prEN 17093
(Main)Domestic appliances used for drinking water treatment not connected to water supply - Jug water filter systems - Safety and performance requirements, labeling and information to be supplied
- Abstract
This European Standard describes the specifications and test methods for gravity fed devices for conditioning of drinking water that are not connected to the mains water distribution system in buildings, known as jug water filter systems. It also gives instructions for the user manuals, so that the jug water filter system can be used and maintained properly. Jug water filter systems are intended to modify the properties of drinking water only, and are not designed to make non-potable water safe for drinking. The scope of this document does not extend to combination systems that require an electrical power supply such as water heaters and water coolers systems.
NOTE 1 Although jug water filter systems are covered by the widely harmonized food legislation (EU Regulations 178/2002 and 1935/2004), existing national regulations concerning the use and or the characteristics of these products remain in force
NOTE 2 This standard provides no information as to whether the product is used without restriction in any of the Member States of the EU or EFTA.
- Status
- Not Published
- Publication Date
- 23-Apr-2028
- Current Stage
- 4020 - Submission to enquiry - Enquiry
- Start Date
- 10-Sep-2026
- Due Date
- 08-Jan-2027
- Completion Date
- 08-Jan-2027
prEN 17093 is a CEN draft European Standard for freestanding jug water filter systems used to condition drinking water without connection to a mains water supply. It specifies safety and performance requirements, labeling, and information to be supplied for products that modify drinking water properties, and it is aimed at manufacturers, test laboratories, and anyone assessing whether a jug filter system meets the standard.
What does prEN 17093 specify?
prEN 17093 applies to gravity-fed jug water filter systems used in buildings but not connected to the mains water distribution system. The document covers product specifications, test methods, user instructions, marking, and labeling so the product can be used and maintained correctly.
prEN 17093 also makes clear that jug water filter systems are for modifying drinking water only. It excludes combination systems that need electrical power, such as water heaters and water coolers.
| Annex | What it covers |
|---|---|
| Annex A | Preparation of solutions |
| Annex B | Preparation of challenge water |
| Annex C | Examples of filtration and sampling schedules for chemical tests |
| Annex D | Examples of the microbiological test procedure |
| Annex E | Scale reduction by boiling test |
| Annex F | Synopsis of test procedures and analytical methods |
| Annex G | Examples of test report for each jug |
| Annex H | Substance-specific reduction claims |
| Annex I | Conversion table |
| Annex J | Seal verification test |
What are the key requirements of prEN 17093?
prEN 17093 is built around complete-system testing, defined challenge waters, and declared performance claims. In practice, a manufacturer has to show that the whole jug water filter system, not just the cartridge, meets the claims made for it.
Design and materials
Clause 4 requires the system to be made up of parts such as a jug, hopper, cartridge, cartridge replacement indicator, and lid as applicable. Clause 4.2 requires all materials in contact with inlet water and filtrate to comply with food-contact regulations, and it links the active media to the relevant water-treatment media standards. For an engineer or buyer, this means material compliance is part of the product assessment, not a separate afterthought.
Chemical and microbiological safety
Clause 5 covers filtered water quality, packaging, silver release, and microbiological contamination. If silver is used in the cartridge, the test result has to stay within the document’s limit when tested as specified, and new cartridges must not carry harmful microbial contamination. The system also has to avoid promoting microbiological growth during normal use.
Performance claims
Clause 6 limits how claims are made. prEN 17093 says compliance can only be claimed for a complete unit, and only for the parameters that are actually declared. If several performance parameters are claimed, the lowest declared capacity governs the maximum capacity claim. Additional substance-reduction claims outside the standard are allowed only if tested under the document’s procedures and achieve at least the stated minimum reduction level.
Clause 6 also extends to alternative jug and hopper combinations. A cartridge can be transferred to another system only if it was tested in a reference system, the seal verification in Annex J is satisfied, and the contact time is not reduced below the required level. That matters for interchangeable cartridges and private-label products.
