 201.1 in this standard addresses the content
of Clause 1 of the general standard) or applicable collateral standard with the prefix “20x”
where x is the final digit(s) of the collateral standard document number (e.g. 202.4 in this
particular standard addresses the content of Clause 4 of the IEC 60601-1-2 collateral
standard, 203.4 in this particular standard addresses the content of Clause 4 of the
IEC 60601-1-3 collateral standard, etc.). The changes to the text of the general standard are
specified by the use of the following words:
"Replacement" means that the clause or subclause of the general standard or applicable
collateral standard is replaced completely by the text of this particular standard.
"Addition" means that the text of this particular standard is additional to the requirements of
the general standard or applicable collateral standard.
"Amendment" means that the clause or subclause of the general standard or applicable
collateral standard is amended as indicated by the text of this particular standard.
Subclauses, figures or tables which are additional to those of the general standard are
numbered starting from 201.101. However due to the fact that definitions in the general
standard are numbered 3.1 through 3.139, additional definitions in this
...
SIST EN 60601-2-36:2015は、体外で誘発される結石破砕用の医療電気機器に関する特定の要件を示した重要な規格です。この規格は、体外結石破砕治療に用いられる機器の基本的な安全性と本質的な性能に焦点を当てています。対象となる機器は、圧力パルス発生器、患者支持装置、画像診断およびモニタリング機器との相互作用を含む、治療に直接関与するコンポーネントに限定されています。 この標準化文書の強みは、特に医療機器の安全性を強化する点にあります。体外結石破砕に関連する機器の設計および運用において、患者の安全を確保するための具体的な指針を提供します。また、IEC 60601-1:2005およびその改正に整合する形で技術的改訂が行われており、新たな技術や医療現場でのニーズに対応した内容となっています。 EN 60601-2-36:2015の適用範囲は明確で、リスク管理や装置の性能を考慮した基準が設定されることで、医療機器メーカーやユーザーに対して実用的な枠組みを提示しています。標準は、医療機器の設計や検査において重要な役割を果たし、特に体外での治療において必要不可欠な指針となっています。 この規格は、他の関連するIECの規格とは異なり、結石破砕に特化しているため、体外療法および高強度治療用超音波機器に関しては適用されません。この限定的な適用範囲は、規格の明瞭さと特異性をもたらしており、特定の医療機器に対する信頼性を高める要因となっています。 全体として、SIST EN 60601-2-36:2015は、体外結石破砕装置の安全性と効率性を確保するための強固な基盤を提供し、医療機器の設計と実装における重要な参考資料であると言えます。
La norme SIST EN 60601-2-36:2015, qui est un document essentiel pour le domaine de l'équipement médical, se concentre sur les exigences particulières relatives à la sécurité de base et à la performance essentielle des équipements pour la lithotripsie induite extracorporellement. Cette norme s'applique spécifiquement aux équipements destinés à la lithotripsie, ce qui en fait un référentiel clé pour les professionnels de santé impliqués dans cette procédure. L'étendue de cette norme est clairement définie. Elle couvre les équipements utilisés pour la lithotripsie, y compris, entre autres, le générateur d'impulsions de pression et les dispositifs de soutien du patient, ainsi que leurs interactions avec les dispositifs d'imagerie et de surveillance. Cette précision sur les composants zéner une sécurité accrue dans l'utilisation clinique de ces dispositifs. En excluant explicitement d'autres appareils comme les ordinateurs de planification de traitement, les dispositifs à rayons X et ultrasoniques, la norme se concentre sur les éléments directement liés à la lithotripsie, assurant ainsi une approche ciblée et cohérente. Un point fort majeur de la norme SIST EN 60601-2-36:2015 est sa mise à jour par rapport à la première édition de 1997. Cette révision technique vise à harmoniser la structure de la norme avec celle de l'IEC 60601-1:2005 et son Amendement 1:2012, ce qui améliore la clarté et l'uniformité des exigences. Cette alignement structurel permet également d'assurer une meilleure intégration et compréhension des normes au sein des multiples dispositifs médicaux. La pertinence de cette norme est accentuée par son accent sur la sécurité et la performance essentiel des équipements médicaux pour lithotripsie. En définissant des critères clairs, la norme contribue à la protection des patients et à l'amélioration des résultats cliniques, assurant que les équipements utilisés répondent aux standards requis pour un traitement sûr et efficace. En conclusion, la norme SIST EN 60601-2-36:2015 s'avère être une ressource incontournable pour les fabricants, les exploitants et les professionnels de santé impliqués dans la lithotripsie extracorporelle, soulignant son importance dans le cadre des équipements médicaux modernes.
