Resilient, textile and laminate floor coverings - Design, preparation and installation - Part 4: Resilient floor coverings

This Technical Specification provides recommendations for the installation of resilient floor coverings.  It covers products composed of polyvinyl chloride, linoleum, cork and rubber.  It details suitable methods of installation and advises on the selection of the materials required for their implementation.
The guidelines in this Technical Specification are intended for use in cases where manufacturer's instructions, taking account of the national code of practice in the country where the installation is to be made, are not available. References to the national codes that are currently available are listed in the Bibliography of the various parts of this Technical Specification.
This Technical Specification is intended for use in conjunction with CEN/TS 14472-1 that deals with general matters relevant to textile and laminate floor coverings as well as resilient floor coverings. It gives recommendations for the installation of resilient floor coverings in new or existing buildings.  It describes common procedures which are in use throughout Europe and highlights the major differences that can exist in different national procedures.
Special measures beyond those described in this Technical Specification may be necessary for the successful installation of resilient floor coverings for specialist purposes such as electrostatic control or use in special wet areas.  These specialist techniques are not described in this Technical Specification.

Elastische, textile und Laminatbodenbeläge - Planung, Vorbereitung und Verlegung - Teil 4: Elastische Bodenbeläge

Diese Technische Spezifikation gibt Empfehlungen für die Verlegung von elastischen Bodenbelägen. Diese umfasst Produkte aus Polyvinylchlorid, Linoleum, Kork und Gummi. Sie beschreibt geeignete Verfahren für die Verlegung und berät bei der Auswahl der für ihre Anwendung erforderlichen Materialien.
Die Richtlinien dieser Technischen Spezifikation sind - unter Berücksichtigung der Bestimmungen des Landes, in dem der Bodenbelag verlegt werden soll, - für die Fälle vorgesehen, wo Herstelleranweisungen fehlen.  Aktuelle geltende nationale Bestimmungen sind in den Literaturhinweisen der verschiedenen Teile dieser Technischen Spezifikation aufgeführt.
Diese Technische Spezifikation soll in Verbindung mit prCEN/TS 14472-1 benutzt werden, der allgemeine Angelegenheiten bezüglich textilen und Laminatbodenbelägen sowie elastischen Bodenbelägen behandelt. Er enthält Empfehlungen für die Verlegung elastischer Bodenbeläge in Neubauten oder vorhandenen Gebäuden. Er beschreibt europaweit übliche Verfahren für Planung, Verlegung und Pflege, und geht besonders auf die großen möglichen Unterschiede zwischen den verschiedenen nationalen Verfahren ein.
Für die erfolgreiche Verlegung elastischer Bodenbeläge für Spezialzwecke können über die in dieser Technischen Spezifikation beschriebenen Maßnahmen hinaus spezielle Verfahren erforderlich sein, wie elektrostatische Kontrolle oder Verwendung in Nassbereichen. Diese speziellen Arbeitstechniken sind in diesem Bericht nicht enthalten.

Revêtements de sol résilients, textiles et stratifiés - Conception, préparation et installation - Partie 4: Revêtements de sols résilients

Netekstilne, tekstilne in laminatne talne obloge – Načrtovanje, priprava in namestitev – 4. del: Netekstilne talne obloge

General Information

Status
Withdrawn
Publication Date
17-Jun-2003
Withdrawal Date
22-Aug-2023
Current Stage

Buy Standard

Technical specification
TS CEN/TS 14472-4:2003
English language
15 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2003
1HWHNVWLOQHWHNVWLOQHLQODPLQDWQHWDOQHREORJH±1DþUWRYDQMHSULSUDYDLQ
QDPHVWLWHY±GHO1HWHNVWLOQHWDOQHREORJH
Resilient, textile and laminate floor coverings - Design, preparation and installation - Part
4: Resilient floor coverings
Elastische, textile und Laminatbodenbeläge - Planung, Vorbereitung und Verlegung - Teil
4: Elastische Bodenbeläge
Revetements de sol résilients, textiles et stratifiés - Conception, préparation et
installation - Partie 4: Revetements de sols résilients
Ta slovenski standard je istoveten z: CEN/TS 14472-4:2003
ICS:
97.150 Netekstilne talne obloge Non-textile floor coverings
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

TECHNICAL SPECIFICATION
CEN/TS 14472-4
SPÉCIFICATION TECHNIQUE
TECHNISCHE SPEZIFIKATION
June 2003
ICS: 97.150
English version
Resilient, textile and laminate floor coverings - Design,
preparation and installation - Part 4: Resilient floor coverings
Revêtements de sol résilients, textiles et stratifiés - Elastische, textile und Laminatbodenbeläge - Planung,
Conception, préparation et installation - Partie 4: Vorbereitung und Verlegung - Teil 4: Elastische
Revêtements de sols résilients Bodenbeläge
This Technical Specification (CEN/TS) was approved by CEN on 30 september 2002 for provisional application.
The period of validity of this CEN/TS is limited initially to three years. After two years the members of CEN will be requested to submit their
comments, particularly on the question whether the CEN/TS can be converted into a European Standard.
CEN members are required to announce the existence of this CEN/TS in the same way as for an EN and to make the CEN/TS available. It
is permissible to keep conflicting national standards in force (in parallel to the CEN/TS) until the final decision about the possible
conversion of the CEN/TS into an EN is reached.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2003 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TS 14472-4:2003 E
worldwide for CEN national Members.