Main chemical performance areas
Clause 6.2 groups the required reduction claims into several areas:
- metal reduction, using challenge water W1
- scale reduction, nitrate reduction, and free chlorine reduction, using challenge water W2
- improvement of organoleptic characteristics, using challenge water W3 or free chlorine as an alternative route
- PFAS reduction, including PFAS-4
- THMs reduction, using chloroform as the surrogate
For practical use, this means the document is not a general drinking-water safety standard. It is a performance standard for specific reduction claims, each tied to a defined test water and analytical method.
Test regime and sampling
Clause 7 sets the test conditions. Two identical systems are tested in parallel, with a third unit used if needed. The test is carried out at room temperature, and the system is run through a weekly pattern of five filtration days followed by two days of stagnation. Sampling is taken at points that correspond to 5 %, 25 %, 50 %, 75 %, and 100 % of nominal capacity.
That matters because the performance is checked over time, not only at the start of use. The document is therefore concerned with both initial filtration behavior and behavior near end of life.
Microbiological testing
Clause 7.3 includes a test for the microbiological condition of a new cartridge and a separate challenge for the potential colonisation of the system with bacterial indicators. Escherichia coli is the indicator organism used in the challenge. The assessment checks whether the system supports microbial growth under repeated use and stagnation.
Instructions for use and marking
Clauses 8 and 9 require instructions on preparation, flushing before use, handling after prolonged non-use, storage, cartridge replacement, disposal, and response to a boil-water notice. Marking and labeling must identify the manufacturer, the standard reference, the declared determinants, batch code, and total cartridge capacity, and the product information must clearly link the cartridge to the tested jug water filter system.
What terms does prEN 17093 define?
- Active medium - the material that changes the water by physical or chemical processes during treatment.
- Cartridge - the replaceable or rechargeable component that contains the active medium.
- Challenge water - water spiked with chemicals or bacteria for carrying out the tests.
- Filtrate - the water that has passed through the active medium.
- Flow rate - the time taken for one litre of water to pass through the cartridge.
- Hopper - the chamber that holds water before it passes through the active medium.
- Jug water filter system - a freestanding water filter device that is not connected to a water supply system.
- Nominal capacity (NC) - the manufacturer-declared volume of treated water for which cartridge performance is guaranteed.
Who uses prEN 17093?
prEN 17093 is used by manufacturers of jug water filter systems and replacement cartridges, especially product development and compliance teams. Test laboratories use it to prepare challenge waters, run chemical and microbiological tests, and compile test reports.
Quality managers, certification bodies, and buyers use it to compare products on a common basis. It is most relevant to domestic water treatment, kitchen equipment, and drinking-water-related consumer products.
What changed in prEN 17093 from the previous edition?
prEN 17093 supersedes EN 17093:2018. The European Foreword states two significant technical changes:
- addition of reduction of PFAS as a chemical requirement
- addition of free chlorine reduction as a chemical requirement
Which standards are used with prEN 17093?
prEN 17093 relies on a large set of normative references. The most important ones are:
- Directive 2020/2184/EC - provides the drinking-water quality context used for the chemical and microbiological requirements
- Regulation (EC) No 1935/2004 and Commission Regulation (EU) No 10/2011 - define food-contact material requirements for parts in contact with water
- EN ISO 3696 - specifies the grade of water used to prepare reagents and test solutions
- EN ISO 11885 and EN ISO 17294-2 - support metal analysis
- EN ISO 7393-2 - supports free chlorine determination
- EN ISO 9308-1 - supports E. coli and coliform testing
- EN 17892 - supports PFAS analysis
- EN 12673 and EN ISO 10301 - support organoleptic and THMs-related analysis
- EN ISO 10304-1, EN ISO 13395, ISO 7890-3, and EN 26777 - support nitrate and nitrite analysis
- the EN 12903, EN 12904, EN 12905, EN 12906, EN 12907, EN 12909, EN 12910, EN 12911, EN 12912, EN 12913, EN 12914, EN 12915-1, EN 13752, EN 13753, EN 13754, EN 14368, and EN 14369 series - define requirements for active media used in the cartridge
What does the prEN 17093 document contain?
prEN 17093 contains a full test-oriented framework for jug water filter systems. It includes solution preparation in Annex A, challenge water recipes in Annex B, sampling schedules in Annex C, microbiological test examples in Annex D, the boiling test for scale reduction in Annex E, and a synopsis of analytical methods in Annex F.
