prEN IEC 63044-3:2026
(Main)Home and building electronic systems (HBES) and building automation and control systems (BACS) - Part 3: Electrical safety requirements
- Status
- Not Published
- Publication Date
- 07-Nov-2027
- Technical Committee
- CLC/TC 205 - Home and Building Electronic Systems (HBES)
- Current Stage
- 4060 - Enquiry results established and sent to TC, SR, BTTF - Enquiry
- Start Date
- 21-Aug-2026
- Due Date
- 21-Aug-2026
- Completion Date
- 21-Aug-2026
prEN IEC 63044-3:2026 is the CLC draft for Home and building electronic systems (HBES) and building automation and control systems (BACS) - Part 3: Electrical safety requirements. It specifies the electrical safety requirements for HBES/BACS networks and the equipment interfaces connected to them so that they remain safe under normal use and single-fault conditions. The document is meant for product committees, manufacturers, system designers and installers who need the network-side safety rules for HBES/BACS equipment.
What does prEN IEC 63044-3:2026 specify?
prEN IEC 63044-3:2026 specifies the electrical safety requirements for an HBES/BACS network and for equipment interfaces connected to that network. It focuses on network-side safety, not on the electrical safety of the device itself except at the interface to the HBES/BACS network.
The scope covers protection against hazards from the device, overvoltages on the network, touch current, hazards caused by different types of network, and overheating of the communication wiring. It applies under normal and single-fault conditions. It does not apply to interfaces to other networks, and it does not cover functional safety.
The document is organized into:
- Clause 1 Scope
- Clause 2 Normative references
- Clause 3 Terms, definitions and abbreviated terms
- Clause 4 Safety requirements and compliance criteria
- Clause 5 Requirements
- Annex A, which is informative and lists product standards for electrical safety
- Bibliography
What are the key requirements of prEN IEC 63044-3:2026?
prEN IEC 63044-3:2026 combines network classification, insulation coordination, touch-current limits and installation rules. In practice, it tells a product designer what kind of separation, voltage withstand and documentation are needed for a device port to be acceptable on an HBES/BACS network.
Classification of installation areas
Clause 5.2 classifies HBES/BACS devices by installation conditions. Devices installed as part of the fixed installation shall be treated as overvoltage category III, while devices supplied from the fixed installation but not part of it shall be at least category II. All devices shall be at least pollution degree 2 and material group IIIa. For a manufacturer, this means the enclosure, insulation and spacing choices must match a building-installation environment, not a benign indoor electronics environment.
Device safety and product standards
Clause 5.3.1 requires the device to meet the relevant product safety standard, taking the overvoltage category and pollution degree into account. Annex A gives a non-exhaustive list of product standards used with HBES/BACS equipment such as controllers, actuators, UPS, luminaires, electronic control devices and power supplies. In practice, IEC 63044-3 is used together with the product standard, not instead of it.
Network type and electrical separation
Clause 5.3.2 separates two cases. For devices connected to an ICT network, IEC 62949 applies in addition to the product standard. For devices connected to a dedicated HBES/BACS network, Table 1 defines the required electrical separation between the device circuit and the HBES/BACS network circuit. The table uses rated insulation voltage, AC withstand voltage and impulse withstand levels, so designers must choose the separation type that matches the network voltage and circuit classification.
When the separation between mains and SELV is done by a transformer, the transformer shall be a safety transformer to IEC 61558-2-6 or IEC 61558-2-16. The manufacturer’s documentation also has to state the safety classification of the ports and any network-topology restrictions. For a buyer or integrator, that means port labeling and installation instructions are part of the safety case, not optional extras.
Touch current limits
Clause 5.3.3 limits touch current and defines when basic protection is needed for SELV and PELV circuits. If the nominal voltage is above 25 V AC or 60 V DC, or if the equipment is immersed, basic protection is required by insulation, barriers or enclosures. For mains-supplied devices connected to the HBES/BACS network, the touch current to the network shall be limited to 0.25 mA rms and measured using the method referenced in IEC 62151.
Clause 5.3.3.4 adds summation rules for devices with multiple network ports. If a device can pass touch current from several connected items of equipment, the total has to stay within the stated limits, and some earthed-port arrangements require a permanent protective-earth connection and a warning label. In practice, this matters for hubs, gateways and other multiport devices where touch currents can add up across ports.
Protection of communication wiring from overheating
Clause 5.3.4 requires the network power supply to have short-circuit and/or overload current limitation so that the communication wiring cannot overheat. The current-carrying capacity of the communication wires shall be at least equal to the total current limitation of the connected power supplies, and the temperature and current limits in IEC 60364-5-52 shall not be exceeded. For installation teams, this means cable sizing and power limiting have to be coordinated.
