FprEN 13651
(Main)Soil improvers and growing media - Extraction of calcium chloride/DTPA (CAT) soluble nutrients and elements
- Abstract
This document specifies an extraction method for the routine determination of calcium chloride/DTPA (CAT-method) extractable nutrients and elements in organic soil improver, inorganic soil improver, growing medium, compost and digestate.
NOTE This method has been validated in an interlaboratory study with specific products that were present on the market during the study (as included in Annex B, being coir pith (0 mm to12 mm, washed and buffered), composted bark (20 mm to 40 mm), biowaste compost (Rottegrad 3), green compost (Rottegrad 5, 0 mm to 15 mm), solid digestate (centrifuged and dried, raw sieved 0 mm to 12 mm), expanded clay (whole granules, 8 mm to 16 mm), blend 1 (white peat, green compost, wood fibre, lime, inorganic fertilizer (NPK + micro elements)), blend 2 (white peat, black peat, expanded perlite, lime, organic fertilizer) and blend 3 (white peat, black peat, clay, inorganic fertilizer (NPK + micro elements))).
- Status
- Not Published
- Publication Date
- 09-Feb-2027
- Technical Committee
- CEN/TC 223 - Soil improvers and growing media
- Drafting Committee
- CEN/TC 223/WG 4 - Analytical methods
- Current Stage
- 5060 - Closure of Vote - Formal Approval
- Start Date
- 19-Nov-2026
- Due Date
- 15-Feb-2025
- Completion Date
- 15-Feb-2025
FprEN 13651 is the CEN draft European Standard for extracting calcium chloride/DTPA (CAT) soluble nutrients and elements from organic soil improver, inorganic soil improver, growing medium, compost and digestate. It specifies the CAT extraction method, how to prepare and treat the test sample, how to determine the extracted elements, and how to express and report the results. It is written for laboratories and technical users who need routine measurements on these materials.
What does FprEN 13651 specify?
FprEN 13651 specifies a routine extraction method for CAT-soluble nutrients and elements in the material groups named in the scope. The method is organized as a laboratory procedure, from sampling references and sample preparation through extraction, filtration, measurement, result calculation and test reporting.
| Annex | What it covers |
|---|---|
| Annex A | Examples of analytical methods for determining the extracted nutrients and elements |
| Annex B | Performance characteristics from the interlaboratory validation |
Clause 7 points to EN 12579:2024 for sampling, and Clause 8 points to prEN 13040-1:2025 for laboratory sample preparation and laboratory bulk density. Clause 13 records the validation basis and performance data for the method.
What are the key requirements of FprEN 13651?
FprEN 13651 sets out a fixed extraction chemistry, controlled conditions, and a defined way to report results. In practice, this means a laboratory must follow the sample handling and calculation rules closely if it wants comparable CAT values.
Extraction conditions and reagents
- Clause 4 requires extraction with calcium chloride/DTPA at 22 °C ± 3 °C and an extraction volume ratio of 1 to 5. This standardizes the contact between sample and extractant so that results are comparable across laboratories.
- Clause 5 specifies reagent quality, water purity and the CAT extracting solution. The solution is prepared from calcium chloride and DTPA, diluted to the stated molar concentrations, and adjusted to the required pH range. If soluble calcium is being determined, Clause 4 allows a barium chloride/DTPA solution of the same molar concentration.
- Clause 6 stresses contamination control, including cleaning vessels, using suitable stoppers, and avoiding borosilicate glassware when boron is determined. For the user, this reduces the risk of false high values caused by trace contamination.
Sample preparation and extraction steps
- Clause 7 links sampling to EN 12579:2024, so the laboratory should receive a representative sample that has not been altered in transport or storage.
- Clause 8 requires preparation of the laboratory sample in accordance with prEN 13040-1:2025 and determination of laboratory bulk density. That bulk density is later needed if results are reported on a dry matter basis.
- Clause 9 separates solid materials by sieve-related categories and also covers pre-shaped material. The different sample forms are extracted with fixed sample-to-extractant proportions, then shaken for 1 hour at the stated temperature. This matters because the method adapts to particle size and product form without changing the extraction principle.
- Clause 9 also requires filtration, with alternative clarification techniques allowed when paper filtration is too slow, as long as the technique is reported. The extract can be stored refrigerated for a short period or frozen for longer storage, which helps with batch work and outsourced analysis.
Measurement and reporting
- Clause 10 says the extracted nutrients and elements are determined by appropriate methods, and Annex A gives examples. The standard therefore defines the extraction step, while leaving the measurement technique to the analyte and the laboratory equipment.
