EN 12350-8:2019
(Main)Testing fresh concrete - Part 8: Self-compacting concrete - Slump-flow test
Testing fresh concrete - Part 8: Self-compacting concrete - Slump-flow test
This document specifies the procedure for determining the slump-flow and t500 time for self-compacting concrete.
The test is suitable for specimens having a declared value of D of the coarsest fraction of aggregates actually used in the concrete (Dmax) not greater than 40 mm.
Prüfung von Frischbeton - Teil 8: Selbstverdichtender Beton - Setzfließversuch
Dieses Dokument legt das Verfahren zur Bestimmung des Setzfließmaßes und der Zeit t500 für selbstverdich¬tenden Beton fest.
Die Prüfung ist für Proben geeignet, deren Nennwert D des gröbsten der im Beton verwendeten Gesteinskörnungen (Dmax) nicht größer als 40 mm ist.
Essais pour béton frais - Partie 8 : Béton auto-plaçant - Essai d’étalement au cône
Le présent document spécifie le mode opératoire de détermination de l’essai d’étalement au cône et du temps t500 pour le béton auto-plaçant.
L’essai est adapté aux échantillons ayant une valeur déclarée de D pour les plus gros granulats effectivement utilisés dans le béton (Dmax) inférieure ou égale à 40 mm.
Preskušanje svežega betona - 8. del: Samozgoščevalni beton - Preskus razleza s posedom
Ta evropski standard določa postopek za določanje razleza s posedom in čas t500 za samozgoščevalni beton.
Preskus je primeren za primerke, pri katerih je deklarirana vrednost D najbolj grobega agregata, ki je dejansko uporabljen v betonu (Dmax), manjša od 40 mm.
General Information
- Status
- Published
- Publication Date
- 18-Jun-2019
- Withdrawal Date
- 30-Dec-2019
- Technical Committee
- CEN/TC 104 - Concrete ( performance, production, placing and compliance criteria )
- Drafting Committee
- CEN/TC 104/SC 1 - Revision of ENV 206
- Current Stage
- 9093 - Decision to confirm - Review Enquiry
- Start Date
- 24-Jun-2025
- Completion Date
- 23-Sep-2025
Relations
- Replaces
EN 12350-8:2010 - Testing fresh concrete - Part 8: Self-compacting concrete - Slump-flow test - Effective Date
- 26-Jun-2019
Overview
EN 12350-8:2019 is a European standard developed by CEN that specifies the testing procedure for assessing the flowability of fresh self-compacting concrete (SCC) using the slump-flow test. The standard focuses on measuring two key parameters: the slump-flow diameter and the t500 time, which reflects the speed at which concrete spreads to a 500 mm diameter after lifting a slump cone. The test is applicable to concrete mixes with coarse aggregates having a maximum size (Dmax) of up to 40 mm.
This test method is essential for evaluating the fresh properties of SCC to ensure it achieves the desired filling ability, homogeneity, and self-compaction without vibration. It supports quality control on-site, especially during the use of new concrete compositions or constituents.
Key Topics
Scope and Applicability
- Testing fresh self-compacting concrete for slump-flow and t500 time
- Suitable for mixes with Dmax ≤ 40 mm
Test Principle
- Concrete is poured into a hollow cone as per EN 12350-2 (slump test)
- Cone is lifted vertically in 1–3 seconds, allowing concrete to flow freely
- Time taken for concrete flow to reach 500 mm diameter (t500 time) is recorded
- Maximum and perpendicular diameters of the spread are measured to calculate slump-flow
Test Apparatus
- Hollow cone, baseplate with marked circles at 210 mm and 500 mm diameters
- Measuring tape, timer, spirit level, remixing container, and optional weighted collar
- Baseplate must be flat, smooth steel or equivalent material for reliable results
Test Procedure
- Ensure horizontal placement of baseplate and dampen cone before filling
- Fill cone in one lift without mechanical compaction; strike off excess
- Remove cone and start timing the flow to the 500 mm mark
- Measure diameters after flow stabilizes, evaluate for segregation
Reporting Results
- Slump-flow (mean diameter) to nearest 10 mm
- t500 time to nearest 0.5 seconds (if measured)
- Qualitative assessment of segregation
- Include test conditions, concrete identification, and any deviations from the standard
Accuracy and Repeatability
- Repeatability and reproducibility values provided based on multi-laboratory studies
- Ensures reliability and consistency in test outcomes across different operators and labs
Applications
Quality Control in Concrete Production
EN 12350-8:2019 provides an efficient and standardized method for concrete producers and site engineers to assess fresh SCC properties, ensuring the concrete mix meets the required flowability for self-compacting behavior.Pre-Construction Testing
Lab testing of new SCC formulations for flow properties before large-scale pouring helps to verify consistency, preventing defects related to poor filling or aggregate segregation.On-Site Verification
The slump-flow test is a practical tool for routine testing on construction sites to monitor SCC workability during placement, especially in complex molds or highly reinforced structures where vibration is impractical.Research and Development
The standard serves as a baseline method for evaluating innovative SCC mixes and admixtures affecting flowability and viscosity.
Related Standards
- EN 12350-1:2019 – Testing fresh concrete - Sampling and common apparatus
- EN 12350-2:2019 – Testing fresh concrete - Slump test
- EN 12350-9:2019 – Self-compacting concrete - V-funnel test
- EN 12350-10:2019 – Self-compacting concrete - L-box test
- EN 12350-11:2019 – Self-compacting concrete - Sieve segregation test
- EN 12350-12:2019 – Self-compacting concrete - J-ring test
These complementary standards provide a comprehensive framework for testing various properties of fresh concrete and self-compacting concrete, covering filling ability, passing ability, segregation resistance, and consistency.
