Abstract

This document provides guidance for the design of ventilation systems for basic ventilation in residential buildings to achieve an acceptable indoor air quality. It gives two approaches:
-   prescriptive approach;
-   performance-based approach.
This document establishes guidelines for the usage of both the prescriptive and performance-based approaches. This document specifies performance indicators that can be used with the performance-based approach.
This document partly covers intensive ventilation for indoor air quality purposes.
This document concerns residential buildings but primarily focuses on dwellings (flats, apartments, and houses) and is also applicable to parts of other types of residential buildings.
This document is applicable to, but not limited to:
-   mechanical ventilation;
-   natural ventilation;
-   hybrid ventilation.
This document does not apply to:
-   dilution of tobacco smoke or radon and other soil gases;
-   ventilation of garages, roof voids, sub-floor voids, wall cavities and other spaces in the structure, under, over or around the living space;
-   providing air for combustion appliances;
-   air cleaning (e.g. portable stand-alone air cleaners to clean the indoor air);
-   air humidification or de-humidification;
-   thermal comfort in regard to overheating aspects.
This document does not deal with the assessment of energy performance of buildings.

Status
Not Published
Publication Date
22-Nov-2026
Current Stage
4599 - Dispatch of FV draft to CMC - Finalization for Vote
Start Date
29-Jun-2026
Due Date
22-Jun-2026
Completion Date
22-Jun-2026

Buy Documents

FprEN 15665 is a draft European Standard from CEN on the design of ventilation systems for residential buildings. It gives guidance for basic ventilation so designers can aim for acceptable indoor air quality, using either a prescriptive approach or a performance-based approach. It is written for people who set, design, specify, manufacture or assess residential ventilation systems.

What does FprEN 15665 specify?

FprEN 15665 gives design guidance for residential ventilation systems with the main goal of acceptable indoor air quality. It covers dwellings first, but it also applies to parts of other residential buildings, and it includes mechanical ventilation, natural ventilation and hybrid ventilation.

The document also allows for intensive ventilation for indoor air quality purposes, but only in part. It excludes several other functions such as smoke dilution, radon and soil gas dilution, garage and cavity ventilation, combustion air supply, air cleaning, humidification and de-humidification, and overheating-related thermal comfort.

The document is organized into clauses on scope, terms, limitation of options, design aspects, technical aspects, primary ventilation requirements, the two design approaches, the performance assessment method, and documentation. It also includes a set of informative annexes and one normative annex on national limitations.

AnnexWhat it covers
Annex ATemplate for limiting the use of options and technical solutions at national level
Annex BExamples of primary ventilation requirements and prescriptive requirements
Annex CComparison of the performance-based and prescriptive approaches
Annex DDesign aspects specific to mechanical ventilation
Annex EDesign aspects specific to natural ventilation
Annex FDesign aspects specific to hybrid ventilation
Annex GControl equipment
Annex HTypical performance indicators for the performance-based approach
Annex ISpecifying design assumptions
Annex JUsage agreement for operation

What are the key requirements of FprEN 15665?

FprEN 15665 is built around a simple idea: define the ventilation target first, then choose a design approach and check that the system can meet that target. In practice, this means the document is more about how to set up and assess a residential ventilation design than about fixing one universal sizing rule.

National choices and permitted options

Clause 5 allows national annexes to limit which options and technical solutions may be used. Annex A provides the template for those national choices, and Annex B gives examples. This matters because what is suitable in one climate or regulatory context may not be suitable in another.

Main purpose and design considerations

Clause 6 states that the main purpose of ventilation is acceptable indoor air quality, while also helping control humidity. It notes other design aspects that should be considered during design, including energy use, acoustics, draught, outdoor pollutants, and operation, maintenance and cleaning. The practical message is that a ventilation design should not be judged only on air replacement.

Ventilation strategy, operating principle and control

Clause 7 requires the designer to define a ventilation strategy, an operating principle and the control equipment. The ventilation strategy is the planned air path through habitable rooms, circulation rooms and service rooms, and it is meant to avoid spreading pollutants within the building. The document lists example strategies STR 1 to STR 7, which is important because the chosen air path affects both indoor air quality and energy use.

Clause 7 also distinguishes mechanical ventilation, natural ventilation and hybrid ventilation, and it describes control options such as no control, manual control, time control, presence control and demand control. It also distinguishes central, zonal and local control. In practice, this tells the designer what kind of control logic and sensor arrangement must be documented.