- Clause 11 requires subtraction of the reagent blank, multiplication by the extraction factor, and expression of results on an as-received basis. It also gives the route for dry matter reporting using prEN 13040-1:2025 data, and states the conversion of phosphorus to phosphorus pentoxide and potassium to potassium oxide. For users, this means the report can support fertilizer-style nutrient expressions as well as substrate-based values.
- Clause 12 lists the minimum test report content: the standard reference, sample identification, results, any non-standard or optional operations, factors affecting results, and laboratory bulk density. That makes the result traceable and easier to audit.
Validation
- Clause 13 states that the method was validated in accordance with ISO 5725-2 and gives reproducibility and repeatability data in Annex B. Annex B covers nine validated matrices, including coir pith, composted bark, biowaste compost, green compost, solid digestate, expanded clay and three blends. This tells the reader where the method has been demonstrated in practice.
What terms does FprEN 13651 define?
FprEN 13651 uses the terms and definitions from CEN/TS 17732:2022, so the method follows the shared vocabulary for soil improvers and growing media.
- CAT-method - the calcium chloride/DTPA extraction method used to release the soluble nutrients and elements measured by this standard.
- DTPA - diethylenetriaminepentaacetic acid, the chelating agent used in the extractant.
- dm - dry matter content of the sample, used when results are converted from fresh basis to dry matter basis.
- Laboratory bulk density - the fresh-sample bulk density measured in the laboratory and used in the dry-matter conversion.
- Reagent blank - the blank value used to check and correct for contamination from reagents, glassware or filter paper.
- Repeatability - the short-range precision condition used in Annex B to describe variation between results under the same laboratory conditions.
- Reproducibility - the between-laboratory precision condition used in Annex B to describe variation across laboratories.
Who uses FprEN 13651?
FprEN 13651 is used by laboratories that test soil improvers, growing media, compost and digestate for nutrient and element content. It is relevant to producers, quality control teams, technical buyers and third-party testing bodies that need routine CAT extraction results for product characterization, specification checks or lot comparison. It also supports method selection in laboratories that report nutrients such as ammonium-N, nitrate-N, phosphorus, potassium and trace elements.
What changed in FprEN 13651 from the previous edition?
FprEN 13651 will supersede EN 13651:2001. The foreword states these main technical changes:
- the title has been changed;
- Clause 4 on the principle has been completed;
- the procedure has been updated with new types of test samples;
- Clause 11 on expression of results has been completed with conversion factors and a dry matter calculation;
- Annex A on methods of analysis has been updated.
Which standards are used with FprEN 13651?
| Standard | What it contributes |
|---|---|
| CEN/TS 17732:2022 | Terms and definitions for soil improvers and growing media |
| EN 12579:2024 | Sampling of soil improvers and growing media |
| prEN 13040-1:2025 | Laboratory sample preparation, dry matter content and laboratory bulk density |
| ISO 5725-2 | Validation approach and precision data treatment used for the method validation |
What does the FprEN 13651 document contain?
FprEN 13651 contains a complete laboratory extraction procedure, from reagents and apparatus to filtration, measurement and reporting. It also includes example analytical methods for the extracted analytes in Annex A, so users can match the extraction step with a suitable measurement technique. Annex B presents interlaboratory performance data for multiple matrices, which helps laboratories judge method behavior on different products. The bibliography points to the analytical standards and validation background used in the document.
Relations
- Effective Date
- 15-May-2019
Get Certified
Connect with accredited certification bodies for this standard

Control Union Certifications
Global certification for agriculture and sustainability.

ECOCERT
Organic and sustainability certification.

FSC International
Forest Stewardship Council certification.
Sponsored listings
Frequently Asked Questions
FprEN 13651 is a draft published by the European Committee for Standardization (CEN). Its full title is "Soil improvers and growing media - Extraction of calcium chloride/DTPA (CAT) soluble nutrients and elements". This standard covers: This document specifies an extraction method for the routine determination of calcium chloride/DTPA (CAT-method) extractable nutrients and elements in organic soil improver, inorganic soil improver, growing medium, compost and digestate. NOTE This method has been validated in an interlaboratory study with specific products that were present on the market during the study (as included in Annex B, being coir pith (0 mm to12 mm, washed and buffered), composted bark (20 mm to 40 mm), biowaste compost (Rottegrad 3), green compost (Rottegrad 5, 0 mm to 15 mm), solid digestate (centrifuged and dried, raw sieved 0 mm to 12 mm), expanded clay (whole granules, 8 mm to 16 mm), blend 1 (white peat, green compost, wood fibre, lime, inorganic fertilizer (NPK + micro elements)), blend 2 (white peat, black peat, expanded perlite, lime, organic fertilizer) and blend 3 (white peat, black peat, clay, inorganic fertilizer (NPK + micro elements))).