Keywords: EN 12350-8:2019, self-compacting concrete, slump-flow test, fresh concrete testing, slump-flow diameter, t500 time, concrete flowability, concrete workability, SCC testing, concrete quality control, European standard, CEN concrete standards.
Frequently Asked Questions
EN 12350-8:2019 is a standard published by the European Committee for Standardization (CEN). Its full title is "Testing fresh concrete - Part 8: Self-compacting concrete - Slump-flow test". This standard covers: This document specifies the procedure for determining the slump-flow and t500 time for self-compacting concrete. The test is suitable for specimens having a declared value of D of the coarsest fraction of aggregates actually used in the concrete (Dmax) not greater than 40 mm.
This document specifies the procedure for determining the slump-flow and t500 time for self-compacting concrete. The test is suitable for specimens having a declared value of D of the coarsest fraction of aggregates actually used in the concrete (Dmax) not greater than 40 mm.
EN 12350-8:2019 is classified under the following ICS (International Classification for Standards) categories: 91.100.30 - Concrete and concrete products. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 12350-8:2019 has the following relationships with other standards: It is inter standard links to EN 12350-8:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 12350-8:2019 is associated with the following European legislation: EU Directives/Regulations: 305/2011; Standardization Mandates: M/128. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
You can purchase EN 12350-8:2019 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2019
Preskušanje svežega betona - 8. del: Samozgoščevalni beton - Preskus razleza s
posedom
Testing fresh concrete - Part 8: Self-compacting concrete - Slump-flow test
Prüfung von Frischbeton - Teil 8: Selbstverdichtender Beton - Setzfließversuch
Essai pour béton frais - Partie 8 : Béton auto-plaçant - Essai d'étalement au cône
Ta slovenski standard je istoveten z: EN 12350-8:2019
ICS:
91.100.30 Beton in betonski izdelki Concrete and concrete
products
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 12350-8
EUROPEAN STANDARD
NORME EUROPÉENNE
June 2019
EUROPÄISCHE NORM
ICS 91.100.30 Supersedes EN 12350-8:2010
English Version
Testing fresh concrete - Part 8: Self-compacting concrete -
Slump-flow test
Essais pour béton frais - Partie 8 : Béton auto-plaçant - Prüfung von Frischbeton - Teil 8: Selbstverdichtender
Essai d'étalement au cône Beton - Setzfließversuch
This European Standard was approved by CEN on 29 April 2019.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 12350-8:2019 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Principle . 5
5 Apparatus . 5
6 Test sample . 7
7 Procedure. 7
8 Test result . 8
9 Test report . 8
10 Repeatability and reproducibility . 9
Bibliography . 10
European foreword
This document (EN 12350-8:2019) has been prepared by Technical Committee CEN/TC 104 “Concrete
and related products”, the secretariat of which is held by SN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by December 2019, and conflicting national standards
shall be withdrawn at the latest by December 2019.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 12350-8:2010.
This standard is based on the results from the EU-project “Testing-SCC” under the 5th Frame
Programme (GRD2-2000-30024/G6RD-CT-2001-00580).
Owing to its significant advantages in the improvement of construction quality and working
environment, self- compacting concrete (SCC) has been widely accepted by the construction owners.
The use of SCC in practical concrete construction is steadily increasing. Since SCC has to give
satisfactory in situ properties (perfect filling of the mould and embedment of the reinforcement,
homogeneity and full compaction) without vibration, the proper methods for testing the fresh SCC are
very important. These should address three key properties: filling ability, passing ability and resistance
to segregation. It is desirable, especially in the case of new constituents or new concrete compositions,
to test the consistence of fresh SCC before casting in place.
A number of test methods including this test are available for testing fresh SCC. Most of the commonly
used test methods were evaluated in the recently closed EU-project “Testing-SCC” under the 5th Frame
Programme (GRD2-2000-30024/G6RD-CT-2001-00580). According to the results from this EU project,
it seems no single test method can completely cover all three key properties. Nevertheless any test
method should at least be correlated to the practical situation and give consistent results in order to
provide reliable data for judgment of concrete workability.
This standard is one of a series on testing concrete.
EN 12350, Testing fresh concrete, consists of the following parts:
— Part 1: Sampling and common apparatus
— Part 2: Slump test
— Part 3: Vebe test
— Part 4: Degree of compactability
— Part 5: Flow table test
— Part 6: Density
— Part 7: Air content – Pressure methods
— Part 8: Self-compacting concrete – Slump-flow test
— Part 9: Self-compacting concrete – V-funnel test
— Part 10: Self-compacting concrete – L-box test
— Part 11: Self-compacting concrete – Sieve segregation test
— Part 12: Self-compacting concrete – J-ring test
The following amendments have been made to the 2010 edition of this standard:
a) reference to common apparatus and specification given in EN 12350-1;
b) reference and procedure for slump-flow retention testing;
c) option to include specified slump-flow class or slump-flow target value in report.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the
United Kingdom.
1 Scope
This document specifies the procedure for determining the slump-flow and t time for self-
compacting concrete.
The test is suitable for specimens having a declared value of D of the coarsest fraction of aggregates
actually used in the concrete (D ) not greater than 40 mm.
max
2 Normative reference
...