EN 4644-001:2012
(Main)Aerospace series - Connector, electrical and optical, rectangular, modular, rectangular inserts, operating temperature 175 °C (or 125 °C) continuous - Part 001: Technical specification
Aerospace series - Connector, electrical and optical, rectangular, modular, rectangular inserts, operating temperature 175 °C (or 125 °C) continuous - Part 001: Technical specification
This European Standard specifies the required characteristics, the condition for qualification, acceptance and quality assurance for electrical and optical rectangular connectors with single or multiple removable rectangular inserts for use in a temperature range from 65 °C to 175 °C continuous for electrical contact.
This family of connectors is particularly suitable for aeronautic use in zones of severe environmental conditions on board aircraft, applying EN 2282.
Inserts for fiber optic contacts or mixing fiber optic contacts and electrical contacts are described in EN 4639-002.
Luft- und Raumfahrt - Elektrische und optische Rechtecksteckverbinder, modular, rechteckige Kontakteinsätze, Dauerbetriebstemperatur 175 °C (oder 125 °C) konstant - Teil 001: Technische Lieferbedingungen
Diese Europäische Norm legt die Anforderungen, die Bedingungen für die Qualifikation, Abnahme und Quali-tätssicherung von elektrischen und optischen Steckverbindern mit rechteckigem Querschnitt und einzelnen oder mehreren rechteckigen Einsätzen zur Herstellung elektrischer Kontakte bei einer Dauerbetriebstempera-tur von −65 °C bis 175 °C fest. Diese Familie von Steckverbindern ist besonders für den Einsatz in der Luftfahrt unter rauen Umgebungsbe-dingungen an Bord von Luftfahrzeugen nach EN 2282 geeignet. Einsätze für optische Kontakte oder die Mischung von optischen und elektrischen Kontakten sind in EN 4639-002 beschrieben.
Série aérospatiale - Connecteur, électrique et optique, rectangulaire, modulaire, à inserts rectangulaires, température de fonctionnement 175 °C (ou 125 °C) continu - Partie 001 : Spécification technique
La présente Norme européenne spécifie les caractéristiques requises, les conditions de qualification, d'acceptation et d'assurance de la qualité pour les connecteurs rectangulaires électriques et optiques avec des inserts rectangulaires simples ou multiples démontables pour être utilisés dans une plage de température de - 65 °C à 175 °C continu pour les contacts électriques.
Cette famille de connecteurs est particulièrement appropriée pour une utilisation aéronautique dans des zones aux conditions environnementales sévères à bord des aéronefs, suivant l'EN 2282.
Les inserts pour les contacts pour fibres optiques ou mixant contacts pour fibres optiques et contacts électriques sont définis dans l'EN 4639-002.
Aeronavtika - Konektor, električni in optični, pravokotni, modularni, pravokotni vložki, stalna delovna temperatura 175 °C (ali 125 °C) - 001. del: Tehnične specifikacije
Ta evropski standard določa zahtevane značilnosti, pogoje kvalifikacije, sprejemljivosti in zagotavljanja kakovosti za električne in optične pravokotne konektorje z enim ali več pravokotnimi vložki, ki jih je mogoče odstraniti, za uporabo pri stalni temperaturi med - 65 °C in 175 °C za električni kontakt. Ta družina konektorjev je zlasti ustrezna za aeronavtično uporabo na letalih na območjih z neugodnimi okoljskimi pogoji, pri čemer se uporablja standard EN 2282. Vložki za kontakte iz optičnih vlaken ali mešanico kontaktov iz optičnih vlaken in električnih kontaktov so opisani v standardu EN 4639-002.
General Information
- Status
- Withdrawn
- Publication Date
- 29-May-2012
- Withdrawal Date
- 20-Jan-2026
- Technical Committee
- ASD-STAN - Aerospace
- Drafting Committee
- ASD-STAN/D 2 - Electrical
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 18-Oct-2017
- Completion Date
- 28-Jan-2026
Relations
- Effective Date
- 08-Jun-2022
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
- Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard
National Aerospace and Defense Contractors Accreditation Program (NADCAP)
Global cooperative program for special process quality in aerospace.

