EN ISO 10399:2026
(Main)Sensory analysis - Methodology - Duo-trio test (ISO 10399:2026)
- Abstract
This document specifies a procedure for determining whether a perceptible sensory difference or similarity exists between samples of two products. The method is a forced-choice procedure. The method is applicable whether a difference exists in a single sensory attribute or in several attributes.
The method is statistically less efficient than the triangle test (described in ISO 4120) but is easier to perform by the assessors.
The method is applicable even when the nature of the difference is unknown (i.e. it determines neither the size nor the direction of difference between samples, nor is there any indication of the attribute(s) responsible for the difference). The method is applicable only if the products are fairly homogeneous.
The method is effective for:
determining that either:
a perceptible difference results (duo-trio testing for difference); or
a meaningful perceptible difference does not result (duo-trio testing for similarity) when, for example, a change is made in ingredients, processing, packaging, handling or storage;
selecting, training and monitoring assessors.
Two forms of the method are described:
the constant-reference technique, used when one product is familiar to the assessors (e.g. a sample from regular production);
the balanced-reference technique, used when one product is not more familiar than the other.
- Status
- Published
- Publication Date
- 26-May-2026
- Technical Committee
- CEN/BT - BT Technical Board
- Current Stage
- 6060 - Definitive text made available (DAV) - Publishing
- Start Date
- 27-May-2026
- Due Date
- 27-May-2026
- Completion Date
- 27-May-2026
EN ISO 10399:2026 is the CEN adoption of ISO 10399:2026 for sensory analysis. It specifies the duo-trio test, a forced-choice procedure for deciding whether two products are perceptibly different or sufficiently similar, and for selecting, training and monitoring assessors. The document is aimed at sensory analysts, panel leaders, quality staff and product teams who need a repeatable way to compare product changes.
What does EN ISO 10399:2026 specify?
EN ISO 10399:2026 specifies a sensory discrimination method for two products when the question is whether people can perceive a difference or whether the products are similar enough to be used interchangeably. The method works for a single sensory attribute or several at once, but only when the products are fairly homogeneous.
The standard also states the limits of the method. EN ISO 10399:2026 does not identify the size or direction of a difference, and it does not point to the attribute causing the difference. It is described as less statistically efficient than the triangle test in ISO 4120, but easier for assessors to perform.
The document is organized into clauses 1 to 10, followed by two annexes and a bibliography.
| Annex | What it covers |
|---|---|
| Annex A, normative | Tables for statistical analysis, confidence limits and assessor numbers, including exact values and R code examples |
| Annex B, informative | Worked examples for difference and similarity testing, with worksheet and scoresheet examples |
What are the key requirements of EN ISO 10399:2026?
Test design and principle
EN ISO 10399:2026 uses a triad of three samples: one labelled reference and two coded samples, one of which is the same product as the reference and one of which is the other product. Assessors are told that one coded sample matches the reference and one does not, then they choose either the same sample or the different sample. This matters because the method is forced-choice, so the panel does not have a "no difference" option.
Clause 4 says the presentation order of the coded samples shall be assigned using balanced random schemes, and the number of correct responses is then judged statistically. In practice, this means the test is not based on opinion scores or liking scores, but on counted correct answers.
Test conditions and sample handling
Clause 5 requires the test objective to be stated in writing and the evaluation to be carried out so assessors cannot communicate until all evaluations are complete. EN ISO 10399:2026 points to ISO 8589 for the design of test rooms, which matters because uncontrolled surroundings can affect sensory judgments.
Samples shall be prepared out of sight of assessors and in an identical manner, using the same apparatus, vessels and quantity. The samples should also be presented under the conditions in which the product is normally used, with identical serving conditions and identical size, quantity or volume within each triad. These rules matter because the test is meant to isolate product differences, not differences in presentation.
The code system also matters. Clause 5 calls for uniform random codes, preferably three-digit numbers, and requires that assessors cannot identify the samples from the way they are presented. Retasting, swallowing instructions and the use of neutralizing agents are allowed only when suitable for the product and objective, and assessors shall be instructed accordingly.
Assessors and panel size
Clause 6 says assessors should have the same level of qualification and training, chosen according to the test objective. They also need to be familiar with the mechanics of the duo-trio format. The standard notes that experience and product familiarity can change performance, so monitoring over time can be useful.
EN ISO 10399:2026 ties the number of assessors to the sensitivity required for the test. Clause 6.2 and Annex A show how the panel size depends on the chosen α-risk, β-risk and the assumed proportion of correct responses or distinguishers. In practice, this helps a team decide whether it needs a small screening panel or a larger confirmatory panel.
