Power operated pedestrian swing door drives with self closing function - Requirements and test methods

This document is applicable to power-operated pedestrian swing door drives with self closing function using mechanically stored energy for single and double leaf swing doorsets with or without fire resistance and smoke control characteristics. It defines requirements and test methods for the self-closing function.
This document does not apply to:
- electrically controlled hold-open systems according to EN 14637;
- door coordinating devices according to EN 1158;
- electrically powered hold-open devices for swing doors according to EN 1155.
Requirements and test methods for hold-open systems are not part of this document.
Additional requirements and test methods for the use of power-operated pedestrian swing door drives with self closing function on double-leaf swing doors are described in EN 1158 and are therefore not part of this document.

Kraftbetätigte Drehflügeltürantriebe mit Selbstschließfunktion - Anforderungen und Prüfverfahren

Dieses Dokument gilt für kraftbetätigte Drehflügeltürantriebe mit Selbstschließfunktion mit mechanisch gespeicherter Energie für ein  und zweiflügelige Drehflügeltüren mit oder ohne Feuer  und Rauchschutz¬eigenschaften. Es legt Anforderungen und Prüfverfahren für die Selbstschließfunktion fest.
Dieses Dokument gilt nicht für:
- elektrisch gesteuerte Feststellanlagen nach EN 14637;
- Schließfolgeregler nach EN 1158;
- elektrisch betriebene Feststellvorrichtungen für Drehflügeltüren nach EN 1155.
Anforderungen und Prüfverfahren für Feststellanlagen sind nicht Teil dieses Dokuments.
Zusätzliche Anforderungen und Prüfverfahren für die Verwendung von kraftbetätigten Drehflügeltür-antrieben mit Selbstschließfunktion bei zweiflügeligen Drehflügeltüren werden in EN 1158 beschrieben und sind daher nicht Teil dieses Dokuments.

Opérateurs motorisés de portes battantes pour piétons avec fonction de fermeture automatique - Exigences et méthodes d’essai

Le présent document s’applique aux opérateurs motorisés de portes battantes pour piétons avec fonction de fermeture automatique utilisant de l’énergie mécanique intrinsèque, pour portes battantes à un et deux vantaux, avec ou sans caractéristiques de résistance au feu et d’étanchéité à la fumée. Le présent document définit les exigences et les méthodes d'essai pour la fonction de fermeture automatique.
Le présent document ne s’applique pas :
- aux systèmes de retenue contrôlés électriquement selon l’EN 14637 ;
- aux dispositifs de sélection des vantaux selon l’EN 1158 ;
- aux dispositifs de retenue électromagnétique pour portes battantes selon l’EN 1155.
Les exigences et les méthodes d'essai pour les systèmes de blocage ne font pas partie de ce document
Les exigences et méthodes d'essai supplémentaires pour l'utilisation d’opérateurs motorisés avec fonction de fermeture automatique sur les portes battantes à deux vantaux sont décrites dans la norme EN 1158 et ne font donc pas partie du présent document.

Pogoni avtomatskih nihajnih vrat za prehod ljudi s funkcijo samozapiranja - Zahteve in preskusne metode

General Information

Status
Published
Publication Date
30-Mar-2021
Withdrawal Date
29-Sep-2021
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
31-Mar-2021
Due Date
23-May-2021
Completion Date
31-Mar-2021

Buy Standard

Standard
EN 17372:2021
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2021
Pogoni avtomatskih nihajnih vrat za prehod ljudi s funkcijo samozapiranja -
Zahteve in preskusne metode
Power operated pedestrian swing door drives with self closing function - Requirements
and test methods
Kraftbetätigte Drehflügeltürantriebe mit Selbstschließfunktion - Anforderungen und
Prüfverfahren
Opérateurs motorisés de portes battantes pour piétons avec fonction de fermeture
automatique - Exigences et méthodes d’essai
Ta slovenski standard je istoveten z: EN 17372:2021
ICS:
91.060.50 Vrata in okna Doors and windows
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EN 17372
EUROPEAN STANDARD
NORME EUROPÉENNE
March 2021
EUROPÄISCHE NORM
ICS 91.060.50
English Version
Power operated pedestrian swing door drives with self
closing function - Requirements and test methods
Opérateurs motorisés de portes battantes pour piétons Kraftbetätigte Drehflügeltürantriebe mit
avec fonction de fermeture automatique - Exigences et Selbstschließfunktion - Anforderungen und
méthodes d'essai Prüfverfahren
This European Standard was approved by CEN on 18 January 2021.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 17372:2021 E
worldwide for CEN national Members.