Airtightness and air leakage

Clause 7.5 explains that building airtightness and air leakage can disturb room pressure differences and air paths. This can reduce the intended air flow through intake and exhaust vents and can move polluted air from one room to another. The practical implication is that airtightness is part of the ventilation design, not a separate issue.

Primary ventilation requirements

Clause 8 says the document does not itself set the primary ventilation requirements, but it gives guidance for expressing them. Those requirements can be stated as air flow rates, IAQ criteria, or both, provided equivalent parallel approaches are used if both are allowed. Air flow rate requirements are expressed per room and can be based on room area, floor area or number of people, while IAQ requirements are stated at occupant, room or dwelling level.

Performance-based and prescriptive approaches

Clause 8 separates two ways of designing ventilation systems. The performance-based approach uses performance indicators and a performance assessment method, while the prescriptive approach uses descriptive requirements such as opening area or reference pressure difference. This distinction matters because it tells the reader whether the design is judged by results or by specified technical means.

Design steps and assessment

Clauses 9 and 10 describe the design steps for each approach. For the performance-based approach, the designer selects the allowed strategy, operating principle and control, then verifies the system using the performance assessment method in Clause 11. For the prescriptive approach, the designer applies the primary requirements and then uses descriptive technical requirements so the system can be assumed to meet them.

Clause 11 defines the performance assessment method. It uses performance indicators, calculation models, input data and result aggregation to show compliance with the primary ventilation requirements. The method can be used for a specific building or for a ventilation installation package, which is important for both project design and product development.

Documentation

Clause 12 requires documentation of specifications and layout, including component positions, terminal devices, ductwork, fans, assumptions and model inputs. This is the part that supports handover, design review and later checking of the designed system.

What terms does FprEN 15665 define?

  • Ventilation - air replacement by purpose-provided means, which means the system is deliberately designed to control air movement.
  • Basic ventilation - ventilation intended to achieve primary ventilation requirements under normal circumstances.
  • Intensive ventilation - increased air replacement for a specific purpose for a limited time, such as purge ventilation.
  • Ventilation strategy - the planned path of air within the building, including how rooms are connected by supply, transfer and extract air.
  • Primary ventilation requirement - a requirement that defines the target indoor air quality or the amount of air replacement to be achieved.
  • Performance indicator - a quantity that shows performance over a period, such as hours above a humidity threshold or an air flow-based measure.
  • Hybrid ventilation - ventilation based on a combination or alternation of natural ventilation and mechanical ventilation.
  • Indoor air quality (IAQ) - the quality of indoor air as characterized by relevant parameters such as carbon dioxide, volatile compounds or water vapour.

Who uses FprEN 15665?

FprEN 15665 is used by national standardization bodies, designers, manufacturers and project teams working on residential ventilation. It is relevant to consulting engineers, architects, building contractors, building owners, and operation and maintenance personnel.

In practice, national bodies use it to set national requirements in a controlled way, manufacturers use it when defining ventilation installation packages, and designers use it to select strategies, control methods and sizing assumptions. Buyers and quality managers can use it to check whether a proposed residential ventilation solution is based on a prescriptive route or on a performance-based demonstration.

What changed in FprEN 15665 from the previous edition?

FprEN 15665 will supersede EN 15665:2009 and CEN/TR 14788:2006. The foreword states that, besides editorial revisions, the main changes are the clear distinction between the prescriptive approach and the performance-based approach, and the addition of a normative National Annex A with open templates for both approaches.

Which standards are used with FprEN 15665?

FprEN 15665 has no normative references in Clause 2, but it points to several companion standards and related documents in the foreword, introduction and bibliography.

  • EN 16798-1 - gives indoor environmental input parameters for design and assessment, including IAQ, thermal environment, lighting and acoustics.
  • EN 16798-7:2017 - provides calculation methods for determining air flow rates in buildings, including infiltration.
  • CEN/TR 16798-2 - gives interpretation of EN 16798-1.
  • EN 13142:2021 - lists required and optional performance characteristics for residential ventilation components and products.
  • EN 13141-1 - covers performance testing of air transfer devices.
  • EN 14351-1:2006+A2:2016 - is relevant for windows and doors used as openings in natural ventilation.
  • EN 12097, EN 12237 and EN 15780 - relate to ductwork components, duct strength and leakage, and cleanliness.
  • EN 16798-3, EN 16798-5-1, EN 16798-5-2 and CEN/TR 16798-6 - are referenced for related ventilation and energy calculation and design topics.