Procedure and presentation rules
Clause 7 says to use the constant-reference technique when one product is familiar to the assessors, and the balanced-reference technique when neither product is more familiar. The constant-reference technique uses two sequences, while the balanced-reference technique uses four sequences to balance which product acts as reference.
The clause also requires simultaneous presentation of the three samples if possible, a fixed spatial arrangement, and evaluation of the reference first, then the coded samples in the order presented. Assessors are instructed to say which coded sample matches the reference or which one is different, depending on the chosen task wording. This is important because the standard warns that mixing "same" and "different" wording across methods can confuse assessors.
Clause 7 also forbids follow-up questions about preference or acceptance after the choice has been made. If an assessor detects no difference, the standard still requires a random choice and a note that it was a guess.
Analysis, similarity and significance
Clause 8 separates the analysis for difference testing and similarity testing. For difference, EN ISO 10399:2026 uses Annex A Table A.1, and a result is significant when the number of correct responses reaches or exceeds the table value for the chosen α-risk. For similarity, Table A.2 is used, and similarity is concluded when the number of correct responses is at or below the table value for the chosen α-risk and selected p or δ limit.
The standard is careful about the meaning of "similar". In this document, similar means sufficiently alike to be used interchangeably, not identical. That distinction matters in practice because similarity testing is about whether any difference is small enough to be considered not meaningful for the project.
Annex A also provides sample-size guidance in Table A.3 and notes on confidence intervals and software-based calculations. The tables support exact binomial decisions, while the text also allows appropriate statistical software or app-based analysis.
What terms does EN ISO 10399:2026 define?
- Alpha-risk (α-risk) - The probability of concluding that a difference or similarity exists when the statistical decision is actually wrong.
- Beta-risk (β-risk) - The probability of missing a real effect, with 1 - β described as the power of the test.
- Difference - A situation where the samples can be distinguished by their sensory properties.
- Similarity - A situation where any perceptible differences are small enough that the products can be used interchangeably.
- Thurstonian δ - A measure of the magnitude of the sensory difference between two products; the document notes that an estimated value is denoted d-prime.
- Triad - The set of three samples given to an assessor in the duo-trio test.
- Product - The material being evaluated.
- Sample - The prepared unit of product presented and assessed in the test.
Who uses EN ISO 10399:2026?
EN ISO 10399:2026 is used by sensory analysts, panel leaders, quality managers and product developers who need to compare two product variants. It is particularly relevant when a change is made in ingredients, processing, packaging, handling or storage and the team needs to know whether people can perceive a difference.
It is also used for selecting, training and monitoring assessors. That makes it useful in laboratories and product development teams that run sensory panels repeatedly and want consistent discrimination testing across projects.
What changed in EN ISO 10399:2026 from the previous edition?
EN ISO 10399:2026 supersedes EN ISO 10399:2018. The document states these changes from the previous edition:
- The scope has been generalized beyond food and beverage applications.
- The treatment of similarity testing has been updated to reflect best practices, with related definitions and descriptions revised.
- Basic information on the Thurstonian model has been added alongside the previously emphasized guessing model.
- The principle has been expanded slightly for clarity.
- Annex A now provides R code as an option for deriving exact results, and Annex B uses that approach in examples.
- The similarity example in Clause B.2 has been updated, and the previous Clause B.3 example has been removed because the confidence-interval approach is now embedded earlier.
- The references have been updated.
Which standards are used with EN ISO 10399:2026?
EN ISO 10399:2026 refers to these standards in its text and supporting material:
- ISO 5492 - Provides the vocabulary used for sensory analysis terms and definitions.
- ISO 8589 - Gives general guidance for the design of test rooms, which supports the test environment requirements.
- ISO 4120 - Identified in the scope as the standard for the triangle test, used here as a point of comparison.
- ISO 6658 - Cited for general sensory methodology, including separate tests for preference, acceptance and degree of difference.
- ISO 8586 - Cited for selection and training of sensory assessors.
What does the EN ISO 10399:2026 document contain?
EN ISO 10399:2026 contains the full method description, from scope and terms through principle, test conditions, assessor requirements, procedure, statistical interpretation, precision and bias, and reporting. It also includes normative tables for decision thresholds and sample-size guidance.
Annex A provides exact binomial tables for difference and similarity testing, plus approximate calculations and software examples. Annex B gives worked examples, including worksheets and scoresheets, to show how the method is applied in practice for both difference and similarity studies.
