EN 1393:1996/AC:1997
(Corrigendum)Plastics piping systems - Glass-reinforced thermosetting plastics (GRP) pipes - Determination of initial longitudinal tensile properties
Plastics piping systems - Glass-reinforced thermosetting plastics (GRP) pipes - Determination of initial longitudinal tensile properties
Kunststoff-Rohrleitungssysteme - Rohre aus glasfaserverstärkten duroplastischen Kunststoffen (GFK) - Bestimmung der Anfangs-Zugeigenschaften in Längsrichtung
Systèmes de canalisations en plastiques - Tubes en plastiques thermodurcissables renforcés de verre (PRV) - Détermination des propriétés initiales en traction longitudinale
Cevni sistemi iz polimernih materialov - Cevi iz duromernih materialov, okrepljenih s steklenimi vlakni (GRP) - Ugotavljanje začetnih nateznih lastnosti v vzdolžni smeri
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.VPHULKunststoff-Rohrleitungssysteme - Rohre aus glasfaserverstärkten duroplastischen Kunststoffen (GFK) - Bestimmung der Anfangs-Zugeigenschaften in LängsrichtungSystemes de canalisations en plastiques - Tubes en plastiques thermodurcissables renforcés de verre (PRV) - Détermination des propriétés initiales en traction longitudinalePlastics piping systems - Glass-reinforced thermosetting pl
...
This May Also Interest You
This document specifies the characteristics of pipes for crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures according to the class of application (see ISO 15875-1:2025, Table 1).
This document also specifies the test parameters for the test methods referred to in this document.
It is applicable to PE-X pipes with and without barrier layer.
This document is applicable to PE-X pipes for hot and cold water installations, which are intended to be connected to fittings conforming to ISO 15875-3, whereby the joints conform to the requirements of ISO 15875-5.
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Oct-2025
- 23.040.20
- 91.140.60
- CEN/TC 155
This document specifies the characteristics of the fitness for purpose of crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 15875-1:2025, Table 1).
This document also specifies the test parameters for the test methods referred to herein.
This document is applicable to joints between pipes conforming to ISO 15875-2 and fittings made of plastics and non-plastics materials conforming to ISO 15875-3, for hot and cold water installations.
- Standard16 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Oct-2025
- 23.040.20
- 91.140.60
- CEN/TC 155
This document gives guidance and requirements for the assessment of conformity of materials, products, joints and assemblies in accordance with the applicable part(s) of EN 13476 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1 A test matrix provides an overview of the testing scheme in Annex A, Table A.1.
NOTE 2 If certification is involved, the certification body operating in accordance with EN ISO/IEC 17065 [1] and EN ISO/IEC 17020 [2] is considered to be competent.
In conjunction with EN 13476-1:2025, EN 13476-2:2025 and EN 13476-3:2025 this document is applicable to Plastics piping systems for non-pressure underground drains and sewers — Structural-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE).
The application area code used in the marking of pipes and fittings indicates for which application area(s) the products are intended:
U: for the area more than 1 m from the building to which the buried piping system is connected, and
UD: for application area U and the area under and within 1 m from the building where the pipes and the
fittings are buried in ground and are connected to the soil and waste discharge system of the building.
- Technical specification30 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Oct-2025
- 23.040.20
- 93.030
- CEN/TC 155
This document specifies the characteristics of pipes made from polyethylene (PE) for piping systems in the field of the supply of gaseous fuels.
NOTE 1 Additional information related to the installation of PE 100-RC systems is given in EN 1555-1:2025, Annex A.
NOTE 2 Additional information about the suitability of PE pipe systems for hydrogen and its admixtures is given in EN 1555-1:2025, Annex B.
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 1555-1, EN 1555-3, EN 1555-4 and EN 1555-5, this document is applicable to PE pipes, fittings and valves, their joints, and joints with components of PE and other materials intended to be used under the following conditions:
a) a maximum operating pressure, MOP, up to and including 10 bar at a design reference temperature of 20 °C;
b) an operating temperature between −20 °C and 40 °C.
For operating temperatures between 20 °C and 40 °C derating coefficients are specified in EN 1555-5.
The EN 1555 series covers a range of MOPs and gives requirements concerning colours.
This document is applicable to three types of pipe:
- PE pipes (outside diameter, dn) including any identification stripes;
- PE pipes with co-extruded layers on either or both the outside and/or inside of the pipe (total outside diameter, dn) as specified in Annex A, where all PE layers have the same MRS rating;
- PE pipes (outside diameter, dn) with a peelable and contiguous thermoplastics additional layer on the outside of the pipe (”coated pipe”) as specified in Annex B.
It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
- Standard33 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Oct-2025
- 23.040.20
- CEN/TC 155
This document, together with EN 13476-1, specifies the definitions and requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are intended for use in non-pressure underground drains and sewers for foul wastewater.
NOTE 1 Products complying with this document can also be used in non-pressure underground drains and sewers for surface water.
This document is applicable to pipes and fittings with smooth internal and profiled external surfaces, designated as Type B.
This document also specifies test methods and test parameters.
This document is applicable to:
a) structured-wall pipes and fittings, which are intended to be used buried underground outside the building structure, reflected in the marking of products by “U”; and
b) structured-wall pipes and fittings, which are intended to be used buried underground both outside (application area code “U”) and within the building structure, reflected in the marking of products by “UD”.
This document is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints.
This document is applicable to a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes, application areas, tolerance classes and gives recommendations concerning colours.