What does the FprEN 15665 document contain?

FprEN 15665 contains guidance, examples and supporting annexes rather than a single fixed sizing rule. It includes example ventilation strategies in Clause 7, examples of design approaches in Figures 8 and 9, and detailed annex material for mechanical, natural and hybrid ventilation.

The document also includes example requirement sets in Annex B, a comparison of the two design approaches in Annex C, and control equipment guidance in Annex G. Annex H lists typical performance indicator types, Annex I groups the design assumptions the designer should define, and Annex J gives a usage agreement framework for operation and project responsibilities.

It is therefore a document for design planning, performance checking and documentation of residential ventilation systems, not a product-only or test-only standard.

Relations

Effective Date
15-Nov-2023
Effective Date
19-Jan-2023

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

FprEN 15665 is a draft published by the European Committee for Standardization (CEN). Its full title is "Ventilation for buildings - Ventilation systems in residential buildings - Design". This standard covers: This document provides guidance for the design of ventilation systems for basic ventilation in residential buildings to achieve an acceptable indoor air quality. It gives two approaches: - prescriptive approach; - performance-based approach. This document establishes guidelines for the usage of both the prescriptive and performance-based approaches. This document specifies performance indicators that can be used with the performance-based approach. This document partly covers intensive ventilation for indoor air quality purposes. This document concerns residential buildings but primarily focuses on dwellings (flats, apartments, and houses) and is also applicable to parts of other types of residential buildings. This document is applicable to, but not limited to: - mechanical ventilation; - natural ventilation; - hybrid ventilation. This document does not apply to: - dilution of tobacco smoke or radon and other soil gases; - ventilation of garages, roof voids, sub-floor voids, wall cavities and other spaces in the structure, under, over or around the living space; - providing air for combustion appliances; - air cleaning (e.g. portable stand-alone air cleaners to clean the indoor air); - air humidification or de-humidification; - thermal comfort in regard to overheating aspects. This document does not deal with the assessment of energy performance of buildings.

This document provides guidance for the design of ventilation systems for basic ventilation in residential buildings to achieve an acceptable indoor air quality. It gives two approaches: - prescriptive approach; - performance-based approach. This document establishes guidelines for the usage of both the prescriptive and performance-based approaches. This document specifies performance indicators that can be used with the performance-based approach. This document partly covers intensive ventilation for indoor air quality purposes. This document concerns residential buildings but primarily focuses on dwellings (flats, apartments, and houses) and is also applicable to parts of other types of residential buildings. This document is applicable to, but not limited to: - mechanical ventilation; - natural ventilation; - hybrid ventilation. This document does not apply to: - dilution of tobacco smoke or radon and other soil gases; - ventilation of garages, roof voids, sub-floor voids, wall cavities and other spaces in the structure, under, over or around the living space; - providing air for combustion appliances; - air cleaning (e.g. portable stand-alone air cleaners to clean the indoor air); - air humidification or de-humidification; - thermal comfort in regard to overheating aspects. This document does not deal with the assessment of energy performance of buildings.

FprEN 15665 is classified under the following ICS (International Classification for Standards) categories: 91.140.30 - Ventilation and air-conditioning systems. The ICS classification helps identify the subject area and facilitates finding related standards.

FprEN 15665 has the following relationships with other standards: It is inter standard links to CEN/TR 14788:2006, EN 15665:2009. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