Relations
- Effective Date
- 15-Nov-2023
- Effective Date
- 21-Oct-2026
- Effective Date
- 21-Oct-2026
- Effective Date
- 12-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

Bureau Veritas
Bureau Veritas is a world leader in laboratory testing, inspection and certification services.

DNV
DNV is an independent assurance and risk management provider.
Sponsored listings
Frequently Asked Questions
EN ISO 10399:2026 is a standard published by the European Committee for Standardization (CEN). Its full title is "Sensory analysis - Methodology - Duo-trio test (ISO 10399:2026)". This standard covers: This document specifies a procedure for determining whether a perceptible sensory difference or similarity exists between samples of two products. The method is a forced-choice procedure. The method is applicable whether a difference exists in a single sensory attribute or in several attributes. The method is statistically less efficient than the triangle test (described in ISO 4120) but is easier to perform by the assessors. The method is applicable even when the nature of the difference is unknown (i.e. it determines neither the size nor the direction of difference between samples, nor is there any indication of the attribute(s) responsible for the difference). The method is applicable only if the products are fairly homogeneous. The method is effective for: determining that either: a perceptible difference results (duo-trio testing for difference); or a meaningful perceptible difference does not result (duo-trio testing for similarity) when, for example, a change is made in ingredients, processing, packaging, handling or storage; selecting, training and monitoring assessors. Two forms of the method are described: the constant-reference technique, used when one product is familiar to the assessors (e.g. a sample from regular production); the balanced-reference technique, used when one product is not more familiar than the other.
This document specifies a procedure for determining whether a perceptible sensory difference or similarity exists between samples of two products. The method is a forced-choice procedure. The method is applicable whether a difference exists in a single sensory attribute or in several attributes. The method is statistically less efficient than the triangle test (described in ISO 4120) but is easier to perform by the assessors. The method is applicable even when the nature of the difference is unknown (i.e. it determines neither the size nor the direction of difference between samples, nor is there any indication of the attribute(s) responsible for the difference). The method is applicable only if the products are fairly homogeneous. The method is effective for: determining that either: a perceptible difference results (duo-trio testing for difference); or a meaningful perceptible difference does not result (duo-trio testing for similarity) when, for example, a change is made in ingredients, processing, packaging, handling or storage; selecting, training and monitoring assessors. Two forms of the method are described: the constant-reference technique, used when one product is familiar to the assessors (e.g. a sample from regular production); the balanced-reference technique, used when one product is not more familiar than the other.
EN ISO 10399:2026 is classified under the following ICS (International Classification for Standards) categories: 67.240 - Sensory analysis. The ICS classification helps identify the subject area and facilitates finding related standards.
EN ISO 10399:2026 has the following relationships with other standards: It is inter standard links to EN ISO 10399:2018, ISO 5492:2008, ISO 8589:2007, ISO 10399:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN ISO 10399:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 alpha-risk
- 3.2 beta-risk
- 3.3 difference
- 3.5 product
- 3.6 sample
- 3.7 sensitivity
- 3.8 similarity
- 3.9 Thurstonian δ
- 3.10 triad
- 4 Principle
- 5 General test conditions and requirements
- 6 Assessors
- 6.1 Qualification
- 6.2 Number of assessors
- 7 Procedure
- 8 Analysis and interpretation of results
- 8.1 When testing for a difference
- 8.2 When testing for similarity
- 9 Precision and bias
- 10 Test report
- Annex A
- Annex B
- Bibliography
1 Scope
This document specifies a procedure for determining whether a perceptible sensory difference or similarity exists between samples of two products. The method is a forced-choice procedure. The method is applicable whether a difference exists in a single sensory attribute or in several attributes. The method is statistically less efficient than the triangle test (described in ISO 4120) but is easier to perform by the assessors.
The method is applicable even when the nature of the difference is unknown (i.e. it determines neither the size nor the direction of difference between samples, nor is there any indication of the attribute(s) responsible for the difference). The method is applicable only if the products are fairly homogeneous. The method is effective for:
a) determining that either:
1) a perceptible difference results (duo-trio testing for difference); or 2) a meaningful perceptible difference does not result (duo-trio testing for similarity) when, for example, a change is made in ingredients, processing, packaging, handling or storage; b) selecting, training and monitoring assessors.