It also provides example test reports in Annex G, guidance for substance-specific reduction claims in Annex H, and a seal verification test in Annex J. These annexes are what turn the standard into a usable laboratory and compliance document: they show how to prepare test media, how to run the filtration cycles, how to sample, and how to document the results.
Relations
- Effective Date
- 18-Feb-2026
Frequently Asked Questions
prEN 17093 is a draft published by the European Committee for Standardization (CEN). Its full title is "Domestic appliances used for drinking water treatment not connected to water supply - Jug water filter systems - Safety and performance requirements, labeling and information to be supplied". This standard covers: This European Standard describes the specifications and test methods for gravity fed devices for conditioning of drinking water that are not connected to the mains water distribution system in buildings, known as jug water filter systems. It also gives instructions for the user manuals, so that the jug water filter system can be used and maintained properly. Jug water filter systems are intended to modify the properties of drinking water only, and are not designed to make non-potable water safe for drinking. The scope of this document does not extend to combination systems that require an electrical power supply such as water heaters and water coolers systems. NOTE 1 Although jug water filter systems are covered by the widely harmonized food legislation (EU Regulations 178/2002 and 1935/2004), existing national regulations concerning the use and or the characteristics of these products remain in force NOTE 2 This standard provides no information as to whether the product is used without restriction in any of the Member States of the EU or EFTA.
This European Standard describes the specifications and test methods for gravity fed devices for conditioning of drinking water that are not connected to the mains water distribution system in buildings, known as jug water filter systems. It also gives instructions for the user manuals, so that the jug water filter system can be used and maintained properly. Jug water filter systems are intended to modify the properties of drinking water only, and are not designed to make non-potable water safe for drinking. The scope of this document does not extend to combination systems that require an electrical power supply such as water heaters and water coolers systems. NOTE 1 Although jug water filter systems are covered by the widely harmonized food legislation (EU Regulations 178/2002 and 1935/2004), existing national regulations concerning the use and or the characteristics of these products remain in force NOTE 2 This standard provides no information as to whether the product is used without restriction in any of the Member States of the EU or EFTA.
prEN 17093 is classified under the following ICS (International Classification for Standards) categories: 97.040.99 - Other kitchen equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
prEN 17093 has the following relationships with other standards: It is inter standard links to EN 17093:2018. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
prEN 17093 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 active medium
- 3.2 cartridge
- 3.3 cartridge replacement indicator
- 3.4 challenge water
- 3.5 filtrate
- 3.6 flow rate
- 3.7 hopper
- 3.8 jug
- 3.9 jug water filter system
- 3.10 maximum usage time
- 3.11 nominal capacity
- 4 Design requirements
- 4.1 Jug water filter system components
- 4.2 Jug water filter system constituent materials
- 5 Chemical and microbiological safety requirements
- 5.1 Filtered water quality
- 5.2 Packaging
- 5.3 Release of silver
- 5.4 Microbiological contamination
- 6 Performance requirements
- 6.1 General
- 6.2 Chemical requirements
- 7 Tests
- 7.1 General
- 7.2 Chemical tests
- 7.3 Microbiological tests
- 8 Instructions for use
- 9 Marking and labelling
- Annex A
- Annex B
- Annex C
- 6 Two-day break from filtration
- 13 Two-day break from filtration
- 20 Two-day break from filtration
- Annex D
- 2 Filtration of 6 l of tap water
- 3 Filtration of 6 l of tap water
- 4 Filtration of 6 l of tap water
- 5 Filtration of 6 l of tap water
- 2 Filtration of 3 l of tap water Sample MB1: overnight Determination of
- 3 Filtration of 3 l of tap water Sample MD1: mixed sample of Determination of
- 4 Filtration of 3 l of tap water Sample ME1: mixed sample of Determination of
- 5 No filtration
- Annex E
- Annex F
- Annex E (for boiling test)
- Annex G
- Annex H
- Annex I
- Annex J
- Bibliography
Introduction
Jug water filter systems are used for the conditioning of drinking water with the objective of optimizing drinking water for specific applications.
oSIST prEN 17093:2026 prEN 17093:2026 (E)
1 Scope
This document describes the specifications and test methods for gravity fed devices for conditioning of drinking water that are not connected to the mains water distribution system in buildings, known as jug water filter systems. It also gives instructions for the user manuals, so that the jug water filter system can be used and maintained properly. Jug water filter systems are intended to modify the properties of drinking water only and are not designed to make non-potable water safe for drinking. The scope of this document does not extend to combination systems that require an electrical power supply such as water heaters and water coolers systems.
