EN 12419:1999
(Main)Respiratory protective devices - Light duty construction compressed air line breathing apparatus incorporating a full face mask, half mask or quarter mask - Requirements, testing, marking
Respiratory protective devices - Light duty construction compressed air line breathing apparatus incorporating a full face mask, half mask or quarter mask - Requirements, testing, marking
This European Standard specifies the minimum requirements for light duty construction compressed air line breathing apparatus incorporating a full face mask, half mask or quarter mask which is intended for use in gaseous, particulate or combined contaminated atmospheres. Such equipment is intended for use in work situations where the risk of damage to the compressed air supply tube is low and where movements of the wearer are limited. Escape and diving apparatus and that used in abrasive blasting conditions are not covered by this European Standard. Laboratory tests and practical performance tests are included for the assessment of compliance with the requirements.
Atemschutzgeräte - Leichtschlauchgeräte mit Vollmaske, Halbmaske oder Viertelmaske für leichte Einsätze - Anforderungen, Prüfung, Kennzeichnung
Diese Europäische Norm legt Mindestanforderungen für Leichtschlauchgeräte mit einer Vollmaske, Halbmaske oder Viertelmaske zum Einsatz in durch Gase, Partikeln oder beides verunreinigten Atmosphären fest.
Appareils de protection respiratoire - Appareils de protection respiratoire isolants à adduction d'air comprimé de construction légère, avec masque complet, demi-masque ou quart de masque - Exigences, essais, marquage
La présente norme européenne spécifie les exigences minimales des appareils de protection respiratoire isolants à adduction d'air comprimé de conception légère, avec masque complet, demi-masque ou quart de masque qui sont destinés à une utilisation en atmosphère contaminée par des gaz, des particules ou les deux.
Oprema za varovanje dihal – Dihalni aparat na stisnjeni zrak za lažja dela z obrazno masko, polobrazno masko ali ustnikom - Zahteve, preskušanje, označevanje
General Information
- Status
- Withdrawn
- Publication Date
- 18-May-1999
- Withdrawal Date
- 19-Apr-2005
- Technical Committee
- CEN/TC 79 - Respiratory protective devices
- Current Stage
- 9960 - Withdrawal effective - Withdrawal
- Start Date
- 20-Apr-2005
- Completion Date
- 20-Apr-2005
Relations
- Effective Date
- 22-Dec-2008
Get Certified
Connect with accredited certification bodies for this standard

NSF International
Global independent organization facilitating standards development and certification.
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Sponsored listings
Frequently Asked Questions
EN 12419:1999 is a standard published by the European Committee for Standardization (CEN). Its full title is "Respiratory protective devices - Light duty construction compressed air line breathing apparatus incorporating a full face mask, half mask or quarter mask - Requirements, testing, marking". This standard covers: This European Standard specifies the minimum requirements for light duty construction compressed air line breathing apparatus incorporating a full face mask, half mask or quarter mask which is intended for use in gaseous, particulate or combined contaminated atmospheres. Such equipment is intended for use in work situations where the risk of damage to the compressed air supply tube is low and where movements of the wearer are limited. Escape and diving apparatus and that used in abrasive blasting conditions are not covered by this European Standard. Laboratory tests and practical performance tests are included for the assessment of compliance with the requirements.
This European Standard specifies the minimum requirements for light duty construction compressed air line breathing apparatus incorporating a full face mask, half mask or quarter mask which is intended for use in gaseous, particulate or combined contaminated atmospheres. Such equipment is intended for use in work situations where the risk of damage to the compressed air supply tube is low and where movements of the wearer are limited. Escape and diving apparatus and that used in abrasive blasting conditions are not covered by this European Standard. Laboratory tests and practical performance tests are included for the assessment of compliance with the requirements.
EN 12419:1999 is classified under the following ICS (International Classification for Standards) categories: 13.340.30 - Respiratory protective devices. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 12419:1999 has the following relationships with other standards: It is inter standard links to EN 14594:2005. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 12419:1999 is associated with the following European legislation: EU Directives/Regulations: 89/686/EEC, 93/95/EEC, 96/58/EC; Standardization Mandates: M/031. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 12419:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.MHR]QDþHYDQMHAtemschutzgeräte - Leichtschlauchgeräte mit Vollmaske, Halbmaske oder Viertelmaske für leichte Einsätze - Anforderungen, Prüfung, KennzeichnungAppareils de protection respiratoire - Appareils de protection respiratoire isolants a adduction d'air comprimé de construction légere, avec masque complet, demi-masque ou quart de masque - Exigences, essais, marquageRespiratory protective devices - Light duty construction compressed air line breathing apparatus incorporating a full face mask, half mask or quarter mask - Requirements, testing, marking13.340.30Varovalne dihalne napraveRespiratory protective devicesICS:Ta slovenski standard je istoveten z:EN 12419:1999SIST EN 12419:2000en01-februar-2000SIST EN 12419:2000SLOVENSKI
STANDARD
SIST EN
...




Questions, Comments and Discussion