NSF-ISR
NSF International Strategic Registrations.
Orion Registrar Inc.
US-based certification body for management systems.
Sponsored listings
Frequently Asked Questions
EN 4644-001:2012 is a standard published by the European Committee for Standardization (CEN). Its full title is "Aerospace series - Connector, electrical and optical, rectangular, modular, rectangular inserts, operating temperature 175 °C (or 125 °C) continuous - Part 001: Technical specification". This standard covers: This European Standard specifies the required characteristics, the condition for qualification, acceptance and quality assurance for electrical and optical rectangular connectors with single or multiple removable rectangular inserts for use in a temperature range from 65 °C to 175 °C continuous for electrical contact. This family of connectors is particularly suitable for aeronautic use in zones of severe environmental conditions on board aircraft, applying EN 2282. Inserts for fiber optic contacts or mixing fiber optic contacts and electrical contacts are described in EN 4639-002.
This European Standard specifies the required characteristics, the condition for qualification, acceptance and quality assurance for electrical and optical rectangular connectors with single or multiple removable rectangular inserts for use in a temperature range from 65 °C to 175 °C continuous for electrical contact. This family of connectors is particularly suitable for aeronautic use in zones of severe environmental conditions on board aircraft, applying EN 2282. Inserts for fiber optic contacts or mixing fiber optic contacts and electrical contacts are described in EN 4639-002.
EN 4644-001:2012 is classified under the following ICS (International Classification for Standards) categories: 49.060 - Aerospace electric equipment and systems; 49.090 - On-board equipment and instruments. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 4644-001:2012 has the following relationships with other standards: It is inter standard links to EN 4644-001:2017, EN 2591-407:1999, EN 2591-6301:2001, EN 2591-401:1996, EN 2591-6406:2001, EN 2591-427:2001, EN 2591-416:2001, EN 2591-508:2023, EN 2591-502:2001, EN 2591-409:1999, EN 2591-312:1997, EN 2591-208:1996, EN 9100:2018, EN 2591-503:2001, EN 2591-708:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 4644-001:2012 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.VSHFLILNDFLMHLuft- und Raumfahrt - Elektrische und optische Rechtecksteckverbinder, modular, rechteckige Kontakteinsätze, Dauerbetriebstemperatur 175 °C (oder 125 °C) konstant - Teil 001: Technische LieferbedingungenSérie aérospatiale - Connecteur, électrique et optique, rectangulaire, modulaire, à inserts rectangulaires, température de fonctionnement 175 °C (ou 125 °C) continu - Partie 001: Spécification techniqueAerospace series - Connector, electrical and optical, rectangular, modular, rectangular inserts, operating temperature 175 °C (or 125 °C) continuous - Part 001: Technical specification49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 4644-001:2012SIST EN 4644-001:2012en01-september-2012SIST EN 4644-001:2012SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 4644-001
May 2012 ICS 49.060; 49.090 English Version
Aerospace series - Connector, electrical and optical, rectangular, modular, rectangular inserts, operating temperature 175 °C (or 125 °C) continuous - Part 001: Technical specification
Série aérospatiale - Connecteur, électrique et optique, rectangulaire, modulaire, à inserts rectangulaires, température de fonctionnement 175 °C (ou 125 °C) continu - Partie 001: Spécification technique
Luft- und Raumfahrt - Elektrische und optische Rechtecksteckverbinder, modular, rechteckige Kontakteinsätze, Dauerbetriebstemperatur 175 °C (oder 125 °C) konstant - Teil 001: Technische LieferbedingungenThis European Standard was approved by CEN on 6 August 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 4644-001:2012: ESIST EN 4644-001:2012
disconnect aligning housing cavity DNC:
disconnect non aligning housing cavity N : extremity of insert retention clip reference plane P : front face of hard insert R : vertical axis of housing backshell interface RAC:
rack & panel aligning housing cavity RNC:
rack & panel non Aligning housing cavity S : horizontal axis of housing backshell interface T : backshell bottoming reference plane on housing X : horizontal axis of insert Y : vertical axis of insert
1) Published by: DoD National (US) Mil. Department of Defense http://www.defenselink.mil/ 2) Published by: SAE National (US) Society of Automotive Engineers http://www.sae.org/ SIST EN 4644-001:2012
two rack and panel (blind mate) connector housing sizes; it is a size three housing and a size four housing which have respectively three and four insert cavities all with one keyway, three polarizing posts or keys offering 64 polarizing positions and no locking mechanism. In addition to this rack and panel use, the size four male connector can be mated with two size 2 female connectors in a disconnect application by using two centre coupling mechanisms. These connectors use different types of contacts (signal, power, coaxial, triaxial, quadrax, etc.) see EN 3155-002 and optical contacts see EN 4639-002. SIST EN 4644-001:2012
Aligning cavities guaranty not only the alignment between male and female housing but also guarantee the shell to shell bottoming. Non aligning female housing cavities have a circular location tolerance. In order to define how alignment of the female and male housing is achieved a dimension line between the two housing aligning cavities is defined. SIST EN 4644-001:2012
Key 1 Dimensions for housing size 1 2 Dimension for housing size n (n > 1) 3 Dimension of grounding device (optional) Figure 1 – Disconnect panel female aligning cavity (DAC) SIST EN 4644-001:2012
Key 1 Dimension of grounding device (optional) Figure 2 — Disconnect panel female aligning cavity (DNC) SIST EN 4644-001:2012
Key 1 Dimension for grounding device
Figure 3 —
Rack and panel female aligning cavity (RAC) SIST EN 4644-001:2012
Key 1 Dimension for grounding device (optional) Figure 4 — Rack and panel female non aligning cavity (RNC) SIST EN 4644-001:2012
Key 1 Dimension for housing size 1 2 Dimension for housing size n (n > 1) Figure 5 — Disconnect panel male aligning cavity (DAC) SIST EN 4644-001:2012
Figure 6 — Disconnect panel male non aligning cavity (DNC) SIST EN 4644-001:2012
Figure 7 — Rack and panel male aligning cavity (RAC) SIST EN 4644-001:2012
Figure 8 — Rack and panel male non aligning cavity (RNC) 4.4 Rear accessories See EN 4644-002. 4.5 Inserts The insert assembly shall be single-bloc type design complete with contact retention systems and appropriate seals. The female inserts use female contacts and male inserts use male contacts. These inserts use contacts of size 22, 20, 16, 12, 8 and 5. The inserts are rear release rear removable from the housing. Male and female inserts can be installed either in the male or female housing. There are inserts with one polarizing rib (A polarizing position) and inserts with two polarizing ribs (B polarizing position). This means that there are inserts dedicated to housing cavities with one keyway and inserts dedicated to housing cavities with two keyways. See Table 1 below. SIST EN 4644-001:2012
A blank insert is installed in a housing cavity where no contact is required. This blank insert has no polarizing rib and the same dimensions as an insert for pin contacts. It can be installed in any male or female housing cavity. This blank insert can mate without causing any interference with an insert for male contacts or with an insert for female contacts. The blank insert does not provide sealing. 4.6 Keying mechanism Size 1, 3 and 4 housings have a polarizing system using polarizing posts having a L shape cross section and polarizing keys having a L shape cavity to mate with the polarizing posts. Each polarizing post and key provides 4 polarizing positions. Each post and key is retained in the housing by a special shape which allowed them to be clipped in the housing. Size 1 housings have two polarizing pins offering 16 polarizing positions. Size 3 and 4 housings have three polarizing pins offering 64 polarizing positions.
