Textiles - Tests for colour fastness - Part A06: Instrumental determination of 1/1 standard depth of colour (ISO 105-A06:1995)

Intended for the determination of the 1/1 standard depth of a dyeing on any textile material by a colorimetric method which is a permitted alternative to the visual method described in clause 12 of ISO 105-A01:1994.

Textilien - Farbechtheitsprüfungen - Teil A06: Farbmetrische Bestimmung der 1/1 Richttyptiefe (ISO 105-A06:1995)

Textiles - Essais de solidité des teintures - Partie A06: Méthode instrumentale pour la détermination de la profondeur de nuance standard 1/1 (ISO 105-A06:1995)

La présente méthode est destinée à déterminer la profondeur de teinte standard 1/1 d'une teinture sur un matériaux textile à l'aide d'une méthode colorimétrique comme alternative permise à la méthode visuelle décrite dans l'article 12 de l'ISO 105-A01:1994. Cette méthode n'est applicable qu'à profondeur de teinte standard 1/1 des teintures. Son utilisation pour d'autres profondeurs de teinte est actuellement à l'étude.  
NOTE -- Les éprouvettes pour lesquelles cette méthode colorimétrique indique une profondeur de teinte standard 1/1 peuvent différer des éprouvettes qui montrent une profondeur de teinte standard 1/1 après un examen visuel par comparaison avec des étalons physiques. Ces variations peuvent conduire à des résultats différents dans les essais ultérieurs. Il est recommandé que la méthode d'évaluation de la profondeur de teinte standard 1/1, c'est-à-dire selon l'ISO 105-A06 ou visuellement, figure dans le rapport des essais effectués ultérieurement.

Tekstilije - Preskušanje barvne obstojnosti - Del A06: Instrumentalno ugotavljanje globine obarvanja 1/1 standarda (ISO 105-A06:1995)

General Information

Status
Published
Publication Date
22-Apr-1997
Withdrawal Date
30-Oct-1997
Current Stage
9093 - Decision to confirm - Review Enquiry
Start Date
29-May-2007
Completion Date
29-May-2007

Buy Standard

Standard
EN ISO 105-A06:1999
English language
6 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-marec-1999
Tekstilije - Preskušanje barvne obstojnosti - Del A06: Instrumentalno ugotavljanje
globine obarvanja 1/1 standarda (ISO 105-A06:1995)
Textiles - Tests for colour fastness - Part A06: Instrumental determination of 1/1 standard
depth of colour (ISO 105-A06:1995)
Textilien - Farbechtheitsprüfungen - Teil A06: Farbmetrische Bestimmung der 1/1
Richttyptiefe (ISO 105-A06:1995)
Textiles - Essais de solidité des teintures - Partie A06: Méthode instrumentale pour la
détermination de la profondeur de nuance standard 1/1 (ISO 105-A06:1995)
Ta slovenski standard je istoveten z: EN ISO 105-A06:1997
ICS:
59.080.01 Tekstilije na splošno Textiles in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

INTERNATIONAL ISO
STANDARD 105-AO6
First edition
1995-12-01

Textiles - Tests for colour fastness -
Part A06:
Instrumental determination of l/l Standard
depth of colour
Textiles - Essais de solidite des teintures -
Partie A06: Methode instrumentale pour Ia dktermination de Ia profondeur
de nuance Standard 7/7
Reference number
ISO 105-A06: 1995(E)
ISO 105-A06:1995(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide
federation of national Standards bodies (ISO member bodies). The work
of preparing International Standards is normally carried out through ISO
technical committees. Esch member body interested in a subject for
which a technical committee has been established has the right to be
represented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work. ISO
collaborates closely with the International Electrotechnical Commission
(1 EC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are
circulated to the member bodies for voting. Publication as an International
Standard requires approval by at least 75 % of the member bodies casting
a vote.
International Standard ISO 105-AO6 was prepared by Technical Committee
lSO/TC 38, Textiles, Subcommittee SC 1, Tests for coloured textiles and
coloran ts.
ISO 105 was previously published in thirteen “parts ”, each designated by
a letter (e.g. “Part A ”), with publication dates between 1978 and 1985.
Esch part contained a series of “sections ”, each designated by the re-
spective part Ietter and by a two-digit serial number (e.g. “Section AO1 “).
These sections are now being republished as separate documents, them-
selves designated “Parts” but retaining their earlier alphanumeric desig-
nations. A complete list of these Parts is given in ISO 105-AOI .
Annexes A and B of this part of ISO 105 are for information only.
0 ISO 1995
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any means, electronie or mechanical, including photocopying and
microfilm, without Permission in writing from the publisher.
International Organization for Standardization
Case Postale 56 l CH-1 21 1 Geneve 20 l Swi tzerland
Printed in Switzerland
ISO 1050A06:1995(E)
INTERNATIONAL STANDARD 0 ISO
- Tests for colour fastness -
Textiles
Part A06:
Instrumental determination of l/l Standard depth of colour
3 Principle
1 Scope
The CIELAB colour coordinates L* (lightness), C ‘,,
This method is intended for determining l/l Standard
depth of a dyeing on any textile material by a color- (chroma) and h,, (hue) of the dyeing to be checked for
imetric method as a permitted alternative to the visual l/l Standard depth are measured instrumentally. The
lightness Lsn for 1/1 Standard depth is calculated by
method described in clause 12 of ISO 105-AOl:l994.
means of a given equation. The lightness differente
This method is applicable to l/l Standard depth of
AL between the measured lightness L* of the dyeing
colour only. Its use for other Standard depths is under
and the calculated lightness & required for l/l
consideration.
Standard depth is determined to decide if the dyeing
represents 1 /l Standard depth.
NOTE 1 Spetimens which this colorimetric method indi-
cate to be of 1 /l Standard depth may differ from specimens
which are visually assessed to be of 1 /l Standard depth by
4 Apparatus
comparison with physical Standards known to be of l/l
Standard depth. These differentes may lead to differentes
4.1 Spectrophotometer or colorimeter, meeting
in the results of tests applied su
...

Questions, Comments and Discussion