FprEN 15665 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 ventilation
  • 3.2 basic ventilation
  • 3.3 intensive ventilation
  • 3.4 natural ventilation
  • 3.5 mechanical ventilation
  • 3.6 hybrid ventilation
  • 3.7 airing
  • 3.8 stack effect
  • 3.9 habitable room
  • 3.10 service room
  • 3.11 circulation room
  • 3.12 vent
  • 3.13 intake vent
  • 3.14 exhaust vent
  • 3.15 residential
  • 3.16 primary ventilation requirement
  • 3.17 descriptive requirement
  • 3.18 performance-based requirement
  • 3.19 IAQ parameter
  • 3.20 performance indicator
  • 3.21 supply air
  • 3.22 transferred air
  • 3.23 extract air
  • 3.24 ventilation system
  • 3.25 package
  • 3.26 ventilation system package
  • 3.27 exposure
  • 3.28 cumulative exposure
  • 4 Abbreviated terms
  • 5 Limitation of the use of options and technical solutions
  • 6 Main purpose and other design aspects of ventilation
  • 6.1 Main purpose of ventilation
  • 6.2 Other design aspects related to ventilation
  • 7 Technical aspects of a ventilation system
  • 7.1 General
  • 7.2 Ventilation strategy (ventilation organization plan)
  • 7.3 Operating principle
  • 7.4 Control equipment
  • 7.5 Building airtightness
  • 8 Primary ventilation requirements and design approaches
  • 8.1 General
  • 8.2 Expression of primary ventilation requirements
  • 8.3 Performance-based approach
  • 8.4 Prescriptive approach
  • 9 Design steps for the performance-based approach
  • 9.1 General
  • 9.2 Design of a ventilation system in a specific building
  • 9.3 Design of ventilation installation package
  • 10 Design steps for the prescriptive approach
  • 11 Performance assessment method
  • 11.1 General approach
  • 11.2 Primary ventilation requirements and performance indicators
  • 11.3 Calculation model and assumptions
  • 11.4 Aggregation of the calculation results
  • 12 Documentation of specifications and layout
  • Annex A
  • Annex NA
  • Annex B
  • Annex C
  • Annex D
  • Annex E
  • Annex F
  • Annex G
  • Annex H
  • Annex I
  • Annex J
  • Bibliography

Introduction

The main role of ventilation is to replace the air in order to ensure an acceptable indoor air quality. It also helps to maintain the integrity of the building and improve the comfort of its occupants by controlling the humidity to avoid too low and too high humidity. But this document only focuses on indoor air quality. Ventilation dilutes natural background pollutants such as substances emitted by furnishings, building materials and cleaning products used in the building, odours, metabolic CO and water vapour.

Ventilation also dilutes specific pollutants from identifiable local sources such as toilet odours, water vapour from the kitchen or bathroom.

Design of ventilation systems commonly considers other aspects like energy use, acoustics, draught, outdoor pollutants and cleaning and maintenance, though these are not covered in detail in this document.

There are both risks for the occupants and the building in terms of IAQ, specifically of relative humidity (one indicator for indoor air quality and thermal comfort).

IAQ can be controlled by the following means: source control, ventilation, and potentially air filtration or air cleaning.

This document is intended to support any regulation or standard at national level by giving guidance to those with responsibility for producing requirements and standards for residential ventilation systems. It includes a national annex template for fixing choices and setting primary ventilation requirements at national level. A filled in national annex, is directly usable by the designer for precise requirements on design of a ventilation system.

This document has a link to EN 16798-1 and EN 16798-7, in which basic information on possible indoor air quality requirements can be found, and gives information on how to calculate air flow rates in buildings.

oSIST prEN 15665:2025 prEN 15665:2024 (E)

1 Scope

This document provides guidance for the design of ventilation systems for basic ventilation in residential buildings to achieve an acceptable indoor air quality. It gives two approaches:

  • prescriptive approach;
  • performance-based approach.

This document establishes guidelines for the usage of both the prescriptive and performance-based approaches. This document specifies performance indicators that can be used with the performancebased approach. This document partly covers intensive ventilation for indoor air quality purposes. This document concerns residential buildings but primarily focuses on dwellings (flats, apartments, and houses) and is also applicable to parts of other types of residential buildings. This document is applicable to, but not limited to:

  • mechanical ventilation;
  • natural ventilation;
  • hybrid ventilation.

This document does not apply to:

  • dilution of tobacco smoke or radon and other soil gases;
  • ventilation of garages, roof voids, sub-floor voids, wall cavities and other spaces in the structure, under, over or around the living space;
  • providing air for combustion appliances;
  • air cleaning (e.g. portable stand-alone air cleaners to clean the indoor air);
  • air humidification or de-humidification;
  • thermal comfort in regard to overheating aspects.

This document does not deal with the assessment of energy performance of buildings.

2 Normative references

There are no normative references in this document.

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for the use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp
  • IEC Electropedia: available at https://www.electropedia.org/

oSIST prEN 15665:2025 prEN 15665:2024 (E)

3.1 ventilation

air replacement by purpose-provided means Note 1 to entry: “purpose-provided means” implies design and characterizes knowledge of main characteristics allowing assessment so that requirements on ventilation are fulfilled. Note 2 to entry: Ventilation can be combined with air treatment.