The size 2 housing has either a centre coupling screw or coupling nut which ensure also the polarizing function. The coupling screw has a coding peg and the coupling nut has a coding slot. The centre coupling screw and nut have an hexagonal shoulder which slides in an hexagonal print in the housing, consequently, the coupling screw or nut can take 6 positions. The coding peg on the coupling screw and the slot on the coupling nut can be vertically aligned with an angle or a flat of the hexagonal shoulder. There are two types of coupling screw and coupling nut, those having the coding peg or the slot aligned with a flat and those for which it is aligned with an angle of the hexagonal shoulder. These two types of coupling screw and nut provide a total of 12 polarizing positions. The size 4 male connector can have two centre coupling screw or coupling nut in order to be mated with two size 2 disconnect female connectors. 4.7 Dust caps See EN 4644-002. 4.8 Materials and surface treatment 4.8.1 General When dissimilar metals are in close contact, adequate protection against corrosion shall be used in order to make sure that the electromotive force of the cell shall not exceed 0,25 V. 4.8.2 Housings The material of the housing shall be aluminium alloy or composite. When aluminium is used, it shall be protected with nickel plating or aluminium chromatation (see EN 4644-002). Composite housings are nickel plated. SIST EN 4644-001:2012
Inserts with two polarizing ribs. Inserts with one polarizing rib shall fit the cavities of housing size 1, 3, 4 and cavity A of housing size 2. Inserts with two polarizing ribs shall fit the cavity B of housing size 2. The inserts shall be rear removable from the housing and shall be mechanically retained in the housing. The removal of an insert shall be done by using the tool described in product standard (see EN 4644-002). An insert is installed in the housing by hand, it is a rear snap in insert. The mating face of the insert shall ensure that sealing is provided when connectors are mated together. The interfacial seal shall be on the insert having male contacts and shall not be removable. The rear grommet shall permit sealing for all cable diameters indicated in EN 4644-002 and shall not be removable. For size 5 and height contacts, the insert contact cavity and the grommet shall accept the sealing boots described in EN 4530-002. The mechanical contact retention system shall be integrated in the rigid part of the insert. SIST EN 4644-001:2012
Figure 9 — Mating dimensions SIST EN 4644-001:2012
Key 1 A keying Figure 10 — Female housing SIST EN 4644-001:2012
Key 1 A keying Figure 11 — Male housing SIST EN 4644-001:2012
Figure 12 — Mating dimensions SIST EN 4644-001:2012
Key 1 A keying 2 B keying Figure 13 — Male housing
Key 1 A keying 2 B keying Figure 14 — Female housing
Figure 15 — Mating dimensions SIST EN 4644-001:2012
Key 1
Dimension when not under stress 2
Minimum spring compression force: 150 N. per axis 3
