Aerospace series - Arc Fault Circuit breakers, three-pole, temperature compensated, rated currents 3 A to 25 A, 115/200 V a.c. 400 Hz constant frequency - Part 003: Without auxiliary contacts - Product standard

This European Standard specifies the required characteristics for three-pole, arc fault circuit breakers,
rated currents from 3 A to 25 A, switching capacity 65 In, for use in aircraft electrical systems. Their
operating temperatures are between − 40 °C to 85 °C at a maximum altitude of Z = 15 000 m. The thermal
protection is temperature compensated and operates between − 55 °C and 125 °C.
These arc fault circuit breakers are operated by a push-pull type single pushbutton (actuator), with
delayed action "trip-free" tripping.
They will continue to function up to the short-circuit current.

Luft- und Raumfahrt - Störlichtbogen-Schutzschalter, dreipolig, temperaturkompensiert, Nennströme von 3 A bis 25 A - 115/200 V Wechselstrom, 400 Hz Konstantfrequenz - Teil 003: Ohne Zusatzkontakte - Produktnorm

Série aérospatiale - Disjoncteurs tripolaires à détection d’arc, compensés en température, intensités nominales 3 A á 25 A, 115/200 V c.a. 400 Hz fréquence fixe - Partie 003 : Sans contacts auxiliaires - Norme de produit

Aeronavtika - Obločni dušilni odklopniki, tripolni, temperaturno kompenzirani, za naznačene toke od 3 A do 25 A, 115/200 V izmenična napetost, 400 Hz konstantna frekvenca - 003. del: Brez pomožnih kontaktov - Standard za proizvod

Ta evropski standard določa potrebne lastnosti obločnih dušilnih odklopnikov, tripolnih, temperaturno kompenziranih, za naznačene toke od 3 A do 25 A, s preklopno zmogljivostjo 65 In, za uporabo v letalskih električnih sistemih. Njihove obratovalne temperature so od 40 °C do 85 °C pri največji višini Z = 15.000 m. Toplotna zaščita je temperaturno kompenzirana in obratuje pri temperaturah od  55 °C do 125 °C.
Ti obločni dušilni odklopniki se upravljajo z enim gumbom (sprožilom) vrste potisni-povleci, z zakasnjenim proženjem brez sprožila.
Delovali bodo do kratkega stika.

General Information

Status
Published
Publication Date
09-Oct-2018
Withdrawal Date
29-Apr-2019
Technical Committee
ASD-STAN - Aerospace
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
10-Oct-2018
Completion Date
10-Oct-2018

Overview

EN 4839-003:2018 is a European product standard in the Aerospace series that specifies required characteristics for three‑pole, temperature‑compensated arc fault circuit breakers (AFCBs) for aircraft electrical systems. Part 003 covers versions without auxiliary contacts, rated for 3 A to 25 A, at 115/200 V a.c., 400 Hz constant frequency. It defines mechanical, electrical and environmental requirements, dimensional constraints, marking, delivery and test references to ensure safe, interchangeable AFCB components for aviation use.

Key Topics and Technical Requirements

  • Scope & operating conditions
    • Rated currents: 3 A – 25 A
    • Nominal voltage: 115/200 V a.c., 400 Hz (three‑phase)
    • Operating ambient: −40 °C to +85 °C; thermal protection calibrated −55 °C to +125 °C
    • Maximum altitude: 15 000 m
  • Protection & operation
    • Arc fault detection capability and temperature‑compensated thermal protection
    • Push‑pull single pushbutton actuator with delayed action “trip‑free” tripping
    • Switching capacity: 65 × In
    • Continues to operate up to short‑circuit currents
  • Mechanical & installation
    • Maximum mass: 170 g (including mounting hardware)
    • Panel cut‑out and mounting per TR 6083C202; metallic front plate provides neutral connection
    • Recommended torques: attachment nut (4.0 ± 0.25) N·m; connection hardware (1.6 ± 0.1) N·m
  • Environmental & mechanical qualification
    • Vibration and shock resistance (sinusoidal, random and low‑frequency levels specified; shock 50 g‑PK)
    • Corrosion, humidity and contaminant resistance referenced to EN 4839‑001
  • Electrical performance & testing
    • Voltage drop and tripping thresholds specified by rating
    • Overload and short‑circuit performance with defined test sequences and altitudes
    • Endurance: 5 000 no‑load and 2 500 load operations
    • Dielectric strength and insulation resistance limits
  • Identification & delivery
    • Marking requirements: part number, date code, manufacturer ID, electrical diagram, terminal IDs
    • Rated current codes (e.g., 03A, 05A, 10A, 25A) and delivery hardware kits per EN 6113

