Preformed plasterboard cornices - Definitions, requirements and test methods

This European standard specifies the characteristics and performance of preformed plasterboard cornices intended to be used in building construction works either as part of the original specification or subsequently for improved decorative enrichment of the wall/ceiling angle in rooms.
This standard covers the performance characteristics: reaction to fire and flexural strength.
This standard covers also additional technical characteristics that are of importance for the use and acceptance of the product by the Construction Industry and the reference tests for these characteristics.
It provides for the evaluation of conformity of the product to this European standard.
This standard does not cover plain plaster and gypsum fibrous plasterwork cornices.

Hohlkehlleisten aus kartonummanteltem Gips - Begriffe, Anforderungen und Prüfverfahren

Diese Europäische Norm legt die Eigenschaften und Leistung von Hohlkehlleisten aus kartonummanteltem Gips, die im Hochbau entweder im Rahmen der ursprünglichen Leistungsbeschreibung oder zur nachträglichen dekorativen Gestaltung des Wand-/Deckenabschlusses in Räumen verwendet werden, fest.
Diese Norm behandelt die Leistungsmerkmale Brandverhalten und Biegezugfestigkeit.
Diese Norm behandelt zusätzliche technische Eigenschaften, die für die Anwendung und Akzeptanz des Produktes durch die Bauwirtschaft wichtig sind, und enthält die Referenzprüfverfahren für diese Eigenschaften.
Sie legt die Bewertung der Konformität der von dieser Europäischen Norm erfassten Produkte fest.
Diese Norm gilt weder für Hohlkehlleisten aus Gips ohne Kartonummantelung noch für Hohlkehlleisten aus faserverstärktem Gips.

Corniches préformées en plâtre revêtues de carton - Définitions, spécifications et méthodes d'essai

La présente Norme européenne définit les caractéristiques et les performances des corniches préformées en plâtre revêtues de carton destinées à être utilisées dans les ouvrages de construction de bâtiments, soit conformément au cahier des charges lui-même, soit postérieurement, en vue d’embellir la décoration intérieure des pièces au droit des angles formés par les murs et les plafonds.
Elle couvre les performance suivantes : réaction au feu et résistance à la flexion.
La présente Norme européenne couvre également des caractéristiques techniques complémentaires qui revêtent une importance pour l’utilisation et l’acceptation du produit par l’industrie de la construction, ainsi que les essais de référence pour ces caractéristiques.
Elle permet l’évaluation de la conformité du produit à la présente Norme européenne.
La présente Norme ne s’applique pas aux corniches qui ne sont pas revêtues de carton ni aux corniches en staff.

Predoblikovane mavčne plošče – Definicije, zahteve in preskusne metode

General Information

Status
Withdrawn
Publication Date
15-Nov-2005
Withdrawal Date
20-Jan-2026
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
05-Jul-2017
Completion Date
21-Jan-2026

Relations

Effective Date
07-Oct-2015

Get Certified

Connect with accredited certification bodies for this standard

Sponsored listings

Frequently Asked Questions

EN 14209:2005 is a standard published by the European Committee for Standardization (CEN). Its full title is "Preformed plasterboard cornices - Definitions, requirements and test methods". This standard covers: This European standard specifies the characteristics and performance of preformed plasterboard cornices intended to be used in building construction works either as part of the original specification or subsequently for improved decorative enrichment of the wall/ceiling angle in rooms. This standard covers the performance characteristics: reaction to fire and flexural strength. This standard covers also additional technical characteristics that are of importance for the use and acceptance of the product by the Construction Industry and the reference tests for these characteristics. It provides for the evaluation of conformity of the product to this European standard. This standard does not cover plain plaster and gypsum fibrous plasterwork cornices.

This European standard specifies the characteristics and performance of preformed plasterboard cornices intended to be used in building construction works either as part of the original specification or subsequently for improved decorative enrichment of the wall/ceiling angle in rooms. This standard covers the performance characteristics: reaction to fire and flexural strength. This standard covers also additional technical characteristics that are of importance for the use and acceptance of the product by the Construction Industry and the reference tests for these characteristics. It provides for the evaluation of conformity of the product to this European standard. This standard does not cover plain plaster and gypsum fibrous plasterwork cornices.

EN 14209:2005 is classified under the following ICS (International Classification for Standards) categories: 91.100.10 - Cement. Gypsum. Lime. Mortar; 91.180 - Interior finishing. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 14209:2005 has the following relationships with other standards: It is inter standard links to EN 14209:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 14209:2005 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC; Standardization Mandates: M/106. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 14209:2005 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Preformed plasterboard cornices - Definitions, requirements and test methodsHWRGHCorniches préformées en plâtre revetues de carton - Définitions, spécifications et méthodes d'essaiHohlkehlleisten aus kartonummanteltem Gips - Begriffe, Anforderungen und PrüfverfahrenTa slovenski standard je istoveten z:EN 14209:2005SIST EN 14209:2006en91.18091.100.10ICS:SLOVENSKI
STANDARDSIST EN 14209:200601-april-2006

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 14209November 2005ICS 91.100.10; 91.180 English VersionPreformed plasterboard cornices - Definitions, requirements andtest methodsCorniches préformées en plâtre revêtues de carton -Définitions, spécifications et méthodes d'essaiHohlkehlleisten aus Kartonummanteltem Gips - Begriffe,Anforderungen und PrüfverfahrenThis European Standard was approved by CEN on 16 September 2004.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2005 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14209:2005: E