3.2 basic ventilation

ventilation to achieve primary ventilation requirements under normal circumstances

3.3 intensive ventilation

ventilation at increased air replacement rate for a specific purpose limited in time

3.4 natural ventilation

ventilation whose operating principle is based solely on the effect of wind and the stack effect Note 1 to entry: Open windows can be used for natural ventilation, if they are purpose-provided.

3.5 mechanical ventilation

ventilation whose operating principle is based solely on the operation of fans

3.6 hybrid ventilation

ventilation whose operating principle is based on the combination or alternation of natural ventilation and mechanical ventilation

3.7 airing

air replacement by means that are not purpose-provided Note 1 to entry: Usually done through manual opening of doors or windows or both.

3.8 stack effect

pressure difference caused by the difference in density between indoor air and outdoor air due to their temperature difference Note 1 to entry: With increased height difference between openings and temperature difference between indoor and outdoor air, the stack effect flow increases.

3.9 habitable room

main room room dedicated to living, sleeping or dining purpose EXAMPLE living room, bedroom, dining room, home office

oSIST prEN 15665:2025 prEN 15665:2024 (E)

3.10 service room

wet room room dedicated to cooking, washing, defecating or urinating purpose EXAMPLE kitchen, bathroom, laundry, toilet

3.11 circulation room

room with no specific allocation except circulation within the building EXAMPLE corridor, hall, stairwell

3.12 vent

opening in the building shell intended for passage of air EXAMPLE externally mounted air transfer device, intake air terminal device, roof outlet or window designed for the purpose of air replacement

3.13 intake vent

vent through which air is taken from outside the building

3.14 exhaust vent

vent through which air is discharged to outside the building

3.15 residential

relating to where people live

3.16 primary ventilation requirement

requirement aiming to quantify a level of indoor air quality to be achieved or an amount of air replacement to be achieved

3.17 descriptive requirement

requirement in the form of a specified technical solution EXAMPLE minimum opening area

3.18 performance-based requirement

requirement in the form of a goal to be achieved

3.19 IAQ parameter

quantity that enables the characterization of indoor air quality, in whole or in part EXAMPLE CO concentration

oSIST prEN 15665:2025 prEN 15665:2024 (E)

3.20 performance indicator

quantity that indicates a performance EXAMPLE Number of hours under or above a humidity threshold.

3.21 supply air

air from a ventilation installation or air conditioning installation entering a room

3.22 transferred air

air which passes from a room to another room Note 1 to entry: Transferred air is extract air from one room and supply air for the other room.

3.23 extract air

air from a room entering a ventilation installation or air conditioning installation

3.24 ventilation system

combination of a ventilation installation and the enclosure it serves

3.25 package

group of objects, plans, or arrangements that are related and offered as a unit

3.26 ventilation system package

ventilation installation package package intended for the realisation of a ventilation installation Note 1 to entry: An installation ready package.

3.27 exposure

concentration of a given substance a person is exposed to

3.28 cumulative exposure

exposure that a specific person experiences over a given period of time

4 Abbreviated terms

For the purposes of this document, the abbreviations given in Table 1 apply. Table 1 — Abbreviated terms Abbreviated terms Designation ACH Air Change Rate BAC Building Automation and Control CO Carbon dioxide

oSIST prEN 15665:2025 prEN 15665:2024 (E) Abbreviated terms Designation EMATD Externally Mounted Air Transfer Devices EN European Standard IAQ Indoor Air Quality PM Particulate Matter RH Relative Humidity STR Ventilation strategy SVOC's Semi-Volatile Organic Compounds VOC's Volatile organic compounds

5 Limitation of the use of options and technical solutions

This document describes various options and technical solutions. Limitations of the use of these options and technical solutions may be provided in a national annex. If a national annex is created it shall be done in accordance with the template given in Annex A.

Examples of filled in templates are given in Annex B.

NOTE The reason for this possible limitation is that not all options and technical solutions are relevant for all national conditions (e.g. climatic conditions).

These options and technical solutions concern:

  • the ventilation strategies, operating principles and controlling equipment (see Clause 7);
  • the primary ventilation requirements (see Clause 8);
  • the choice of the performance-based approach (see Clause 8 and Clause 9) or the prescriptive approach (see Clause 8 and Clause 10) or both approaches;
  • the performance assessment method (see Clause 11).

6 Main purpose and other design aspects of ventilation

6.1 Main purpose of ventilation

The main purpose of ventilation is to achieve an acceptable indoor air quality (basic ventilation) with relevant IAQ parameters (e.g. CO , VOC's, water vapour).