A keying Figure 16
Key 1 A keying
Figure 17 SIST EN 4644-001:2012
Figure 18 SIST EN 4644-001:2012
Key 1 A keying 2 B keying Figure 19a
Key 1 A keying 2 B keying Figure 20a
Key 1 A keying 2 B keying Figure 20b SIST EN 4644-001:2012
Key 1 A keying 2 Indexing point For others dimension on the locking device, see Figure 19a. Figure 21
Panel mounting faces Figure 22 — Mating dimensions SIST EN 4644-001:2012
Key 1 A keying Figure 23 — Male housing SIST EN 4644-001:2012
Key 1 A keying Figure 24 — Female housing SIST EN 4644-001:2012
Key 1 A keying Figure 26 — Male housing SIST EN 4644-001:2012
Key 1 A keying Figure 27 — Female housing SIST EN 4644-001:2012
Key 1 Vertical reference axis of connector (Br or Bp) 2 Insert longitudinal axis (Cr or Cp) 3 Blind hole optional 4 Self-locking thread 4-40 UNC 5 Radius 3,60 max. optional Figure 28 SIST EN 4644-001:2012
Key 1 Vertical reference axis of connector (Br or Bp) 2 Horizontal reference axis of connector (Cr or Cp) 3 Optional shape Figure 29 SIST EN 4644-001:2012
Key 1 Vertical reference axis of connector (Br) 2 Horizontal reference axis of connector (Cr) 3 Vertical axis of shell cavity 4 Optional shape 5 4-40 UNC 2B self-locking thread. Depth = 4,50 mm min. Figure 30 SIST EN 4644-001:2012
Key
1 Vertical reference axis of connector (Br) 2 Horizontal reference axis of connector (Cr) 3 Vertical axis of shell cavity 4 Optional shape 5 4-40 UNC 2B self locking thread. Depth = 4,50 mm min. Figure 31 SIST EN 4644-001:2012
2 M39029/1-101 extremity to male connector bottoming face 3 Insert longitudinal axis 4 Horizontal axis of connector 5 Housing and insert vertical axis Figure 32 SIST EN 4644-001:2012
Key 1 Dimension applicable to male housing 2 Dimension applicable to female housing 3 Horizontal axis of connector 4 Vertical axis of housing cavities 5 Vertical axis of connector Figure 33 SIST EN 4644-001:2012
Key 1 Contact extremity 2 Dimension when insert is butting in rear position 3 Female contact cavity position 4 Male contact cavity position
Figure 34 SIST EN 4644-001:2012
Figure 35 SIST EN 4644-001:2012
6.5.1.3 Gap of inserts in housing cavity See Figure 36 and Figure 37.
Key 1 Area containing the insert symmetry axis (on ribs) Figure 36 — Gap along X axis SIST EN 4644-001:2012
Key 1 Area containing the insert symmetry axis (on ribs) Figure 37 — Gap along the Y axis SIST EN 4644-001:2012
Figure 38 Table 4 Contact size Ø C
Ø D min. max. min. max. 22 2,00 2,10 1,02 1,06 20 2,45 2,55 1,27 1,31 16 3,20 3,30 1,97 2,03 12 3,75 3,85 2,77 2,83 8 7,29 7,39 5,77 5,81 5 7,00 7,10 5,85 5,96
Key 1 Interfacial seal 2 Male contact Figure 39a SIST EN 4644-001:2012
6.5.1.4.3 Size 8 and 5 rear male cavity See Figure 39b.
Size 8 cavity rear diameter
Size 5 cavity rear diameter Figure 39b SIST EN 4644-001:2012