NOTE Although jug water filter systems are covered by the widely harmonized food legislation (EU Regulations 178/2002 and 1935/2004), existing national regulations concerning the use and or the characteristics of these products remain in force.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12673, Water quality - Gas chromatographic determination of some selected chlorophenols in water EN 12903, Products used for the treatment of water intended for human consumption - Powdered activated carbon EN 12904, Products used for treatment of water intended for human consumption - Silica sand and silica gravel EN 12905, Products used for treatment of water intended for human consumption - Expanded aluminosilicate EN 12906, Products used for treatment of water intended for human consumption - Pumice EN 12907, Products used for treatment of water intended for human consumption - Pyrolyzed coal material EN 12909, Products used for treatment of water intended for human consumption - Anthracite EN 12910, Products used for treatment of water intended for human consumption - Garnet EN 12911, Products used for treatment of water intended for human consumption - Manganese greensand EN 12912, Products used for treatment of water intended for human consumption - Barite EN 12913, Products used for treatment of water intended for human consumption - Powdered diatomaceous earth EN 12914, Products used for treatment of water intended for human consumption - Powdered perlite EN 12915-1, Products used for the treatment of water intended for human consumption - Granular activated carbon - Part 1: Virgin granular activated carbon EN 13752, Products used for treatment of water intended for human consumption - Manganese dioxide
oSIST prEN 17093:2026 prEN 17093:2026 (E) EN 13753, Products used for treatment of water intended for human consumption - Granular activated alumina EN 13754, Products used for treatment of water intended for human consumption - Bentonite EN 14368, Products used for treatment of water intended for human consumption - Manganese dioxide coated limestone EN 14369, Products used for treatment of water intended for human consumption - Iron-coated granular activated alumina EN 17892, Water quality - Determination of selected per- and polyfluoroalkyl substances in drinking water - Method using liquid chromatography/tandem-mass spectrometry (LC-MS/MS) EN 26777, Water quality - Determination of nitrite - Molecular absorption spectrometric method (ISO 6777) EN ISO 3696, Water for analytical laboratory use - Specification and test methods (ISO 3696) EN ISO 7393-2, Water quality - Determination of free chlorine and total chlorine - Part 2: Colorimetric method using N,N-dialkyl-1,4-phenylenediamine, for routine control purposes (ISO 7393-2) EN ISO 9308-1, Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora (ISO 9308-1) EN ISO 9963-1, Water quality - Determination of alkalinity - Part 1: Determination of total and composite alkalinity (ISO 9963-1) EN ISO 10301, Water quality - Determination of highly volatile halogenated hydrocarbons - Gaschromatographic methods (ISO 10301) EN ISO 10304-1, Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate (ISO 10304-1) EN ISO 10523, Water quality - Determination of pH (ISO 10523) EN ISO 13395, Water quality - Determination of nitrite nitrogen and nitrate nitrogen and the sum of both by flow analysis (CFA and FIA) and spectrometric detection (ISO 13395) EN ISO 11885, Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES) (ISO 11885) EN ISO 17294-2, Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes (ISO 17294-2) ISO 6059, Water quality — Determination of the sum of calcium and magnesium — EDTA titrimetric method ISO 7890-3, Water quality — Determination of nitrate — Part 3: Spectrometric method using sulfosalicylic acid
oSIST prEN 17093:2026 prEN 17093:2026 (E)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https://www.iso.org/obp/
- IEC Electropedia: available at https://www.electropedia.org/
3.1 active medium
active material that significantly changes the composition of the water by physical or chemical processes
3.2 cartridge
replaceable or rechargeable component, which contains the active medium through which the water passes in order to be treated
3.3 cartridge replacement indicator
device indicating the need to replace a cartridge
3.4 challenge water
water spiked with chemicals or inoculated with bacteria, used for carrying out the tests
3.5 filtrate
water that has passed through the filter active medium
3.6 flow rate
time taken for one litre of water to pass through the cartridge
3.7 hopper
separate, removable or non-removable chamber that contains the water before it passes through the active medium
3.8 jug
receptacle that collects the filtrate
3.9 jug water filter system
freestanding water filter device, not connected to a water supply system
3.10 maximum usage time
time in weeks specified by the manufacturer up to which hygienic conditions of the filter are maintained subject to correct operation in accordance with manufacturer’s instructions
oSIST prEN 17093:2026 prEN 17093:2026 (E)
3.11 nominal capacity
(NC) volume in litres of treated water stated by the manufacturer, up to which cartridge performances are guaranteed
4 Design requirements
4.1 Jug water filter system components
The jug water filter system can comprise some or all of the following components:
a) jug; b) hopper; c) cartridge; d) cartridge replacement indicator; e) lid.