Ventilation is also an important mean of controlling humidity in a building in order to reduce the risk of condensation on building walls and materials.

Basic ventilation covers normal circumstances. Ventilation can sometimes be increased for a specific purpose for a given period of time (intensive ventilation). This can be done whatever the operating principle (mechanical ventilation, natural ventilation or hybrid ventilation). Airing is another possible option to supplement a ventilation system for such increase of the air replacement rate.

However, ventilation can have consequences, possibly negative, such as energy use or unwanted draught. The main possible consequences of ventilation are listed in 6.2 and are not further detailed in this

oSIST prEN 15665:2025 prEN 15665:2024 (E) document. The design of a ventilation system should take these consequences into account to minimize their possible negative effects.

6.2 Other design aspects related to ventilation

6.2.1 Energy use

During the design of the ventilation system, the following possible aspects of energy use related to ventilation should be considered:

  • the energy use for heating and cooling;
  • the energy use for the transport of the ventilation air (fan electrical energy);
  • the energy use for the control equipment;
  • the energy use for humidification or de-humidification.

When designing a ventilation system, IAQ should be considered together with the energy implications, although the assessment of energy performance of buildings is not dealt with in this document. NOTE EN 16798-5-1, EN 16798-5-2 and CEN/TR 16798-6 are about calculation of energy requirements for mechanical and air-conditioning systems.

Some aspects of the energy use due to ventilation can also be an output of the performance assessment method (see Clause 11).

6.2.2 Acoustics

During the design of the ventilation system, the following possible aspects of acoustics should be considered:

  • the noise from the inside environment;
  • the noise from the outside environment;
  • the noise generated indoors and outdoors by the ventilation system itself (e.g. fans, dampers, air flows and actuators).

The noise caused by the ventilation system can cause nuisance to the occupants and hence influence their use of the ventilation system.

NOTE EN 16798-1 provides basic information on possible acoustic criteria, but acoustic criteria can also be found, e.g. in national legislation.

6.2.3 Draught

During the design of the ventilation system, unwanted draught possibly caused by ventilation air flows should be considered.

This draught can cause nuisance to the occupants and hence influence their use of the ventilation system. NOTE EN ISO 7730 and EN 16798-1 provides basic information on possible criteria on draught.

6.2.4 Outdoor pollutants

During the design of the ventilation system, the outdoor air quality should be considered. Technical solutions to handle outdoor pollutants include, for example, proper placement of intake vents, filtration, demand controlled ventilation based on outdoor air quality or air cleaning.

oSIST prEN 15665:2025 prEN 15665:2024 (E) NOTE For mechanical ventilation systems, information on filtration and its classification is available in EN 16798-3.

6.2.5 Operation, maintenance and cleaning

Cleaning and maintenance of the ventilation installation are necessary to maintain the performance of the ventilation system over time.

During the design of the ventilation system, the following aspects should be considered:

- accessibility to the components to be replaced (e.g. filters); - accessibility to the components to be cleaned (e.g. ducts, fans, air transfer devices or air terminal devices); The use of filters can also help to protect the ventilation system against fouling. NOTE 1 Information about requirements for ductwork components to facilitate maintenance of ductwork systems is available in EN 12097.

NOTE 2 Information about cleanliness of ventilation system is available in EN 15780. NOTE 3 For design and operation it is possible that the relevant usage of the rooms, and the requirements, in particular, are done in writing in a usage agreement. Such a usage agreement is often between the building owner, designer and user. An example of a usage agreement during operation is given in Annex J.

7 Technical aspects of a ventilation system

7.1 General

Ventilation strategy, controlling system and operating principle are technical aspects that can be used to define a ventilation system. These aspects are combined together during the design of the ventilation system (see Clause 9 and Clause 10).

7.2 Ventilation strategy (ventilation organization plan)

The ventilation strategy is a detailed plan that defines the path of air within a building. The ventilation strategy is usually based on a distinction between habitable rooms, circulation rooms and service rooms. It may however also include other rooms. These other rooms are treated like habitable rooms or service rooms or treated separately depending on the expected generated indoor pollution. Examples of other rooms are storage room, dressing room, home gym room and garage. One of the main principles of a good ventilation strategy is to avoid spreading of pollutants within the building. Air from service rooms is therefore not suitable for recirculation or transfer to other rooms. Different ventilation strategies can have different impact on the energy use (see 6.2.1); transferring air from one room to another is therefore often considered.

