Tungsten halogen lamps (non-vehicle) - Performance specifications

This International Standard specifies the performance requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: · Projection (including cinematograph and still projection) · · Photographic (including studio) · · Floodlighting · · Special purpose · · General purpose · · Stage lighting This third edition cancels and replaces the second edition published in 1982 and amendments 1(1984), 2(1985), 3(1987), 4(1989), 5(1992), 6(1993), 7(1994), 8(1995), 9(1996), 10(1996), 11(1997), 12(1999) and 13(2000

Halogen-Glühlampen (Fahrzeuglampen ausgenommen) - Anforderungen an die Arbeitsweise

Lampes tungstène-halogène (véhicules exceptés) - Prescriptions de performances

La présente Norme Internationale fournit les prescriptions de performances relatives aux lampes tungstène-halogène à culot unique et à celles à deux culots, ayant des tensions assignées jusqu'à 250 V, utilisées pour les applications suivantes : · Projection (y compris cinéma et projection statique) · · Photographie (y compris prises de vues) · · Illumination · · Usage spécial · · Usage général · · Éclairage de scène La présente troisième édition annule et remplace la seconde édition publiée en 1982 et les amendements 1(1984), 2(1985), 3(1987), 4(1989), 5(1992), 6(1993), 7(1994), 8(1995), 9(1996), 10(1996), 11(1997), 12(1999) et 13(2000).

Volframove halogenske sijalke (ne za vozila) - Tehnične specifikacije - Dopolnilo A11

General Information

Status
Published
Publication Date
09-Jun-2016
Withdrawal Date
13-Mar-2019
Current Stage
6060 - Document made available - Publishing
Start Date
10-Jun-2016
Due Date
18-Jan-2018
Completion Date
10-Jun-2016

Relations

Buy Standard

Amendment
EN 60357:2004/A11:2016
English language
14 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2016
9ROIUDPRYHKDORJHQVNHVLMDONH QH]DYR]LOD 7HKQLþQHVSHFLILNDFLMH'RSROQLOR
$
Tungsten halogen lamps (non-vehicle) - Performance specifications
Halogen-Glühlampen (Fahrzeuglampen ausgenommen) - Anforderungen an die
Arbeitsweise
Lampes tungstène-halogène (véhicules exceptés) - Prescriptions de performances
Ta slovenski standard je istoveten z: EN 60357:2003/A11:2016
ICS:
29.140.20 Žarnice z žarilno nitko Incandescent lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 60357:2003/A11

NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2016
ICS 29.140.20
English Version
Tungsten halogen lamps (non-vehicle) - Performance
specifications
Lampes tungstène-halogène (véhicules exceptés) - Halogen-Glühlampen (Fahrzeuglampen ausgenommen) -
Prescriptions de performances Anforderungen an die Arbeitsweise
This amendment A11 modifies the European Standard EN 60357:2003; it was approved by CENELEC on 2016-03-14. CENELEC members
are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the status of a
national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60357:2003/A11:2016 E

European foreword
This document (EN 60357:2003/A11:2016) has been prepared by CLC/TC 34A "Lamps".

The following dates are fixed:
– latest date by which this document has to be implemented at (dop) 2017-03-14
national level by publication of an identical
national standard or by endorsement
– latest date by which the national standards conflicting with this (dow) 2019-03-14
document have to be withdrawn
Clauses, subclauses, notes, tables, figures and annexes which are additional to those in
IEC 60357:2002 and its amendments are prefixed “Z”.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
This standard provides test methods related to parameters as prescribed by Commission Regulation
(EC) 244/2009, Commission Regulation (EU) 1194/2012 and Commission Regulation (EU) 874/2012
while conformity assessment (sampling, conformity procedures as well as limits) for market
surveillance are specified in the text of the above Regulations.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association, and supports essential requirements of EU Directive(s).

For the relationship with EU Directive(s) see informative Annex ZZA, ZZB and ZZC, which are integral
parts of this document.
CONTENTS Add the following annexes:
Annex ZA (normative) Normative references to international publications with their
corresponding European publications
Annex ZZA (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EC) No 244/2009
Annex ZZB (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EU) No 1194/2012
Annex ZZC (informative) Relationship between this European Standard and the
requirements of Commission Delegates Regulation (EU)
N° 874/2012
Delete all references to lamp caps E11.
Delete the following lamp data sheets from the IEC text:
60357-IEC-3211-3
60357-IEC-3230-2
60357-IEC-6115-1
60357-IEC-6720-1
60357-IEC-6722-1
60357-IEC-6725-1 and 2
60357-IEC-6726
60357-IEC-6727
60357-IEC-6820-1
Delete the following particular lamp types from lamp data sheets in the IEC text:
Lamp types deleted
Lamp data sheet
Rated wattage Voltage range Z
nom
60357-IEC-3005-3 1 000 B 89,6
1 000 B 104,1
750 B 114,2
1 000 B 138,1
1 000 B 162,0
1 500 B 162,0
60357-IEC-3105-2 650 B 74,9
800 C 74,9
1 250 C 121,7
60357-IEC-3210-3 750 B –
60357-IEC-4105-4 2 000 – 327,4
60357-IEC-4105-5 2 000 – 327,4

