EN 60661:2001/A2:2005
(Amendment)Methods for measuring the performance of electric household coffee makers
Methods for measuring the performance of electric household coffee makers
Verfahren zur Messung der Gebrauchseigenschaften elektrischer Haushalt-Kaffeebereiter
Méthodes de mesure de l'aptitude à la fonction des cafetières électriques à usage domestique
Metode za merjenje lastnosti električnih gospodinjskih aparatov za kavo (IEC 60661:1999/A2:2005)
General Information
Relations
Standards Content (Sample)
SLOVENSKI SIST EN 60661:2002/A2:2006
STANDARD
may 2006
Metode za merjenje lastnosti električnih gospodinjskih aparatov za kavo (IEC
60661:1999/A2:2005)
Methods for measuring the performance of electric household coffee makers (IEC
60661:1999/A2:2005)
ICS 97.040.50 Referenčna številka
© Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno
EUROPEAN STANDARD EN 60661/A2
NORME EUROPÉENNE
EUROPÄISCHE NORM December 2005
ICS 97.040.50
English version
Methods for measuring the performance
of electric household coffee makers
(IEC 60661:1999/A2:2005)
Méthodes de mesure de l'aptitude Verfahren zur Messung der
à la fonction des cafetières électriques Gebrauchseigenschaften elektrischer
à usage domestique Haushalt-Kaffeebereiter
(CEI 60661:1999/A2:2005) (IEC 60661:1999/A2:2005)
This amendment A2 modifies the European Standard EN 60661:2001; it was approved by CENELEC on
2005-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60661:2001/A2:2005 E
Foreword
The text of document 59L/21/FDIS, future amendment 2 to IEC 60661:1999, prepared by SC 59L,
Small household appliances, of IEC TC 59, Performance of household electrical appliances, was
submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A2 to
EN 60661:2001 on 2005-12-01.
The following dates were fixed:
– latest date by which the amendment has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2006-09-01
– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2008-12-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of amendment 2:2005 to the International Standard IEC 60661:1999 was approved by
CENELEC as an amendment to the European Standard without any modification.
__________
- 3 - EN 60661:2001/A2:2005
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
Add:
Publication Year Title EN/HD Year
1) 2)
IEC 60584-2 - Thermocouples EN 60584-2 1993
Part 2: Tolerances
1)
Undated reference.
2)
Valid edition at date of issue.
NORME CEI
INTERNATIONALE
IEC
INTERNATIONAL
STANDARD
AMENDEMENT 2
AMENDMENT 2
2005-11
Amendement 2
Méthodes de mesure de l'aptitude à la fonction
des cafetières électriques à usage domestique
Amendment 2
Methods for measuring the performance
of electric household coffee makers
IEC 2005 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
F
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
60661 Amend. 2 IEC:2005 – 3 –
FOREWORD
This amendment has been prepared by subcommittee 59L: Small household appliances, of
IEC technical committee 59: Performance of household electrical appliances.
The text of this amendment is based on the following documents:
FDIS Report on voting
59L/21/FDIS 59L/23/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
___________
Page 3
CONTENTS
Add the title of new Clause 27 as follows:
27 Steam function to froth-up milk and to heat-up water
Page 5
2 Normative references
Add to the existing list, the title of the following standard:
IEC 60584-2, Thermocouples – Part 2: Tolerances
Page 7
5 List of measurements and assessment of performance
Add, to the existing list, the following new items:
– Energy consumption (Clause 26)
– Steam function to froth-up milk and to heat-up water (Clause 27).
60661 Amend. 2 IEC:2005 – 5 –
Page 21
Add, after Clause 26, the following new Clause 27:
27 Steam function to froth-up milk and to heat-up water
The test procedure is considered as applicable for reproducible testing.
27.1 Steam function to froth-up milk
A glass container with a thickness of about 2 mm having an inner diameter of 80 mm + 2 mm
and a height of 75 mm + 2 mm is placed perpendicular and centered below the steam tube of
the appliance.
The distance of the outlet of the
...