NOTE 2 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
- Standard62 pagesEnglish languagesale 10% offe-Library read for×1 day
- 07-Oct-2025
- 23.040.01
- 23.040.05
- 23.040.20
- 93.030
- CEN/TC 155
This document specifies product category rules (PCR) for Environmental Product Declarations (EPDs), as described in EN ISO 14025 and EN 15942.
This document is applicable to:
- functional unit as plastic piping systems buried outside building structure;
- declared unit as one or more main structural components, as specified by the list of product standards provided in Annex CC.
Main structural components are:
- pipes;
- fittings (e.g. flange couplers, bends and reducers, valves and electrofusion fittings);
- manholes, inspection chambers and infiltration boxes.
This document gives guidelines for both pressure and non-pressure applications.
The intended function of the system considered is to convey fluids according to EN 476 (for sewers, drain and surface water), EN 805 (water supply), or EN 12007 (gas supply).
This document provides in Annex DD a non-exhaustive list of application fields. In addition, the following applications and materials are not in scope of this document: GRP pipes and fittings, and district heating pipes.
This document specifies the rules for the product category of construction products as defined in and is intended to be used in conjunction with EN 15804+A2.
In addition to EN 15804+A2, this document specifies:
- the functional unit (consisting of pipes, fittings, manholes and inspection chambers and ancillary components) and declared unit (consisting of pipes and/or fittings and/or manholes and /or inspection chambers);
- the system boundaries and additional mandatory modules to be declared;
- the processes to be included in the installation phase;
- scenarios for module A4, A5;
- use conditions for the use phase (B modules);
- reference service life (RSL);
- end of life scenarios.
- Standard40 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Sep-2025
- 23.040.20
- 23.040.45
- 91.010.99
- CEN/TC 155
This document specifies product category rules (PCR) for Environmental Product Declarations (EPDs), as described in EN ISO 14025 and EN 15942.
This document is applicable to:
- functional unit as plastics piping systems inside the building structure;
- declared unit as one or more main structural components which are represented by pipes and fittings, as specified by the list of product standards provided in Annex CC.
This document gives guidelines for:
- both pressure and non-pressure applications;
- metal fittings (including manifolds) which are used in a plastic piping system.
The intended function of the system considered is to convey liquids according to EN 806 (for potable water supply), EN 1264 (for heating and cooling systems), EN 12828 (for radiators), EN 12056 (for soil and waste discharge and for water traps).
This document specifies product category rules of construction products as defined in and is intended to be used in conjunction with EN 15804+A2.
This document provides in Annex DD a non-exhaustive list of application fields. In addition, the insulated pipes are not in the scope of this document.
In addition to EN 15804+A2, this document specifies:
- the functional unit (consisting of pipes, fittings and ancillary components) and declared unit (consisting of pipes and/or fittings);
- the system boundaries and additional mandatory modules to be declared;
- the processes to be included in the installation phase;
- scenarios for module A4, A5;
- reference service life (RSL);
- end of life scenarios.
- Standard36 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Sep-2025
- 23.040.20
- 23.040.45
- 91.010.99
- CEN/TC 155
This document specifies a method to determine the resistance to internal pressure of polyethylene (PE), crosslinked polyethylene (PE-X) and unplasticized (PA-U) pipes to verify the condition of the pipe after being subjected to a squeeze-off procedure.
The equipment and procedure used to prepare the test samples and test parameters are given in this document, i.e.:
a) the diameter and series of the pipe to be tested (see 6.1);
b) the number of test pieces (see 6.2);
c) the parameters for the hydrostatic strength tests (see 7.6).
NOTE 1 Further information on the squeeze-off procedure is given in EN 12007-2 and ISO/TS 10839 for polyethylene, and CEN/TS 12007-6 for unplasticized polyamide.
NOTE 2 The squeeze-off procedure is specified to limit gas flow to allow maintenance, repair or to make network connections. Squeeze-off is used in an emergency for pipes carrying other media.
- Standard11 pagesEnglish languagesale 10% offe-Library read for×1 day
- 06-May-2025
- 23.040.20
- 305/2011
- CEN/TC 155
This document specifies procedures suitable for the analysis of data which, when converted into logarithms of the values, have either a normal or a skewed distribution. It is intended for use with test methods and referring standards for glass-reinforced thermosetting plastics (GRP) pipes or fittings for the analysis of properties as a function of time. However, it can also be used for the analysis of other data.
Two methods are specified, which are used depending on the nature of the data. Extrapolation using these techniques typically extends a trend from data gathered over a period of approximately 10 000 h to a prediction of the property at 50 years, which is the typical maximum extrapolation time.
This document only addresses the analysis of data. The test procedures for collecting the data, the number of samples required and the time period over which data are collected are covered by the referring standards and/or test methods. Clause 6 discusses how the data analysis methods are applied to product testing and design.
- Standard27 pagesEnglish languagesale 10% offe-Library read for×1 day
- 25-Feb-2025
- 23.040.20
- 23.040.45
- CEN/TC 155
This document gives guidance and requirements for the assessment of conformity of materials (compounds/formulations), products, joints and assemblies in accordance with EN 17670 2 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1 A test matrix provides an overview of the testing scheme in Annex A, Table A.1.
NOTE 2 If certification is involved, the certification body operating in accordance with EN ISO/IEC 17065 [1] and EN ISO/IEC 17020 [2] is considered to be competent.
In conjunction with EN 17670 2 this document is applicable to road gullies.