6.7 Contact arrangements Contact arrangements in the insert are specified by Figure 40 to Figure 60 which show the mating face of the inserts for pin contacts. The true positioning for contact cavities is defined in Table 7. Identification of the contact position shall be permanently marked in contrasting colour on the mating face of the insert (optional on interfacial seal) and on the rear face of the wire sealing grommet, identification shall not be recessed or raised on the sealing surfaces. Table 7 Contact size Contact position 22
Ø 0,23PXY 20
Ø 0,23PXY 16
Ø 0,23PXY 12
Ø 0,23PXY 8
Ø 0,27PXY 5
Ø 0,27PXY
Key 1 One or two polarization ribs 2 Centre line Figure 40 Table 8 Dimensions in millimetres Contact position Y X − 11,43 − 8,89 − 6,35 3,81 − 1,27 + 1,27 + 3,81 + 6,35 + 8,89 + 11,43+ 3,81 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 + 1,27 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 − 1,27 C10 C9 C8 C7 C6 C5 C4 C3 C2 C1 − 3,81 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1
Table 9 Contacts Size Quantity Location 22 40 A1 to D10
Key 1 One or two polarization ribs 2 Centre line Figure 41
Table 10 Dimensions in millimetres Contact position Y X -11,43 -10,16 -8.,89 -7,62 -6,35 -5,08 -3,81-2,54-1,270 +1,27+2,54+3,81+5,08 +6,35 +7,62 +8,89+10,16+11,43+4.2 A10 – A9 – A8 – A7 – A6 – A5 – A4 – A3 – A2 – A1 +2.1 – B9 – B8 – B7 – B6 – B5 – B4 – B3 – B2 – B1 – 0 C10 – C9 – C8 – C7 – C6 – C5 – C4 – C3 – C2 – C1 -2.1 – D9 – D8 – D7 – D6 – D5 – D4 – D3 – D2 – D1 – -4.2 E10 – E9 – E8 – E7 – E6 – E5 – E4 – E3 – E2 – E1
Table 11 Contacts Size Quantity Location 22 48 A1 to E10
Key 1 One or two polarization ribs 2 Centre line Figure 42
Table 12 Dimensions in millimetres Contact position Y X
-11,6 -10,15 -8,70 -7,25 -5,80 -4,35 -2,90-1,450 +1,45+2,90+4,35+5,80+7,25 +8,70 +10,15+11,60+3,67 – 8 – 7 – 6 – 5 – 4 – 3 – 2 – 1 – +1,225 17 – 16 – 15 – 14 – 13 – 12 – 11 – 10 – 9 -1,225 – 25 – 24 – 23 – 22 – 21 – 20 – 19 – 18 – -3,68 34 – 33 – 32 – 31 – 30 – 29 – 28 – 27 – 26
Table 13 Contacts Size Quantity Location 22 18 9 to 17, 26 to 34 20 16 1 to 8, 18 to 25
Key 1 One or two polarization ribs 2 Centre line Figure 43 Table 14 Dimensions in millimetres Contact position Y X − 11,20 − 9,60 − 8,00 − 6,40 − 4,80− 3,20− 1,600 + 1,60+ 3,20+ 4,80 + 6,40 + 8,00 + 9,60+ 11,20+ 3,67 – 7 – 6 – 5 – 4 – 3 – 2 – 1 – + 1,225 15 – 14 – 13 – 12 – 11 – 10 – 9 – 8 − 1,225 – 22 – 21 – 20 – 19 – 18 – 17 – 16 – − 3,68 30 – 29 – 28 – 27 – 26 – 25 – 24 – 23
Table 15 Contacts Size Quantity Location 20 30 1 to 30
Key 1 One or two polarization ribs 2 Centre line Figure 44 Table 16 Dimensions in millimetres Contact position Y X − 11,43 − 8,89 − 6,35 − 3,81 − 1,27 + 1,27 + 8,00 + 3,81 6 5 4 3 2 1 – + 1,27 12 11 10 9 8 7 – 0 – – – – – – 25 − 1,27 18 17 16 15 14 13 – − 3,81 24 23 22 21 20 19 –
Table 17 Contacts Size Quantity Location 22 24 1 to 24 8 quadrax (not power) 1 25 SIST EN 4644-001:2012
Key 1 One or two polarization ribs 2 Centre line Figure 45 Table 18 Dimensions in millimetres Contact position Y X − 11,43 − 8,89 − 6,35 − 3,81 − 1,27 + 1,27 + 8,00 + 3,81 7 6 5 4 3 2 – + 1,27 13 12 11 10 9 8 − 0 – – – – – – 1 − 1,27 19 18 17 16 15 14 − − 3,81 25 24 23 22 21 20 −