NOTE The components of a jug water filter system can vary and might include parts other than those listed. However, this list is representative of most jug water filter systems currently available.
4.2 Jug water filter system constituent materials
All materials used in the jug water filter system coming into contact with inlet water and filtrate shall meet the regulations for materials in contact with food [11] [12]. The active media shall comply with the requirements relating to the water extractable chemical parameters in EN 12903, EN 12904, EN 12905, EN 12906, EN 12907, EN 12909, EN 12910, EN 12911, EN 12912, EN 12913, EN 12914, EN 12915-1, EN 13752, EN 13753, EN 13754, EN 14368, and EN 14369 as appropriate.
For the use of an ion exchange resin, ResAP (2004) 3 [14] shall be considered.
5 Chemical and microbiological safety requirements
5.1 Filtered water quality
For compliance with this European Standard, instructions on the filtered water quality can be found in the European drinking water Directive 2020/2184/EU, Annex 1, Part A and B and any subsequent amendments [1] or appropriate food legislation.
5.2 Packaging
Filter cartridges shall be adequately protected from mechanical damage during shipment and storage. They shall also be individually, hygienically packed to prevent contamination during shipment and storage.
5.3 Release of silver
There is no European regulated limit governing the amount of silver in drinking water. Taking into consideration the information provided in the WHO Guidelines [15], if the cartridge is treated with silver, the average silver concentration when tested in accordance with 7.2.5.3 shall not exceed 80 µg/l.
oSIST prEN 17093:2026 prEN 17093:2026 (E) When testing for silver leachate in a new cartridge, an initial volume of water specified shall be discarded before commencement of use and before testing is carried out.
5.4 Microbiological contamination
5.4.1 Condition on the new cartridge
The new cartridge as delivered to the consumer shall not contain numbers or concentrations of microorganisms constituting a potential danger to the health of the user. When tested in accordance with 7.3.2 sterile filtered challenge water after filtration by a new jug water filter system, shall comply with the microbiological requirements. More instructions can be found in the Drinking Water Directive 2020/2184/EC, Annex 1, Part A [1], as applicable to tap water.
5.4.2 Potential for colonisation of the jug water filter system
During normal use, the jug water filter system shall not promote microbiological growth, therefore, a microbiological challenge test according to 7.3.3 shall be carried out. When tested in accordance with 7.3.3, the sum of the Colony Forming Units (CFU) counts of E.coli for day 2 to day 4 shall not exceed twice the CFU counts of the challenge water, for each of the two challenge weeks.
6 Performance requirements
6.1 General
6.1.1 Compliance with this standard may only be claimed if the jug water filter system has been tested as a complete unit.
The jug water filter system shall only be assessed against the performance claims relevant to the parameters present in the standard.
At least one parameter shall be identified in those performance claims based on the nominal capacity in litres.
If more than one performance parameter is declared for the jug water filter system, the performance parameter with the lowest capacity (in litres) defines the maximum capacity declared. All claims made to this standard shall be clearly separated from other claims or information.