Installation rules
Clause 5.4 requires installation to comply with IEC 60364 (all parts) and the manufacturer’s installation instructions, and IEC 63044-6:2021 has to be taken into consideration. This makes the installation rules part of the safety evaluation, not just the device design.
What terms does prEN IEC 63044-3:2026 define?
prEN IEC 63044-3:2026 uses a set of safety terms that are central to its separation and voltage rules.
- ICT network - a metallic two-conductor communication network that can connect equipment in separate buildings, excluding mains, dedicated HBES/BACS networks and certain external networks.
- electric shock - the physiological effect caused when electric current passes through a human or livestock.
- basic protection - protection against electric shock under normal conditions.
- fault protection - protection against electric shock under single-fault conditions.
- ELV - extra low voltage, defined here as voltage within voltage band I in IEC 61140.
- SELV network - a safety extra low voltage network that stays within ELV under normal and single-fault conditions, including earth fault in other networks.
- PELV network - a protective extra low voltage network that stays within ELV under normal and single-fault conditions, except for earth fault in other networks.
Who uses prEN IEC 63044-3:2026?
prEN IEC 63044-3:2026 is used by IEC technical committees that prepare product standards for HBES/BACS equipment, because Clause 4 says it is the minimum network-side safety basis when a product standard already contains safety requirements. It is also used by manufacturers of controllers, actuators, power supplies, UPS, electronic control devices, lighting devices and communication interfaces listed in Annex A.
System designers, installers and integrators use it to decide network classification, insulation separation, touch-current control and installation method. Conformity and test personnel use it when checking overvoltage category, pollution degree, current limits and the required measurements or inspections.
What changed in prEN IEC 63044-3:2026 from the previous edition?
prEN IEC 63044-3:2026 is the second edition and it replaces the first edition published in 2017 and Amendment 1:2021. The document states these significant technical changes:
- updates to the IEC standards referenced in the terms/definitions clause and in the requirements clauses
- deletion of the former Clause 4, which was void
- addition of IEC 63044-6 as a document to be taken into consideration in Clause 5.4
Which standards are used with prEN IEC 63044-3:2026?
| Standard | What it contributes |
|---|---|
| IEC 63044-1 | General requirements and shared terms for the HBES/BACS series |
| IEC 63044-6:2021 | Planning and installation requirements to consider in Clause 5.4 |
| IEC 62949 | Safety requirements for equipment connected to information and communication networks |
| IEC 60364 (all parts) | Low-voltage electrical installation rules used for installation compliance |
| IEC 60364-5-52 | Wiring systems, including temperature limits and current-carrying capacity |
| IEC 60664-1 | Insulation coordination, overvoltage category and pollution degree basis |
| IEC 61180 | High-voltage test techniques used for impulse testing of separations |
| IEC 62151:2000 | Touch-current measurement method for network connections |
| IEC 60038 | Standard voltages used in the voltage definitions |
| IEC 60050-195 and IEC 60050-826 | Vocabulary for electric shock, protection and insulation terms |
| IEC 61558-2-6 and IEC 61558-2-16 | Safety transformers used when mains-to-SELV separation is done by transformer |
What does the prEN IEC 63044-3:2026 document contain?
prEN IEC 63044-3:2026 contains the definitions, classification rules, electrical separation table and test/inspection approach needed to check HBES/BACS network interfaces. Table 1 is the key design table: it relates mains, ELV, FELV, SELV and PELV network conditions to the required type of separation and the associated withstand levels. The document also contains measurement-based compliance checks for touch current, inspection-based checks for classification and documentation, and installation guidance that ties the network rules to IEC 60364 and the manufacturer’s instructions.
Annex A gives a practical map from HBES/BACS equipment types to the product standards commonly used for electrical safety. That helps standards writers and engineers see which device standard sits alongside this part when they design or assess a product.