Table 19 Contacts Size Quantity Location 22 24 2 to 25 8 power 1 1 SIST EN 4644-001:2012
Key 1 One or two polarization ribs 2 Centre line Figure 46 Table 20 Dimensions in millimetres Contact position Y X − 11,43 − 10,20 − 7,45 − 6,35 − 3,81 − 1,27 + 1,27 + 3,81 + 6,35 + 7,45 + 10,20 + 11,43+ 3,81 – – – 6 5 4 3 2 1 – – – + 3,30 – D – – – – – – – – A – + 1,27 – – – – 10 9 8 7 – – – – 0 22 – E – – – – – – B – 21 − 1,27 – – – – 14 13 12 11 – – – – + 3,30 – F – – – – – – – – C – + 3,81 – – – 20 19 18 17 16 15 – – – Table 21 Contacts Size Quantity Location 22 22 1 to 22 16 6 A to F
Key 1 One or two polarization ribs 2 Centre line Figure 47 Table 22 Dimensions in millimetres Contact position Y X − 11,20 − 10,60 − 8,00 − 6,36 − 4,80 − 2,12− 1,60+ 1,60 + 2,12+ 4,80+ 6,36 + 8,00 + 10,60+ 11,20+ 3,68 8 – 7 – 6 – 5 4 – 3 – 2 – 1 0 – 14 – 13 – 12 – – 11 – 10 – 9 – − 3,68 22 – 21 – 20 – 19 18 – 17 – 16 – 15
Table 23 Contacts Size Quantity Location 20 16 1 to 8, 15 to 22 16 6 9 to 14
Key 1 One or two polarization ribs 2 Centre line Figure 48 Table 24 Dimensions in millimetres Contact position Y X − 11,20 − 10,60 − 8,00 − 6,36 − 4,80 − 2,12− 1,60+ 1,60 + 2,12 + 4,80 + 6,36 + 8,00 + 10,60 + 11,20+ 3,30 – 6 – 5 – 4 – – 3 – 2 – 1 – − 0,48 14 – 13 – 12 – 11 10 – 9 – 8 – 7 − 3,68 22 – 21 – 20 – 19 18 – 17 – 16 – 15
Table 25 Contacts Size Quantity Location 20 16 7 to 22 16 6 1 to 6
Key 1 One or two polarization ribs 2 Centre line Figure 49 Table 26 Dimensions in millimetres Contact position Y X − 11,20 − 9,60 − 8,00 −6,40 − 4,80 − 3,20 − 1,60 0 + 1,60 + 3,2 + 8,00 + 3,675 – 5 – 4 – 3 – 2 – 1 – + 1,225 10 – 9 – 8 – 7 – 6 – – 0 – – – – – – – – – – 20 − 1,225 – 14 – 13 – 12 – 11 – – – − 3,675 19 – 18 – 17 – 16 – 15 – –
Table 27 Contacts Size Quantity Location 20 19 1 to 19 5 all except power 1 20
Key 1 One or two polarization ribs 2 Centre line Figure 50 Table 28 Dimensions in millimetres Contact position Y X − 11,20 − 9,60 − 8,00 − 6,40 − 4,80 − 3,20 − 1,60 0 + 1,60 + 3,2 + 8,00 + 3,675 – 6 – 5 – 4 – 3 – 2 – + 1,225 11 – 10 – 9 – 8 – 7 – – 0 – – – – – – – – – – 1 − 1,225 – 15 – 14 – 13 – 12 – – – − 3,675 20 – 19 – 18 – 17 – 16 – –
Table 29 Contacts Size Quantity Location 20 19 1 to 20 5 power 1 1
Key 1 One or two polarization ribs 2 Centre line Figure 51 Table 30 Dimensions in millimetres Contact position Y X − 11,20 − 9,85 − 8,00− 6,40 − 4,80 − 3,20− 1,600 + 1,60+ 3,20+ 4,80 + 6,40 + 8,00 + 9,85+ 11,20+ 3,67 – – − − 4 − 3 − 2 − 1 − − − − + 2,30 – 8 − − − − − − − − − − − 5 − + 1,225 – – − − − 7 − − − 6 − − − − − − 1,225 – – − 11 − − − − − − − 9 − − − − 2,50 – – − − − − − 10 − − − − − − − − 3,68 17 – 16 − 15 − − − − − 14 − 13 − 12
Table 31 Contacts Size Quantity Location 20 14 1 to 4, 6,7,9,11 to 14, 15 to 17 12 3 5, 8, 10
Key 1 One or two polarization ribs 2 Centre line Figure 52 Table 32 Dimensions in millimetres Contact position Y X − 10,68 − 8,01 − 5,34 − 2,67 0 + 2,67 + 5,34 + 8,01 + 10,68 + 3,30 5 − 4 − 3 − 2 − 1 0 − 9 − 8 − 7 − 6 − − 3,30 14 − 13 − 12 − 11 − 10