6.1.2 Any additional substance reduction claims (see Annex H) not specifically mentioned in this
standard but tested according to the procedures specified in Clause 7 shall have a reduction rate of at least 90 %.
6.1.3 If a filter cartridge, which has been confirmed to comply with this standard in a specific jug water filter system, is to be used in an alternative system (hopper and jug), compliance of the alternative system can be assumed if:
a) the cartridge has been tested in the jug water filter system with the highest water level above the cartridge (the reference system), and b) a seal verification confirms that the cartridge fits into the alternative jug water filter system(s) with the same seal tightness as in the reference system (see Annex J); c) the contact time for the cartridge is not less than 90 % of that for the originally tested system.
oSIST prEN 17093:2026 prEN 17093:2026 (E)
6.2 Chemical requirements
6.2.1 Reduction of metal contents
When tested according to 7.2.5.2, the average of all of the daily composite filtered water samples from each jug water filter system shall meet the minimum average percentage reduction of the concentration of all of the challenge water according to Table 1 the metal parameters tested. Table 1 — Metal reduction requirements Parameter Concentration unit challenge water Minimum average a Concentration Ci for water W1 (Annex B) percentage reduction +40 Aluminium µg/l Al 60
−20 Copper mg/l Cu +0,6 80
−03, Lead µg/l Pb +20 90
−10 +16 Nickel µg/l Ni 75
−10 a The concentration of aluminium in the challenge water W1 is equal to the parametric value laid down in the Drinking Water Directive; the concentrations of copper, lead and nickel are greater than the corresponding parametric values laid down in the Drinking Water Directive and represent the transient values that may be found in the water at the consumers’ tap after a long stagnation time inside premises and establishments.
6.2.2 Reduction of scale, free chlorine and nitrate contents
When chlorine reduction and nitrate reduction are tested according to 7.2.5.3 or the average of all the daily composite filtered water samples for the respective parameter for each jug water filter system shall meet the minimum average percentage reduction of the concentration of the challenge water according to Table 2.
The scale reduction shall be tested by boiling test in accordance with Annex E, the total limescale deposits from each kettle using filtered water shall be at least 80 % less than total limescale removed from the kettle supplied with untreated water.
oSIST prEN 17093:2026 prEN 17093:2026 (E) Table 2 — Chemical reduction requirements Parameter Concentration unit challenge water Minimum Average Concentration Ci percentage for water W2 (Annex B) reduction b +40 Scale reduction mg/l 30
−20 (Carbonate hardness reduction) b +40 Scale reduction (Boiling mg/l 80
−20 test)
+10 Nitrate mg/l NO 50 a
−5 Free chlorine mg/l Cl +0,2 80
−01, a The concentration of nitrate in the challenge water W1 is equal to the parametric value laid down in the Drinking Water Directive.
b It shall be stated which scale reduction test was used to confirm the performance according to carbonate hardness reduction, boiling test or both whichever is applicable. c In the case of nitrate, to check that no excessive nitrite formation has occurred, the analysis of filtrate samples shall include both nitrate and nitrite, and the following condition shall be met:
CC
NO NO
3 2 +≤ 1 50 3 where C is the concentration in mg/l
6.2.3 Improvement of organoleptic characteristics
When organoleptic reduction is tested according to 7.2.5.4, the daily average of all the filtered water samples for the respective parameter for each jug water filter shall meet the minimum average percentage reduction according to Table 3 or according to Table 4. Separate claims for odour and flavour reduction are not permitted. There are two options for organoleptic testing. Either Geosmin and TCP reduction (6.2.3.1) together or free chlorine reduction (6.2.3.2).
