Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature for preformed pipe insulation

This European Standard specifies the equipment and procedures for determining the maximum service temperature for preformed pipe insulation. It is applicable to thermal insulating products.

Wärmedämmstoffe für die Haustechnik und für betriebstechnische Anlagen - Bestimmung der oberen Anwendungsgrenztemperatur von vorgeformten Rohrdämmstoffen

Dieses Dokument legt Prüfeinrichtungen und Verfahren zur Bestimmung der oberen Anwendungsgrenz-temperatur von vorgeformten Rohrdämmstoffen fest. Es gilt für Wärmedämmprodukte.

Produits isolants thermiques pour l'équipement du bâtiment et les installations industrielles - Détermination de la température maximale de service des coquilles isolantes préformées

La présente Norme européenne spécifie l'équipement et les modes opératoires servant à déterminer la température maximale de service des coquilles isolantes préformées. Elle s’applique aux produits isolants thermiques.

Toplotnoizolacijski proizvodi za opremo stavb in industrijske inštalacije - Ugotavljanje najvišje temperature servisiranja predoblikovanih cevnih izolacij

General Information

Status
Withdrawn
Publication Date
04-Dec-2007
Withdrawal Date
16-Oct-2012
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
17-Oct-2012
Completion Date
17-Oct-2012

Relations

Buy Standard

Standard
EN 14707:2006+A1:2008
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature for preformed pipe insulationToplotnoizolacijski proizvodi za opremo stavb in industrijske inštalacije - Ugotavljanje najvišje temperature servisiranja
predoblikovanih cevnih izolacijProduits isolants thermiques pour l'équipement du bâtiment et les installations industrielles - Détermination de la température maximale de service des coquilles isolantes préforméesWärmedämmstoffe für die Haustechnik und für betriebstechnische Anlagen - Bestimmung der oberen Anwendungsgrenztemperatur von vorgeformten RohrdämmstoffenTa slovenski standard je istoveten z:EN 14707:2005+A1:2007SIST EN 14707:2006+A1:2008en,fr,de91.100.60ICS:SIST EN 14707:20061DGRPHãþDSLOVENSKI
STANDARDSIST EN 14707:2006+A1:200801-marec-2008

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14707:2005+A1
December 2007 ICS 91.100.60 Supersedes EN 14707:2005 English Version
Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature for preformed pipe insulation
Produits isolants thermiques pour l'équipement du bâtiment et les installations industrielles - Détermination de la température maximale de service des coquilles isolantes préformées
Wärmedämmstoffe für die Haustechnik und für betriebstechnische Anlagen - Bestimmung der oberen Anwendungsgrenztemperatur von vorgeformten Rohrdämmstoffen This European Standard was approved by CEN on 19 October 2005 and includes Amendment 1 approved by CEN on 28 October 2007.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2007 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14707:2005+A1:2007: E

Modifications of and additions to the general test method for mineral wool products.13 Annex B (normative)
Modifications of and additions to the general test method for polyethylene foam (PEF) and flexible elastomeric foam (FEF) products.15 Annex C (normative)
Modifications of and additions to the general test method for phenolic foam products.18 Bibliography.20

Key 1 Device for measuring thickness, e. g. electromechanical
device 2a
Test length of the test specimen 2b Test specimen end guard 3 End insulation 4 Small gap
5 Circumferential joints 6 Thermocouples 7 Hot pipe 8 Power supply and temperature control a) General arrangement
All dimensions in millimetres
Key 1 Device for measuring thickness, e.g. electromechanical device 2 Thermocouple 3 Hot pipe
4 Test specimen 5 Flexible metal foil 6 Weights for loading b) Test specimen loading arrangement Figure 1 — Example of an apparatus for determining maximum service temperature

6 Test specimens 6.1 Dimensions of test specimens Length: The test specimen, length (1 000 ± 10) mm, shall be cut at right angles to its length to give two end guards, length each (250 ± 5) mm, and a test length of (500 ± 5) mm. Thickness: The thickness shall be 100 mm or the largest thickness below 100 mm available. Inside diameter: Two sizes shall be tested, one between 25 mm and 65 mm and the other between 85 mm and 220 mm. The dimensions shall be as specified in the relevant product standard or annex to this European Standard. NOTE 1 In the absence of a product standard or any other European Technical Specification, the dimensions may be agreed between parties. NOTE 2 Testing may be performed on multi-layer systems to simulate the conditions existing in the application. If the pipe insulation is cut from a homogeneous, isotropic flat product, then the maximum service temperature can be obtained from tests carried out on the flat product with similar properties in accordance with EN 14706. 6.2 Number of test specimens The number of test specimens shall be as specified in the relevant pr
...

Questions, Comments and Discussion