EN 50464-2-3:2007
(Main)Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-3: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 2 for use on distribution transformers meeting the requirements of EN 50464-2-1
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-3: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 2 for use on distribution transformers meeting the requirements of EN 50464-2-1
Cable boxes described in this European Standard correspond to cable boxes Type 2 in EN 50464-2-1 and are suitable for assembly on the cover of oil-immersed distribution transformers meeting the requirements of EN 50464-2-1. Cable boxes are air-filled, metal- or non-metal enclosed, for high- and/or low-voltage connections in the following variations: 1.1 High-voltage side a) Connection directly to bushings; b) Connection via busbar system. 1.2 Low-voltage side a) Connection directly to bushings (maximum of four connectors per bushing); b) Connection via busbar system.
Ölgefüllte Drehstrom-Verteilungstransformatoren 50 Hz, 50 kVA bis 2 500 kVA, mit einer höchsten Spannung für Betriebsmittel bis 36 kV - Teil 2-3: Verteilungstransformatoren mit Kabelanschlusskästen auf der Ober- und/oder Unterspannungsseite - Kabelanschlusskästen Typ 2 für Verteilungstransformatoren nach EN 50464-2-1
Die in dieser Norm beschriebenen Kabelanschlusskästen entsprechen den Kabelanschlusskästen Typ 2 nach EN 50464-2-1 und sind geeignet für den Aufbau auf dem Deckel von ölgefüllten Verteilungstransformatoren, die den Anforderungen nach EN 50464-2-1 entsprechen. Die Kabelanschlusskästen sind luftgefüllt, mit metallischem oder nicht metallischem Gehäuse, für die Ober- und/oder die Unterspannungsanschlüsse auf eine der folgenden Arten: 1.1 Oberspannungsseite a) Direkter Anschluss an die Durchführungen; b) Anschluss über Sammelschienen. 1.2 Unterspannungsseite a) Direkter Anschluss an die Durchführung (höchstens vier Leiter je Durchführung); b) Anschluss über Sammelschienen.
Transformateurs triphasés de distribution immergés dans l'huile, 50 Hz, de 50 kVA à 2 500 kVA, de tension la plus élevée pour le matériel ne dépassant pas 36 kV - Partie 2-3: Transformateurs de distribution raccordés par boîtes à câble côté haute tension et/ou côté basse tension - Boîtes à câbles de type 2 pour utilisation sur transformateurs de distribution conformes aux exigences de la EN 50464-2-1
Les boîtes à câble décrites dans la présente Norme Européenne correspondent aux boîtes à câble de Type 2 de la EN 50464-2-1 et sont adaptées pour être montées sur le couvercle des transformateurs de distribution immergés dans l'huile répondant aux prescriptions de la EN 50464-2-1. Les boîtes à câble sont remplies d'air, constituées par des boîtiers à enveloppe métallique ou non, destinées aux connexions haute et/ou basse tension dans les configurations suivantes: 1.1 Côté haute tension a) Connexion directe aux traversées; b) Connexion via un système de jeu de barre. 1.2 Côté basse tension a) Connexion directe aux traversées (au maximum 4 connecteurs par traversée); b) Connexion via un système de jeu de barre.
Trifazni oljni distribucijski transformatorji frekvenco 50 Hz z močjo od 50 do 2500 kVA in opremo do napetosti 36 kV - 2-3. del: Distribucijski transformatorji s kabelskimi ohišji na visokonapetostni oziroma nizkonapetostni strani - Kabelska ohišja tip 2 za distribucijske transformatorje, ki izpolnjujejo zahteve standarda EN 50464-2-1
Kabelske omarice, opisane v tem Evropskem standardu ustrezajo kabelskim omaricam Tipa 2 v EN 50464-2-1 in so primerne za montažo na pokrovu oljnih distribucijskih transformatorev, ki sledijo zahtevam EN 50464-2-1. Kabelske omarice so polnjene z zrakom, v kovinskih ali nekovinskih okrovih, za visokonapetostne oziroma nizkonapetostne povezave v naslednjih variantah: 1.1 visokonapetostna stran: a) povezava direktno na skoznjik, b) povezava na zbiralnični sistem. 1.2 nizkonapetostna stran: a) povezava direktno na skoznjik (maksimalno štirje priključki na en skoznjik), b) povezava na zbiralnični sistem.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2007
1DGRPHãþD
SIST HD 428.2.3 S1:1999
