Spectator facilities - Part 1: General characteristics for spectator viewing area

This European Standard specifies design and management requirements for spectator facilities at permanent or temporary entertainment venues including sport stadia, sport halls, indoor and outdoor facilities for the purpose of enabling their functionality.
This European Standard is not applicable to other permanent venues such as theatres, cinemas, opera houses, auditoriums, lecture halls and similar places where persons congregate.
NOTE   Provisions for media facilities are not included in this standard.

Zuschaueranlagen - Teil 1: Allgemeine Merkmale für Zuschauerplätze

Diese Europäische Norm legt Konstruktions  und Managementanforderungen an Zuschaueranlagen für ortsfeste oder provisorische Veranstaltungsorte wie Stadien, Sporthallen sowie Anlagen in Gebäuden und im Freien fest, um deren Funktionalität sicherzustellen.
Diese Europäische Norm gilt nicht für andere ortsfeste Veranstaltungsorte wie Theater, Kinos, Opernhäuser, Aulas, Hörsäle und ähnliche Stätten, an denen Menschen zusammenkommen.
ANMERKUNG   Bestimmungen für mediale Anlagen sind nicht in dieser Norm enthalten.

Installations pour spectateurs - Partie 1: Caractéristiques générales des espaces d'observation pour spectateurs

La présente Norme européenne spécifie les exigences de conception et de gestion relatives aux installations pour spectateurs en des lieux de divertissement permanents ou temporaires, y compris les stades sportifs, les salles de sport, les installations intérieures et extérieures, l’objectif visé étant d’en assurer la fonctionnalité.
D’autres lieux permanents comme les théâtres, les salles de cinéma, les opéras, les amphithéâtres et autres salles similaires où des personnes se rassemblent sont exclus de la présente Norme européenne.
NOTE   La présente norme ne traite pas des installations pour les médias.

Prostori za gledalce - 1. del: Splošne značilnosti za vidno polje gledalcev

Ta evropski standard določa zahteve načrtovanja in upravljanja prostorov za gledalce na trajnih ali začasnih prireditvenih prizoriščih, vključno s športnimi stadioni, športnimi dvoranami ter drugimi notranjimi in zunanjimi prostori, za namene zagotavljanja njihove funkcionalnosti. Ta evropski standard se ne uporablja za druga trajna prizorišča, kot so gledališča, kinodvorane, operne hiše, avditoriji, predavalnice in druga podobna mesta, kjer se zbirajo ljudje.

General Information

Status
Withdrawn
Publication Date
28-Aug-2012
Withdrawal Date
26-Feb-2019
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
27-Feb-2019

Relations

Buy Standard

Standard
EN 13200-1:2012
English language
32 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Zuschaueranlagen - Teil 1: Allgemeine Merkmale für ZuschauerplätzeInstallations pour spectateurs - Partie 1: Caractéristiques générales des espaces d'observation pour spectateursSpectator facilities - Part 1: General characteristics for spectator viewing area97.220.10Športni objektiSports facilities97.200.10Gledališka, odrska in studijska oprema ter delovne postajeTheatre, stage and studio equipment91.040.10Javne stavbePublic buildingsICS:Ta slovenski standard je istoveten z:EN 13200-1:2012SIST EN 13200-1:2012en,de01-november-2012SIST EN 13200-1:2012SLOVENSKI
STANDARDSIST EN 13200-1:20041DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13200-1
August 2012 ICS 91.040.10; 97.200.10; 97.220.10 Supersedes EN 13200-1:2003English Version
Spectator facilities - Part 1: General characteristics for spectator viewing area
Installations pour spectateurs - Partie 1: Caractéristiques générales des espaces d'observation pour spectateurs
Zuschaueranlagen - Teil 1: Allgemeine Merkmale für Zuschauerplätze This European Standard was approved by CEN on 13 July 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13200-1:2012: ESIST EN 13200-1:2012

Example of Spectator Facility . 23Annex B (informative)
Largest distance of vision . 25Annex C (informative)
Classification of sports areas and criteria for the determination of groups . 27Annex D (informative)
Roof coverings of stands . 30Annex E (informative)
Flow capacity from exit from viewing area . 31Bibliography . 32 SIST EN 13200-1:2012

Attention is drawn to the fact that in certain countries additional/different requirements may be applicable due to existing national regulations or equivalent. In certain countries, the minimum number of spectators is related to the application of this standard. SIST EN 13200-1:2012

EN 1991-1-1, Eurocode 1: Actions on structures  Part 1-1: General actions  Densities, self-weight, imposed loads for buildings 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 spectator facility area of congregation comprising an activity area, a viewing area and a service area Note 1 to entry: A spectator facility includes all the spaces where the public assembles, indoors or outdoors, permanently or temporarily, views sports, entertainment or miscellaneous events (see Annex A). 3.2
activity area area where the event takes place 3.3 viewing area area from which the spectators view the event Note 1 to entry: The viewing area includes stands for spectators seated, standing and with special needs, passageways and gangways necessary for circulation, vomitories for entry and exit. 3.4
service area area where publically accessible utilities are found Note 1 to entry: The service area includes toilets, first aid, cafeterias, souvenirs shop, including passages, concourses, ramps and stairs between the viewing area and the external area (see Annex A). 3.5 place space in the viewing area needed for a safe and good view of the event taking place, which is for a spectator who is sitting or standing or a wheelchair-user
vomitory element of passage that provides entry to or exit from the viewing area 3.7 stand
structure providing a viewing area 3.8 sector unit of the viewing area comprising one or more similar blocks 3.9 block unit of the viewing area comprising a number of rows between rear and/or front gangways and one or two lateral passageways 3.10 row line of a number of similar and adjacent places for spectators that are laterally spaced 3.11 passageway access route to a sector or block Note 1 to entry: A passageway, on level ground, slope or stair, includes vomitory and gangway. 3.12
sightline line joining the eye of a spectator and the point of interest on the activity area without optical interruption 3.13 point of interest point on the activity area from which the sightline is linked to the eye point 3.14 design capacity total number of spectators for which a spectator facility or some division of a spectator facility (block or sector) is designed 3.15 flow capacity number of spectators that can safely pass through a given width of a space in a specified time 3.16 viewing slope non-stepped sloping area providing standing accommodation for the spectator 3.17 place of safety place where a person is no longer in danger from fire or other emergencies 3.18
external area place external to the activity area, viewing area and service area intended to be used as public road, parking and passages for spectators SIST EN 13200-1:2012

facility in which both the activity area and viewing area are covered and enclosed 3.20 outdoor facility open facility or uncovered activity area 4 Mate
...