Relations
- Effective Date
- 22-Jul-2025
- Effective Date
- 22-Jul-2025
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
prEN IEC 63044-3:2026 is a draft published by CLC. Its full title is "Home and building electronic systems (HBES) and building automation and control systems (BACS) - Part 3: Electrical safety requirements". This standard covers: Home and building electronic systems (HBES) and building automation and control systems (BACS) - Part 3: Electrical safety requirements
Home and building electronic systems (HBES) and building automation and control systems (BACS) - Part 3: Electrical safety requirements
prEN IEC 63044-3:2026 is classified under the following ICS (International Classification for Standards) categories: 29.120.01 - Electrical accessories in general; 29.120.99 - Other electrical accessories. The ICS classification helps identify the subject area and facilitates finding related standards.
prEN IEC 63044-3:2026 has the following relationships with other standards: It is inter standard links to EN IEC 63044-3:2018/A1:2025, EN IEC 63044-3:2018. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
prEN IEC 63044-3:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/35/EU; Standardization Mandates: M/511. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
prEN IEC 63044-3:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and abbreviated terms
- 3.1 Terms and definitions
- 3.1.1 ICT network
- 3.1.2 electric shock
- 3.1.3 basic protection
- 3.1.4 fault protection
- 3.1.5 mains
- 3.1.6 mains network
- 3.1.7 extra low voltage
- 3.1.8 extra low voltage network
- 3.1.9 functional extra low voltage network
- 3.1.10 safety extra low voltage network
- 3.1.11 protective extra low voltage network
- 3.1.12 simple separation
- 3.1.13 protective separation
- 3.1.14 basic insulation
- 3.1.15 double insulation
- 3.1.16 supplementary insulation
- 3.1.17 electrically protective screening
- 3.1.18 reinforced insulation
- 3.2 Abbreviated terms
- 4 Safety requirements and compliance criteria
- 5 Requirements
- 5.1 General
- 5.2 Classification requirements of installation areas
- 5.3 Electrical safety requirements
- 5.4 Installation
- Annex A
- Bibliography
INTRODUCTION The IEC 63044 series deals with developing and testing Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS).
This document deals with electrical safety requirements for HBES/BACS. This document is based on the philosophy that a device considered electrically safe according to an appropriate product safety standard should also remain safe when connected to a network. This document specifies in addition to the specific product standar d the electrical safety requirements necessary in order for an HBES/BACS device connected to a network to remain safe under normal and single-fault conditions of the HBES/BACS network and at the same time under normal and single-fault conditions of one or more HBES/BACS devices connected to the HBES/BACS network. This includes protection from overvoltages on the network, protection from hazards caused by connection of different types of network, the limitation of the touch current to a network and protection of the communication wiring from overheating. The HBES/BACS network is any interconnection between HBES/BACS devices. The HBES/BACS networks can be either an ICT network with interfaces classified according to IEC 62949 or a dedicated network classified as a mains, ELV, FELV, SELV or PELV networks. For HBES/BACS devices connected to an ICT network, the requirements in IEC 62949 apply. For HBES/BACS devices connected to a dedicated HBES/BACS network, the requirements for the electrical separation between the device and the network are specified (see Table 1). These specifications of the electrical separations follow the principle in the basic safety publications IEC 60664-1:2020 and IEC 61140 [1], together with the installation requirements of IEC 60364 (all parts). The following compromises are used.
- According to the principles of IEC 60664-1, the rated impulse voltage for the separation shall be the higher of the impulse voltage on the network and the rated impulse voltage of the device circuit to be connected to the network.
- The overvoltage categories considered by IEC 60664-1 refer to overvoltages derived directly from the mains through the power supply.
- The overvoltages coming from other sources (e.g. capacitive couplings) are not specified in IEC 60664-1. IEC 60664-1 recommends that technical committees specify overvoltage categories or rated impulse voltages as appropriate.
For the purposes of this document, the following impulse voltages have been specified. - For networks with galvanic electrical separation from mains (FELV, SELV or PELV), the impulse overvoltage coming from the network side of the separation has been limited to 2,5 kV for fixed installed networks and 1,5 kV for detachable networks. - For ICT networks, particular requirements apply (see 5.3.2.1).
oSIST prEN IEC 63044-3:2026
1 Scope
The IEC 63044 series deals with developing and testing Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS).
This group safety publication is primarily intended to specify the electrical safety requirements for an HBES/BACS network and for the equipment interfaces to an HBES/BACS network under normal and single-fault conditions, unless equivalent or higher requirements are included in the product standard.
It does not apply to interfaces to other networks.
NOTE An example of other networks is a dedicated ICT network covered by IEC 62949. This document does not cover the electrical safety requirements for the devices connected to the HBES/BACS, that are covered by the applicable product standard, except for the equipment interfaces to an HBES/BACS network.