Applications and Who Uses This Standard

  • Aircraft electrical distribution and protection designers specifying AFCBs for fixed‑wing and rotorcraft installations
  • Avionics and aircraft systems engineers responsible for component selection, integration and panel layout
  • Aerospace component manufacturers and suppliers developing or qualifying AFCBs without auxiliary contacts
  • Certification, maintenance and procurement teams ensuring components meet interoperability, environmental and safety criteria

Related Standards

  • EN 4839‑001 (Technical specification for same series)
  • EN 3841‑100 / EN 3841‑305 (Circuit breaker test methods)
  • EN 6113 (Connecting and attachment hardware)
  • TR 6083 (Panel cut‑out / installation)
  • FED‑STD‑595B (colour references)

Keywords: arc fault circuit breaker, AFCB, aerospace series, EN 4839‑003:2018, three‑pole, temperature compensated, 115/200 V AC 400 Hz, aircraft circuit protection.

Frequently Asked Questions

EN 4839-003:2018 is a standard published by the European Committee for Standardization (CEN). Its full title is "Aerospace series - Arc Fault Circuit breakers, three-pole, temperature compensated, rated currents 3 A to 25 A, 115/200 V a.c. 400 Hz constant frequency - Part 003: Without auxiliary contacts - Product standard". This standard covers: This European Standard specifies the required characteristics for three-pole, arc fault circuit breakers, rated currents from 3 A to 25 A, switching capacity 65 In, for use in aircraft electrical systems. Their operating temperatures are between − 40 °C to 85 °C at a maximum altitude of Z = 15 000 m. The thermal protection is temperature compensated and operates between − 55 °C and 125 °C. These arc fault circuit breakers are operated by a push-pull type single pushbutton (actuator), with delayed action "trip-free" tripping. They will continue to function up to the short-circuit current.

This European Standard specifies the required characteristics for three-pole, arc fault circuit breakers, rated currents from 3 A to 25 A, switching capacity 65 In, for use in aircraft electrical systems. Their operating temperatures are between − 40 °C to 85 °C at a maximum altitude of Z = 15 000 m. The thermal protection is temperature compensated and operates between − 55 °C and 125 °C. These arc fault circuit breakers are operated by a push-pull type single pushbutton (actuator), with delayed action "trip-free" tripping. They will continue to function up to the short-circuit current.

EN 4839-003:2018 is classified under the following ICS (International Classification for Standards) categories: 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.

You can purchase EN 4839-003:2018 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.YRGLuft- und Raumfahrt - Schutzschalter, lichtbogen (überschlags)sensitiv, dreipolig, temperaturkompensiert, Nennströme von 3 A bis 25 A, 115/200 V a.c. 400 Hz Konstantfrequenz - Teil 003: Ohne Signalkontakt - ProduktnormSérie aérospatiale - Disjoncteurs tripolaires à détection d’arc, compensés en température, intensités nominales 3 A á 25 A, 115/200 V c.a. 400 Hz fréquence fixe - Partie 003 : Sans contacts auxiliaires - Norme de produitAerospace series - Arc Fault Circuit breakers, three-pole, temperature compensated, rated currents 3 A to 25 A, 115/200 V a.c. 400 Hz constant frequency - Part 003: Without auxiliary contacts - Product standard49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 4839-003:2018SIST EN 4839-003:2018en,fr,de01-december-2018SIST EN 4839-003:2018SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 4839-003
October
t r s z ICS
v {ä r x r English Version
Aerospace series æ Arc Fault Circuit breakersá threeæpoleá temperature compensatedá rated currents
u A to
t w Aá Without auxiliary contacts æ Product standard Série aérospatiale æ Disjoncteurs tripolaires à détection d 5arcá compensés en températureá intensités nominales Partie
r r u ã Sans contacts auxiliaires æ Norme de produit
Luftæ und Raumfahrt æ Schutzschalterá lichtbogen temperaturkompensiertá Nennströme von
u A bis
t w Aá Ohne Signalkontakt æ Produktnorm This European Standard was approved by CEN on
z February
t r s zä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Rue de la Science 23,
B-1040 Brussels
t r s z CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
v z u {æ r r uã t r s z ESIST EN 4839-003:2018

EN 3841-100, Aerospace series — Circuit breakers — Test Methods — Part 100: General EN 3841-305, Aerospace series — Circuit breakers — Test Methods — Part 305: Short-circuit performance EN 4839-001, Aerospace series — Arc fault circuit breakers, three-pole, temperature compensated, rated current from 3 A to 25 A, 115 V a.c. 400 Hz constant frequency — Part 001: Technical specification EN 6113, Aerospace series — Circuit breaker, connecting and attachment hardware TR 6083, Aerospace series — Cut-outs f
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...