Both Geosmin and 2,4,6-TCP shall be tested together for compliance with this standard. Table 3 — Organoleptic characteristics reduction test by Geosmin and TCP reduction Parameter Concentration unit challenge water Minimum average Concentration Ci percentage reduction for water W3 (Annex B) a 2,4,6-TCP µg/l 2,4,6-TCP 5 (+1/-0,5) 50 b Geosmin µg/l Geosmin 0,05 (+0,01/-0,005) 50 a 2,4,6-trichlorophenol.
b 2,6-dimethylbicyclo[4;4;0]decan-1-ol Free chlorine reduction can be used as an alternative parameter for organoleptic improvement.
oSIST prEN 17093:2026 prEN 17093:2026 (E) Table 4 — Organoleptic characteristics reduction test by free chlorine reduction Parameter Concentration unit challenge water Minimum Average Concentration Ci percentage for water W2 (Annex B) reduction Free chlorine mg/l Cl +0,2 80
−01,
6.2.4 Reduction of PFAS
6.2.4.1 General
Representatives of the PFAS substance class have been included as new chemical parameters in the European Drinking Water Directive (EC) 2020/2184 (Annex I Part B). Considering that PFAS reduction is an evolving topic and that in the future more substances would be needed to be tested for manufacturer’s claims, other PFAS substances than those indicated below should be tested according to Annex H and in consideration with standards or scientific studies available published.
This standard is based on a total limit value of 20 ng/l for PFAS-4, which is adopted by some national and European authorities.
The following representatives of this substance class “PFAS-4” should therefore be tested for reduction performance:
- Perfluorooctanoic acid (PFOA)
- Perfluorooctane sulfonic acid (PFOS)
- Perfluorononanoic acid (PFNA)
- Perfluorohexane sulfonic acid (PFHxS) 6.2.4.2 Determination of the concentration of PFAS-4 in Challenge Water W3 The tests for substance reduction shall be carried out using test water that contains ten times the value stipulated (Table 5).
In this case, it would mean a 10 times concentration of the limit value setting, i.e. 20 ng/l of PFAS-4. Table 5 − PFAS concentration Parameter for Water W3 concentration in challenge Average minimum reduction in (Annex B) water W3 [ng/L] % +10 PFOA 90
−10 +10 PFOS 90
−10 +10 PFNA 90
−10 +10 PFHxS 90
−10 In accordance to these limit values the PFAS-4 concentration of the challenge water is therefore 200 ng/l ± 20 %.
This means, for each single PFAS of PFAS-4 a concentration of 50 ng/l ± 20 % is applicable.
oSIST prEN 17093:2026 prEN 17093:2026 (E) During the test in accordance with 6.2.4, the average value of all daily filter samples from each jug water filter system shall correspond to the reduction of the individual PFAS concentration in accordance with Table 5.
6.2.4.3 PFAS removal performance test
PFAS removal performance test shall be done as follows:
Challenge Water Preparation: Challenge water W3 is prepared in accordance with Annex B. A stock solution containing all of the above PFAS is prepared for PFAS spiking. In order to obtain reproducible results, it shall be ensured that the target concentration of PFAS in the test water remains constant over time (if necessary, methanol shall be used as a solubilizer. This shall be noted in the test report). The test water is freshly spiked with the selected PFAS on a daily basis to minimize the sorption of PFAS on the walls of the storage vessel. The analysis of PFAS in the filtrate shall be performed according to the procedure described in EN 17892.
Water Sampling Water: Sampling shall be carried out according to 7.2.5.3.
6.2.5 THMs reduction
Trihalomethanes (THMs) are by-products of disinfection of drinking water by chlorine. Chloroform is the predominant THM and is used as a surrogate for testing THMs reductions. When tested according to 7.2.5.4, the average of all of the daily composite filtered water samples for each jug water filter shall meet the minimum average percentage reduction of the concentration of the challenge water according to Table 6.
Table 6 — THMs reduction requirements Parameter Concentration unit challenge water Minimum average b Concentration Ci percentage reduction for water W3 (Annex B) a Chloroform µg/l CHCl +20 90
−10 a Used as a representative of all THMs.
b The concentration of chloroform in the challenge water W1 is equal to the parametric value of total THMs laid down in the Drinking Water Directive.
7 Tests
7.1 General
The jug water filter system shall be commissioned and maintained in accordance with the conditions specified for use throughout the test.
Two identical jug water filter systems shall be tested in parallel. If one of the two does not give the required results, a third jug water filter system shall be tested. If the test with the third jug water filter system gives required results, the test is successful.
The test procedure shall be carried out at room temperature of 22 °C ± 3 °C.
...