Electromagnetic compatibility (EMC) - Part 4-14: Testing and measurement techniques - Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase

Elektromagnetische Verträglichkeit (EMV) - Teil 4-14: Prüf- und Messverfahren - Prüfung der Störfestigkeit von Geräten und Einrichtungen mit einem Eingangsstrom bis einschließlich 16 A je Leiter gegen Spannungsschwankungen

Compatibilité électromagnétique (CEM) - Partie 4-14: Techniques d'essai et de mesure - Essai d'immunité aux fluctuations de tension pour le matériel dont le courant d'entrée est inférieur ou égal à 16 A par phase

Elektromagnetna združljivost (EMC) - 4-14. del: Preskusne in merilne tehnike - Preskus odpornosti proti napetostnemu kolebanju (IEC 61000-4-14:1999/A2:2009)

General Information

Status
Published
Publication Date
20-Aug-2009
Withdrawal Date
30-Jun-2012
Drafting Committee
IEC/SC 77A - IEC_SC_77A
Parallel Committee
IEC/SC 77A - IEC_SC_77A
Current Stage
6060 - Document made available - Publishing
Start Date
21-Aug-2009
Completion Date
21-Aug-2009

Relations

Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
29-Jan-2023

Overview

EN 61000-4-14:1999/A2:2009 is a European standard developed by CLC (CENELEC) that specifies testing and measurement techniques for evaluating the immunity of electrical and electronic equipment to voltage fluctuations. This amendment relates specifically to equipment with an input current not exceeding 16 A per phase, ensuring consistent levels of electromagnetic compatibility (EMC) across products installed in public and industrial electrical networks. The standard harmonizes approaches for manufacturers, laboratories, and regulatory bodies focused on electrical immunity testing.

Key Topics

  • Voltage Fluctuation Immunity: Defines methods to test the resilience of equipment against short-term fluctuations in input voltage, which can occur during typical grid disturbances.
  • Applicability: Covers equipment with input currents up to 16 A per phase, commonly found in domestic, commercial, and light industrial applications.
  • Test Parameters: Outlines repeatable test sequences with clearly defined periods and voltage step changes, helping manufacturers ensure compliance.
  • Performance Verification: Details requirements for verifying testing equipment – including output voltage accuracy, current capability, voltage transition times, and phase accuracy.
  • Compliance and Consistency: Establishes minimum test levels and procedures, ensuring uniform assessment across the European market and alignment with international standards.

Applications

The EN 61000-4-14 standard is broadly applicable in sectors where equipment must operate reliably amid power quality issues. Typical areas of use include:

  • Product Certification: Ensures that electrical and electronic devices can withstand voltage fluctuations, a critical aspect of EMC compliance for CE marking in the EU.
  • Quality Assurance: Used by manufacturers during design and production to validate the immunity of products such as appliances, IT equipment, lighting, industrial controls, and medical devices.
  • Testing Laboratories: Provides laboratories with standardized test sequences and equipment requirements to produce consistent and repeatable results.
  • Regulatory Compliance: Supports compliance with essential requirements of EMC directives and national regulations, reducing the risk of product recalls or compliance penalties.
  • Grid-Connected Devices: Vital for equipment connected to public supply systems, as fluctuations in grid voltage are a common occurrence.

Related Standards

For a comprehensive approach to EMC, consider the following related standards:

  • IEC 61000-4-11: Electromagnetic compatibility - Testing and measurement techniques - Voltage dips, short interruptions, and voltage variations immunity tests.
  • EN 61000-4-13: EMC - Harmonics and interharmonics including mains signaling at AC power port, low-frequency immunity tests.
  • EN 61000-6-1/2/3/4: EMC generic standards for immunity and emission requirements.
  • IEC 61000-4-2/3/4/5: Other parts of the IEC 61000-4 series address different electromagnetic phenomena (static discharge, radiated/conducted disturbances, surges, etc.).

EN 61000-4-14:1999/A2:2009 is essential for achieving robust EMC performance and legal conformity for equipment sold and operated in Europe and other markets adopting CENELEC and IEC standards. By implementing this standard, organizations help ensure electrical products deliver reliable performance in fluctuating voltage environments, safeguarding user experience and system integrity.