This document covers the following requirements and compliance criteria:
- protection against hazards from the device;
- protection against overvoltages on the network;
- protection against touch current;
- protection against hazards caused by different types of network;
- protection of the communication wiring against overheating caused by excessive current. This document is also intended to be used by technical committees in the preparation of product standards for the safety requirements of the equipment interfaces to be connected to an HBES/BACS network, in accordance with the principles laid down in IEC Guide 104.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60038:2009, IEC standard voltages IEC 60050-195:2021, International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock IEC 60050-826:2022, International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations IEC 60364 (all parts), Low-voltage electrical installations IEC 60364-5-52, Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems IEC 60664-1, Insulation coordination for equipment within low-voltage supply systems - Part 1:
Principles, requirements and tests
oSIST prEN IEC 63044-3:2026
IEC 60664-1:2020, Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests IEC 61180, High-voltage test techniques for low-voltage equipment - Definitions, test and procedure requirements, test equipment IEC 62151:2000, Safety of equipment electrically connected to a telecommunication network IEC 62949, Particular safety requirements for equipment to be connected to information and communication networks IEC 63044-1, Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 1: General requirements IEC 63044-6:2021, Home and building electronic systems (HBES) and building automation and control systems (BACS) - Part 6: Requirements for planning and installation
3 Terms, definitions and abbreviated terms
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 63044-1 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- IEC Electropedia: available at https://www.electropedia.org/
- ISO Online browsing platform: available at https://www.iso.org/obp
3.1.1 ICT network
information and communication technology network metallically terminated transmission medium consisting of two conductors intended for communication between equipment that may be located in separate buildings, excluding:
- the mains system for supply, transmission and distribution of electrical power, if used as a communication transmission medium;
- dedicated HBES/BACS networks;
- external networks using ES1 connecting units of audio/video, information and communication technology equipment.
Note 1 to entry: This may include twisted pairs, and may include networks which are subjected to transients as indicated in Table 14, ID1 of IEC 62368-1 [2]:2014 (assumed to be 1,5 kV). Note 2 to entry: An ICT network may be:
- publicly or privately owned;
- subject to transient overvoltages due to atmospheric discharges and faults in power distribution systems;
- subject to longitudinal (common mode) voltages induced from nearby power lines or electric traction lines. Note 3 to entry: Examples of ICT networks are:
- a public switched telephone network;
- a public data network;
- an Integrated Services Digital Network (ISDN);
- a private network with electrical interface characteristics similar to the above.
oSIST prEN IEC 63044-3:2026
3.1.2 electric shock
physiological effect resulting from an electric current passing through a human or livestock [SOURCE: IEC 60050-195:2021 , 195-01-04]
3.1.3 basic protection
protection against electric shock under normal conditions [SOURCE: IEC 60050-195:2021, 195-06-01]
3.1.4 fault protection
protection against electric shock under single-fault conditions [SOURCE: IEC 60050-195:2021 195-06-02]
3.1.5 mains
power supply system with nominal voltage according IEC 60038:2009, Table 1
3.1.6 mains network
electrical network in which the nominal voltage cannot exceed mains voltage under normal conditions
3.1.7 extra low voltage
ELV nominal voltage in the electrical installation of buildings according to the voltage band I specified in IEC 61140 [1] Note 1 to entry: Voltage band I according to IEC 61140 [1] is a voltage below or equal to 50 V AC or 120 V DC.
3.1.8 extra low voltage network
ELV network electrical network in which the nominal voltage cannot exceed ELV (3.1.7) under normal conditions Note 1 to entry: An ELV network is not safe to touch.
3.1.9 functional extra low voltage network
FELV network electrical network in which the nominal voltage cannot exceed ELV (3.1.7) under normal conditions Note 1 to entry: FELV has simple separation from mains.
Note 2 to entry: A FELV network is not safe to touch and may be connected to protective earth.
3.1.10 safety extra low voltage network
SELV network electrical network in which the nominal voltage cannot exceed ELV (3.1.7)
oSIST prEN IEC 63044-3:2026
- under normal conditions,
- under single-fault conditions, including earth fault in other networks Note 1 to entry: SELV has simple separation from PELV and other SELV systems, and earth and protective separation from all other networks.
Note 2 to entry: Under normal conditions and single-fault conditions in a dry location inside a building, a SELV network with a voltage not higher than 25 V AC or 60 V DC is safe to touch.
3.1.11 protective extra low voltage network
PELV network electrical network in which the nominal voltage cannot exceed ELV (3.1.7) - under normal conditions, - under single-fault conditions, except earth fault in other networks Note 1 to entry: PELV has protective separation from all networks other than PELV, SELV or earth. Note 2 to entry: PELV network is safe to touch within the same equipotential bonding area inside a building under the following conditions: under normal and single-fault conditions in dry locations and with a voltage not higher than 25 V AC or 60 V DC; otherwise not higher than 12 V AC or 30 V DC.
3.1.12 simple separation
separation between networks or between a network and earth by means of basic insulation
...