This document specifies an extraction method for the routine determination of calcium chloride/DTPA (CAT-method) extractable nutrients and elements in organic soil improver, inorganic soil improver, growing medium, compost and digestate. NOTE This method has been validated in an interlaboratory study with specific products that were present on the market during the study (as included in Annex B, being coir pith (0 mm to12 mm, washed and buffered), composted bark (20 mm to 40 mm), biowaste compost (Rottegrad 3), green compost (Rottegrad 5, 0 mm to 15 mm), solid digestate (centrifuged and dried, raw sieved 0 mm to 12 mm), expanded clay (whole granules, 8 mm to 16 mm), blend 1 (white peat, green compost, wood fibre, lime, inorganic fertilizer (NPK + micro elements)), blend 2 (white peat, black peat, expanded perlite, lime, organic fertilizer) and blend 3 (white peat, black peat, clay, inorganic fertilizer (NPK + micro elements))).
FprEN 13651 is classified under the following ICS (International Classification for Standards) categories: 65.080 - Fertilizers. The ICS classification helps identify the subject area and facilitates finding related standards.
FprEN 13651 has the following relationships with other standards: It is inter standard links to EN 13651:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
FprEN 13651 is associated with the following European legislation: EU Directives/Regulations: 2019/1009; Standardization Mandates: M/564, M/564 Amd 1, M/564 Amd 2, M/XXX. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
FprEN 13651 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Principle
- 5 Reagents
- 5.1 General
- 5.2 Reagents
- 6 Apparatus
- 6.1 General
- 6.2 Apparatus
- 7 Sampling
- 8 Test sample
- 9 Procedure
- 9.1 Safety
- 9.2 Extraction of material in solid form
- 9.3 Extraction of material in pre shaped form
- 9.4 Filtration
- 10 Determination of the extracted nutrients and elements
- 11 Expression of results
- 12 Test report
- 13 Validation of the method
- 13.2 Performance characteristics
- Annex A
- Annex B
- Bibliography
1 Scope
This document specifies an extraction method for the routine determination of calcium chloride/DTPA (CAT-method) extractable nutrients and elements in organic soil improver, inorganic soil improver, growing medium, compost and digestate.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. CEN/TS 17732:2022, Soil improvers and growing media - Terminology EN 12579:2024, Soil improvers and growing media - Sampling prEN 13040-1:2025, Soil improvers and growing media — Sample preparation — Part 1: Sample preparation for chemical and physical tests, determination of dry matter content, moisture content and laboratory bulk density
3 Terms and definitions
For the purposes of this document, the terms and definitions given in CEN/TS 17732:2022 apply.
4 Principle
A sample is extracted with calcium chloride/DTPA at 22 °C ± 3 °C in an extraction volume ratio of 1 to 5. The extracted nutrients and elements are determined by various methods as appropriate (see Annex A). If soluble calcium is to be determined, a barium chloride/DTPA solution with the same molar concentration may be used.
5 Reagents
5.1 General
All reagents used shall be of recognized analytical quality and water with a specific conductivity not higher than 0,2 mS/m at 25 °C, free from the elements to be determined.
5.2 Reagents
5.2.1 Dihydrated calcium chloride, CaCl ·2H O.
2 2 5.2.2 Diethylenetriaminepentaacetic acid (DTPA), C H N O .
14 23 3 10 5.2.3 Hydrochloric acid, c(HCl) = 1:1 vol/vol.
5.2.4 Concentrated extracting solution CaCl /DTPA, (CAT), dissolve 14,7 g CaCl ·2H O (5.2.1) and
2 2 2 7,88 g DTPA (5.2.2) in 800 ml hot water (temperature approximately 80 °C) with stirring on a magnetic stirrer in a 1 000 ml beaker. At 75 °C ± 10 °C the reagents will dissolve within 2 h. Allow to cool to ambient temperature. Transfer the solution to a 1 000 ml flask and dilute to the mark with water. The solution is stable at room temperature for several weeks. Any precipitation that occurs will disappear with warming and stirring.
oSIST prEN 13651:2025 prEN 13651:2025 (E) 5.2.5 Extracting solution CaCl /DTPA, (CAT), dilute the concentrated extracting solution (5.2.4) with
water in the proportions one part concentrated solution with nine parts water. The final concentration of the extracting solution should be 0,01 mol/l CaCl and 0,002 mol/l DTPA. The pH of the extracting
solution should be adjusted if necessary to be between 2,6 and 2,65 by using HCl (5.2.3). 5.2.6 Nitric acid, c(HNO ) = 15 mol/l: ⍴ ≈ 1,42 g/ml; not less than 65 % mass/volume.