Two forms of the method are described:
- the constant-reference technique, used when one product is familiar to the assessors (e.g. a sample from regular production);
- the balanced-reference technique, used when one product is not more familiar than the other.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 5492, Sensory analysis — Vocabulary ISO 8589, Sensory analysis — General guidance for the design of test rooms
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 5492 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
SIST EN ISO 10399:2026 ISO 10399:2026(en)
3.1 alpha-risk
α-risk Type I error rate significance level false positive rate α probability of rejecting the null hypothesis by a statistical test when, in fact, the null hypothesis is true Note 1 to entry: When testing for product (3.5) differences (3.3), the α-risk is the probability of erroneously concluding that a perceptible difference exists when, in fact, it does not. When testing for similarity (3.8), the α-risk is the probability of erroneously concluding that the products are perceptibly similar when, in fact, they are not.
3.2 beta-risk
β-risk Type II error rate false negative rate β probability of failing to reject the null hypothesis by a statistical test when, in fact, the null hypothesis is not true Note 1 to entry: 1 – β is also known as the power of the test. Note 2 to entry: When testing for product (3.5) differences (3.3), the β-risk is the probability of failing to conclude that a perceptible difference exists when, in fact, the products are perceptually different. When testing for similarity (3.8), the β-risk is the probability of failing to conclude that the products are perceptibly similar when, in fact, they are.
3.3 difference
situation in which samples (3.6) can be distinguished based on their sensory properties 3.4 p d proportion of assessments in which a perceptible difference (3.3) is detected between the two products (3.5)
3.5 product
material to be evaluated
3.6 sample
unit of product (3.5) prepared, presented and evaluated in the test
3.7 sensitivity
< statistic> statistical parameters that measure the performance characteristics of the test Note 1 to entry: In statistical terms, the sensitivity of the test is defined by the values of α, β and p (3.4) (or δ (3.9)). d
3.8 similarity
situation in which any perceptible differences (3.3) between the samples (3.6) are so small that the products (3.5) can be used interchangeably
3.9 Thurstonian δ
δ measure of the magnitude of the sensory difference (3.3) between two products (3.5) Note 1 to entry: The true perceptual difference between two products is denoted δ. The estimate of δ from the data is denoted d′ (“d-prime”).
SIST EN ISO 10399:2026 ISO 10399:2026(en) Note 2 to entry: For a given protocol, any value of δ is equivalent to a value p (3.4) so they can be used interchangeably, d [4][6] but the relationship changes with the test protocol.
3.10 triad
three samples (3.6) given to an assessor in the duo-trio test Note 1 to entry: In the duo-trio test, one sample is labelled as the reference, the other two are marked with different codes. One of the coded samples is the same product (3.5) as the reference; the other coded sample is the other product in the test.
4 Principle
The number of assessors is chosen based on the sensitivity desired for the test (see 6.2 and the discussion in Clause A.3).
Assessors receive a set of three samples (i.e. a triad), one sample of which is labelled as a reference and the other two samples have different codes. The two coded samples comprise one sample that is the same product as the labelled reference sample (i.e. the hidden reference) and one sample that is a different product than the labelled reference sample (i.e. the test sample). The presentation order of the coded samples is assigned to assessors based on balanced random schemes (see 7.1). The assessors are informed that one of the coded samples is the same as the reference and that one is different. Based on their training and the instructions given prior to the test, the assessors report either which of the coded samples they believe to be same as the reference, or which of the coded samples they believe to be different from the reference. The number of correct responses is counted, and the significance is determined by reference to a statistical table or an applicable computer program or app.
5 General test conditions and requirements
5.1 Clearly state the test objective in writing.
5.2 Carry out the test under conditions that prevent communication among assessors until all the evaluations have been completed using facilities and booths that conform with ISO 8589. 5.3 Prepare the samples out of sight of the assessors and in an identical manner (i.e. same apparatus, same vessels, same quantity of product).
5.4 Assessors shall not be able to identify the samples from the way in which they are presented. For example, in a taste test, avoid any differences in appearance. Mask any irrelevant colour differences using light filters and/or subdued illumination.
5.5 Code the test samples in a uniform manner, preferably using three-digit numbers, chosen at random for each test. Each triad is composed of three samples, one labelled as the reference and two labelled with different codes. Preferably, different codes should be used for each assessor during a session. However, the same two codes may be used for all assessors within a test, provided that each code is used only once per assessor during a test session (e.g. if several duo-trio tests on the same or different products are being conducted in the same session).
5.6 The samples should be presented under the conditions at which the product is generally used (e.g. when tasting, present the samples at the temperature at which the product is generally consumed). The serving conditions of the three samples in each triad shall be identical, just as that of all the other samples in a series of tests on a given type of product.