Content Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Product characteristics . 8
4.1 General . 8
4.2 Self-closing . 9
4.2.1 Self-closing function during passive mode . 9
4.2.2 Reactivation of active mode . 9
4.2.3 Opening angle . 9
4.2.4 Opening time . 10
4.2.5 Backcheck in passive mode . 10
4.2.6 Permanent hold-open function . 10
4.3 Durability of self-closing function . 10
4.3.1 Durability during active mode . 10
4.3.2 Durability during passive mode . 10
4.3.3 Durability of damped closing . 10
4.3.4 Durability of manual triggering of the hold-open function . 11
4.3.5 Durability - closing time during passive mode . 11
4.3.6 Durability - Behaviour during blocking . 11
4.3.7 Durability - Temperature dependency in passive mode . 11
4.4 Information for use . 11
5 Testing, assessment and sampling methods . 11
5.1 Functional test and durability test . 11
5.1.1 General . 11
5.1.2 Test door . 12
5.1.3 Installation of the power-operated pedestrian swing door drive with self-closing
function . 12
5.1.4 Test samples, testing and compliance criteria . 12
5.1.5 Tolerances . 12
5.1.6 Temperature tests . 13
5.2 Self closing tests . 13
5.2.1 Self closing function during passive mode . 13
5.2.2 Reactivation of active mode . 13
5.2.3 Opening angle . 13
5.2.4 Opening time . 13
5.2.5 Backcheck in passive mode . 14
5.2.6 Permanent hold-open function . 14
5.3 Durability of self-closing tests . 14
5.3.1 Durability during active mode . 14
5.3.2 Durability during passive mode . 14
5.3.3 Durability of the damped closing . 15
5.3.4 Durability of manual triggering of the hold-open function . 15
5.3.5 Durability of closing time during passive mode . 16
5.3.6 Durability - Behaviour during blocking . 16
5.3.7 Durability - Temperature dependency in passive mode . 16
5.4 Inspection of Information for use . 16
6 Marking and labelling . 17
Annex A (normative) Flow diagram test sequence functional test and durability test . 18
Annex B (informative) Overview of tests and related requirements . 19
Bibliography . 20

European foreword
This document (EN 17372:2021) has been prepared by Technical Committee CEN/TC 33 “Doors,
windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by September 2021, and conflicting national standards
shall be withdrawn at the latest by September 2021.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
In addition to meeting requirements and test methods of this document, it could be essential that
power-operated pedestrian swing door drives with self-closing function satisfy further technical rules
(e.g. 2014/30/EU, Electromagnetic compatibility, 2006/42/EC, Machine Directive) in regard to the
safety in use and the intended application in buildings.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the
United Kingdom.
1 Scope
This document is applicable to power-operated pedestrian swing door drives with self closing function
using mechanically stored energy for single and double leaf swing doorsets with or without fire
resistance and smoke control characteristics. It defines requirements and test methods for the self-
closing function.
This document does not apply to:
— electrically controlled hold-open systems according to EN 14637;
— door coordinating devices according to EN 1158;
— electrically powered hold-open devices for swing doors according to EN 1155.
Requirements and test methods for hold-open systems are not part of this document.
Additional requirements and test methods for the use of power-operated pedestrian swing door drives
with self closing function on double-leaf swing doors are described in EN 1158 and are therefore not
part of this document.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 1154, Building hardware — Controlled door closing devices — Requirements and test methods
EN 1155, Building hardware — Electrically powered hold-open devices for swing doors — Requirements
and test methods
EN 16005, Power operated pedestrian doorsets — Safety in use — Requirements and test methods
EN ISO 13849-1, Safety of machinery — Safety-related parts of control systems — Part 1: General
principles for design (ISO 13849-1)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 1154, EN 1155 and the
following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— IEC Electropedia: available at http://www.electropedia.org/
— ISO Online browsing platform: available at https://www.iso.org/obp
3.1
power-operated pedestrian swing door drive with self-closing function
drive that is equipped with a self-closing function for moving a swing door leaf
3.2
self-closing function
function for closing a swing door leaf by means of mechanically stored energy which is preserved even
in case of power failure
3.3
adjustable closing force
in-
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.