1.0.Z1 Add the following clause before clause 1.1
1.0.Z1 Overall statement
Where a Commission Regulation specifies limits for parameters these limits shall be
used instead of the limits specified in this standard.
1.3.Z1 After 1.3.18 add new definitions 1.3.Z1 up to 1.3.Z3:
3.Z1
directional lamp
lamp having at least 80 % light output within a solid angle of π sr (corresponding to a
cone with angle of 120°)
[SOURCE: Regulation 1194/2012 Article 2]
3.Z2
partial luminous flux (of a light source, within a specified cone angle)
luminous flux emitted from a light source within a specified cone angle α, determined
from the luminous intensity distribution I(θ, ϕ) of the source:
2π α /2
Φ = I(θ,ϕ) sinθ dθ dϕ
α
∫∫
ϕθ00
(2)
Note 1 to entry:  Partial luminous flux is expressed in lumen (lm)
Note 2 to entry:   (θ, ϕ)=(0,0) is the direction of the cone axis
Note 3 to entry:  The cone angle α is the full angle (diameter) of the cone
[SOURCE: EN 13032-4:2015, 3.41, modified, – Notes 4 and 5 removed]
3.Z3
useful luminous flux, Φ
use
partial luminous flux of a halogen lamp falling within the cone used for calculating the
halogen lamp’s energy efficiency according Annex III, point 1.1 of COMMISSION
REGULATION (EU) No 1194/2012
Note 1 to entry:  Useful luminous flux is expressed in lumen (lm)
Note 2 to entry: The regulation specifies 90° or 120° cones according to the product characteristics
Note 3 to entry: Useful luminous flux is similar to partial luminous flux. It is determined with the cone axis
coincident with the observed optical beam axis of the light source, the axis about which
the luminous intensity is substantially symmetrical
1.4.3 Replace the entire clause 1.4.3 by:
1.4.3 Dimensions
1.4.3.Z1 General
Lamps and, if applicable, filament dimensions shall comply with the values specified
on the relevant lamp data sheet.
Measurement of the lamp dimensions shall be done with a caliper at 20 ºC to 30 ºC.
==
1.4.3.Z2 Relationship between some types and Table 6 of COMMISSION
REGULATION (EU) No 1194/2012
The following types, as listed in Table 6 of COMMISSION REGULATION (EU)
No 1194/2012, are considered to be related to data sheet as given in the following
Table Z1.
Table Z1 - Relationship between some types and Table 6 of COMMISSION
REGULATION (EU) No 1194/2012
Type Data sheet covering Designation covered by the sheet
the type
(as in Table 6 of 1194/2012)
Mains-voltage blown glass reflector types
R50/NR50 1 R50 E14
60630-IEC-1510-
R63/NR63 60630-IEC-1520- R63 E27
60630-IEC-1530- R63 B22d
R80/NR80 60630-IEC-1540- R80 E27
60630-IEC-1550- R80 B22d
R95/NR95 60630-IEC-1570- R95 E27
60630-IEC-1580- R95 B22d
R125 60630-IEC-1590- R125 E27
60630-IEC-1600- R125 B22d
Mains-voltage pressed glass reflector types
PAR16 60357-IEC-1015- PAR16 GU10
(also called PAR50 GU10)
PAR16 60630-IEC-1510- PAR50 E14
(also called PAR16)
PAR20 60357-IEC-1016- PAR20 GU10
(also called PAR63 GU10)
PAR20 60630-IEC-1520- PAR63 E27
(also called PAR20)
PAR25 60630-IEC-1540- PAR80 E27
(also called PAR25)
PAR30S 60630-IEC-1610- PAR95S E27
(also called PAR30S)
PAR38 60630-IEC-1620- PAR121 E27
(also called PAR38)
Extra-low voltage reflector type
MR11 GU4 60357-IEC-6310- MR11
MR11 GU4 60357-IEC-6315- MR11
MR16 GU 5.3 60357-IEC-6320- MR16
MR16 GU 5.3 60357-IEC-6325- MR16
AR111 60357-IEC-6450- AR111
1.4.5.1 Add in indent a) the following after the wording ‘tungsten halogen lamp:
———————
These data sheets refer to lamp maximum outline dimensions in EN 60630. These lamps are not otherwise specified in this
standard.
(or useful luminous flux for directional lamps) (lm)
1.4.Z1 After 1.4.7 add new clauses 1.4.Z1 up to 1.4.Z7:
1.4.Z1
The measurement of the spectral power distribution shall be made under the
conditions of Annex A and in accordance with CIE 63.
1.4.Z2
The Correlated colour temperature (CCT) shall be calculated in accordance with
CIE 015:2004.
1.4.Z3
The test for starting and warm-up times shall be in accordance with EN 60969:201x ,
B.3.
Starting time is determined as the period from the start of the test to when the lamp