Buy Documents

Amendment

EN 61000-4-14:2001/A2:2009

English language (7 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

EN 61000-4-14:1999/A2:2009 is a amendment published by CLC. Its full title is "Electromagnetic compatibility (EMC) - Part 4-14: Testing and measurement techniques - Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase". This standard covers: Electromagnetic compatibility (EMC) - Part 4-14: Testing and measurement techniques - Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase

Electromagnetic compatibility (EMC) - Part 4-14: Testing and measurement techniques - Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase

EN 61000-4-14:1999/A2:2009 is classified under the following ICS (International Classification for Standards) categories: 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 61000-4-14:1999/A2:2009 has the following relationships with other standards: It is inter standard links to EN 267:2020, EN 1776:2025, EN 1776:2015, EN IEC 60143-4:2024, EN 62811:2015, EN 60947-4-3:2014, EN IEC 61226:2021, EN 61674:2013, EN 62340:2010, EN 61226:2010, EN IEC 61674:2024, EN 61000-1-2:2016, EN 60947-4-2:2012, EN 61000-4-14:1999. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 61000-4-14:1999/A2:2009 is associated with the following European legislation: EU Directives/Regulations: 2004/108/EC, 2004/108/EU, 2014/30/EU; Standardization Mandates: M/490. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 61000-4-14:1999/A2:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2009
Elektromagnetna združljivost (EMC) - 4-14. del: Preskusne in merilne tehnike -
Preskus odpornosti proti napetostnemu kolebanju (IEC 61000-4-14:1999/A2:2009)
Electromagnetic compatibility (EMC) -- Part 4-14: Testing and measurement techniques -
Voltage fluctuation immunity test
Elektromagnetische Verträglichkeit (EMV) -- Teil 4-14: Prüf- und Meßverfahren - Prüfung
der Störfestigkeit gegen Spannungsschwankungen
Compatibilité électromagnétique (CEM) -- Partie 4-14: Techniques d'essai et de mesure -
Essai d'immunité aux fluctuations de tension
Ta slovenski standard je istoveten z: EN 61000-4-14:1999/A2:2009
ICS:
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN 61000-4-14/A2
NORME EUROPÉENNE
August 2009
EUROPÄISCHE NORM
ICS 33.100.20
English version
Electromagnetic compatibility (EMC) -
Part 4-14: Testing and measurement techniques -
Voltage fluctuation immunity test for equipment
with input current not exceeding 16 A per phase
(IEC 61000-4-14:1999/A2:2009)
Compatibilité électromagnétique (CEM) - Elektromagnetische
Partie 4-14: Techniques d'essai Verträglichkeit (EMV) -
et de mesure - Teil 4-14: Prüf- und Messverfahren -
Essai d'immunité aux fluctuations Prüfung der Störfestigkeit
de tension pour le matériel von Geräten und Einrichtungen
dont le courant d'entrée mit einem Eingangsstrom
est inférieur ou égal à 16 A par phase bis einschließlich 16 A je Leiter
(CEI 61000-4-14:1999/A2:2009) gegen Spannungsschwankungen
(IEC 61000-4-14:1999/A2:2009)
This amendment A2 modifies the European Standard EN 61000-4-14:1999; it was approved by CENELEC on
2009-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: Avenue Marnix 17, B - 1000 Brussels

© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61000-4-14:1999/A2:2009 E

Foreword
The text of document 77A/669/CDV, future amendment 2 to IEC 61000-4-14:1999, prepared by SC 77A,
Low frequency phenomena, of IEC TC 77, Electromagnetic compatibility, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as amendment A2 to EN 61000-4-14:1999
on 2009-07-01.
The following dates were fixed:
– latest date by which the amendment has to be
implemented at national level by publication of
(dop) 2010-04-01
an identical national standard or by endorsement
– latest date by which the national standards conflicting
(dow) 2012-07-01
with the amendment have to be withdrawn
__________
Endorsement notice
The text of amendment 2:2009 to the International Standard IEC 61000-4-14:1999 was approved by
CENELEC as an amendment to the European Standard without any modification.
__________
IEC 61000-4-14 ®
Edition 1.0 2009-05
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
BASIC EMC PUBLICATION
PUBLICATION FONDAMENTALE EN CEM
AMENDMENT 2
AMENDEMENT 2
Electromagnetic compatibility (EMC) –
Part 4-14: Testing and measurement techniques – Voltage fluctuation immunity
test for equipment with input current not exceeding 16 A per phase

Compatibilité électromagnétique (CEM) –
Partie 4-14: Techniques d'essai et de mesure – Essai d’immunité aux
fluctuations de tension pour le matériel dont le courant d’entrée est inférieur ou
égal à 16 A par phase
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
E
CODE PRIX
ICS 33.100.20 ISBN 2-8318-1041-4
– 2 – 61000-4-14 Amend. 2 © IEC:2009
FOREWORD
This amendment has been prepared by subcommittee 77A: Low frequency phenomena, of
IEC technical committee 77: Electromagnetic compatibility.
The text of this amendment is based on the following documents:
Enquiry draft Report on voting
77A/669/CDV 77A/685/RVC
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...