Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete

SCOPE
1.1 This specification covers carbon-steel wire and welded wire reinforcement produced from hot-rolled rod to be used for the reinforcement of concrete. The steel wire is cold-worked, drawn or rolled, plain (non-deformed, as-drawn or galvanized), or deformed. Welded wire reinforcement is made from plain or deformed wire, or a combination of plain and deformed wire. Common wire sizes and dimensions are given in Table 1, Table 2, Table 3, and Table 4. Actual wire sizes are not restricted to those shown in the tables. (A) Table 1 should be used on projects that are designed using inch-pound units; Table 2 should be used on projects that are designed using SI units.(B) The number following the prefix indicates the nominal cross-sectional area of the wire in square inches multiplied by 100.(C) For sizes other than those shown above, the Size Number shall be the number of one hundredth of a square inch in the nominal area of the wire cross section, prefixed by the W.(D) These sizes represent the most readily available sizes in the welded wire reinforcement industry. Other wire sizes are available and many manufactures can produce them in 0.0015 in.2 increments.(E) The nominal diameter is based on the nominal area of the wire.  (A) The wire sizes in Table 1 should be used on projects that are designed using inch-pound units; the wire sizes in Table 2 should be used on projects that are designed using SI units.(B) The number following the prefix indicates the nominal cross-sectional area of the wire in square milimetres.(C) For sizes other than those shown above, the Size Number shall be the number of square millimetres in the nominal area of the wire cross section, prefixed by the MW.(D) These sizes represent the most readily available sizes in the welded wire reinforcement industry. Other wire sizes are available and many manufactures can produce them in 1 mm2 increments.(E) The nominal diameter is based on the nominal area of the wire.  (A) The wire sizes in Table 3 should be used on projects that are designed using inch-pound units; the wire sizes in Table 4 should be used on projects that are designed using SI units.(B) The number following the prefix indicates the nominal cross-sectional area of the deformed wire in square inches multiplied by 100.(C) For sizes other than those shown above, the Size Number shall be the number of one hundredths of a square inch in the nominal area of the deformed wire cross section, prefixed by the D.(D) These sizes represent the most readily available sizes in the welded wire reinforcement industry. Other wire sizes are available and many manufacturers can produce them in 0.0015 in.2 increments.(E) The nominal diameter of a deformed wire is equivalent to the nominal diameter of a plain wire having the same weight per foot as the deformed wire.(F) The cross-sectional area is based on the weight of the wire. The area in square inches may be calculated by dividing the weight in pounds by 0.2833 (weight of 1 in.3 of steel) or by dividing the weight per lineal foot of specimen in pounds by 3.4 (weight of steel 1 in. square and 1 foot long).(G) The minimum average height of the deformations shall be determined from measurements made on not less than two typical deformations from each line of deformations on the wire. Measurements shall be made at the center of indentation or between two raised ribs as described in 7.2.4.7.(H) Spacing of deformations shall not be greater than 0.285 in. nor less than 0.182 in. for all wire sizes.(I) See 7.2.4.3 for average number of deformations per unit length.  (A) The wire sizes in Table 3 should be used on projects that are designed using inch-pound units; the wire sizes in Table 4 should be used on projects that are designed using SI units.(B) The number following the prefix indicates the nominal cross-sectional area of the deformed wire in square millimetres.(C) For sizes other than those shown above, the Size Number shall be the number of square ...