has fully completed the starting sequence (lamp has started and remains alight).
Warm-up time is the time taken from the start of the test to when the lamp achieves
the required percentage of its stable luminous flux.
Halogen lamps without integrated controlgear are deemed to fulfil the starting time
requirement by their technology. Testing is not needed.
1.4.Z4
The Colour rendering index (CRI) of an individual lamp shall be calculated from the
spectral power distribution in accordance with CIE 13.3:1995.
1.4.Z5
The determination of the power factor shall be in accordance with IEC/TR 61000-1-
7:2016.
Halogen lamps without integrated controlgear are deemed to fulfil the power factor
requirement by their technology. Testing is not needed.
1.4.Z6
Lamps without integrated control gear are deemed to be dimmable without testing.
Testing of other types is under consideration.
1.4.Z7
For switching requirements the test conditions shall be as specified in A.3.1. The
switching cycle used shall be 1 min on and 3 min off.
———————
In preparation
Annex A.2 Replace the entire subclause by:
A.2.1 General
Luminous flux shall be measured in accordance with CIE 84:1984.
Beam angle(s) and centre beam intensity shall be measured in accordance with
EN 61341:2011.
Prior to the initial measurements the lamp shall be aged for approximately 1 h at its
rated voltage.
Tests shall be made in a draught-free atmosphere.
Photometric characteristics shall be measured in accordance with EN 13032-1:2004.
A.2.2 Useful luminous flux
For directional lamps the useful luminous flux is obtained by luminous intensity
integration as described in EN 13032-4:2015, 6.3 “Partial luminous flux “.
Alternative measurement methods may be used if they can be shown to give
equivalent results for the product being tested, if necessary by applying correction
factors. Measurements with lamps operating horizontally are often much easier to
carry out. The reference method, however, uses the following measurement position:
lamps shall be operated in free air in a vertical base-up position.
In case of doubt a goniophotometry measurement in accordance with
EN 13032-4:2015, 6.3 shall be leading.
NOTE Below are a few examples of alternative measurement methods. It is not an exhaustive list.
• For small beam angles shine into integrating sphere.
• Mount lamp on internal surface of integrating sphere.
• Mount lamp inside integrating sphere with screening (LM-20 technique).
• Illuminate a surface and measure the illuminance across the surface with a photometer.
• Illuminate a surface and measure the surface luminance with a luminance camera.
• Illuminate a translucent screen and measure the surface luminance of the rear side with a
luminance camera.
Annex A.3.7 Add the following requirement to the end of this subclause:
Lamps that fail prior to 75% of rated life shall not be included in the average for lumen
maintenance.
Bibliography Add the following notes for the standards indicated:
IEC 60127-2 NOTE Harmonized as EN 60127-2
IEC 60335-2-56 NOTE Harmonized as EN 60335-2-56
IEC 60598-2 NOTE Harmonized as EN 60598-2-x series
IEC 60682 NOTE Harmonized as EN 60682
IEC 61231 NOTE Harmonized as EN 61231
Add the following documents:
COMMISSION REGULATION (EC) No 244/2009 of 18 March 2009 implementing
Directive 2009/125/EC of the European Parliament and of the Council with regard to
ecodesign requirements for non-directional household lamps
COMMISSION DELEGATED REGULATION (EU) No 874/2012 of 12 July 2012
supplementing Directive 2010/30/EU of the European Parliament and of the Council
with regard to energy labelling of electrical lamps and luminaires
COMMISSION REGULATION (EU) No 1194/2012 of 12 December 2012
implementing Directive 2009/125/EC of the European Parliament and of the Council
with regard to ecodesign requirements for directional lamps, light emitting diode lamps
and related equipment
- - - - -
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest e
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.