5.2.7 Nitric acid, c(HNO ) = 0,5 mol/l, dilute 35 ml nitric acid (5.2.6) to one litre with water.
6 Apparatus
6.1 General
NOTE It has been found convenient to carefully clean the equipment (e.g. using nitric acid) and keep separate sets of glassware for the determination of Boron, in order to reduce the possibility of within-laboratory contamination.
All glass apparatus and plastic vessels used in the procedure should be subject to an appropriate preparation procedure in order to keep the risk of contamination as low as possible. It is recommended that all vessels (glass and plastic) are cleansed by carefully immersing in warm nitric acid (5.2.7) for a minimum of 6 h and then rinsed in water.
Rubber stoppers, which may contain traces of metals shall not be used. It is recommended to use plastic or any other stopper free of all substances to be analysed.
Borosilicate glassware shall not be used if boron is to be determined.
6.2 Apparatus
The apparatus consists of the usual laboratory apparatus, and in particular the following:
6.2.1 Plastic bottles or containers, sufficiently large (500 ml to 2 000 ml) with screw cap to
accommodate the volume of the sample, extractant and at least 10 % air volume. 6.2.2 Shaking or mixing machine, capable of holding the plastic bottles or containers (6.2.1) and maintaining the sample in suspension without damaging the structure of the sample. The use of a horizontal table shaker is recommended.
6.2.3 Filter paper, cellulose-based ashless types, with a medium pore size of approximately 8 µm and diameter of 150 mm.
6.2.4 Analytical balance with an accuracy of 10 mg.
7 Sampling
Sampling is not part of the method specified in this document. EN 12579:2024 shall be followed dealing with soil improvers and growing media. It is important that the laboratory receives a sample that is representative of the product under consideration. The sample should not have been damaged or changed during transport or storage.
8 Test sample
Prepare the laboratory sample in accordance with prEN 13040-1:2025, Clause 9, and determine the laboratory bulk density of the sample in accordance with prEN 13040-1:2025, Annex A.
oSIST prEN 13651:2025 prEN 13651:2025 (E)
9 Procedure
9.1 Safety
SAFETY PRECAUTIONS — Care should be taken when handling substances of caustic nature or samples that may contain sharps or is of a dusty nature.
9.2 Extraction of material in solid form
9.2.1 Test samples passing through a 20 mm sieve
Take a weight equivalent to 60 ml of the sample volume (prEN 13040-1:2025, Clause 9.2.5) to the nearest 1 g and transfer to the container (6.2.1). Add 300 ml of extracting solution (5.2.5), secure the cap and shake for 1 h on the shaking machine (6.2.2) at 22 °C ± 3 °C. Perform the measurement at least 2 times to obtain a mean value.
9.2.2 Test samples passing through a 40 mm sieve (≤20 % or 20-40 % retained on the sieve)
Take a weight equivalent to 250 ml of the sample volume (prEN 13040-1:2025, Clause 9.2.3 a) or b)) to the nearest 1 g and transfer to the container (6.2.1). Add 1 250 ml of extracting solution (5.2.5) secure the cap and shake for 1 h on the shaking machine (6.2.2) at 22 °C ± 3 °C. Perform the measurement at least 2 times to obtain a mean value.
9.2.3 Test samples passing through a 40 mm sieve (>40 % retained on the sieve)
Take a weight equivalent to 300 ml of the sample volume (prEN 13040-1:2025, Clause 9.2.13 c)) to the nearest 1 g and transfer to the container (6.2.1). Add 1 500 ml of extracting solution (5.2.5), secure the cap and shake for 1 h on the shaking machine (6.2.2) at 22 °C ± 3 °C. Perform the measurement at least 2 times to obtain a mean value.