General Information

Status
Historical
Publication Date
28-Feb-2015
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM A1064/A1064M-15 - Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM A1064/A1064M-15 - Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:A1064/A1064M −15
StandardSpecification for
Carbon-Steel Wire and Welded Wire Reinforcement, Plain
1
and Deformed, for Concrete
This standard is issued under the fixed designation A1064/A1064M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* A370 Test Methods and Definitions for Mechanical Testing
of Steel Products
1.1 This specification covers carbon-steel wire and welded
A641/A641M Specification for Zinc–Coated (Galvanized)
wirereinforcementproducedfromhot-rolledrodtobeusedfor
Carbon Steel Wire
the reinforcement of concrete. The steel wire is cold-worked,
A700 Guide for Packaging, Marking, and Loading Methods
drawnorrolled,plain(non-deformed,as-drawnorgalvanized),
for Steel Products for Shipment
or deformed.Welded wire reinforcement is made from plain or
E83 Practice for Verification and Classification of Exten-
deformed wire, or a combination of plain and deformed wire.
someter Systems
CommonwiresizesanddimensionsaregiveninTable1,Table
3
2.2 U.S. Military Standard:
2, Table 3, and Table 4. Actual wire sizes are not restricted to
those shown in the tables. MIL-STD-129 Marking for Shipment and Storage
3
2.3 U.S. Military Standard:
NOTE 1—Welded wire for concrete reinforcement has historically been
described by various terms: welded wire fabric, WWF, fabric, and mesh.
Fed. Std. No. 123 Marking for Shipments (Civil Agencies)
The wire reinforcement industry has adopted the term welded wire
4
2.4 American Concrete Institute (ACI) Standard:
reinforcement (WWR) as being more representative of the applications of
ACI 318 Building Code Requirements for Structural Con-
the products being manufactured. Therefore, the term welded wire fabric
has been replaced with the term welded wire reinforcement in this
crete
specification and in related specifications.
2.5 Adjuncts:
5
1.2 The values stated in either inch-pound or SI units are to
Weld Tester Drawing
be regarded separately as standard. Within the text the SI units
are shown in brackets (except in Table 2 and Table 4). The
3. Terminology
values stated in each system are not exact equivalents;
3.1 Definitions of Terms Specific to This Standard:
therefore,eachsystemmustbeusedindependentlyoftheother.
3.1.1 convoluted wire—when wire for welded wire rein-
Combining values may result in nonconformance with the
forcement is formed into a sinusoidal wave shape, it is
specification.
commonly referred to as convoluted wire. The wire is used in
1.3 This standard does not purport to address all of the
the manufacture of cages for certain applications of concrete
safety concerns, if any, associated with its use. It is the
pipe reinforcement. Deformed wire is not subject to convolu-
responsibility of the user of this standard to establish appro-
tion unless agreed upon by the purchaser and manufacturer.
priate safety and health practices and determine the applica-
3.1.2 deformed wire and welded deformed wire
bility of regulatory limitations prior to use.
reinforcement—as used within the scope and intent of this
specification, designates a material composed of cold-worked
2. Referenced Documents
deformed steel wire as cold-drawn or cold-rolled from hot-
2
2.1 ASTM Standards:
rolled steel rod. Deformations can be indented or raised rib
(protrusion) types. The deformations and the welded intersec-
tions provide bond strength for shear resistance.
1
This specification is under the jurisdiction ofASTM Committee A01 on Steel,
Stainless Steel and Related Alloys and is the direct responsibility of Subcommittee
A01.05 on Steel Reinforcement.
3
Current edition approved March 1, 2015. Published May 2015. Originally Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,
approved in 2009. Last previous edition approved in 2014 as A1064/A1064M – 14. Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http://
DOI: 10.1520/A1064_A1064M-15. www.dodssp.daps.mil.
2 4
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Available fromAmerican Concrete Institute (ACI), P.O. Box 9094, Farmington
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Hills, MI 48333-9094, http://www.concrete.org.
5
Standards volume information, refer to the standard’s Document Summary page on Available from ASTM International Headquarters. Order Adjunct No.
the ASTM website. ADJA0185. Original adjunct produced in 1967.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: A1064/A1064M − 14 A1064/A1064M − 15
Standard Specification for
Carbon-Steel Wire and Welded Wire Reinforcement, Plain
1
and Deformed, for Concrete
This standard is issued under the fixed designation A1064/A1064M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This specification covers carbon-steel wire and welded wire reinforcement produced from hot-rolled rod to be used for the
reinforcement of concrete. The steel wire is cold-worked, drawn or rolled, plain (non-deformed, as-drawn or galvanized), or
deformed. Welded wire reinforcement is made from plain or deformed wire, or a combination of plain and deformed wire.
Common wire sizes and dimensions are given in Table 1, Table 2, Table 3, and Table 4. Actual wire sizes are not restricted to those
shown in the tables.
NOTE 1—Welded wire for concrete reinforcement has historically been described by various terms: welded wire fabric, WWF, fabric, and mesh. The
wire reinforcement industry has adopted the term welded wire reinforcement (WWR) as being more representative of the applications of the products
being manufactured. Therefore, the term welded wire fabric has been replaced with the term welded wire reinforcement in this specification and in related
specifications.
1.2 Supplementary Requirements describe high-strength wire, which manufacturers furnish when specifically ordered.
Manufacturers furnish high-strength wire in place of regular wire if mutually agreed to by the purchaser and the manufacturer.
1.2 The values stated in either inch-pound or SI units are to be regarded separately as standard. Within the text the SI units are
shown in brackets (except in Table 2 and Table 4). The values stated in each system are not exact equivalents; therefore, each
system must be used independently of the other. Combining values may result in nonconformance with the specification.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
A370 Test Methods and Definitions for Mechanical Testing of Steel Products
A641/A641M Specification for Zinc–Coated (Galvanized) Carbon Steel Wire
A700 Guide for Packaging, Marking, and Loading Methods for Steel Products for Shipment
E83 Practice for Verification and Classification of Extensometer Systems
3
2.2 U.S. Military Standard:
MIL-STD-129 Marking for Shipment and Storage
3
2.3 U.S. Military Standard:
Fed. Std. No. 123 Marking for Shipments (Civil Agencies)
4
2.4 American Concrete Institute (ACI) Standard:
ACI 318 Building Code Requirements for Structural Concrete
2.5 Adjuncts:
5
Weld Tester Drawing
1
This specification is under the jurisdiction of ASTM Committee A01 on Steel, Stainless Steel and Related Alloys and is the direct responsibility of Subcommittee A01.05
on Steel Reinforcement.
Current edition approved Nov. 1, 2014March 1, 2015. Published November 2014May 2015. Originally approved in 2009. Last previous edition approved in 20132014
as A1064/A1064M – 13.14. DOI: 10.1520/A1064_A1064M-14.10.1520/A1064_A1064M-15.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’sstandard’s Document Summary page on the ASTM website.
3
Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http://www.dodssp.daps.mil.
4
Available from American Concrete Institute (ACI), P.O. Box 9094, Farmington Hills, MI 48333-9094, http://www.concrete.org.
5
Available from ASTM International Headquarters. Order Adjunct No. ADJA0185. Original adjunct produced in 1967.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
A1064/A1064M − 15
A
TABLE 1 Dimensional Requirements for Plain Wire—Inch-Pound Units
colwidth="34.91*"/COLSPEC
Nominal Diameter Nominal Area
B, C, D
Size Number
E
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.