Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010)

ISO 8253-1:2010 specifies procedures and requirements for pure-tone air conduction and bone conduction threshold audiometry. For screening purposes, only pure-tone air conduction audiometric test methods are specified. It is possible that the procedures are not appropriate for special populations, e.g. very young children.
ISO 8253-1:2010 does not cover audiometric procedures to be carried out at levels above the hearing threshold levels of the subjects.
Procedures and requirements for speech audiometry, electrophysiological audiometry, and where loudspeakers are used as a sound source are not specified.

Akustik - Audiometrische Prüfverfahren - Teil 1: Grundlegende Verfahren der Luft- und Knochenleitungs-Schwellenaudiometrie mit reinen Tönen (ISO 8253-1:2010)

Dieser Teil von ISO 8253 legt Verfahren und Anforderungen für Luft- und Knochenleitungs-Reinton-
Schwellenaudiometrie fest. Für audiometrische Screening-Tests werden nur Reinton-Luftleitungs-Verfahren
beschrieben. Die Verfahren sind möglicherweise für besondere Gruppen, z. B. sehr junge Kinder, nicht
geeignet.
Audiometrische Verfahren, die bei Pegeln über der Hörschwelle der Probanden durchgeführt werden, sind
nicht Gegenstand dieses Teils von ISO 8253.
Verfahren und Anforderungen für die Sprachaudiometrie, elektrophysiologische Audiometrie und Verfahren,
bei denen Lautsprecher als Schallquellen eingesetzt werden, werden nicht festgelegt.

Acoustique - Méthodes d'essais audiométriques - Partie 1: Audiométrie à sons purs en conduction aérienne et en conduction osseuse (ISO 8253-1:2010)

L'ISO 8253-1:2010 spécifie des modes opératoires et des exigences relatives à l'audiométrie liminaire à sons purs en conduction aérienne et en conduction osseuse. En ce qui concerne l'audiométrie de dépistage, seules sont décrites des méthodes audiométriques liminaires tonales en conduction aérienne. Il est possible que les modes opératoires ne conviennent pas à certaines populations, par exemple aux très jeunes enfants.
L'ISO 8253-1:2010 ne traite pas des méthodes audiométriques devant être exécutées à des niveaux dépassant les niveaux liminaires d'audition des sujets testés.
Les modes opératoires et les exigences relatifs à l'audiométrie vocale, à l'audiométrie électrophysiologique et à l'usage de haut-parleurs pour délivrer les sons ne sont pas spécifiés.

Akustika - Avdiometrijske preskusne metode - 1. del: Avdiometrija s čistimi toni za zračno in kostno prevodnost (ISO 8253-1:2010)

Ta del ISO 8253 opredeljuje postopke in zahteve za avdiometrijo s čistimi toni za zračno prevodnost in avdiometrijo pragovnih vrednosti za kostno prevodnost. Za presajanje so opredeljene le metode avdiometrije s čistimi zvoki za zračno prevodnost. Mogoče je, da ti postopki niso primerni za vse prebivalce, npr. zelo majhne otroke. Ta del ISO 8253 ne zajema postopkov avdiometrije, ki se izvajajo na ravneh nad slišnim pragom oseb. Postopki in zahteve za avdiometrijo govora, elektrofiziološko avdiometrijo in pri uporabi zvočnika kot vira hrupa niso opredeljeni.

General Information

Status
Published
Publication Date
31-Oct-2010
Withdrawal Date
30-May-2011
Technical Committee
Drafting Committee
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
01-Nov-2010
Completion Date
01-Nov-2010

