EN 13200-4:2006
(Main)Spectator facilities - Part 4: Seats - Product characteristics
Spectator facilities - Part 4: Seats - Product characteristics
This European Standard specifies the mechanical, physical and chemical product characteristics of fixed seating used in sports venues (indoor and outdoor) in the spectator viewing area (S.V.A.). It also specifies the criteria for fixing the seating to the structure.
These characteristics and criteria are determined in order to assure an adequate resistance to static and dynamic stresses and to atmospheric agents. This European Standard specifies comfort, functionality and safety requirements to prevent serious injury through normal functional use, as well as misuse that might reasonably be excepted to occur. This European Standard does not include any fire behaviour or resistance requirements.
Zuschaueranlagen - Teil 4: Sitze - Produktmerkmale
Dieser europäische Norm-Entwurf legt die mechanischen, physikalischen und chemischen Produktmerkmale
von ortsfest montierten Sitzen im Zuschauerbereich von Sport- und Mehrzweckanlagen (in Innenräumen und
im Freien) fest. Außerdem werden die Kriterien für die Befestigung des Gestühls am Baukörper festgelegt.
Diese Merkmale und Kriterien werden bestimmt, um eine angemessene Beständigkeit gegenüber statischer
und dynamischer Belastung sowie gegenüber witterungsbedingter und luftchemischer Beanspruchung
sicherzustellen. Die Norm legt die Anforderungen an Komfort, Funktionalität und Sicherheit fest, um
ernsthaften Verletzungen sowohl bei üblichen Gebrauch als auch bei Missbrauch vorzubeugen und letzteren
weitestgehend auszuschließen. In dieser Norm sind keine Anforderungen in Bezug auf Brandverhalten und
Beständigkeit enthalten.
Installations pour spectateurs - Partie 4: Sièges - Caractéristiques des produits
Norme Européenne spécifie les caractéristiques mécaniques, physiques et chimiques des sièges fixes utilisés
lors de manifestations sportives (à l’intérieur et à l’extérieur), dans l’espace d’observation des spectateurs.
Elle spécifie également les critères de fixation des sièges à la structure.
Ces caractéristiques et critères sont déterminés dans le but d’assurer une résistance adéquate aux
contraintes statiques et dynamiques ainsi qu’aux agents atmosphériques. La présente Norme Européenne
spécifie des exigences concernant le confort, la fonctionnalité et la sécurité pour prévenir toute blessure grave
pouvant résulter d’une utilisation fonctionnelle normale ainsi que d’un mauvais usage raisonnablement
prévisible. La présente Norme Européenne ne comprend aucune exigence relative au comportement au feu
des sièges.
Prostori za gledalce – 4. del: Lastnosti sedežev
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Spectator facilities - Part 4: Seats - Product characteristicsProstori za gledalce – 4. del: Lastnosti sedeževInstallations pour spectateurs - Partie 4: Sieges - Caractéristiques des produitsZuschaueranlagen - Teil 4: Sitze - ProduktmerkmaleTa slovenski standard je istoveten z:EN 13200-4:2006SIST EN 13200-4:2007en97.220.10Športni objektiSports facilities97.200.10Gledališka, odrska in studijska oprema ter delovne postajeTheatre, stage and studio equipment91.040.10Javne stavbePublic buildingsICS:SLOVENSKI
STANDARDSIST EN 13200-4:200701-marec-2007
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13200-4October 2006ICS 91.040.10; 97.200.10; 97.220.10 English VersionSpectator facilities - Part 4: Seats - Product characteristicsInstallations pour spectateurs - Partie 4: Sièges -Caractéristiques des produitsZuschaueranlagen - Teil 4: Sitze - ProduktmerkmaleThis European Standard was approved by CEN on 28 August 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13200-4:2006: E
Temperature resistance.12 A.1 Temperature resistance.12 A.1.1 General.12 A.1.2 Low temperature test.12 A.1.3 High temperature test.12 Annex B (informative)
Examples of seats.13 Annex C (informative)
Ergonomy.15 C.1 Ergonomy.15 C.1.1 Anthropometric aspects and data.15 C.1.2 Design requirements.15 Bibliography.24
bench, a continuous element, forming a raised seat level with respect to the footway (Figure B.1); low back seat, a shaped element or an assembly fixed to the step or on to a support. It has a backrest with a maximum height of 15 cm above the seat level and may be fitted with armrests (Figure B.2);
Table 1 — Recommended dimensional criteria for seats Row depth (Bse) (mm) Seat type
F (mm)
I (mm)
S (mm)min rec
Bench
Seat with low back
< 150
Seat with high back
> 150
5.2 General requirements for fixing elements and fixing methods 5.2.1 General The fixing of the seats shall comply with the following requirements: a) the fixing elements of the seats shall withstand the forces generated during the tests described in
EN 12727; b) it shall not be possible to remove the seats without the use of a special tool; c) the fixing methods shall be compatible with the supporting structure; d) the metal elements making up the fixing elements and fixing methods shall be protected against corrosion (see 7.2); e) regarding materials, see Clause 6.
...