Sampling procedure for testing.15 A.1 General.15 A.2 Sampling procedure.15 A.2.1 General.15 A.2.2 Random sampling.15 A.2.3 Representative sampling.15 Annex B (normative)
Mounting and fixing in the test according to EN 13823 (SBI test).17 Annex ZA (informative)
Clauses of this European Standard addressing provisions of EU Construction Products Directive.18 ZA.1 Scope and relevant characteristics.18 ZA.2 Attestation and declaration of conformity of preformed plasterboard cornices.19 ZA.3 CE marking and labelling.21 Bibliography.24

Diagram 1 — Family of gypsum products

Diagram 2 — Family of ancillary products

This standard covers also additional technical characteristics that are of importance for the use and acceptance of the product by the Construction Industry and the reference tests for these characteristics. It provides for the evaluation of conformity of the product to this European standard. This standard does not cover plain plaster and gypsum fibrous plasterwork cornices. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 520, Gypsum plasterboards - Definitions, requirements and test methods EN 13501-1, Fire classification of construction products and building elements – Part 1: Classification using test data from reaction to fire tests EN 13823, Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item EN 14496, Gypsum based adhesives for thermal/acoustic insulation composite panels and plasterboards - Definitions, requirements and test methods 3 Terms and definitions For the purposes of this European Standard, the following terms and definitions apply. 3.1 plasterboard cornice preformed paper covered gypsum section with profiled face supported by shoulders 3.2 face exposed surface usually concave, or partially concave with further contours to add embellishment 3.3 edge boundary between the face and back angle which defines thickness (AC, see Figure 1) 3.4 back angle return from edge, preset at a nominal 90° to facilitate positioning during application 3.5 end cut section of length

Figure 1 – Example of profile 4 Requirements 4.1 Reaction to fire Where subject to regulatory requirements, preformed plasterboard cornices shall be tested and classified in accordance with EN 13501-1. Preformed plasterboard cornices tested according to EN 13823 (SBI test) shall be mounted and fixed in accordance with Annex B or wfhen the producer wishes to claim performance for a specific intended use, the mounting and fixing shall be representative of that intended use. 4.2 Flexural strength (expressed as bending behaviour) Individual lengths shall be capable of being handled and installed using recommended practice. When tested in accordance with 5.4. the cornice shall not fracture. 4.3 Dangerous substances Materials used in products shall not release any dangerous substances in excess of the maximum permitted levels specified in a relevant European Standard for the material or permitted in the national regulations of the member state of destination. 4.4 Composition Preformed plasterboard cornices shall have constituents common to gypsum plasterboard to EN 520. The paper shall be suitable to receive decoration or be pre-finished. The abutting paper edges on the back of the cornice are, usually, concealed and secured by a self-adhesive paper tape. The core may contain additives, aggregates and/or fibres.

4.5.3 Face The face and edges shall be free from bumps, grooves, voids, blisters, burrs, scuffing and staining. The distance ED shall lie within the tolerance limits of ± 1 mm when checked in accordance with 5.3.
a) minimum dimensions ("NOT GO")
b) maximum dimensions ("GO") Figure 2 — Silhouette template 4.5.4 Back angle The back angle (CXC) designed to facilitate positioning to the wall/ceiling angle shall be not less than 90° when checked in accordance with 5.3. 4.5.5 Side angle The side angle (DAC) shall be of the specified profile e.g. square, bevelled or rounded when checked in accordance with 5.3. 4.5.6 Face width The face width of the product (AA) shall lie within the tolerance limits of 2 mm when checked in accordance with 5.3.

5.2.2.2 Apparatus a) flat surface; b) metal rule permitting readings to 1,0 mm. 5.2.2.3 Procedure Place the specimen on the flat surface and measure the length. 5.2.2.4 Expression of results Record the measurements of the three specimens. All specimens shall comply with 4.5.8. 5.3 Determination of accuracy of profile 5.3.1 Principle The accuracy, symmetry and angles of the profile across its length shall be checked for each specimen. 5.3.2 Apparatus A rigid plastics or aluminium sheet cut to provide a template, comprising two silhouettes, of the end profile of the cornice design. One cut to the minimum and one cut to the maximum tolerance specification (see Figure 2). 5.3.3 Procedure Place the templates in turn over one end of the specimen and pull each along the length of the specimen to check its compliance with the specification of the profile, noting freedom from identifiable bumps and grooves on the exposed face CADAC. 5.3.4 Expression of results Record the results of the exercise on all three specimens. All specimens shall comply with the profile requirements in 4.5.2. 5.4 Determination of bending behaviour 5.4.1 Principle The ability of the full size specimen shall be established to resist fracture when flexed under its own mass.
5.4.2 Apparatus a) A balance with a capacity of 10 kg permitting readings to 1 g; b) a timer capable of measuring 5 min; c) two (25 ± 5) mm diameter cylindrical steel supports, minimum 200 mm in length placed horizontally and parallel with a means of securing at one end or both ends to allow them to be spaced 1,5 m apart. The position should also permit the testing of cornice of maximum length.

Initial type testing shall be performed at the beginning of the production of a new preformed plasterboard cornices type (unless it is a member of a family previously tested) or at the beginning of a new method of production (where this may affect the stated properties). Tests previously performed in accordance with the provisions of this standard (same product, same characteristic(s), test method, sampling procedure, system of attestation of conformity, etc.) may be taken into account.

All product characteristics in Clause 4 applicable to the intended uses shall be subject to initial type testing, with the following exceptions:  release of dangerous substances may be assessed indirectly by controlling the content of the substance concerned;  when design values are used. 6.2.3 Further type testing Whenever a change occurs in the preformed plasterboard cornices design, the raw material or supplier of the components, or the p
...