5.7 The size, quantity or volume presented shall be identical for the three samples in each triad, just as that of all the other samples in a series of tests on a given type of product. The size, quantity or volume to be
SIST EN ISO 10399:2026 ISO 10399:2026(en) evaluated may be imposed. If it is not, the assessors should be told to take sizes, quantities or volumes that are always similar whatever the sample.
5.8 Depending on the products and test objectives, re-tasting (of the reference or all samples) may be accepted. The assessors shall be instructed accordingly.
5.9 When tasting, the assessors shall be told whether or not they are to swallow the samples or whether they are free to do as they please. In this latter case, they shall be requested to proceed in the same manner for all samples. Depending on project objectives and test products, suitable neutralizing agents may be used between or even within individual trials. Assessors shall be instructed accordingly. 5.10 During the test sessions, avoid giving information about product identity, expected treatment effects, or individual performance until all testing is completed.
6 Assessors
6.1 Qualification
All assessors should possess the same level of qualification and training; this level should be chosen based on the test objective (see ISO 8586 for guidance). Experience and familiarity with the product can improve the performance of an assessor and, therefore, can increase the likelihood of a correct result, which will then increase the probability of finding a significant difference but would decrease the likelihood to find significant similarity. Monitoring the performance of assessors over time may be useful for increased sensitivity.
All assessors shall be familiar with the mechanics of the duo-trio test (i.e. the format, task and evaluation procedure).
6.2 Number of assessors
Choose the number of assessors so as to obtain the sensitivity required for the test (see the discussion in Clause A.3). Using large numbers of assessors increases the probability of detecting small differences between the products. However, in practice, the number of assessors often is determined by material conditions (e.g. duration of the experiment, number of available assessors, quantity of product). As examples, first consider testing for product differences, in which the null hypothesis assumes p = 0 % d and the desired power is 80 %. If the alternative hypothesis assumes the true p = 30 %, then a test at the d 10 %-significance level requires 53 assessors. A test at the 5 %-significance level for the smaller effect size of p = 25 % requires 102 assessors.
d Next, consider testing for product similarity, in which the alternative hypothesis assumes p = 0 % and the d desired power is 80 %. If similarity is evaluated using the equivalence margin of p = 30 %, i.e. the null d hypothesis assumes p = 30 %, then a test at the 10 %-significance level requires 49 assessors. A test at the d 5 %-significance level using the more conservative equivalence margin p = 25 % requires 102 assessors. d As these examples show, a test for product differences at a specific α-risk, β-risk, and values for p under d the null and alternative hypotheses requires a particular sample size that is nearly the same as, and often identical to, the sample size needed to test for equivalence given these same parameter values, but where the p values under the null and alternative hypotheses have been reversed. d Avoid replicate evaluations by the same assessor whenever possible. However, if replicate evaluations are needed to produce a sufficient number of total evaluations, every effort should be made to have each
SIST EN ISO 10399:2026 ISO 10399:2026(en) assessor perform the same number of replicate evaluations. For example, if only 12 assessors are available, have each assessor evaluate 3 triads to obtain a total of 36 evaluations. NOTE Treating 3 evaluations performed by 12 assessors as 36 independent evaluations is not statistically valid when testing for similarity using Table A.2. However, the test for difference using Table A.1 is statistically valid [7][8] even when replicate evaluations are performed. Recent publications on replicated discrimination tests suggest [5] alternative, model-based approaches for analysing replicated evaluations in discrimination tests, or for analysing [10] replicated evaluations in discrimination tests with the purpose of showing similarity.
7 Procedure
7.1 If the product is familiar to the assessors (e.g. a control sample from the production line), use the constant reference technique (see 7.2). If neither product is more familiar than the other, use the balancedreference technique (see 7.3). 7.2 Constant-reference technique: Prepare worksheets and scoresheets (see Clause B.2) in advance of the test so as to utilize an equal number of the two possible sequences of two products, A and B:
A-REF A B A-REF B A Distribute these at random in groups of two among the assessors (i.e. use each sequence once among the first two assessors; use each sequence once again among the next two assessors, etc.). This will minimize the imbalance that results if the total number of assessors is not an even number. 7.3 Balanced-reference technique: Prepare worksheets and scoresheets (see Clause B.1) in advance of the test so as to utilize an equal number of the four possible sequences of two products, A and B:
A-REF A B A-REF B A B-REF A B B-REF B A where the first two triads contain product A as the reference (i.e. A-REF) and the last two triads contain product B as the reference (i.e. B-REF). Distribute these at random in groups of four among the assessors (i.e. use each sequence once among the first group of four assessors; use each sequence once again among the next group of four assessors, etc.). This will minimize the imbalance that results if the total number of assessors is not a multiple of four.
...