Relations

Buy Standard

Standard
EN ISO 8253-1:2011
English language
38 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-marec-2011
1DGRPHãþD
SIST EN 26189:1999
SIST EN ISO 8253-1:1999
$NXVWLND$YGLRPHWULMVNHSUHVNXVQHPHWRGHGHO$YGLRPHWULMDVþLVWLPLWRQL]D
]UDþQRLQNRVWQRSUHYRGQRVW ,62
Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction
audiometry (ISO 8253-1:2010)
Akustik - Audiometrische Prüfverfahren - Teil 1: Grundlegende Verfahren der Luft- und
Knochenleitungs-Schwellenaudiometrie mit reinen Tönen (ISO 8253-1:2010)
Acoustique - Méthodes d'essais audiométriques - Partie 1: Audiométrie à sons purs en
conduction aérienne et en conduction osseuse (ISO 8253-1:2010)
Ta slovenski standard je istoveten z: EN ISO 8253-1:2010
ICS:
13.140 Vpliv hrupa na ljudi Noise with respect to human
beings
17.140.01 $NXVWLþQDPHUMHQMDLQ Acoustic measurements and
EODåHQMHKUXSDQDVSORãQR noise abatement in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN ISO 8253-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2010
ICS 13.140 Supersedes EN 26189:1991, EN ISO 8253-1:1998
English Version
Acoustics - Audiometric test methods - Part 1: Pure-tone air and
bone conduction audiometry (ISO 8253-1:2010)
Acoustique - Méthodes d'essais audiométriques - Partie 1: Akustik - Audiometrische Prüfverfahren - Teil 1:
Audiométrie à sons purs en conduction aérienne et en Grundlegende Verfahren der Luft- und Knochenleitungs-
conduction osseuse (ISO 8253-1:2010) Schwellenaudiometrie mit reinen Tönen (ISO 8253-1:2010)
This European Standard was approved by CEN on 25 September 2010.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2010 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 8253-1:2010: E
worldwide for CEN national Members.

Contents Page
Foreword .3

Foreword
This document (EN ISO 8253-1:2010) has been prepared by Technical Committee ISO/TC 43 “Acoustics” in
collaboration with Technical Committee CEN/TC 211 “Acoustics” the secretariat of which is held by DS.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by May 2011, and conflicting national standards shall be withdrawn at the
latest by May 2011.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 26189:1991 and EN ISO 8253-1:1998.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
Endorsement notice
The text of ISO 8253-1:2010 has been approved by CEN as a EN ISO 8253-1:2010 without any modification.

INTERNATIONAL ISO
STANDARD 8253-1
Second edition
2010-11-01
Acoustics — Audiometric test methods —
Part 1:
Pure-tone air and bone conduction
audiometry
Acoustique — Méthodes d'essais audiométriques —
Partie 1: Audiométrie à sons purs en conduction aérienne et en
conduction osseuse
Reference number
ISO 8253-1:2010(E)
©
ISO 2010
ISO 8253-1:2010(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.

©  ISO 2010
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2010 – All rights reserved

ISO 8253-1:2010(E)
Contents Page
Foreword .v
Introduction.vi
1 Scope.1
2 Normative references.1
3 Terms and definitions .2
4 General aspects of audiometric measurements .4
4.1 General .4
4.2 Standard reference zero for the calibration of audiometric equipment .5
4.3 Requirements on audiometric equipment .5
4.4 Qualified tester .5
4.5 Test time.5
4.6 Conditions for audiometric test environments .5
4.7 Measurement uncertainty.6
5 Preparation and instruction of test subjects before audiometric testing and positioning of
transducers .6
5.1 Preparation of test subjects .6
5.2 Instruction of test subjects.7
5.3 Placement of transducers .7
6 Air conduction hearing threshold level determinations using fixed-frequency audiometry .7
6.1 General .7
6.2 Manually controlled threshold determination .8
6.3 Hearing threshold determination with an automatic recording audiometer.10
6.4 Computer-controlled threshold determination.12
7 Air conduction hearing threshold level determinations using sweep-frequency
audiometry .12
7.1 General .12
7.2 Presentation of test tone .12
7.3 Familiarization .12
7.4 Hearing threshold level measurement .12
7.5 Calculation of hearing threshold level at a specified frequency.12
8 Bone conduction hearing threshold audiometry .13
8.1 Method of audiometry.13
8.2 Occlusion .13
8.3 Airborne sound radiation from the bone vibrator.13
8.4 Vibrotactile sensation .13
8.5 Procedures for testing with masking in bone conduction audiometry .13
9 Screening audiometry.14
9.1 General .14
9.2 Procedure for the screening test .14
10 Audiograms.15
11 Permissible ambient noise .16
11.1 Permissible ambient noise for threshold determinations.16
11.2 Psycho-acoustic check on ambient noise.16
12 Maintenance and calibration of audiometric equipment.20
12.1 General .20
12.2 Intervals between checks .20
ISO 8253-1:2010(E)
12.3 Stage A — Routine checking and subjective tests . 20
12.4 Stage B — Periodic objective checks. 21
12.5 Stage C — Basic calibration tests. 22
Annex A (informative) Measurement uncertainty . 23
Bibliography. 28

iv © ISO 2010 – All rights reserved

ISO 8253-1:2010(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.