The standard EN 60601-2-36:2015 addresses the basic safety and essential performance of medical electrical equipment used in extracorporeally induced lithotripsy. Its defined scope ensures that it specifically targets the components directly engaged in the lithotripsy process, including pressure pulse generators and patient support devices, while maintaining a clear distinction from other medical devices by excluding them from its applicability. This focus enhances the reliability and safety of lithotripsy equipment, which is crucial for effective patient treatment. One of the key strengths of this standard is its alignment with the broader IEC 60601-1:2005 framework, incorporating necessary technical revisions that help harmonize safety requirements across related medical equipment standards. This structural alignment not only simplifies compliance processes for manufacturers but also enhances the overall safety protocols within the field of medical electrical equipment. Additionally, the specific exclusions of ultrasound physiotherapy equipment and HITU devices from this standard ensure that each category of equipment can be regulated under the most relevant and appropriate standards, which optimizes the safety assessment process. The relevance of EN 60601-2-36:2015 cannot be overstated, given the increasing reliance on minimally invasive procedures such as lithotripsy in modern medical practice. The standard plays a crucial role in defining the essential performance parameters for devices employing focused pressure pulses, ensuring that they operate safely and effectively during patient treatment. By emphasizing both basic safety and performance within its scope, the standard demonstrates a comprehensive approach to patient care, making it indispensable for manufacturers and healthcare providers navigating the complexities of medical electrical equipment. Overall, EN 60601-2-36:2015 stands out as a vital standard in the realm of medical electrical equipment, particularly for extracorporeally induced lithotripsy, and serves as a trusted guideline for ensuring the safety and efficacy of these critical therapeutic devices.
EN 60601-2-36:2015 표준은 체외로 유도된 체석쇄기기( lithotripsy) 장비의 기본 안전성 및 필수 성능에 대한 특정 요구 사항을 다루고 있습니다. 이 표준의 범위는 체외에서 유도된 충격 압력을 이용한 치료 응용을 포함하여 lithotripsy 관련 장비가 기본 안전성과 필수 성능 기준을 충족해야 함을 명확히 하고 있습니다. 특히, 이 표준은 압력 펄스 발생기, 환자 지지 장치와 같은 치료의 기본 구성 요소에 적용되며, 이들 장치가 이미징 및 모니터링 장비와 상호 작용하는 경우를 포함합니다. 표준의 강점으로는 고급 기술 사양이 반영되어 있어, 해당 장비들이 인체에 안전하고 효과적으로 작동하도록 보장하는 것입니다. 또한, 이 표준은 1997년에 발표된 1판을 취소하고 대체한 2판으로, IEC 60601-1:2005 및 개정안 1:2012와의 구조적 정렬을 위해 기술적으로 수정되었습니다. 이러한 기술적 수정은 장비의 안전성과 성능 기준을 더욱 강화하여, 의료 환경에서의 신뢰성을 높입니다. EN 60601-2-36:2015는 특정한 치료 장비에 대한 명확한 지침을 제공하는 만큼, 관련 의료 기기 제조업체 및 의료기관에 매우 중요한 콘텐츠로 자리잡고 있습니다. 이 표준의 적용 범위와 강점은 체외로 유도된 lithotripsy 치료의 안전성과 효과성을 보장하며, 의료기기의 품질 향상에 기여하는 데 중요한 역할을 합니다.
Die Norm EN 60601-2-36:2015 behandelt die grundlegende Sicherheit und die wesentliche Leistung von medizinischen elektrischen Geräten, die für die extrakorporale Lithotripsie eingesetzt werden. Sie stellt sicher, dass die Geräte, die für diese spezifische Behandlung konzipiert sind, sowohl sicher als auch leistungsfähig sind und dabei strengen Anforderungen entsprechen. Die Reichweite dieser Norm konzentriert sich auf die Sicherheits- und Leistungskriterien von Geräten, die direkt in den Lithotripsie-Prozess involviert sind, wie beispielsweise Druckpulse-Generatoren und Patiententrägersysteme. Dies gewährleistet eine sichere Interaktion zwischen den Behandlungsvorrichtungen und den bildgebenden sowie Überwachungsgeräten. Die gezielte Fokussierung auf diese spezifischen Komponenten stärkt die Relevanz und Anwendbarkeit der Norm für medizinische Fachkräfte und Hersteller, die sicherstellen müssen, dass ihre Geräte die geforderten Standards erfüllen. Ein wesentlicher Vorteil dieser Norm ist die technische Überarbeitung, die eine Angleichung an die Struktur der IEC 60601-1:2005 und deren Änderung 1:2012 mit sich bringt. Dies führt zu einer verbesserten Konsistenz und Klarheit in der Anwendung der Norm, was sowohl den Herstellern als auch den Anwendern zugutekommt. Die Norm schließt Geräte wie Patientenbehandlungsplanungscomputer sowie Röntgen- und Ultraschallgeräte aus, was die Zielgerichtetheit und Spezialisierung der Norm weiter unterstreicht. Ein weiterer positiver Aspekt ist die Streichung und der Ersatz der ersten Ausgabe von IEC 60601-2-36 aus dem Jahr 1997. Die Aktualisierung bietet den neuesten Stand der Technik und berücksichtigt aktuelle Entwicklungen im Bereich der Lithotripsie. Durch die Fokussierung auf die grundlegende Sicherheit und die wesentliche Leistung wird das Risiko für Patienten während der Behandlung verringert und die Effizienz der Behandlung insgesamt gesteigert. Insgesamt zeigt die EN 60601-2-36:2015, dass sie eine unerlässliche Norm für Sicherheit und Leistung in der extrakorporalen Lithotripsie darstellt, die sowohl die Bedürfnisse der Hersteller als auch die Anforderungen der klinischen Praxis erfüllt. Die Relevanz dieser Norm ist unbestritten, da sie einen hohen Standard für sicherheitsrelevante Geräte in der modernen Medizin setzt.










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...