9.3 Extraction of material in pre shaped form
Take a weight equivalent to 150 ml of the sample volume (prEN 13040-1:2025, Clause 9.5.3) to the nearest 1 g and transfer to the 1 000 ml container (6.2.1). Add 750 ml of extracting solution (5.2.5), secure the cap and shake for 1 h on the shaking machine (6.2.2) at 22 °C ± 3 °C. Before filtration pour out the fluid and the pre-shaped sample in a beaker. Squeeze the pre-shaped sample in the beaker as much as possible by applying a pressure to the sample with help of a plastic masher or pestle. Perform the measurement at least 2 times to obtain a mean value.
9.4 Filtration
Filter through filter paper (6.2.3) discarding at least the first 10 ml. In some cases, paper filtration is too slow or even impossible. In such cases, alternative procedures prior to paper filtration (e.g. centrifugation) for obtaining a clear supernatant are acceptable and the technique used shall be reported. The filtered extract is stable for three days in a hermetically closed polyethylene bottle if stored in a refrigerator at 3 °C ± 2 °C. The filtrate may be stored for longer periods in a deep freezer at about –18 °C. Before using a solution that has been frozen, the thawed solution should be thoroughly mixed to eliminate gradient separation that occurs on freezing and subsequent thawing. The measurement of a blank may be used to check possible contaminations of the extracting solution, glassware and filter paper used.
10 Determination of the extracted nutrients and elements
Appropriate methods for the determination of the extracted nutrients and elements shall be used. Examples are provided in Annex A.
oSIST prEN 13651:2025 prEN 13651:2025 (E)
11 Expression of results
Subtract the values determined for the reagent blank from those obtained for the samples; results shall be multiplied by 5 (the extraction volume ratio) and expressed in mg/l substrate as received basis. If results shall be expressed on a dry matter basis (e.g. Nickel), the dry matter content of sample (dm) shall be determined according to prEN 13040-1:2025 (Clause 11) and used in Formula (1):
mg mg 1 =×× 1000 (1) kg l dm% LD×
where L is the laboratory-determined bulk density of fresh sample (in g/l) D dm% is the dry matter percentage of sample Phosphorus pentoxide (P O ) shall be calculated by multiplying phosphorus (P) with the factor 2,29. 2 5 Potassium oxide (K O) shall be calculated by multiplying potassium (K) with the factor 1,20. The total
extractable nitrogen shall be calculated as the sum of ammonium nitrogen and nitrate nitrogen.
12 Test report
The test report shall contain the following information:
a) a reference to this document (including its year of publication); b) all information necessary for complete identification of the sample; c) the results of the determination, expressed as mg/l sample; NOTE For macronutrients, results can be expressed in whole numbers for microelements with three significant digits.
d) details of any operations not specified in this document or regarded as optional, as well as any factor which may have affected the results; e) the laboratory bulk density;
13 Validation of the method
13.1 Validation in accordance with ISO 5725-2 This standardized reference method was validated in accordance with ISO 5725-2 [1]. All relevant data were reported in an interlaboratory study report, which has been published [15].
13.2 Performance characteristics
The performance characteristics (reproducibility and repeatability) of the method were determined in an interlaboratory study. All data are given in Annex B. The method has been validated for nine different matrices, as listed in Table B.1 to B.17.
oSIST prEN 13651:2025 prEN 13651:2025 (E)
Annex A
(informative)
Examples of methods of analysis used for the determination of nutrients and elements In Table A.1, examples for methods for the determination of nutrients and elements are provided. Table A.1 — Examples for methods for the determination of nutrients and elements Element Method (Numbered References in Bibliography) Ammonium-N 3, 4, 5 Nitrate-N 6, 7 Phosphorus 7, 8, 9, 14 Potassium 8, 9, 10 Magnesium 8, 9 Sulfate-S 7, 8 Sodium 8, 9, 10 Boron 8, 9, 11, 12 Copper 8, 9,12,13 Iron 8, 9, 12 Manganese 8, 9, 12, 13 Molybdenum 8, 9, 12 Zinc 8, 9, 12, 13 Cadmium 8, 9, 13 Nickel 8, 9, 13 Lead 8, 9, 13 Calcium 8, 9
oSIST prEN 13651:2025 prEN 13651:2025 (E)
Annex B
(informative)
Performance characteristics of the method The interlaboratory study of extraction of calcium chloride/DTPA (CAT) soluble nutrients and elements in growing media and soil improvers was carried out with 8 European laboratories in 7 countries on 9 different materials. The different materials, listed in Table B.1, were chosen to represent soil improvers and growing media materials as broadly as possible. Detailed information can be found in the final report on the validation study [15].
...