Examples of ventilation strategies are given in Table 2 and Figures 1 to 7. Additional ventilation strategies may be defined in a national Annex A.

oSIST prEN 15665:2025 prEN 15665:2024 (E) Table 2 — Examples of ventilation strategies Ventilation strategy Description STR Supply of air in all habitable rooms and service rooms STR 1 Extraction of air from all habitable rooms and service rooms There is no provision for ventilation of circulation rooms Supply of air in all habitable rooms Transfer of air in all circulation rooms from habitable rooms STR 2 Transfer of air in all service rooms from circulation rooms (or habitable rooms if not connected to circulation room) Extraction of air from all service rooms Supply of air in all habitable rooms Transfer of air in all circulation rooms from habitable rooms Transfer of air in all service rooms from circulation rooms (or habitable rooms STR 3 if not connected to circulation room) Extraction of air from all service rooms Extraction of air from some or all habitable rooms Supply of air in circulation rooms Transfer of air in all habitable rooms from circulation rooms Transfer of air in all service rooms from circulation rooms (or habitable rooms STR 4 if not connected to circulation room) Extraction of air from all habitable rooms (except those that transfer air to a service room) and service rooms Supply of air in some habitable rooms (HR1) (e.g. rooms mainly occupied during the night) Transfer of air in all circulation rooms from these habitable rooms Transfer of air in all other habitable rooms (HR2) (e.g. rooms mainly occupied during the day) from circulation rooms (or first mentioned habitable rooms STR 5 (HR1) if not connected to circulation room) Transfer of air in all service rooms from last mentioned habitable rooms (HR2) or from circulation rooms Extraction of air from all service rooms and from last mentioned habitable rooms not connected to a service room Supply of air to some of the habitable rooms and some of the service rooms Extraction of air from the other habitable rooms and other service rooms STR 6 Transfer of air in all circulation rooms from rooms with supply of air Transfer of air in all rooms with extraction of air from circulation rooms (or from rooms with supply of air if not connected to a circulation room) Supply of air in all habitable rooms and service rooms.

Extraction of air from all habitable rooms and service rooms.

STR 7 Transfer of air in circulation rooms from habitable rooms.

Transfer of air from circulation rooms in habitable rooms.

oSIST prEN 15665:2025 prEN 15665:2024 (E)

Key 1 habitable room 2 circulation room 3 service room Figure 1 — Illustration of ventilation strategy STR 1

Key 1 habitable room 2 circulation room 3 service room Figure 2 — Illustration of ventilation strategy STR 2

oSIST prEN 15665:2025 prEN 15665:2024 (E)

Key 1 habitable room 2 circulation room 3 service room Figure 3 — Illustration of ventilation strategy STR 3

Key 1 habitable room 2 circulation room 3 service room Figure 4 — Illustration of ventilation strategy STR 4

oSIST prEN 15665:2025 prEN 15665:2024 (E)

Key 1 habitable room 2 circulation room 3 service room Figure 5 — Illustration of ventilation strategy STR 5

Key a habitable room or service room b circulation room Figure 6 — Illustration of ventilation strategy STR 6

oSIST prEN 15665:2025 prEN 15665:2024 (E)

Key 1 habitable room 2 circulation room 3 service room Figure 7 — Illustration of ventilation strategy STR 7

7.3 Operating principle

7.3.1 Mechanical ventilation

Mechanical ventilation can be subdivided into three different types:

  • fan assisted bidirectional ventilation that employs fans in both the supply air and extract air sides;
  • fan assisted exhaust ventilation that employs fans in the extract air side only;
  • fan assisted supply ventilation that employs fans in the supply air side only. With fan assisted exhaust ventilation, fans in the extract air side induce underpressure inside the building. This underpressure enables air to enter the building through intake vents, e.g. externally mounted air transfer devices.

With fan assisted supply ventilation, fans in the supply air side induce overpressure inside the building. This overpressure enables air to flow out of the building through exhaust vents, e.g. extract air terminal devices, cowls or externally mounted air transfer devices.

Stack effect and wind are not taken into account in the design of mechanical ventilation systems but can have an impact on the actual performance of the system.

NOTE 1 For externally mounted air transfer devices see EN 13141-1. Transfer of air within the building can be realized with internally mounted air transfer devices, door undercuts or fan and possibly a ductwork.

Depending on the number and position of fans, a distinction can be made between:

...