Table 33 Contacts Size Quantity Location 16 14 1 to 14
Key 1 One or two polarization ribs 2 Centre line Figure 53 Table 34 Dimensions in millimetres Contact position Y X − 11,43 − 10,68 − 7,13 − 6,18 − 2,93 0 + 2,93 + 6,18 + 7,13 + 10,68+ 11,43+ 3,62 4 − − – 3 – 2 – – – 1 + 2,00 − − 6 – – – – – 5 – – + 0,60 8 − – – – – – – – – 7 − 1,25 − − – – – A1 – – – – – − 3,30 − 12 − 11 – – – 10 – 9 –
Table 35 Contacts Size Quantity Location 20 6 1, 2, 3, 4, 7, 8 16 4 9, 10, 11, 12 12 2 5, 6 5 (all except power) 1 A1 SIST EN 4644-001:2012
Key 1 One or two polarization ribs 2 Centre line Figure 54 Table 36 Dimensions in millimetres Contact position Y X − 11,43 − 10,68 − 7,13 − 6,18 − 2,93 0 + 2,93 + 6,18 + 7,13 + 10,68 + 11,43+ 3,62 4 – – – 3 – 2 – – – 1 + 2,00 – – 6 – – – – – 5 – – + 0,60 8 – – – – – – – – – 7 − 1,25 – – – – – 13 – – – – – − 3,30 – 12 – 11 – – – 10 – 9 – Table 37 Contacts Size Quantity Location 20 6 1, 2, 3, 4, 7, 8 16 4 9, 10, 11, 12 12 2 5, 6 5 power 1 13 SIST EN 4644-001:2012
Table 39 Contacts Size Quantity Location 20 8 3 to 10 8 quadrax 2 1 and 2
Contact arrangement 06 SIST EN 4644-001:2012
Key 1 One or two polarization ribs 2 Centre line Figure 56 Table 40 Dimensions in millimetres Contact position Y X − 9,50 − 5,70 − 1,90 + 1,90 + 5,70 + 9,50 + 2,50 3 – 2 – 1 – − 2,50 – 6 – 5 – 4
Table 41 Contacts Size Quantity Location 12 6 1 to 6
Table 43 Contacts Size Quantity Location 8 quadrax 3 1 to 3 SIST EN 4644-001:2012
Key 1 One or two polarization ribs 2 Centre line Figure 58 Table 44 Dimensions in millimetres Contact position Y X − 8,50 0 + 8,50 0 C B A
Table 45 Contacts Size Quantity Location 5 all except power 3 A to C
Key 1 One or two polarization ribs 2 Centre line Figure 59 Table 46 Dimensions in millimetres Contact position Y X − 8,50 0 + 8,50 0 3 2 1
Table 47 Contacts Size Quantity Location 5 power 3 1 to 3
Key 1 Center line Figure 60 Table 48 Contacts Size Quantity Location – – –
Wire size Rated test current Max. contact resistance
Contact to contact
A Initial After test
20 7,5 9 11
203 Electrical continuity at microvolt level Applicable to shielded contact. Requirements defined by the standard for contacts specified in EN 4644-002. 204 Discontinuity of contacts in the microsecond range Duration 1µs. Method B. Test time: throughout the duration of tests EN 2591-402, EN 2591-403. Except 10 ns for quadrax contacts. 205 Housing (shell) electrical continuity Measuring points: on the rear of the male housing and a point in the front face of the counterpart female housing flange. a) between mated connectors: Classes A, B, E and F: 2,5 mΩ max. before and after test. Class C: 15 mΩ max. before and after test. b) between shell and grounded contact Measuring point on the outer contact, flush with the insert and on the body shell. Maximum resistance: Classes A, B, E and F: 10 mΩ max. before and after test. Class C: 20 mΩ max. before and after test
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.