7ULID]QLROMQLGLVWULEXFLMVNLWUDQVIRUPDWRUML]DIUHNYHQFR+]PRþLRGN9$GR
N9$LQRSUHPRGRQDSHWRVWLN9±GHO'LVWULEXFLMVNLWUDQVIRUPDWRUMLV
NDEHOVNLPLRPDULFDPLQDYLVRNRQDSHWRVWQLR]LURPDQL]NRQDSHWRVWQLVWUDQL±
.DEHOVNHRPDULFHWLS]DGLVWULEXFLMVNHWUDQVIRUPDWRUMHNLL]SROQMXMHMR]DKWHYH
VWDQGDUGD(1
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA
with highest voltage for equipment not exceeding 36 kV -- Part 2-3: Distribution
transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes
type 2 for use on distribution transformers meeting the requirements of EN 50464-2-1
Ölgefüllte Drehstrom-Verteilungstransformatoren 50 Hz, 50 kVA bis 2 500 kVA, mit einer
höchsten Spannung für Betriebsmittel bis 36 kV -- Teil 2-3: Verteilungstransformatoren
mit Kabelanschlusskästen auf der Ober- und/oder Unterspannungsseite -
Kabelanschlusskästen Typ 2 für Verteilungstransformatoren nach EN 50464-2-1
Transformateurs triphasés de distribution immergés dans l'huile, 50 Hz, de 50 kVA a 2
500 kVA, de tension la plus élevée pour le matériel ne dépassant pas 36 kV -- Partie 2-3:
Transformateurs de distribution raccordés par boîtes a câble côté haute tension et/ou
côté basse tension - Boîtes a câbles de type 2 pour utilisation sur transformateurs de
distribution conformes aux exigences de la EN 50464-2-1
Ta slovenski standard je istoveten z: EN 50464-2-3:2007
ICS:
29.180 Transformatorji. Dušilke Transformers. Reactors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 50464-2-3
NORME EUROPÉENNE
April 2007
EUROPÄISCHE NORM
ICS 29.180 Supersedes HD 428.2.3 S1:1998
English version
Three-phase oil-immersed distribution transformers
50 Hz, from 50 kVA to 2 500 kVA with highest voltage
for equipment not exceeding 36 kV -
Part 2-3: Distribution transformers with cable boxes
on the high-voltage and/or low-voltage side -
Cable boxes type 2 for use on distribution transformers
meeting the requirements of EN 50464-2-1
Transformateurs triphasés de distribution Ölgefüllte
immergés dans l'huile, 50 Hz, de 50 kVA Drehstrom-Verteilungstransformatoren
à 2 500 kVA, de tension la plus élevée 50 Hz, 50 kVA bis 2 500 kVA,
pour le matériel ne dépassant pas 36 kV - mit einer höchsten Spannung
Partie 2-3: Transformateurs de distribution für Betriebsmittel bis 36 kV -
raccordés par boîtes à câble côté haute Teil 2-3: Verteilungstransformatoren
tension et/ou côté basse tension - mit Kabelanschlusskästen auf der
Boîtes à câbles de type 2 Ober- und/oder Unterspannungsseite -
pour utilisation sur transformateurs Kabelanschlusskästen Typ 2
de distribution conformes aux exigences für Verteilungstransformatoren
de la EN 50464-2-1 nach EN 50464-2-1
This European Standard was approved by CENELEC on 2006-12-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50464-2-3:2007 E
Foreword
The text of the Harmonization Document HD 428.2.3 S1:1998, prepared by the Technical Committee
CENELEC TC 14, Power transformers, was submitted to the formal vote for conversion into a
European Standard and was approved by CENELEC as EN 50464-2-3 on 2006-12-01.
The following date was fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2007-12-01
The EN 50464 series consists of the following parts, under the general title “Three-phase oil-immersed
distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not
exceeding 36 kV”:
Part 1 General requirements
Part 2-1 Distribution transformers with cable boxes on the high-voltage and/or low-voltage
side – General requirements
Part 2-2 Distribution transformers with cable boxes on the high-voltage and/or low-voltage
side – Cable boxes type 1 for use on distribution transformers meeting the
requirements of EN 50464-2-1
Part 2-3 Distribution transformers with cable boxes on the high-voltage and/or low-voltage
side – Cable boxes type 2 for use on distribution transformers meeting the
requirements of EN 50464-2-1
Part 3 Determination of the power rating of a transformer loaded with non-sinusoidal
currents
Part 4 Requirements and tests concerning pressurised corrugated tanks
- 3 - EN 50464-2-3:2007
Contents
1 Scope.4
1.1 High-voltage side. 4
1.2 Low-voltage side . 4
2 Normative references.4
3 Definitions.
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.