Contents Page
Foreword. 3
1 Scope . 5
2 Normative references . 5
3 Terms and definitions. 5
4 Exchange of information. 5
5 Materials. 6
5.1 Smoothing compounds or underlayments. . 6
5.2 Underlayments . 6
5.3 Underlays. 6
5.4 Selection of floor coverings. 6
6 Subfloors . 6
6.1 General. 6
6.2 Board and strip floors . 8
6.3 Wood blocks. 8
6.4 Particleboard floating floors. 8
6.5 Other bases . 8
6.6 Fabricated substrates. 9
7 Installation . 9
7.1 General. 9
7.2 Inspection of goods. 10
7.3 Existing floor coverings . 10
7.4 Underfloor heating. 10
7.5 Planning of layout. 10
7.6 Temperature during installation. 11
7.7 Adhesives . 11
7.8 Welding . 11
7.9 Stairs . 12
7.10 Skirtings, covings, edges, and dividing strip . 12
7.11 Conductive floor coverings . 12
8 Completion . 13
Bibliography . 14
Foreword
This document (CEN/TS 14472-4:2003) has been prepared by Technical Committee CEN/TC 134 “Resilient,
textile and laminate floor coverings”, the secretariat of which is held by BSI.
CEN/TS 14472, Resilient, textile and laminate floor coverings — Design, preparation and installation, consists of
the following four parts:
Part 1: General
Part 2: Textile floor coverings
Part 3: Laminate floor coverings
Part 4: Resilient floor coverings
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by December 2003, and conflicting national standards shall be withdrawn
at the latest by December 2003.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to announce this Technical Specification: Austria, Belgium, Czech Republic, Denmark,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands,
Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and the United Kingdom.
Introduction
European Standards are currently available for
- resilient, textile and laminated floor coverings
- classification schemes, which define the characteristics of a location where a floor covering is to be used, and
enable an appropriate product to be selected.
For these products to give satisfactory service, they also need to be installed competently, and to receive
appropriate maintenance in service.
Certain countries have issued guides and/or standards that define good practice for installation and
maintenance.
To date, although there has been substantial trade in floor coverings between different countries in Europe,
these have largely been installed using the methods of the country importing them. Relatively little installation
work has been conducted across European borders, but it is likely that this will increase.
This Technical Specification is not intended to replace the existing national guides or standards on installation.
Its purpose is:
a) to identify a framework of good practice common to the existing national standards,
b) to identify the principal technical differences in approach between them,
and hence
c) to foster good standards of installation across Europe, including countries where there is no national
standard on
d) to enable a specifier to specify a common procedure for installation for work in his country, which may be
conducted by installers from other countries, and
e) to enable an installer to conduct work more easily in another country.
1 Scope
This Technical Specification provides recommendations for the installation of resilient floor coverings. It
covers products composed of polyvinyl chloride, linoleum, cork and rubber. It details suitable methods of
installation and advises on the selection of the materials required for their implementation.
The guidelines in this Technical Specification are intended for use in cases where manufacturer's instructions,
taking account of the national code of practice in the country where the installation is to be made, are not
available. References to the national codes that are currently available are listed in the Bibliography of the
various parts of this Technical Specification.
This Technical Specification is intended for use in conjunction with CEN/TS 14472-1 that deals with general
matters relevant to textile and laminate floor coverings as well as resilient floor coverings. It gives
recommendations for the installation of resilient floor coverings in new or existing buildings. It describes
common procedures which are in use throughout Europe and highlights the major differences that can exist in
different national procedures.
Special measures beyond those described in this Technical Specification may be necessary for the successful
installation of resilient floor coverings for specialist purposes such as electrostatic control or use in special wet
areas. These specialist techniques are not described in this Technical Specification.
2 Normative references
This Technical Specification incorporates by dated or undated reference, provisions from other publications.
These normative references are cited at the appropriate places in the text, and the publications are listed
hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to
this Technical Specification only when incorporated in it by amendment or revision. For undated references
the latest edition of the publication referred to applies (including amendments).
EN 12466 Resilient floor coverings – Vocabulary.
CEN/TS 14472-1:2003 Resilient, textile and laminate floor coverings – Design, preparation and installation
– Part 1: general.
3 Terms and definitions
For the purposes of this Technical Specification, the terms and definitions given in EN 12466, and CEN/TS
14472-1 apply, together with the following.
Specific national terms may be found in national glossaries or standards (see Bibliography).
3.1
underlayment
thin layer, applied to a screed to provide a smooth and/or flat surface to receive the floor covering.
4 Exchange of information
In order for the correct floor covering to be installed in appropriate conditions, at the right time, etc., it is
essential that all parties have a clear understanding of the requirements of the project, e.g. new build or
refurbishment, and of the implications for all concerned. To ensure that this is achieved, it is essential that
there is wide consultation between all parties involved in the project, including sub-contractors and materials
suppliers. This consultation should start early in the design stage but will be necessary throughout the
contract, especially should requirements or time scales change and as new sub-contract work is initiated. As
each project will be unique it is impossible to give a definitive list of the information to be exchanged, but the
typical examples, applying to textile and laminate floor coverings as well as to resilient floor coverings are
given in CEN/TS 14472-1.
5 Materials
5.1 Smoothing compounds or underlayments.
These materials are used to smooth uneven floors, or to improve the suction to assist the application of primers
or adhesives. The traffic and loads expected in service should be considered and an underlayment with
appropriate properties and classification should be selected for use in that area.
5.2 Underlayments
Underlayments may be selected from the following:
a) cementitious underlayment consisting of a specially formulated blend of cement, binder and fine
aggregate. The binder is commonly a natural rubber or synthetic polymer dispersion;
b) powder/water mixes based on casein/cement or polymer/cement and fine aggregate;
c) epoxy or other resin compounds (e.g. primer);
d) compatible underlayments that are available for direct contact with
...

Questions, Comments and Discussion